Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Interv Cardiol ; 2021: 6654515, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33880087

RESUMEN

BACKGROUND: While thinner struts are associated with improved clinical outcomes in bare-metal stents (BMS), reducing strut thickness may affect drug delivery from drug-eluting stents (DES) and there are limited data comparing otherwise similar thin and thick strut DES. We assessed 2-year outcomes of patients treated with a thin strut (84-88um) cobalt-chromium, biodegradable polymer, Biolimus A9-eluting stent (CoCr-BP-BES) and compared these to patients treated with a stainless steel, biodegradable polymer, Biolimus A9-eluting stent (SS-BP-BES). METHODS: In total, 1257 patients were studied: 400 patients from 12 centres receiving ≥1 CoCr-BP-BES in the prospective Biomatrix Alpha registry underwent prespecified comparison with 857 patients who received ≥1 Biomatrix Flex SS-BP-BES in the LEADERS study (historical control). The primary outcome was major adverse cardiac events (MACE)-cardiac death, myocardial infarction (MI), or clinically driven target vessel revascularization (cd-TVR). Propensity analysis was used to adjust for differences in baseline variables and a landmark analysis at day-3 to account for differences in periprocedural MI definitions. RESULTS: MACE at 2 years occurred in 6.65% CoCr-BP-BES versus 13.23% SS-BP-BES groups (unadjusted HR 0.48 [0.31-0.73]; P=0.0005). Following propensity analysis, 2-year adjusted MACE rates were 7.4% versus 13.3% (HR 0.53 [0.35-0.79]; P=0.004). Definite or probable stent thrombosis, adjudicated using identical criteria in both studies, occurred less frequently with CoCr-BP-BES (1.12% vs. 3.22%; adjusted HR 0.32 [0.11-0.9]; P=0.034). In day-3 landmark analysis, the difference in 2-year MACE was no longer significant but there was a lower patient-orientated composite endpoint (11.7% vs. 18.4%; HR 0.6 [0.43-0.83]; P=0.006) and a trend to lower target vessel failure (5.8% vs. 9.1%; HR 0.63 [0.4-1.00]; P=0.078). CONCLUSION: At 2-year follow-up, propensity-adjusted analysis showed the thin strut (84-88um) Biomatrix Alpha CoCr-BP-BES was associated with improved clinical outcomes compared with the thicker strut (114-120um) Biomatrix Flex SS-BP-BES.


Asunto(s)
Síndrome Coronario Agudo/terapia , Antiinflamatorios/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Sirolimus/análogos & derivados , Implantes Absorbibles , Anciano , Aleaciones de Cromo , Trombosis Coronaria/etiología , Stents Liberadores de Fármacos/efectos adversos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Sistema de Registros , Sirolimus/administración & dosificación , Acero Inoxidable , Resultado del Tratamiento
2.
Am Heart J ; 209: 97-105, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30703644

RESUMEN

BACKGROUND: The optimal duration of antiplatelet therapy in high-bleeding risk (HBR) patients with coronary artery disease treated with newer-generation drug-eluting bioresorbable polymer-coated stents remains unclear. DESIGN: MASTER DAPT (clinicaltrial.govNCT03023020) is an investigator-initiated, open-label, multicenter, randomized controlled trial comparing an abbreviated versus a standard duration of antiplatelet therapy after bioresorbable polymer-coated Ultimaster (TANSEI) sirolimus-eluting stent implantation in approximately 4,300 HBR patients recruited from ≥100 interventional cardiology centers globally. After a mandatory 30-day dual-antiplatelet therapy (DAPT) run-in phase, patients are randomized to (a) a single antiplatelet regimen until study completion or up to 5 months in patients with clinically indicated oral anticoagulation (experimental 1-month DAPT group) or (b) continue DAPT for at least 5 months in patients without or 2 in patients with concomitant indication to oral anticoagulation, followed by a single antiplatelet regimen (standard antiplatelet regimen). With a final sample size of 4,300 patients, this study is powered to assess the noninferiority of the abbreviated antiplatelet regimen with respect to the net adverse clinical and major adverse cardiac and cerebral events composite end points and if satisfied for the superiority of abbreviated as compared to standard antiplatelet therapy duration in terms of major or clinically relevant nonmajor bleeding. Study end points will be adjudicated by a blinded Clinical Events Committee. CONCLUSIONS: The MASTER DAPT study is the first randomized controlled trial aiming at ascertaining the optimal duration of antiplatelet therapy in HBR patients treated with sirolimus-eluting bioresorbable polymer-coated stent implantation.


Asunto(s)
Implantes Absorbibles/efectos adversos , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos/efectos adversos , Terapia Antiplaquetaria Doble/métodos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Hemorragia Posoperatoria/terapia , Anciano de 80 o más Años , Femenino , Humanos , Inmunosupresores/farmacología , Masculino , Intervención Coronaria Percutánea/métodos , Hemorragia Posoperatoria/etiología , Sirolimus/farmacología
3.
Cardiovasc Diabetol ; 16(1): 23, 2017 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-28183306

RESUMEN

OBJECTIVE: To report the long-term safety and efficacy data of a third generation drug eluting stent (DES) with biodegradable polymer in the complex patient population of diabetes mellitus after a follow-up period of 5 years. BACKGROUND: After percutaneous coronary intervention patients with diabetes mellitus are under higher risk of death, restenosis and stent thrombosis (ST) compared to non-diabetic patients. METHODS: In 126 centers worldwide 3067 patients were enrolled in the NOBORI 2 registry, 888 patients suffered from diabetes mellitus (DM), 213 of them (14%) being insulin dependent (IDDM). Five years follow-up has been completed in this study. RESULTS: At 5 years, 89.3% of the patients were available for follow-up. The reported target lesion failure (TLF) rates at 5 years were 12.39% in DM group and 7.34% in non-DM group; (p < 0.0001). In the DM group, the TLF rate in patients with IDDM was significantly higher than in the non-IDDM subgroup (17.84 vs. 10.67%; p < 0.01). The rate of ST at 5 years was not different among diabetic versus non-diabetic patients or IDDM versus NIDDM. Only 10 (<0.4%) very late stent thrombotic events beyond 12 months occurred. CONCLUSIONS: The Nobori DES performed well in patients with DM. As expected patients with DM, particularly those with IDDM, had worse outcomes. However, the very low rate of very late stent thrombosis in IDDM patients might have significant clinical value in the treatment of these patients. Clinical trial registration ISRCTN81649913; http://www.controlled-trials.com/isrctn/search.html?srch=81649913&sort=3&dir=desc&max=10.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/terapia , Diabetes Mellitus/tratamiento farmacológico , Stents Liberadores de Fármacos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Intervención Coronaria Percutánea/instrumentación , Polímeros/química , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidad , Femenino , Humanos , Hipoglucemiantes/efectos adversos , Insulina/efectos adversos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Heart ; 108(16): 1310-1318, 2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35012960

RESUMEN

OBJECTIVE: The primary objective was to assess the performance of a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer in an all comer population. The secondary objective was to detail differences in contemporary percutaneous coronary intervention (PCI) practice worldwide. METHODS: e-Ultimaster was an all-comer, prospective, global registry (NCT02188355) with independent event adjudication enrolling patients undergoing PCI with the study stent. The primary outcome measure was target lesion failure (TLF) at 1 year, defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularisation. Data were stratified according to 4 geographical regions. RESULTS: A total of 37 198 patients were enrolled (Europe 69.2%, Asia 17.8%, Africa/Middle East 6.6% and South America/Mexico 6.5%) and 1-year follow-up was available for 35 389 patients (95.1%). One-year TLF occurred in 3.2% of the patients, ranging from 2% (Africa/Middle East) to 4.1% (South America/Mexico). In patients with acute coronary syndrome, potent P2Y12 inhibitors were prescribed in 48% of patients at discharge, while at 1 year 72% were on any dual antiplatelet therapy. Lipid-lowering treatment was administered in 80.9% and 75.5% of patients at discharge and 1 year, respectively. Regional differences in the profile of the treated patients as well as in PCI practice were reported. CONCLUSIONS: In this investigation with worldwide representation, contemporary PCI using a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer was associated with low 1-year TLF across clinical presentations and continents. Suboptimal adherence to current recommendations around antiplatelet and lipid lowering treatments was detected.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Lípidos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Sistema de Registros , Sirolimus/uso terapéutico , Stents , Resultado del Tratamiento
5.
J Am Coll Cardiol ; 80(13): 1220-1237, 2022 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-36137672

RESUMEN

BACKGROUND: The optimal duration of antiplatelet therapy (APT) after coronary stenting in patients at high bleeding risk (HBR) presenting with an acute coronary syndrome remains unclear. OBJECTIVES: The objective of this study was to investigate the safety and efficacy of an abbreviated APT regimen after coronary stenting in an HBR population presenting with acute or recent myocardial infarction. METHODS: In the MASTER DAPT trial, 4,579 patients at HBR were randomized after 1 month of dual APT (DAPT) to abbreviated (DAPT stopped and 11 months single APT or 5 months in patients with oral anticoagulants) or nonabbreviated APT (DAPT for minimum 3 months) strategies. Randomization was stratified by acute or recent myocardial infarction at index procedure. Coprimary outcomes at 335 days after randomization were net adverse clinical outcomes events (NACE); major adverse cardiac and cerebral events (MACCE); and type 2, 3, or 5 Bleeding Academic Research Consortium bleeding. RESULTS: NACE and MACCE did not differ with abbreviated vs nonabbreviated APT regimens in patients with an acute or recent myocardial infarction (n = 1,780; HR: 0.83; 95% CI: 0.61-1.12 and HR: 0.86; 95% CI: 0.62-1.19, respectively) or without an acute or recent myocardial infarction (n = 2,799; HR: 1.03; 95% CI: 0.77-1.38 and HR: 1.13; 95% CI: 0.80-1.59; Pinteraction = 0.31 and 0.25, respectively). Bleeding Academic Research Consortium 2, 3, or 5 bleeding was significantly reduced in patients with or without an acute or recent myocardial infarction (HR: 0.65; 95% CI: 0.46-0.91 and HR: 0.71; 95% CI: 0.54-0.92; Pinteraction = 0.72) with abbreviated APT. CONCLUSIONS: A 1-month DAPT strategy in patients with HBR presenting with an acute or recent myocardial infarction results in similar NACE and MACCE rates and reduces bleedings compared with a nonabbreviated DAPT strategy. (Management of High Bleeding Risk Patients Post Bioresorbable Polymer Coated Stent Implantation With an Abbreviated Versus Prolonged DAPT Regimen [MASTER DAPT]; NCT03023020).


Asunto(s)
Infarto del Miocardio , Intervención Coronaria Percutánea , Anticoagulantes/uso terapéutico , Dimaprit/análogos & derivados , Quimioterapia Combinada , Hemorragia/inducido químicamente , Hemorragia/epidemiología , Humanos , Infarto del Miocardio/tratamiento farmacológico , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/efectos adversos , Polímeros , Stents , Resultado del Tratamiento
6.
Coron Artery Dis ; 32(5): 391-396, 2021 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-33060529

RESUMEN

OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.


Asunto(s)
Aleaciones de Cromo/farmacología , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Complicaciones Posoperatorias , Sirolimus/análogos & derivados , Sirolimus/farmacología , Anciano , Materiales Biocompatibles/farmacología , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Stents Liberadores de Fármacos/clasificación , Análisis de Falla de Equipo , Femenino , Humanos , Inmunosupresores/farmacología , Masculino , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Diseño de Prótesis , Sistema de Registros/estadística & datos numéricos , Análisis de Supervivencia
7.
EuroIntervention ; 11(1): 75-84, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25868876

RESUMEN

AIMS: This study aimed to evaluate the safety and performance of the TriGuard™ Embolic Deflection Device (EDD), a nitinol mesh filter positioned in the aortic arch across all three major cerebral artery take-offs to deflect emboli away from the cerebral circulation, in patients undergoing transcatheter aortic valve replacement (TAVR). METHODS AND RESULTS: The prospective, multicentre DEFLECT I study (NCT01448421) enrolled 37 consecutive subjects undergoing TAVR with the TriGuard EDD. Subjects underwent clinical and cognitive follow-up to 30 days; cerebral diffusion-weighted magnetic resonance imaging (DW-MRI) was performed pre-procedure and at 4±2 days post procedure. The device performed as intended with successful cerebral coverage in 80% (28/35) of cases. The primary safety endpoint (in-hospital EDD device- or EDD procedure-related cardiovascular mortality, major stroke disability, life-threatening bleeding, distal embolisation, major vascular complications, or need for acute cardiac surgery) occurred in 8.1% of subjects (VARC-defined two life-threatening bleeds and one vascular complication). The presence of new cerebral ischaemic lesions on post-procedure DW-MRI (n=28) was similar to historical controls (82% vs. 76%, p=NS). However, an exploratory analysis found that per-patient total lesion volume was 34% lower than reported historical data (0.2 vs. 0.3 cm3), and 89% lower in patients with complete (n=17) versus incomplete (n=10) cerebral vessel coverage (0.05 vs. 0.45 cm3, p=0.016). CONCLUSIONS: Use of the first-generation TriGuard EDD during TAVR is safe, and device performance was successful in 80% of cases during the highest embolic-risk portions of the TAVR procedure. The potential of the TriGuard EDD to reduce total cerebral ischaemic burden merits further randomised investigation.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/instrumentación , Dispositivos de Protección Embólica , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Embolia Intracraneal/prevención & control , Anciano , Anciano de 80 o más Años , Aleaciones , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Isquemia Encefálica/etiología , Isquemia Encefálica/prevención & control , Brasil , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Cognición , Trastornos del Conocimiento/etiología , Trastornos del Conocimiento/prevención & control , Imagen de Difusión por Resonancia Magnética , Europa (Continente) , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Embolia Intracraneal/diagnóstico , Embolia Intracraneal/etiología , Embolia Intracraneal/mortalidad , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Índice de Severidad de la Enfermedad , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Transcraneal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA