Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Oral Implantol ; 46(3): 206-213, 2020 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-32030398

RESUMEN

The aim of this ex vivo study was to compare the diagnostic performances of panoramic radiography and cone beam computerized tomography (CBCT) in detecting implant-related injuries of the inferior alveolar canal. Monocortical bone windows were created in 60 fresh sheep hemimandibles, the inferior alveolar canals were revealed and 120 dental implants were inserted. Three types of injuries, described as pilot drill damage (PDRILL), collapsing of the superior border of the canal (COLL), penetration of the implant tip into the canal (PENET) and one control group, were simulated. Standard (PANO) and dentition mode panoramic (PANO-DENT) images as well as CBCT data presented as multiplanar reconstruction (MPR) and cross-sectional (CROSS) views were evaluated by 6 observers who had also expressed their level of confidence to their final diagnosis. Intra- and interobserver agreement scores were rated good. The area under the curve (AUC) values and the confidence scores for CROSS and multiplanar reformation (MPR) views were both significantly higher than those of PANO and PANO-DENT (P < .05 for each) in PDRILL group. In COLL group, observers showed less confidence to PANO and PANO-DENT compared to CROSS and MPR techniques (P < .05 for each). No other significant differences were found. Within the limits of this experimental study, it can be suggested that the standard and dentition modes of panoramic radiography can be as effective as CBCT in the detection of penetrating and collapsing injuries, but multiplanar and cross-sectional views of the CBCT are more accurate than panoramic radiography in the detection of pilot drill injuries in sheep mandible.


Asunto(s)
Implantes Dentales , Tomografía Computarizada de Haz Cónico Espiral , Animales , Tomografía Computarizada de Haz Cónico , Estudios Transversales , Mandíbula , Radiografía Panorámica , Ovinos
2.
J Oral Maxillofac Surg ; 70(7): 1540-50, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22698290

RESUMEN

PURPOSE: The aim of this study was to compare the diagnostic potentials and practical advantages of different imaging modalities in detecting bone defects around dental implants. MATERIALS AND METHODS: Crestal bone defects with sequentially larger diameters were randomly prepared around 100 implants that were inserted in bovine bone blocks. Conventional periapical radiography (PR), direct digital radiography (DDR), panoramic radiography (PANO), cone-beam computed tomography (CBCT), and multislice computed tomography (MSCT) were performed for all specimens. The diagnostic accuracies of the devices, confidence of the answers, subjective image quality, defect visibility in planar orientations, and duration of diagnosis were analyzed based on the interpretations of 7 calibrated observers. RESULTS: The agreement levels of intra- and interobserver scores were rated good. PR, DDR, and CBCT were mostly more accurate than PANO and MSCT (P < .05). Confidence levels were positively correlated with the defect size (ρ = 0.20, P < .01), and that of DDR was the highest (P < .05). The subjective image quality of PR and DDR was higher than that of CBCT, PANO, and MSCT (P < .05 for all comparisons). Axial-coronal-sagittal visibilities of the defects were higher for CBCT compared with MSCT (P < .05). The diagnostic time was shorter for DDR (P < .05) and longer for the tomographic systems (P < .05) than for the other devices. CONCLUSIONS: DDR may provide a faster and more confident diagnostic option that is as accurate as PR in detecting peri-implant radiolucencies. CBCT has a comparable potential to these intraoral systems but with slower decision making and lower image quality, whereas PANO and MSCT become more reliable when bone defects have a diameter that is at least 1.5 mm larger than that of the implant.


Asunto(s)
Enfermedades Óseas/diagnóstico por imagen , Implantes Dentales , Animales , Bovinos , Tomografía Computarizada de Haz Cónico/normas , Toma de Decisiones , Diseño de Prótesis Dental , Tomografía Computarizada Multidetector/normas , Variaciones Dependientes del Observador , Fantasmas de Imagen , Curva ROC , Intensificación de Imagen Radiográfica/normas , Radiografía de Mordida Lateral/normas , Radiografía Dental Digital/normas , Radiografía Panorámica/normas , Distribución Aleatoria , Factores de Tiempo
3.
Artículo en Inglés | MEDLINE | ID: mdl-30415905

RESUMEN

OBJECTIVE: The aim of this study was to compare the diagnostic efficacy of panoramic radiography (PANO) and cone beam computed tomography (CBCT) in detecting simulated complications of plate osteosynthesis applied to mandibular angle fractures (MAFs). STUDY DESIGN: Unfavorable MAFs were created in 100 fresh sheep hemimandibles. Fractures were fixed with 4-hole titanium miniplates and screws. Bone necrosis around the screws, penetration of the screw into the inferior alveolar canal, screw loosening, and plate breakage were simulated. The diagnostic efficacy of the imaging techniques was compared by using intra- and interobserver agreement scores and area under the receiver operating characteristic curve (AUC) values. Examination time (ET), confidence scores (CS), and planar preference (PP) in CBCT evaluation were assessed. RESULTS: Intra- and interobserver agreement scores varied between 0.61 and 0.91. AUCs for screw penetration into the inferior alveolar canal and screw loosening were significantly higher in CBCT than in PANO (P < .05). CBCT presented significantly higher ET and CS values compared with PANO (P < .05). PP showed significant differences among types of complications (P < .05). CONCLUSIONS: PANO provided acceptable outcomes in the detection of bone necrosis and broken plates around the screw, but CBCT was more likely to enable detection of all simulated types of complications with higher confidence.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Fijación Interna de Fracturas , Fracturas Mandibulares , Radiografía Panorámica , Animales , Placas Óseas , Fracturas Mandibulares/diagnóstico por imagen , Ovinos
4.
Artículo en Inglés | MEDLINE | ID: mdl-20889356

RESUMEN

OBJECTIVE: The objective of this study was to examine the diagnostic accuracy of the different secondary reconstruction slice thicknesses of cone beam computed tomography (CBCT) on artificially created mandibular condyle fractures. METHODS: A total of 63 sheep heads with or without condylar fractures were scanned with a NewTom 3G CBCT scanner. Multiplanar reformatted (MPR) views in 0.2-mm, 1-mm, 2-mm, and 3-mm secondary reconstruction slice thicknesses were evaluated by 7 observers. Inter- and intraobserver agreements were calculated with weighted kappa statistics. The receiver operating characteristic (ROC) curve analysis was used to statistically compare the area under the curve (AUC) of each slice thickness. RESULTS: The kappa coefficients varied from fair and to excellent. The AUCs of 0.2-mm and 1-mm slice thicknesses were found to be significantly higher than those of 2 mm and 3 mm for some type of fractures. CONCLUSION: CBCT was found to be accurate in detecting all variants of fractures at 0.2 mm and 1 mm. However, 2-mm and 3-mm slices were not suitable to detect fissure, complete, and comminuted types of mandibular condyle fractures.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Cóndilo Mandibular/lesiones , Fracturas Mandibulares/diagnóstico por imagen , Animales , Área Bajo la Curva , Tomografía Computarizada de Haz Cónico/estadística & datos numéricos , Fracturas Conminutas/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/estadística & datos numéricos , Luxaciones Articulares/diagnóstico por imagen , Cóndilo Mandibular/diagnóstico por imagen , Fracturas Mandibulares/clasificación , Variaciones Dependientes del Observador , Curva ROC , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Ovinos
5.
Cardiovasc Intervent Radiol ; 32(1): 159-62, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18677531

RESUMEN

Behcet's disease is a complex multisystemic chronic inflammatory disease that is characterized by oral and genital aphtous ulcers and vasculitis. Aneurysms of major arteries are the most important cause of mortality in Behcet's disease. Four patients with superior mesenteric artery (SMA) aneurysms related to Behcet's disease have been reported in the literature. We report here the first successful endovascular treatment of a giant, wide-necked SMA aneurysm secondary to Behcet's disease. We performed a balloon-assisted embolization technique using ethylene vinyl alcohol copolymer (Onyx, ev3, Irvine, CA, USA). There were no signs of recurrence during 2-year follow-up.


Asunto(s)
Aneurisma/terapia , Síndrome de Behçet/complicaciones , Arteria Mesentérica Superior , Polivinilos/uso terapéutico , Adulto , Aneurisma/etiología , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA