Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Nanobiotechnology ; 21(1): 269, 2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37574546

RESUMEN

Successful biomaterial implantation requires appropriate immune responses. Macrophages are key mediators involved in this process. Currently, exploitation of the intrinsic properties of biomaterials to modulate macrophages and immune responses is appealing. In this study, we prepared hydrophilic nanofibers with an aligned topography by incorporating polyethylene glycol and polycaprolactone using axial electrospinning. We investigated the effect of the nanofibers on macrophage behavior and the underlying mechanisms. With the increase of hydrophilicity of aligned nanofibers, the inflammatory gene expression of macrophages adhering to them was downregulated, and M2 polarization was induced. We further presented clear evidence that the inflammasome NOD-like receptor thermal protein domain associated protein 3 (NLRP3) was the cellular sensor by which macrophages sense the biomaterials, and it acted as a regulator of the macrophage-mediated response to foreign bodies and implant integration. In vivo, we showed that the fibers shaped the implant-related immune microenvironment and ameliorated peritendinous adhesions. In conclusion, our study demonstrated that hydrophilic aligned nanofibers exhibited better biocompatibility and immunological properties.


Asunto(s)
Inflamasomas , Nanofibras , Inflamasomas/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Macrófagos/metabolismo , Materiales Biocompatibles/farmacología , Materiales Biocompatibles/metabolismo , Interacciones Hidrofóbicas e Hidrofílicas
2.
J Nanobiotechnology ; 20(1): 25, 2022 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-34991615

RESUMEN

BACKGROUND: The regeneration and repair of articular cartilage remains a major challenge for clinicians and scientists due to the poor intrinsic healing of this tissue. Since cartilage injuries are often clinically irregular, tissue-engineered scaffolds that can be easily molded to fill cartilage defects of any shape that fit tightly into the host cartilage are needed. METHOD: In this study, bone marrow mesenchymal stem cell (BMSC) affinity peptide sequence PFSSTKT (PFS)-modified chondrocyte extracellular matrix (ECM) particles combined with GelMA hydrogel were constructed. RESULTS: In vitro experiments showed that the pore size and porosity of the solid-supported composite scaffolds were appropriate and that the scaffolds provided a three-dimensional microenvironment supporting cell adhesion, proliferation and chondrogenic differentiation. In vitro experiments also showed that GelMA/ECM-PFS could regulate the migration of rabbit BMSCs. Two weeks after implantation in vivo, the GelMA/ECM-PFS functional scaffold system promoted the recruitment of endogenous mesenchymal stem cells from the defect site. GelMA/ECM-PFS achieved successful hyaline cartilage repair in rabbits in vivo, while the control treatment mostly resulted in fibrous tissue repair. CONCLUSION: This combination of endogenous cell recruitment and chondrogenesis is an ideal strategy for repairing irregular cartilage defects.


Asunto(s)
Condrogénesis/efectos de los fármacos , Matriz Extracelular Descelularizada , Hidrogeles , Oligopéptidos , Andamios del Tejido/química , Animales , Cartílago Articular/citología , Matriz Extracelular Descelularizada/química , Matriz Extracelular Descelularizada/farmacología , Hidrogeles/química , Hidrogeles/farmacología , Masculino , Células Madre Mesenquimatosas/efectos de los fármacos , Oligopéptidos/química , Oligopéptidos/farmacología , Conejos , Ingeniería de Tejidos/métodos
3.
Cell Tissue Bank ; 20(3): 351-365, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31218457

RESUMEN

The extracellular matrix (ECM) is a dynamic and intricate three-dimensional (3D) microenvironment with excellent biophysical, biomechanical, and biochemical properties that may directly or indirectly regulate cell behavior, including proliferation, adhesion, migration, and differentiation. Compared with tissue-derived ECM, cell-derived ECM potentially has more advantages, including less potential for pathogen transfer, fewer inflammatory or anti-host immune responses, and a closer resemblance to the native ECM microenvironment. Different types of cell-derived ECM, such as adipose stem cells, synovium-derived stem cells and bone marrow stromal cells, their effects on articular chondrocytes which have been researched. In this study, we aimed to develop a 3D cell culture substrate using decellularized ECM derived from human umbilical cord-derived mesenchymal stem cells (hUCMSCs), and evaluated the effects on articular chondrocytes. We evaluated the morphology and components of hUCMSC-derived ECM using physical and chemical methods. Morphological, histological, immunohistochemical, biochemical, and real-time PCR analyses demonstrated that proliferation and differentiation capacity of chondrocytes using the 3D hUCMSC-derived ECM culture substrate was superior to that using non-coated two-dimensional plastic culture plates. In conclusion, 3D decellularized ECM derived from hUCMSCs offers a tissue-specific microenvironment for in vitro culture of chondrocytes, which not only markedly promoted chondrocyte proliferation but also preserved the differentiation capacity of chondrocytes. Therefore, our findings suggest that a 3D cell-derived ECM microenvironment represents a promising prospect for autologous chondrocyte-based cartilage tissue engineering and regeneration. The hUCMSC-derived ECM as a biomaterial is used for the preparation of scaffold or hybrid scaffold products which need to further study in the future.


Asunto(s)
Diferenciación Celular , Proliferación Celular , Condrocitos/citología , Matriz Extracelular/metabolismo , Células Madre Mesenquimatosas/citología , Cordón Umbilical/citología , Tejido Adiposo/citología , Animales , Materiales Biocompatibles/metabolismo , Cartílago Articular/citología , Adhesión Celular , Técnicas de Cultivo de Célula , Movimiento Celular , Condrocitos/metabolismo , Condrogénesis , Fibronectinas/química , Humanos , Inflamación , Conejos , Ingeniería de Tejidos/instrumentación , Andamios del Tejido
4.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(6): 748-754, 2024 Jun 15.
Artículo en Zh | MEDLINE | ID: mdl-38918198

RESUMEN

Objective: To investigate the construction of a novel tissue engineered meniscus scaffold based on low temperature deposition three-dimenisonal (3D) printing technology and evaluate its biocompatibility. Methods: The fresh pig meniscus was decellularized by improved physicochemical method to obtain decellularized meniscus matrix homogenate. Gross observation, HE staining, and DAPI staining were used to observe the decellularization effect. Toluidine blue staining, safranin O staining, and sirius red staining were used to evaluate the retention of mucopolysaccharide and collagen. Then, the decellularized meniscus matrix bioink was prepared, and the new tissue engineered meniscus scaffold was prepared by low temperature deposition 3D printing technology. Scanning electron microscopy was used to observe the microstructure. After co-culture with adipose-derived stem cells, the cell compatibility of the scaffolds was observed by cell counting kit 8 (CCK-8), and the cell activity and morphology were observed by dead/live cell staining and cytoskeleton staining. The inflammatory cell infiltration and degradation of the scaffolds were evaluated by subcutaneous experiment in rats. Results: The decellularized meniscus matrix homogenate appeared as a transparent gel. DAPI and histological staining showed that the immunogenic nucleic acids were effectively removed and the active components of mucopolysaccharide and collagen were remained. The new tissue engineered meniscus scaffolds was constructed by low temperature deposition 3D printing technology and it had macroporous-microporous microstructures under scanning electron microscopy. CCK-8 test showed that the scaffolds had good cell compatibility. Dead/live cell staining showed that the scaffold could effectively maintain cell viability (>90%). Cytoskeleton staining showed that the scaffolds were benefit for cell adhesion and spreading. After 1 week of subcutaneous implantation of the scaffolds in rats, there was a mild inflammatory response, but no significant inflammatory response was observed after 3 weeks, and the scaffolds gradually degraded. Conclusion: The novel tissue engineered meniscus scaffold constructed by low temperature deposition 3D printing technology has a graded macroporous-microporous microstructure and good cytocompatibility, which is conducive to cell adhesion and growth, laying the foundation for the in vivo research of tissue engineered meniscus scaffolds in the next step.


Asunto(s)
Menisco , Impresión Tridimensional , Ingeniería de Tejidos , Andamios del Tejido , Animales , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Porcinos , Ratas , Menisco/citología , Materiales Biocompatibles , Ratas Sprague-Dawley , Células Cultivadas , Meniscos Tibiales/citología , Microscopía Electrónica de Rastreo
5.
Int J Biol Macromol ; 263(Pt 1): 130237, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38368980

RESUMEN

Breast cancer has become the most diagnosed cancer type, endangering the health of women. Patients with breast resection are likely to suffer serious physical and mental trauma. Therefore, breast reconstruction becomes an important means of postoperative patient rehabilitation. Polyvinyl alcohol hydrogel has great potential in adipose tissue engineering for breast reconstruction. However, its application is limited because of the lack of bioactive factors and poor structural stability. In this study, we prepared biodegradable polylactic acid-glycolic acid copolymer/polycaprolactone/gelatin (PPG) nanofibers. We then combined them with polyvinyl alcohol/collagen to create tissue engineering scaffolds to overcome limitations. We found that PPG fibers formed amide bonds with polyvinyl alcohol/collagen scaffolds. After chemical crosslinking, the number of amide bonds increased, leading to a significant improvement in their mechanical properties and thermal stability. The results showed that compared with pure PVA scaffolds, the maximum compressive stress of the scaffold doped with 0.9 g nanofibers increased by 500 %, and the stress loss rate decreased by 40.6 % after 10 cycles of compression. The presence of natural macromolecular gelatin and the changes in the pore structure caused by nanofibers provide cells with richer and more three-dimensional adsorption sites, allowing them to grow in three dimensions on the scaffold. So, the hydrogel scaffold by reinforcing polyvinyl alcohol hydrogel with PPG fibers is a promising breast reconstruction method.


Asunto(s)
Gelatina , Nanofibras , Humanos , Femenino , Gelatina/química , Ingeniería de Tejidos/métodos , Alcohol Polivinílico/química , Nanofibras/química , Colágeno/química , Andamios del Tejido/química , Poliésteres/química , Amidas
6.
J Transl Med ; 11: 303, 2013 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-24330728

RESUMEN

It is now 40 years since bisphosphonates (BPs) were first used in the clinic. So, it is timely to provide a brief review of what we have learned about these agents in bone disease. BPs are bone-specific and have been classified into two major groups on the basis of their distinct molecular modes of action: amino-BPs and non-amino-BPs. The amino-BPs are more potent and they inhibit farnesyl pyrophosphate synthase (FPPS), a key enzyme of the mavalonate/cholesterol biosynthetic pathway, while the non-amino-BPs inhibit osteoclast activity, by incorporation into non-hydrolyzable analogs of ATP. Both amino-BPs and non-amino-BPs can protect osteoblasts and osteocytes against apoptosis. The BPs are widely used in the clinic to treat various diseases characterized by excessive bone resorption, including osteoporosis, myeloma, bone metastasis, Legg-Perthes disease, malignant hyperparathyroidism, and other conditions featuring bone fragility. This review provides insights into some of the adverse effects of BPs, such as gastric irritation, osteonecrosis of the jaw, atypical femoral fractures, esophageal cancer, atrial fibrillation, and ocular inflammation. In conclusion, this review covers the biochemical and molecular mechanisms of action of BPs in bone, particularly the discovery that BPs have direct anti-apoptotic effects on osteoblasts and osteocytes, and the current situation of BP use in the clinic.


Asunto(s)
Enfermedades Óseas/tratamiento farmacológico , Difosfonatos/uso terapéutico , Difosfonatos/efectos adversos , Difosfonatos/farmacocinética , Humanos , Distribución Tisular
7.
J Mater Chem B ; 10(7): 1116-1127, 2022 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-35103745

RESUMEN

The need for a wound dressing material that can accelerate wound healing is increasing and will last for a long time. In this study, cerium oxide nanoparticle (CeNP) incorporated poly-L-lactic acid (PLLA)-gelatin composite fiber membranes were fabricated using established electrospinning techniques for use as a low-cost sustainable wound dressing material. The obtained membranes were characterized for their morphology, and physical, mechanical and biological properties. The results showed that the membranes maintained an integrated morphology, and demonstrated water absorption and improved mechanical properties. An in vitro cell proliferation test confirmed that the cells presented better activities over the composite fiber membranes. In the rat scalding model, rapid wound recombination was observed. All these data suggested that electrospun CeNP incorporated PLLA-gelatin composite fiber membranes can be an ideal dressing substitute that can be used for wound healing applications. Furthermore, the use of biodegradable polymers and environmentally sustainable production technologies presented better sustainability for the commercial production of these composite membranes promoting tissue regeneration and scar remodeling.


Asunto(s)
Cicatriz , Gelatina , Animales , Vendajes , Poliésteres , Ratas
8.
Int J Biol Macromol ; 217: 180-187, 2022 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-35835300

RESUMEN

Rotator cuff repair remains a challenge clinically due to the high retear rate after surgical intervention. There is a significant need to develop functional biomaterials facilitating tendon-to-bone integration. In this study, hydroxyapatite (HA) incorporated polylactic acid (PLLA) aligned nanofibrous membranes were fabricated by electrospinning as a low-cost sustainable rotator cuff patch. The morphology, physical, mechanical and in vitro cell assays of the nanofibrous membranes were characterized. The results showed that the nanofibrous membrane maintained a rough surface and weakened hydrophobicity. It has excellent cytocompatibility, and the cells were oriented along the direction of fiber arrangement. What's more, the PLLA-HA nanofibrous membrane could increase the alkaline phosphatase (ALP) expression in rat bone marrow mesenchymal stem cells (BMSCs), indicating that the electrospinning PLLA-HA nanofibrous membrane can better induce the bone formation of rat BMSCs cells. When the mass ratio of PLLA to HA exceeds 3: 1, with the increase of the HA content, the patch showed rising induction ability. The results suggested that electrospinning PLLA-HA nanofibrous membranes are an ideal patch for promoting tendon-bone healing and reducing the secondary tear rate. Furthermore, the use of biodegradable polymers and low-cost preparation methods presented the possibility for commercial production of these nanofibrous membranes.


Asunto(s)
Nanofibras , Animales , Durapatita , Poliésteres/farmacología , Ratas , Manguito de los Rotadores , Ingeniería de Tejidos/métodos , Andamios del Tejido
9.
J Mater Sci Mater Med ; 22(3): 693-704, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21287238

RESUMEN

An ideal scaffold for cartilage tissue engineering should be biomimetic in not only mechanical property and biochemical composition, but also the morphological structure. In this research, we fabricated a composite scaffold with oriented structure to mimic cartilage physiological morphology, where natural nanofibrous articular cartilage extracellular matrix (ACECM) was used to mimic the biochemical composition, and synthetic PLGA was used to enhance the mechanical strength of ACECM. The composite scaffold has well oriented structure and more than 89% of porosity as well as about 107 µm of average pore diameter. The composite scaffold was compared with ACECM and PLGA scaffolds. Cell proliferation test showed that the number of MSCs in ACECM and composite scaffolds was noticeably bigger than that in PLGA scaffold, which was coincident with results of SEM observation and cell viability staining. The water absorption of ACECM and composite scaffolds were 22.1 and 10.2 times respectively, which was much higher than that of PLGA scaffolds (3.8 times). The compressive modulus of composite scaffold in hydrous status was 1.03 MPa, which was near 10 times higher than that of hydrous ACECM scaffold. The aforementioned results suggested that the composite scaffold has the potential for application in cartilage tissue engineering.


Asunto(s)
Biomimética , Cartílago Articular/metabolismo , Matriz Extracelular/metabolismo , Ácido Láctico/química , Ácido Poliglicólico/química , Andamios del Tejido/química , Animales , Proliferación Celular , Supervivencia Celular , Inmunohistoquímica/métodos , Células Madre Mesenquimatosas/citología , Microscopía Electrónica de Rastreo/métodos , Nanoestructuras/química , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Porosidad , Conejos , Estrés Mecánico , Ingeniería de Tejidos/métodos
10.
Tissue Eng Part B Rev ; 27(3): 266-293, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32988289

RESUMEN

The meniscus plays a critical role in maintaining knee joint homeostasis. Injuries to the meniscus, especially considering the limited self-healing capacity of the avascular region, continue to be a challenge and are often treated by (partial) meniscectomy, which has been identified to cause osteoarthritis. Currently, meniscus tissue engineering focuses on providing extracellular matrix (ECM)-mimicking scaffolds to direct the inherent meniscal regeneration process, and it has been found that various stimuli are essential. Numerous bioactive factors present benefits in regulating cell fate, tissue development, and healing, but lack an optimal delivery system. More recently, bioengineers have developed various polymer-based drug delivery systems (PDDSs), which are beneficial in terms of the favorable properties of polymers as well as novel delivery strategies. Engineered PDDSs aim to provide not only an ECM-mimicking microenvironment but also the controlled release of bioactive factors with release profiles tailored according to the biological concerns and properties of the factors. In this review, both different polymers and bioactive factors involved in meniscal regeneration are discussed, as well as potential candidate systems, with examples of recent progress. This article aims to summarize drug delivery strategies in meniscal regeneration, with a focus on novel delivery strategies rather than on specific delivery carriers. The current challenges and future prospects for the structural and functional regeneration of the meniscus are also discussed. Impact statement Meniscal injury remains a clinical Gordian knot owing to the limited healing potential of the region, restricted surgical approaches, and risk of inducing osteoarthritis. Existing tissue engineering scaffolds that provide mechanical support and a favorable microenvironment also lack biological cues. Advanced polymer-based delivery strategies consisting of polymers incorporating bioactive factors have emerged as a promising direction. This article primarily reviews the types and applications of biopolymers and bioactive factors in meniscal regeneration. Importantly, various carrier systems and drug delivery strategies are discussed with the hope of inspiring further advancements in this field.


Asunto(s)
Menisco , Preparaciones Farmacéuticas , Polímeros , Regeneración , Ingeniería de Tejidos
11.
Biomaterials ; 278: 121131, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34543785

RESUMEN

Articular cartilage (AC) injury repair has always been a difficult problem for clinicians and researchers. Recently, a promising therapy based on mesenchymal stem cells (MSCs) has been developed for the regeneration of cartilage defects. As endogenous articular stem cells, synovial MSCs (SMSCs) possess strong chondrogenic differentiation ability and articular specificity. In this study, a cartilage regenerative system was developed based on a chitosan (CS) hydrogel/3D-printed poly(ε-caprolactone) (PCL) hybrid containing SMSCs and recruiting tetrahedral framework nucleic acid (TFNA) injected into the articular cavity. TFNA, which is a promising DNA nanomaterial for improving the regenerative microenvironment, could be taken up into SMSCs and promoted the proliferation and chondrogenic differentiation of SMSCs. CS, as a cationic polysaccharide, can bind to DNA through electrostatic action and recruit free TFNA after articular cavity injection in vivo. The 3D-printed PCL scaffold provided basic mechanical support, and TFNA provided a good microenvironment for the proliferation and chondrogenic differentiation of the delivered SMSCs and promoted cartilage regeneration, thus greatly improving the repair of cartilage defects. In conclusion, this study confirmed that a CS hydrogel/3D-printed PCL hybrid scaffold containing SMSCs could be a promising strategy for cartilage regeneration based on chitosan-directed TFNA recruitment and TFNA-enhanced cell proliferation and chondrogenesis.


Asunto(s)
Cartílago Articular , Quitosano , Células Madre Mesenquimatosas , Ácidos Nucleicos , Diferenciación Celular , Condrogénesis , Hidrogeles , Poliésteres , Impresión Tridimensional , Regeneración , Ingeniería de Tejidos , Andamios del Tejido
12.
Biomed Mater ; 15(5): 055027, 2020 08 21.
Artículo en Inglés | MEDLINE | ID: mdl-32498062

RESUMEN

A mini or partial arthroplasty may offer the advantages of reduced pain, shorter hospital stay, and increased range of motion, which are beneficial for the treatment of large-sized focal osteochondral defects. We aimed to evaluate the in vivo histologic response and function of our nonresorbable, composite structure implant, developed using polyetheretherketone (PEEK) and Ti6AI4V alloy, as a treatment for full-thickness osteochondral defects in the femoral head of the hip using a goat model. The gross and imaging appearance and histologic results were compared to those of a similar size cobalt-chromium-molybdenum (CoCrMo) alloy implant placed in a defect in the femoral head and evaluated up to 12 weeks. The X radiographs showed that there was no evidence of loosening of the implants for both the PEEK-Ti6AI4V and CoCrMo groups. Magnetic resonance imaging results showed no inflammatory signal findings in both PEEK-Ti6AI4V and CoCrMo implants. Macroscopically and histologically, there was lesser cartilage degeneration in the PEEK-Ti6AI4V implant than in the CoCrMo implant. The modified macroscopic articular evaluation score was lower in the PEEK-Ti6AI4V group than in the CoCrMo group (p < 0.05), and the histological score of the periprosthetic and acetabular cartilage was lower in the PEEK-Ti6AI4V group than in the CoCrMo group (P < 0.05). The micro-computed tomography results showed that the uncemented PEEK-Ti6AI4V implant has better osseointegration and higher bone-implant contact than the cemented CoCrMo implant. The peri-implant bone mass was higher in the PEEK-Ti6AI4V implant(p < 0.05). Meanwhile, the optical profile analytical results showed that the surface roughness of the cartilage in the acetabulum was higher in the CoCrMo group. In conclusion, the mini-arthroplasty implant based on PEEK-Ti6AI4V was superior to an identical CoCrMo alloy implant as a treatment for local osteochondral defect in the femoral head, owing to its in vivo cartilage protection and better osseointegration.


Asunto(s)
Aleaciones/química , Artroplastia/instrumentación , Artroplastia/métodos , Benzofenonas/química , Sustitutos de Huesos , Cabeza Femoral/efectos de los fármacos , Osteoblastos/efectos de los fármacos , Polímeros/química , Titanio/química , Animales , Cartílago Articular/efectos de los fármacos , Cabras , Inflamación , Oseointegración , Prótesis e Implantes , Propiedades de Superficie , Microtomografía por Rayos X
13.
Microsurgery ; 29(4): 330-6, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19296502

RESUMEN

Previous studies have demonstrated the potential of growth factors in peripheral nerve regeneration. A method was developed for sustained delivery of nerve growth factor (NGF) for nerve repair with acellular nerve grafts to augment peripheral nerve regeneration. NGF-containing polymeric microspheres were fixed with fibrin glue around chemically extracted acellular nerve grafts for prolonged, site-specific delivery of NGF. A total of 52 Wistar rats were randomly divided into four groups for treatment: autografting, NGF-treated acellular grafting, acellular grafting alone, and acellular grafting with fibrin glue. The model of a 10-mm sciatic nerve with a 10-mm gap was used to assess nerve regeneration. At the 2nd week after nerve repair, the length of axonal regeneration was longer with NGF-treated acellular grafting than acellular grafting alone and acellular grafting with fibrin glue, but shorter than autografting (P < 0.05). Sixteen weeks after nerve repair, nerve regeneration was assessed functionally and histomorphometrically. The percentage tension of the triceps surae muscles in the autograft group was 85.33 +/- 5.59%, significantly higher than that of NGF-treated group, acellular graft group and fibrin-glue group, at 69.79 +/- 5.31%, 64.46 +/- 8.48%, and 63.35 +/- 6.40%, respectively (P < 0.05). The ratio of conserved muscle-mass was greater in the NGF-treated group (53.73 +/- 4.56%) than in the acellular graft (46.37 +/- 5.68%) and fibrin glue groups (45.78 +/- 7.14%) but lower than in the autograft group (62.54 +/- 8.25%) (P < 0.05). Image analysis on histological observation revealed axonal diameter, axon number, and myelin thickness better with NGF-treated acellular grafting than with acellular grafting alone and acellular grafting with fibrin glue (P < 0.05). There were no significant differences between NGF-treated acellular grafting and autografting. This method of sustained site-specific delivery of NGF can enhance peripheral nerve regeneration across short nerve gaps repaired with acellular nerve grafts.


Asunto(s)
Microcirugia/métodos , Factor de Crecimiento Nervioso/administración & dosificación , Regeneración Nerviosa/efectos de los fármacos , Procedimientos de Cirugía Plástica/métodos , Nervio Ciático/trasplante , Animales , Adhesivo de Tejido de Fibrina/administración & dosificación , Masculino , Microesferas , Ratas , Ratas Wistar , Procedimientos de Cirugía Plástica/instrumentación , Nervio Ciático/fisiología , Adhesivos Tisulares/administración & dosificación , Trasplante Homólogo/instrumentación , Trasplante Homólogo/métodos
14.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 33(8): 1011-1018, 2019 Aug 15.
Artículo en Zh | MEDLINE | ID: mdl-31407562

RESUMEN

OBJECTIVE: To manufacture a poly (lactic-co-glycolic acid) (PLGA) scaffold by low temperature deposition three-dimensional (3D) printing technology, prepare a PLGA/decellularized articular cartilage extracellular matrix (DACECM) cartilage tissue engineered scaffold by combining DACECM, and further investigate its physicochemical properties. METHODS: PLGA scaffolds were prepared by low temperature deposition 3D printing technology, and DACECM suspensions was prepared by modified physical and chemical decellularization methods. DACECM oriented scaffolds were prepared by using freeze-drying and physicochemical cross-linking techniques. PLGA/DACECM oriented scaffolds were prepared by combining DACECM slurry with PLGA scaffolds. The macroscopic and microscopic structures of the three kinds of scaffolds were observed by general observation and scanning electron microscope. The chemical composition of DACECM oriented scaffold was analyzed by histological and immunohistochemical stainings. The compression modulus of the three kinds of scaffolds were measured by biomechanical test. Three kinds of scaffolds were embedded subcutaneously in Sprague Dawley rats, and HE staining was used to observe immune response. The chondrocytes of New Zealand white rabbits were isolated and cultured, and the three kinds of cell-scaffold complexes were prepared. The growth adhesion of the cells on the scaffolds was observed by scanning electron microscope. Three kinds of scaffold extracts were cultured with L-929 cells, the cells were cultured in DMEM culture medium as control group, and cell counting kit 8 (CCK-8) was used to detect cell proliferation. RESULTS: General observation and scanning electron microscope showed that the PLGA scaffold had a smooth surface and large pores; the surface of the DACECM oriented scaffold was rough, which was a 3D structure with loose pores and interconnected; and the PLGA/DACECM oriented scaffold had a rough surface, and the large hole and the small hole were connected to each other to construct a vertical 3D structure. Histological and immunohistochemical qualitative analysis demonstrated that DACECM was completely decellularized, retaining the glycosaminoglycans and collagen typeⅡ. Biomechanical examination showed that the compression modulus of DACECM oriented scaffold was significantly lower than those of the other two scaffolds ( P<0.05). There was no significant difference between PLGA scaffold and PLGA/DACECM oriented scaffold ( P>0.05). Subcutaneously embedded HE staining of the three scaffolds showed that the immunological rejections of DACECM and PLGA/DACECM oriented scaffolds were significantly weaker than that of the PLGA scaffold. Scanning electron microscope observation of the cell-scaffold complex showed that chondrocytes did not obviously adhere to PLGA scaffold, and a large number of chondrocytes adhered and grew on PLGA/DACECM oriented scaffold and DACECM oriented scaffold. CCK-8 assay showed that with the extension of culture time, the number of cells cultured in the three kinds of scaffold extracts and the control group increased. There was no significant difference in the absorbance ( A) value between the groups at each time point ( P>0.05). CONCLUSION: The PLGA/DACECM oriented scaffolds have no cytotoxicity, have excellent physicochemical properties, and may become a promising scaffold material of tissue engineered cartilage.


Asunto(s)
Cartílago Articular , Andamios del Tejido , Animales , Células Cultivadas , Matriz Extracelular , Glicolatos , Glicoles , Ácido Láctico , Ácido Poliglicólico , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Impresión Tridimensional , Conejos , Ratas , Ratas Sprague-Dawley
15.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 33(5): 628-633, 2019 May 15.
Artículo en Zh | MEDLINE | ID: mdl-31090359

RESUMEN

OBJECTIVE: Electrospinning technique was used to manufacture polycaprolactone (PCL)/collagen typeⅠ nanofibers orientated patches and to study their physical and chemical characterization, discussing their feasibility as synthetic patches for rotator cuff repairing. METHODS: PCL patches were prepared by electrospinning with 10% PCL electrospinning solution (control group) and PCL/collagen typeⅠorientated nanofibers patches were prepared by electrospinning with PCL electrospinning solution with 25% collagen type Ⅰ(experimental group). The morphology and microstructure of the two patches were observed by gross and scanning electron microscopy, and the diameter and porosity of the fibers were measured; the mechanical properties of the patches were tested by uniaxial tensile test; the composition of the patches was analyzed by Fourier transform infrared spectroscopy; and the contact angle of the patch surface was measured. Two kinds of patch extracts were co-cultured with the third generation of rabbit tendon stem cells. Cell counting kit 8 (CCK-8) was used to detect the toxicity and cell proliferation of the materials. Normal cultured cells were used as blank control group. Rabbit tendon stem cells were co-cultured with the two patches and stained with dead/living cells after 3 days of in vitro culture, and laser confocal scanning microscopy was used to observe the cell adhesion and activity on the patch. RESULTS: Gross and scanning electron microscopy showed that the two patch fibers were arranged in orientation. The diameter of patch fibers in the experimental group was significantly smaller than that in the control group ( t=26.907, P=0.000), while the porosity in the experimental group was significantly larger than that in the control group ( t=2.506, P=0.032). The tensile strength and Young's modulus of the patch in the experimental group were significantly higher than those in the control group ( t=3.705, P=0.029; t=4.064, P=0.034). Infrared spectrum analysis showed that PCL and collagen type Ⅰ were successfully mixed in the experimental group. The surface contact angle of the patch in the experimental group was (73.88±4.97)°, which was hydrophilic, while that in the control group was (128.46±5.10) °, which was hydrophobic. There was a significant difference in the surface contact angle between the two groups ( t=21.705, P=0.002). CCK-8 test showed that with the prolongation of culture time, the cell absorbance ( A) value increased gradually in each group, and there was no significant difference between the experimental group and the control group at each time point ( P>0.05). Laser confocal scanning microscopy showed that rabbit tendon stem cells could adhere and grow on the surface of both patches after 3 days of culture. The number of cells adhered to the surface of the patches in the experimental group was more than that in the control group, and the activity was better. CONCLUSION: PCL/ collagen type Ⅰ nanofibers orientated patch prepared by electrospinning technology has excellent physical and chemical properties, cell adhesion, and no cytotoxicity. It can be used as an ideal scaffold material in tendon tissue engineering for rotator cuff repair in the future.


Asunto(s)
Nanofibras , Manguito de los Rotadores , Andamios del Tejido , Animales , Proliferación Celular , Colágeno , Poliésteres , Conejos , Ingeniería de Tejidos
16.
ACS Appl Mater Interfaces ; 11(44): 41626-41639, 2019 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-31596568

RESUMEN

Regeneration of an injured meniscus continues to be a scientific challenge due to its poor self-healing potential. Tissue engineering provides an avenue for regenerating a severely damaged meniscus. In this study, we first investigated the superiority of five concentrations (0%, 0.5%, 1%, 2%, and 4%) of meniscus extracellular matrix (MECM)-based hydrogel in promoting cell proliferation and the matrix-forming phenotype of meniscal fibrochondrocytes (MFCs). We found that the 2% group strongly enhanced chondrogenic marker mRNA expression and cell proliferation compared to the other groups. Moreover, the 2% group showed the highest glycosaminoglycan (GAG) and collagen production by day 14. We then constructed a hybrid scaffold by 3D printing a wedge-shaped poly(ε-caprolactone) (PCL) scaffold as a backbone, followed by injection with the optimized MECM-based hydrogel (2%), which served as a cell delivery system. The hybrid scaffold (PCL-hydrogel) clearly yielded favorable biomechanical properties close to those of the native meniscus. Finally, PCL scaffold, PCL-hydrogel, and MFCs-loaded hybrid scaffold (PCL-hydrogel-MFCs) were implanted into the knee joints of New Zealand rabbits that underwent total medial meniscectomy. Six months postimplantation we found that the PCL-hydrogel-MFCs group exhibited markedly better gross appearance and cartilage protection than the PCL scaffold and PCL-hydrogel groups. Moreover, the regenerated menisci in the PCL-hydrogel-MFCs group had similar histological structures, biochemical contents, and biomechanical properties as the native menisci in the sham operation group. In conclusion, PCL-MECM-based hydrogel hybrid scaffold seeded with MFCs can successfully promote whole meniscus regeneration, and cell-loaded PCL-MECM-based hydrogel hybrid scaffold may be a promising strategy for meniscus regeneration in the future.


Asunto(s)
Matriz Extracelular/química , Hidrogeles/química , Menisco/fisiología , Poliésteres/química , Regeneración , Andamios del Tejido/química , Animales , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Condrocitos/citología , Condrocitos/metabolismo , Modelos Animales de Enfermedad , Hidrogeles/farmacología , Meniscectomía , Menisco/citología , Menisco/cirugía , Porosidad , Impresión Tridimensional , Conejos , Resistencia a la Tracción , Ingeniería de Tejidos
17.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 32(9): 1205-1210, 2018 09 15.
Artículo en Zh | MEDLINE | ID: mdl-30129332

RESUMEN

Objective: To manufacture a polycaprolactone (PCL)/type Ⅰ collagen (COL Ⅰ) tissue engineered meniscus scaffold (hereinafter referred to as PCL/COL Ⅰ meniscus scaffold) by three-dimensional (3D) printing with low temperature deposition technique and to study its physicochemical properties. Methods: First, the 15% PCL/4% COLⅠ composite solution and 15% PCL simple solution were prepared. Then, 15% PCL/4% COL Ⅰmeniscus scaffold and 15% PCL meniscal scaffold were prepared by using 3D printing with low temperature deposition techniques. The morphology and microstructure of the scaffolds were observed by gross observation and scanning electron microscope. The compression modulus and tensile modulus of the scaffolds were measured by biomechanical test. The components of the scaffolds were analyzed by Fourier transform infrared spectroscopy (FTIR). The contact angle of the scaffold surface was measured. The meniscus cells of rabbits were cultured with the two scaffold extracts and scaffolds, respectively. After cultured, the cell proliferations were detected by cell counting kit 8 (CCK-8), and the normal cultured cells were used as controls. Cell adhesion and growth of scaffold-cell complex were observed by scanning electron microscope. Results: According to the gross and scanning electron microscope observations, two scaffolds had orientated 3D microstructures and pores, but the surface of the PCL/COLⅠ meniscus scaffold was rougher than the PCL meniscus scaffold. Biomechanical analysis showed that the tensile modulus and compression modulus of the PCL/COL Ⅰ meniscus scaffold were not significantly different from those of the PCL meniscus scaffold ( P>0.05). FTIR analysis results showed that COL Ⅰ and PCL were successful mixed in PCL/ COL Ⅰ meniscus scaffolds. The contact angle of PCL/COLⅠ meniscus scaffold [(83.19±7.49)°] was significantly lower than that of PCL meniscus scaffold [(111.13±5.70)°] ( t=6.638, P=0.000). The results of the CCK-8 assay indicated that with time, the number of cells cultured in two scaffold extracts showed an increasing trend, and there was no significant difference when compared with the control group ( P>0.05). Scanning electron microscope observation showed that the cells attached on the PCL/ COL Ⅰ meniscus scaffold more than that on the PCL scaffold. Conclusion: PCL/COLⅠmeniscus scaffolds are prepared by 3D printing with low temperature deposition technique, which has excellent physicochemical properties without cytotoxicity. PCL/COLⅠmeniscus scaffold is expected to be used as the material for meniscus tissue engineering.


Asunto(s)
Impresión Tridimensional , Animales , Adhesión Celular , Proliferación Celular , Células Cultivadas , Colágeno Tipo I , Menisco , Poliésteres , Conejos , Ingeniería de Tejidos , Andamios del Tejido
18.
J Biomater Sci Polym Ed ; 29(5): 461-475, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29308701

RESUMEN

Meniscus is a fibrocartilaginous organ to redistribute stress and enhance the stability of knee joint. Meniscus injury is common and still a formidable challenge to orthopedic surgeons. Surgical techniques and allograft transplantation were primary approaches to meniscus repair, but with intrinsic limitations in clinical practice. Tissue engineering is the most promising method to repair meniscus at present. Electrospinning is a method to fabricate fibers in small scale. With different materials and parameters, electrospinning materials could have different mechanical properties, porosity, and orientation, which could mimic architectural features and mechanical properties of native meniscus. Therefore, electrospinning materials could be used in meniscus regeneration and curing. This review gave a brief introduction of meniscus structure, injury, treatment and the application of electrospinning fibers in meniscus tissue engineering and curing. Besides that, we summarized materials commonly used in electrospinning to fabricate meniscus scaffolds, and discussed the form of electrospinning fibers used such as scaffold, substitute and patch. Finally, the function of electrospinning fibers, for example, carrying drugs, providing mechanical properties were described. The potential applications of electrospinning fibers in meniscus therapy were proposed.


Asunto(s)
Electricidad , Menisco/citología , Ingeniería de Tejidos/métodos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Humanos , Fenómenos Mecánicos , Menisco/efectos de los fármacos , Polímeros/química , Polímeros/farmacología
19.
Acta Biomater ; 73: 127-140, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29654991

RESUMEN

Low vascularization in meniscus limits its regeneration ability after injury, and tissue engineering is the most promising method to achieve meniscus regeneration. In this study, we fabricated a kind of composite scaffold by decellularized meniscus extracellular matrix/polycaprolactone (DMECM/PCL) electrospinning fibers and porous DMECM, in which DMECM/PCL fibers were used as reinforcing component. The tensile modulus of the composite scaffold in longitudinal and crosswise directions were 8.5 ±â€¯1.9 and 2.3 ±â€¯0.3 MPa, respectively. Besides that, the DMECM/PCL electrospinning fibers enhanced suture resistance of the composite scaffold more than 5 times than DMECM scaffold effectively. In vitro cytocompatibility showed that the porous structure provided by DMECM component facilitated meniscus cells' proliferation. DMECM was also the main component to regulate cell behaviors, which promoted meniscus cells expressing extracellular matrix related genes such as COL I, COL II, SOX9 and AGG. Rabbits with total meniscectomy were used as animal model to evaluated the composited scaffolds performance in vivo at 3 and 6 months. Results showed that rabbits with scaffold implanting could regenerate neo-menisci in both time points. The neo-menisci had similar histology structure and biochemical content with native menisci. Although neo-menisci had inferior tensile modulus than native ones, its modulus was improved with implanting time prolonging. MRI imaging showed the signal of neo-meniscus in the body is clear, and X-ray imaging of knee joints demonstrated the implantation of scaffolds could relief joint space narrowing. Moreover, rabbits with neo-menisci had better cartilage condition in femoral condyle and tibial plateau compared than meniscectomy group. STATEMENT OF SIGNIFICANCE: We fabricated the meniscus scaffold by combining porous decellularized meniscus extracellular matrix (DMECM) and DMECM/PCL electrospinning fibers together, which used the porous structure of DMECM, and the good tensile property of electrospinning fibers. We believe single material cannot satisfy increasing needs of scaffold. Therefore, we combined not only materials but also fabrication methods together to develop scaffold to make good use of each part. DMECM in electrospinning fibers also made these two components possible to be integrated through crosslinking. Compared to existing meniscus scaffold, the composite scaffold had (1) soft structure and extrusion would not happen after implantation, (2) ability to be trimmed to suitable shape during surgery, and (3) good resistance to suture.


Asunto(s)
Matriz Extracelular , Meniscectomía , Menisco , Poliésteres , Ingeniería de Tejidos , Andamios del Tejido/química , Animales , Modelos Animales de Enfermedad , Matriz Extracelular/química , Matriz Extracelular/trasplante , Menisco/lesiones , Menisco/metabolismo , Menisco/patología , Menisco/cirugía , Poliésteres/química , Poliésteres/farmacología , Conejos
20.
Adv Healthc Mater ; 7(17): e1800276, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30044554

RESUMEN

Autologous nerve grafting (ANG), the gold standard treatment for peripheral nerve defects, still has many restrictions. In this study, the acellular cauda equina allograft (ACEA), which consists of biodegradable chitin conduit and acellular cauda equina, is developed. The cauda equina is able to complete decellularization more quickly and efficiently than sciatic nerves under the same conditions, and it is able to reserve more basal lamina tube. In vitro, ACEA shows superior guidance capacity for the regeneration of axons and migration of Schwann cells compared to acellular sciatic nerve allograft (ASNA) in dorsal root ganglion culture. In vivo, ACEA is used to bridge 15 mm long-distance defects in rat sciatic nerves. On day 21 after transplantation, the regenerative distance of neurofilaments in the grafting segment is not significantly different between the ACEA and ANG groups. At week 12, ACEA group shows better sciatic nerve repair than chitin conduit only and ASNA groups, and the effect is similar to that in the ANG group as determined by gait analysis, neural electrophysiological, and histological analyses. The above results suggest that the ACEA has the potential to become a new biological material as a replacement for autografting in the treatment of long-distance nerve defects.


Asunto(s)
Cauda Equina/citología , Cauda Equina/cirugía , Quitina/metabolismo , Nervio Ciático/cirugía , Aloinjertos , Animales , Axones/metabolismo , Materiales Biocompatibles/química , Masculino , Regeneración Nerviosa/fisiología , Ratas , Ratas Sprague-Dawley , Células de Schwann/metabolismo , Nervio Ciático/citología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA