Reprod Biomed Online ; 42(2): 421-428, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33279419

RESUMEN

RESEARCH QUESTION: Ovarian stimulation during IVF cycles involves close monitoring of oestradiol, progesterone and ultrasound measurements of follicle growth. In contrast to blood draws, sampling saliva is less invasive. Here, a blind validation is presented of a novel saliva-based oestradiol and progesterone assay carried out in samples collected in independent IVF clinics. DESIGN: Concurrent serum and saliva samples were collected from 324 patients at six large independent IVF laboratories. Saliva samples were frozen and run blinded. A further 18 patients had samples collected more frequently around the time of HCG trigger. Saliva samples were analysed using an immunoassay developed with Salimetrics LLC. RESULTS: In total, 652 pairs of saliva and serum oestradiol were evaluated, with correlation coefficients ranging from 0.68 to 0.91. In the European clinics, a further 237 of saliva and serum progesterone samples were evaluated; however, the correlations were generally poorer, ranging from -0.02 to 0.22. In the patients collected more frequently, five out of 18 patients (27.8%) showed an immediate decrease in oestradiol after trigger. When progesterone samples were assessed after trigger, eight out of 18 (44.4%) showed a continued rise. CONCLUSIONS: Salivary oestradiol hormone testing correlates well to serum-based assessment, whereas progesterone values, around the time of trigger, are not consistent from patient to patient.


Asunto(s)
Estradiol/análisis , Inducción de la Ovulación , Progesterona/análisis , Saliva/química , Adulto , Europa (Continente) , Femenino , Hormona Liberadora de Gonadotropina/agonistas , Humanos , Leuprolida , Estudios Prospectivos , Estados Unidos , Adulto Joven
2.
J Clin Microbiol ; 59(1)2020 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-33067270

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the cause of an ongoing pandemic that has infected over 36 million and killed over 1 million people. Informed implementation of government public health policies depends on accurate data on SARS-CoV-2 immunity at a population scale. We hypothesized that detection of SARS-CoV-2 salivary antibodies could serve as a noninvasive alternative to serological testing for monitoring of SARS-CoV-2 infection and seropositivity at a population scale. We developed a multiplex SARS-CoV-2 antibody immunoassay based on Luminex technology that comprised 12 CoV antigens, mostly derived from SARS-CoV-2 nucleocapsid (N) and spike (S). Saliva and sera collected from confirmed coronavirus disease 2019 (COVID-19) cases and from the pre-COVID-19 era were tested for IgG, IgA, and IgM to the antigen panel. Matched saliva and serum IgG responses (n = 28) were significantly correlated. The salivary anti-N IgG response resulted in the highest sensitivity (100%), exhibiting a positive response in 24/24 reverse transcription-PCR (RT-PCR)-confirmed COVID-19 cases sampled at >14 days post-symptom onset (DPSO), whereas the salivary anti-receptor binding domain (RBD) IgG response yielded 100% specificity. Temporal kinetics of IgG in saliva were consistent with those observed in blood and indicated that most individuals seroconvert at around 10 DPSO. Algorithms employing a combination of the IgG responses to N and S antigens result in high diagnostic accuracy (100%) by as early as 10 DPSO. These results support the use of saliva-based antibody testing as a noninvasive and scalable alternative to blood-based antibody testing.


Asunto(s)
Anticuerpos Antivirales/análisis , Anticuerpos Antivirales/sangre , COVID-19/diagnóstico , SARS-CoV-2/inmunología , Saliva/inmunología , Prueba de Ácido Nucleico para COVID-19/métodos , Proteínas de la Nucleocápside de Coronavirus/inmunología , Femenino , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Glicoproteína de la Espiga del Coronavirus/inmunología
3.
Front Immunol ; 11: 2095, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32983163

RESUMEN

Human cytomegalovirus (HCMV) infects more than 80% of the global population. While mostly asymptomatic, HCMV infection can be serious among the immunocompromised, and it is implicated in chronic disease pathophysiology in adulthood. Large-scale minimally invasive HCMV screening could advance research and public health efforts to monitor infection prevalence and prevent or mitigate downstream risks associated with infection. We examine the utility of measuring HCMV immunoglobulin-G (IgG) levels in saliva as an index of serum levels. Matched serum and saliva samples from healthy adults (N = 98; 44% female; 51% white) were assayed for HCMV IgG, total salivary protein, and salivary markers related to oral inflammation, blood, and tissue integrity. We examine the serum-saliva association for HCMV IgG and assess the influence of participant characteristics and factors specific to the oral compartment (e.g., oral inflammation) on HCMV IgG levels and cross-specimen relations. We found a robust serum-saliva association for HCMV IgG with serum antibody levels accounting for >60% of the variance in salivary levels. This relation remained after adjusting for key demographic and oral immune-related variables. Compared to the serum test, the salivary HCMV IgG test had 51% sensitivity and 97% specificity. With improvements in assay performance and sample optimization, HCMV antibody levels in oral fluids may be a useful proxy for serum levels.


Asunto(s)
Anticuerpos Antivirales/sangre , Infecciones por Citomegalovirus/sangre , Citomegalovirus/metabolismo , Inmunoglobulina G/sangre , Saliva/metabolismo , Proteínas y Péptidos Salivales/metabolismo , Adulto , Estudios Transversales , Femenino , Humanos , Masculino
4.
Nat Biotechnol ; 37(4): 407-419, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30804536

RESUMEN

Peripheral biochemical monitoring involves the use of wearable devices for minimally invasive or noninvasive measurement of analytes in biofluids such as interstitial fluid, saliva, tears and sweat. The goal in most cases is to obtain measurements that serve as surrogates for circulating analyte concentrations in blood. Key technological developments to date include continuous glucose monitors, which use an indwelling sensor needle to measure glucose in interstitial fluid, and device-integrated sweat stimulation for continuous access to analytes in sweat. Further development of continuous sensing technologies through new electrochemical sensing modalities will be a major focus of future research. While there has been much investment in wearable technologies to sense analytes, less effort has been directed to understanding the physiology of biofluid secretion. Elucidating the underlying biology is crucial for accelerating technological progress, as the biofluid itself often presents the greatest challenge in terms of sample volumes, secretion rates, filtration, active analyte channels, variable pH and salinity, analyte breakdown and other confounding factors.


Asunto(s)
Técnicas Biosensibles/instrumentación , Líquidos Corporales/química , Monitoreo Fisiológico/instrumentación , Dispositivos Electrónicos Vestibles , Adulto , Técnicas Biosensibles/métodos , Biotecnología , Glucemia/análisis , Líquido Extracelular/química , Femenino , Glucosa/análisis , Humanos , Masculino , Monitoreo Fisiológico/métodos , Saliva/química , Sudor/química , Adulto Joven
5.
J Immunol Methods ; 448: 1-8, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28478117

RESUMEN

BACKGROUND: Hepatitis E virus (HEV) infection causes significant morbidity and mortality worldwide, particularly among pregnant women. In clinical settings blood-based testing protocols are commonly used to diagnose HEV infection, but in community settings such invasive sampling can hinder study participation and limit discovery of the ecology and natural history of HEV infection. Oral fluid is a non-invasive biospecimen that can harbor pathogen-specific antibodies and has the potential to replace blood-based testing protocols. OBJECTIVES: To develop an immunoassay to assess past and recent HEV infection that uses oral fluid instead of serum or plasma. METHODS: The assay was validated using paired oral fluid and serum samples collected from 141 patients who presented either with (n=76) or without (n=65) symptoms of acute viral hepatitis at a clinical diagnostics center in Dhaka, Bangladesh. The sensitivity and specificity of the oral fluid-based immunoassay for HEV IgG (past HEV infection) and HEV IgA (recent HEV infection) antibodies was calculated in reference to Wantai's (Beijing Wantai) serum-based HEV enzyme-linked immunosorbent assay (ELISA) kits for IgG and IgM antibodies, respectively. RESULTS: The sensitivity and specificity of the oral fluid-based immunoassay for HEV-IgG antibodies were 98.7% and 98.4%, respectively. The sensitivity and specificity of the oral fluid-based immunoassay for HEV IgA were 89.5% and 98.3%, respectively. CONCLUSIONS: The high concordance of our non-invasive oral fluid-based immunoassays (HEV IgG and HEV IgA) with commercial high-performance serum HEV ELISA kits (IgG and IgM) means that population-based surveillance of past and recent HEV infection could be expanded to improve understanding of its ecology and natural history.


Asunto(s)
Anticuerpos Antivirales/análisis , Virus de la Hepatitis E/inmunología , Hepatitis E/diagnóstico , Inmunoensayo/métodos , Inmunoglobulina A/análisis , Inmunoglobulina G/análisis , Saliva/virología , Adulto , Bangladesh/epidemiología , Biomarcadores/análisis , Estudios de Casos y Controles , Ensayo de Inmunoadsorción Enzimática , Femenino , Hepatitis E/epidemiología , Hepatitis E/inmunología , Hepatitis E/virología , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevalencia , Reproducibilidad de los Resultados , Pruebas Serológicas , Adulto Joven
6.
Psychoneuroendocrinology ; 63: 235-7, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26519777

RESUMEN

Nerve growth factor (NGF), a neurotrophin, modulates a diverse set of physiologic processes in the nervous, immune, and endocrine systems. Studies suggest that NGF can be measured in saliva (sNGF). Historically, the method for measuring sNGF involves the off-label use of an enzyme immunoassay designed for use with cell-culture supernatants/tissue extracts (Nam et al., 2007; Ruhl et al., 2004). In a series of experiments we reveal this measurement strategy is subject to non-specific interference by constituents present in oral fluids. We conclude that the measurement of sNGF by this assay is not optimal for use with oral fluid specimens.


Asunto(s)
Factor de Crecimiento Nervioso/metabolismo , Saliva/metabolismo , Humanos , Inmunoensayo/métodos , Inmunoensayo/normas , Factor de Crecimiento Nervioso/análisis , Valor Predictivo de las Pruebas , Juego de Reactivos para Diagnóstico/normas , Reproducibilidad de los Resultados , Saliva/química