Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Restor Dent Endod ; 47(1): e13, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35284326

RESUMEN

Objectives: This study evaluated the efficacy of 3 reciprocating systems and the effects of 2 instruments for irrigant activation on filling material removal. Materials and Methods: Forty mesiobuccal roots of maxillary molars were prepared up to size 25.06 and obturated. Micro-computed tomography (micro-CT) examination #1 was performed. Teeth were then divided into 4 groups (n = 10), according to the retreatment protocol: (1) manual, (2) Reciproc Blue, (3) WaveOne Gold, and (4) X1 Blue. Micro-CT examinations #2 and #3 were performed after filling removal and repreparation, respectively. Next, all teeth were divided into 2 new groups (n = 20) according to the irrigant activation protocol: XP Clean (XP Clean size 25.02) and Flatsonic (Flatsonic ultrasonic tip). Micro-CT examination #4 was performed after irrigant activation. Statistical analysis was performed with a significance level set at 5%. Results: WaveOne Gold removed a significantly greater amount of filling material than the manual group (p < 0.05). The time to reach the WL was similar for all reciprocating systems (p > 0.05). X1 Blue was faster than the manual group (p < 0.05). Only manual group improved the filling material removal after the repreparation stage (p < 0.05). Both activation protocols significantly improved the filling material removal (p < 0.05), without differences between them (p > 0.05). Conclusions: None of the tested instruments completely removed the filling material. X1 Blue size 25.06 reached the working length in the shortest time. XP Clean and Flatsonic improved the filling material removal.

2.
J Endod ; 47(9): 1481-1486, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34139263

RESUMEN

INTRODUCTION: This study aimed to use micro-computed tomographic imaging to analyze the quality of the endodontic preparation of mesial canals in mandibular molars provided by 3 instrumentation protocols. METHODS: Forty-five extracted mandibular molars with 2 independent mesial canals were selected, and the initial micro-computed tomographic imaging was performed. The initial volume values of the canals were submitted to statistical analysis for paired division. The groups were determined according to the final enlargement of the canal and the working length adopted (ie, G25.06/+1 mm, G35.05/foramen, and G50.01/-1 mm). At the end of each instrumentation sequence, the root canals were scanned and analyzed with regard to the increase in the total and apical volume, centralization, and preparation transportation and the percentage of the total and apical uninstrumented walls. RESULTS: For the intragroup comparison, the Wilcoxon test was used, and for the intergroup analysis, the Kruskal-Wallis and Dunn tests were used (P < .05). In the analysis of the canal total volume, a statistical difference was found between G25.06/+1 mm and the remaining groups (P < .05). In the apical third, a statistical difference was observed between G25.06/+1 mm and G50.01/-1 mm (P < .05). No statistical difference was found between the groups in terms of centralization and transportation of the preparation or in terms of the percentage of the total or apical uninstrumented walls. CONCLUSIONS: The preparation of the mesial canals of mandibular molars up to larger tip files but with a lower taper at 1 mm before the foramen resulted in a larger volume of apical preparation, kept the preparation centralized, and provided safe apical dentin wear without excessive cervical wear.


Asunto(s)
Cavidad Pulpar , Preparación del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen , Microtomografía por Rayos X
3.
Braz Oral Res ; 33: e011, 2019 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-30758408

RESUMEN

To evaluate the influence of novel ultrasonic tips as an auxiliary method for the rotary preparation of flattened/oval-shaped canals. Forty-five mandibular incisors were selected and divided into one of three experimental groups (n = 15): Group PFCP - ProDesign Logic 25/.05 + Flatsonic + Clearsonic + Prodesign Logic 40/.01; Group FCP - Flatsonic + Clearsonic + ProDesign Logic 40/.01; and Group PP - Prodesign Logic 25/.05 + Prodesign Logic 40/.05. The teeth were scanned preoperatively and postoperatively using microcomputed tomography. The percentage values for increase in volume, non-instrumented surface area, dentin removal, degree of canal transportation, and centering ratio between the experimental groups were examined. Data were analyzed using the non-parametric Kruskal-Wallis and Dunn's tests (p < 0.05). Group PFCP showed the greatest volume increase in the total portion of the root canal and the lowest percentage of non-instrumented surface area. Regarding the degree of transportation in the buccolingual direction, statistically significant differences between groups PFCP and PP were observed at the coronal third of the canal. In the mesiodistal direction, no statistically significant differences were observed at the coronal, middle, and apical thirds. As for the centering ratio, statistically significant differences were found in the buccolingual direction. In the mesiodistal direction, no statistically significant differences were observed at the coronal, middle, and apical thirds. The use of novel ultrasonic tips combined with rotary instruments in group PFCP provided a significant increase in volume and reduced the percentage of non-instrumented areas during the preparation of flattened/oval-shaped canals.


Asunto(s)
Cavidad Pulpar/anatomía & histología , Preparación del Conducto Radicular/instrumentación , Terapia por Ultrasonido/instrumentación , Instrumentos Dentales/normas , Dentina/cirugía , Diseño de Equipo , Humanos , Microscopía Electrónica de Rastreo , Valores de Referencia , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Propiedades de Superficie , Resultado del Tratamiento , Microtomografía por Rayos X/métodos
4.
Braz. oral res. (Online) ; 33: e011, 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-989484

RESUMEN

Abstract To evaluate the influence of novel ultrasonic tips as an auxiliary method for the rotary preparation of flattened/oval-shaped canals. Forty-five mandibular incisors were selected and divided into one of three experimental groups (n = 15): Group PFCP - ProDesign Logic 25/.05 + Flatsonic + Clearsonic + Prodesign Logic 40/.01; Group FCP - Flatsonic + Clearsonic + ProDesign Logic 40/.01; and Group PP - Prodesign Logic 25/.05 + Prodesign Logic 40/.05. The teeth were scanned preoperatively and postoperatively using microcomputed tomography. The percentage values for increase in volume, non-instrumented surface area, dentin removal, degree of canal transportation, and centering ratio between the experimental groups were examined. Data were analyzed using the non-parametric Kruskal-Wallis and Dunn's tests (p < 0.05). Group PFCP showed the greatest volume increase in the total portion of the root canal and the lowest percentage of non-instrumented surface area. Regarding the degree of transportation in the buccolingual direction, statistically significant differences between groups PFCP and PP were observed at the coronal third of the canal. In the mesiodistal direction, no statistically significant differences were observed at the coronal, middle, and apical thirds. As for the centering ratio, statistically significant differences were found in the buccolingual direction. In the mesiodistal direction, no statistically significant differences were observed at the coronal, middle, and apical thirds. The use of novel ultrasonic tips combined with rotary instruments in group PFCP provided a significant increase in volume and reduced the percentage of non-instrumented areas during the preparation of flattened/oval-shaped canals.


Asunto(s)
Humanos , Terapia por Ultrasonido/instrumentación , Preparación del Conducto Radicular/instrumentación , Cavidad Pulpar/anatomía & histología , Valores de Referencia , Propiedades de Superficie , Microscopía Electrónica de Rastreo , Reproducibilidad de los Resultados , Resultado del Tratamiento , Estadísticas no Paramétricas , Instrumentos Dentales/normas , Dentina/cirugía , Diseño de Equipo , Microtomografía por Rayos X/métodos
5.
Dent. press endod ; 10(1): 49-53, Jan-Apr2020. Tab, Ilus
Artículo en Inglés | LILACS | ID: biblio-1344228

RESUMEN

O objetivo do presente trabalho foi avaliar a influência da velocidade de rotação na resistência à fadiga cíclica do instrumento rotatório Logic 25.06 (LOG 25.06; Easy Equipamentos Odontológicos, Belo Horizonte, Brasil). Métodos: Foram utilizados 20 instrumentos rotatórios Logic 25.06 (n=10). O teste de fadiga cíclica foi realizado em um aparato com um canal artificial de aço inoxidável com ângulo de curvatura de 60° e raio de 5 mm. Os instrumentos foram utilizados a 950 e 550 rotações por minuto (RPM), sendo mensurados o tempo e o número de ciclos para a fratura. Os dados foram analisados estatisticamente por meio do teste t de Student, sendo selecionado um nível de significância de 5%. Resultados: O teste de fadiga cíclica demonstrou que a velocidade de 550 RPM promoveu um aumento significativo no tempo e no número de ciclos para a fratura dos instrumentos LOG 25.06 (p<0,05). Houve um aumento de 95,9% no tempo e de 27,25% do número de ciclos para a fratura. Conclusão: Os resultados desse estudo demonstraram que a velocidade de rotação possui uma influência significativa na resistência à fadiga cíclica dos instrumentos rotatório Logic 25.06. A velocidade de 550 RPM é uma velocidade mais segura, aumentando significativamente a resistência à fadiga cíclica (AU).


Objective: The aim of this study was to evaluate the influence of rotational speed on the cyclic fatigue resistance of Logic 25.06 rotary instruments (LOG 25.06; Easy Equipamentos Odontológicos, Belo Horizonte, Brazil). Methods: 20 Logic 25.06 instruments were used (n=20). The cyclic fatigue test was performed in an artificial canal made of stainless steel with 60° of curvature and 5 mm of radius. The instruments were activated 950 and 550 rotations per minute (RPM) until the fracture occurred. The time (in seconds) and the number of cycles to fracture (NCF) were measured. The data were statistically analyzed using One-way ANOVA and Tukey Test, the level significance used was 5 %. Results: the 550 RPM promoted a significantly higher time and NCF of LOG 25.06 in comparison with 950 RPM (P>0.05). The time increased in 95.9% and the NCF 27.25%. Conclusion: The results of this study showed that the rotational speed had a significant influence on the cyclic fatigue resistance of the Logic 25.06 rotary instruments. The 550 RPM rotational speed seems to be safer than 950 RPM, increasing the cyclic fatigue resistance of Logic 25.06 (AU).


Asunto(s)
Rotación , Equipo Dental , Endodoncia , Análisis de Varianza , Fatiga
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA