Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Dent ; 147: 105148, 2024 08.
Artículo en Inglés | MEDLINE | ID: mdl-38909648

RESUMEN

OBJECTIVE: This cohort study aimed to assess the incidence of somatosensory alterations after implant surgery using standardized quantitative and qualitative sensory testing. METHODS: 33 participants with single-tooth loss, undergoing immediate implant loading were included. Quantitative Sensory Testing (QST) and Qualitative Sensory Testing (QualST) were conducted at eight time points over a year (baseline to 1 year). Two-Way Repeated Measures ANOVA and post hoc Tukey test were used on QST values and Cochran Q test on QualST. RESULTS: The study revealed significant increase in thermal thresholds overtime. At the operated side, overall Cold Pain Threshold (extraoral: p = 0.030; intraoral: p < 0.001), and Cold Detection Threshold (intraoral: p < 0.001) increased overtime. In contralateral region, maxilla Cold Detection Threshold (extraoral: p = 0.024; intraoral: p = 0.031), Warm Detection Threshold (extraoral: p = 0.026; intraoral: p = 0.047) and overall Cold Pain Threshold (extraoral and intraoral: p < 0.001) also increased. QualST showed extraoral pinprick (p = 0.032) and intraoral pinprick (p = 0.000), cold (p = 0.000) and touch (p = 0.002) stimuli abnormalities overtime. CONCLUSIONS: Somatosensory alterations after implant surgery were detected in both quantitative and qualitative sensory assessments, but rapidly decreased during the first follow-ups, and then continuously until 1-year. CLINICAL SIGNIFICANCE: This study provides clinical and controlled evidence on the real effect of the somatosensory alterations overtime, leading to a better understanding of neurosensory behaviour after single-tooth dental implant rehabilitation.


Asunto(s)
Implantes Dentales de Diente Único , Carga Inmediata del Implante Dental , Umbral del Dolor , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios de Seguimiento , Adulto , Umbral del Dolor/fisiología , Anciano , Umbral Sensorial/fisiología , Frío , Estudios de Cohortes , Maxilar/cirugía , Trastornos Somatosensoriales/etiología
2.
J Stomatol Oral Maxillofac Surg ; 124(6S2): 101657, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37866505

RESUMEN

OBJECTIVE: This cross-sectional study aimed to evaluate the presence of bone changes on magnetic resonance imaging (MRI) scans of patients with temporomandibular joint (TMJ) anterior disc displacement (ADD) with reduction (ADDWR) and without reduction (ADDWoR). METHODS: TMJ-MRI scans were screened for the presence of ADD. 285 scans presented ADD, being further divided into ADDWR (n = 188) and ADDWoR (n = 97). Bone changes on the mandibular condyle and articular eminence were also assessed and computed. The chi-square test compared the association of these bone changes with the presence of ADDWR and ADDWoR, with a significance level of 5 %. Also, the prevalence ratio (PR) was calculated. RESULTS: In the mandibular condyle, subchondral cyst (p = 0.035, PR = 1.08) and bone edema (p = 0.044, PR = 2.40), more prevalent on ADDWR, and generalized sclerosis (p = 0.015, PR = 1.04), more prevalent on ADDWoR, presented significant association with ADD. On the articular eminence, generalized sclerosis (p = 0.015, PR = 1.04) and articular surface flattening (p = 0.003, PR = 1.19) presented significant association with ADD, both more prevalent on ADDWoR. CONCLUSION: Bone changes are usual findings in TMJ with ADD diagnosis. The real influence of ADD is not fully clear, although clinicians should be aware of patients with this condition, to provide an early diagnosis and improve patient´s prognosis.


Asunto(s)
Trastornos de la Articulación Temporomandibular , Articulación Temporomandibular , Humanos , Estudios Transversales , Esclerosis/patología , Articulación Temporomandibular/diagnóstico por imagen , Trastornos de la Articulación Temporomandibular/diagnóstico por imagen , Trastornos de la Articulación Temporomandibular/epidemiología , Imagen por Resonancia Magnética
3.
J Stomatol Oral Maxillofac Surg ; 123(6): e639-e642, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34856386

RESUMEN

INTRODUCTION: The aim of the present study was to evaluate the presence of the median perforating canal (MPC) and its morphometric measurements in Cone Beam CT (CBCT) scans of adult patients, correlating the findings with sex, age and skeletal facial patterns. MATERIAL AND METHODS: 717 CBCT scans were selected from a Brazilian population and the presence of the MPC was recorded. MPC diameter was measured in three points: lingual, medial and buccal. To determine the correlation between MPC presence and sex, age and ANB angle classifications the Chi-square test was performed. MPC diameters were related to sex, age and skeletal discrepancies using Mann-Whitney U and Kruskal-Wallis tests. The level of significance adopted was 5%. RESULTS: Of the 717 CBCT scans analyzed, the MPC was present in 181 patients (25.24%), 279 (38.91%) men and 438 (61.09%) women. The mean age was 37.91 (±14.46) years old, ranging from 18 to 88 years old. There were no differences in the presence of MPC between women and men (p = 0.85), between skeletal discrepancies (p = 0.09) and age groups (p = 0.94). Regarding the MPC diameter, statistical difference was found only for the medial diameter between sexes (p = 0.04), with the highest values in men. CONCLUSION: The MPC was detected in 25.24% of the studied population, with significant differences only for its medial diameter in men.


Asunto(s)
Maloclusión , Mandíbula , Adulto , Masculino , Humanos , Femenino , Adolescente , Adulto Joven , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Transversales , Tomografía Computarizada de Haz Cónico , Cara
4.
RGO (Porto Alegre) ; 70: e20220022, 2022. tab, graf
Artículo en Inglés | LILACS-Express | LILACS, BBO - odontología (Brasil) | ID: biblio-1394556

RESUMEN

ABSTRACT The aim of this study was to report a rare case of an asymptomatic calcification of unusual size and shape, inside the maxillary sinus identified on a cone beam computed tomography exam and to discuss the importance of knowledge of the anatomy of maxillary sinus and its changes carefully evaluating the entire volume of the images, regardless of the region of interest. An 83-year-old female patient underwent a cone beam computed tomography exam for other diagnostic purposes in the maxillofacial region. When analyzing the entire volume, an image of unusual limits, hyperdense and calcified was found in the right maxillary sinus, close to the anterior and medial wall, with a rounded and homogeneous shape, occupying approximately one third of the maxillary sinus. There was no lytic or erosive lesions on the maxillary sinus wall. The main diagnostic hypotheses raised were giant anthrolith, mucous retention phenomenon and osteoma. Due to the anatomical complexity of the maxillary sinus, diagnosis in this region becomes a challenge. Considering the limitations of 2D exams, the cone beam computed tomography exam can be used to evaluate these structures. Knowledge of differential hypotheses is extremely important for the case to be conducted correctly, but it does not replace biopsy and histopathological examination.


RESUMO O objetivo desse estudo foi relatar um caso raro de uma calcificação assintomática de tamanho e formato incomum, no interior do seio maxilar, diagnosticado em um exame de tomografia computadorizada de feixe cônico, além de discutir a importância do conhecimento da anatomia do seio maxilar e suas alterações, avaliando cuidadosamente todo o volume das imagens, independentemente da região de interesse. Paciente do sexo feminino, 83 anos de idade, realizou uma tomografia computadorizada de feixe cônico para outros fins de diagnóstico na região bucomaxilofacial. Ao analisar todo volume da tomografia encontrou-se uma imagem de limites incomuns, hiperdensa e calcificada, no seio maxilar direito, próximo a parede anterior e medial, com formato arredondado e homogêneo, ocupando aproximadamente um terço do seio maxilar, com as suas paredes intactas e sem nenhuma lesão lítica ou erosiva. As principais hipóteses diagnosticas levantadas foram antrólito gigante, fenômeno de retenção mucoso e osteoma. Devido a complexidade anatômica do seio maxilar, o diagnóstico nessa região se torna um desafio. Considerando as limitações dos exames 2D, a tomografia computadorizada de feixe cônico pode ser empregada para a avaliação dessas estruturas. O conhecimento do raciocínio diagnóstico e das hipóteses diferenciais são de extrema importância para o que o caso seja conduzido corretamente, porém não substituem a biópsia e o exame histopatológico.

5.
Int. j. odontostomatol. (Print) ; 15(1): 8-9, mar. 2021.
Artículo en Inglés | LILACS | ID: biblio-1385698

RESUMEN

A new type of RNA coronavirus (SARS-CoV-2) related to acute respiratory syndrome (SARS) and responsible for COVID-19 disease has spread around the world, resulting in an unprecedented pandemic. COVID-19 has become an international public health emergency and countless people and sectors have been affected. In this context, individual and collective protection measures were taken, mainly in health care. Dentistry, considered a high risk area, had to undergo changes in relation to biosecurity, including in radiological clinical practice. Thus, this letter aims to comment on these changes during visits to dental imaging centers.


Un nuevo tipo de coronavirus de ARN (SARS-CoV-2) relacionado con el síndrome respiratorio agudo (SARS) responsable de la enfermedad COVID-19 se ha extendido por todo el mundo y ha provocado una pandemia sin precedentes. COVID-19 se ha convertido en una emergencia de salud pública internacional y un sinnúmero de personas y sectores se han visto afectados. En este contexto, se tomaron medidas de protección individual y colectiva, principalmente en el ámbito de la salud. La atención dental, considerada de alto riesgo, tuvo que sufrir cambios en relación con la bioseguridad, incluida la práctica clínica radiológica. Así, esta carta tiene como objetivo comentar estos cambios durante los atendimientos a los centros de imagenología dental.


Asunto(s)
Humanos , Pandemias , COVID-19 , Radiología , Contención de Riesgos Biológicos , Odontología General/normas
6.
RFO UPF ; 25(3): 443-451, 20201231. ilus, tab
Artículo en Inglés | LILACS, BBO - odontología (Brasil) | ID: biblio-1357828

RESUMEN

Objetivo: este estudo avaliou a acurácia e confiabilidadedas medidas lineares em exames detomografia computadorizada de feixe cônico(TCFC), em dois softwares, utilizando diferentesvoxels e variando o posicionamento da mandíbula.Material e Métodos: 10 imagens de TCFC demandíbulas humanas com 25 pontos foram obtidas,usando diferentes protocolos de aquisição(0.250, 0.300, 0.400-mm voxels) e orientações damandíbula (centralizada, rotacionada 10° lateralmentepara direita e esquerda, inclinada 10° para cima e para baixo); 14 medidas foram realizadasnas reconstruções multiplanares nos softwares XoranCate OsiriX. Os achados foram comparadoscom as medidas físicas através de um paquímetrodigital. O teste ANOVA e o coeficiente de correlaçãoforam utilizados com p < 0,05. Resultados:não houve diferença estatisticamente significantequando as medidas foram comparadas em aquisiçõescom diferentes tamanhos de voxels emambos os softwares. A posição da mandíbula nãoinfluenciou nas medidas. Nenhuma diferença foiencontrada quando os valores foram comparadosentre os softwares e o paquímetro digital. Conclusão:as medidas lineares em ambos os softwaresforam confiáveis e acurados comparados a mensuraçãofísica em todos os protocolos. A acuráciae a confiabilidade das mensurações não influenciaramde acordo com as variações de posicionamentoda mandíbula.(AU)


Objective: this study evaluated the accuracy and reliability of linear measurements on cone beam CT (CBCT) scans in two software programs, using different voxels and varying mandible positioning. Material and methods: CBCT images of 10 human mandibles with 25 markers were obtained using different acquisition protocols (0.250, 0.300, 0.400-mm voxels) and mandible orientations (centered, rotated 10° laterally to right and left, tilted 10 up and down); fourteen measurements were carried out on the multiplanar reconstructions in XoranCat and OsiriX Lite software programs. The findings were compared to physical measurements using a digital caliper. ANOVA and correlation coefficient tests were used, at α = 0.05. Results: there was no statistically significant difference when the measurements were compared in acquisitions with different voxel sizes analysed in both software programs. Mandibular positioning changes did not influence the measurements. No differences were found when the values were compared between the software programs and the digital caliper. Conclusion: linear measurements in both programs were reliable and accurate compared with physical measurements when using all acquisition protocols. The accuracy and reliability of the measurements were not influenced by variations in the mandible positioning.(AU)


Asunto(s)
Humanos , Programas Informáticos/normas , Tomografía Computarizada de Haz Cónico/normas , Precisión de la Medición Dimensional , Mandíbula/diagnóstico por imagen , Valores de Referencia , Reproducibilidad de los Resultados , Análisis de Varianza , Tomografía Computarizada de Haz Cónico/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA