Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Electrophoresis ; 42(6): 693-699, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33247595

RESUMEN

Polyethylene glycol-modified canine uricase (PEG-UHC) was prepared by modifying the ε-amino group of lysine residues on the canine uricase (UHC) protein to near-saturation with 5 kDa monomethoxyl-polyethylene glycol succinimide (mPEG-SPA-5k). In order to accurately determine the PEGylation uniformity of PEG-UHC, CZE, 3-8% gradient gel SDS-PAGE, and imaging CIEF (iCIEF) analyses were compared. CZE could not effectively separate PEG-UHC proteins with different degrees of modification, 3-8% gradient gel SDS-PAGE could separate PEG-UHC into seven gel bands; however, most of the gel bands were smeared or blurred, and the separation of PEG-UHC samples by iCIEF was significantly better than that by 3-8% gradient gel SDS-PAGE. Under denatured conditions, iCIEF separated 12 pI peaks, and could also accurately quantify the relative monomer PEG-UHC content. More than 85% of the total monomeric PEG-UHC was conjugated with 7-12 PEG molecules; of this 85%, approximately 40% was conjugated with 9-10 PEG molecules. These results demonstrated that iCIEF exhibits good potential for determining the PEGylation homogeneity of PEGylated protein drugs.


Asunto(s)
Urato Oxidasa/metabolismo , Animales , Perros , Electroforesis en Gel de Poliacrilamida , Lisina , Polietilenglicoles , Proteínas
2.
Biomater Sci ; 12(10): 2730-2742, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38639196

RESUMEN

Polypropylene (PP) mesh is widely used in hernioplasty, but it is prone to contamination by pathogenic bacteria. Here, we present an infection microenvironment-responsive metal-phenolic network (MPN) coating, which is made up of Cu2+ and tannic acid (TA) (referred to as CT coating), and is fabricated on PP meshes by layer-by-layer (LbL) assembly. The CT coating provided a robust protection for the PP mesh from pathogenic bacterial infection in a pH-responsive manner due to the pH-responsive disassembly kinetics of MPN complexes. Moreover, the PP meshes with ten CT coating cycles (PP-CT(10)) exhibited excellent stability in a physiological environment, with the killing ratio against "superbug" methicillin-resistant Staphylococcus aureus (MRSA) at pH 5.5 exceeding 99% even after 28 days of PBS (pH 7.4) immersion. In addition, the PP-CT(10) exhibited excellent in vivo anti-infective ability in a rodent subcutaneous implant MRSA infection model, and the results of histological and immunohistochemical analyses demonstrated that the reduced bacterial number alleviated the inflammatory response at implant sites. This study revealed that MPN coating is a promising strategy, which could provide a self-defensive ability for various implants to combat post-surgical infections in a pH-responsive manner.


Asunto(s)
Antibacterianos , Staphylococcus aureus Resistente a Meticilina , Polipropilenos , Mallas Quirúrgicas , Taninos , Concentración de Iones de Hidrógeno , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Animales , Antibacterianos/farmacología , Antibacterianos/química , Antibacterianos/administración & dosificación , Polipropilenos/química , Taninos/química , Taninos/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Infecciones Estafilocócicas/tratamiento farmacológico , Herniorrafia , Cobre/química , Cobre/farmacología , Ratones
3.
ACS Nano ; 18(24): 16011-16026, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38841994

RESUMEN

Infection and aseptic loosening caused by bacteria and poor osseointegration remain serious challenges for orthopedic implants. The advanced surface modification of implants is an effective strategy for addressing these challenges. This study presents a "pneumatic nanocannon" coating for titanium orthopedic implants to achieve on-demand release of antibacterial and sustained release of osteogenic agents. SrTiO3 nanotubes (SrNT) were constructed on the surface of Ti implants as "cannon barrel," the "cannonball" (antibiotic) and "propellant" (NH4HCO3) were codeposited into SrNT with assistance of mussel-inspired copolymerization of dopamine and subsequently sealed by a layer of polydopamine. The encapsulated NH4HCO3 within the nanotubes could be thermally decomposed into gases under near-infrared irradiation, propelling the on-demand delivery of antibiotics. This coating demonstrated significant efficacy in eliminating typical pathogenic bacteria both in planktonic and biofilm forms. Additionally, this coating exhibited a continuous release of strontium ions, which significantly enhanced the osteogenic differentiation of preosteoblasts. In an implant-associated infection rat model, this coating demonstrated substantial antibacterial efficiency (>99%) and significant promotion of osseointegration, along with alleviated postoperative inflammation. This pneumatic nanocannon coating presents a promising approach to achieving on-demand infection inhibition and sustained osseointegration enhancement for titanium orthopedic implants.


Asunto(s)
Antibacterianos , Nanotubos , Óxidos , Estroncio , Titanio , Estroncio/química , Estroncio/farmacología , Animales , Titanio/química , Titanio/farmacología , Antibacterianos/farmacología , Antibacterianos/química , Ratas , Óxidos/química , Óxidos/farmacología , Nanotubos/química , Prótesis e Implantes , Oseointegración/efectos de los fármacos , Ratones , Ratas Sprague-Dawley , Indoles/química , Indoles/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Osteogénesis/efectos de los fármacos , Propiedades de Superficie , Polímeros/química , Polímeros/farmacología , Biopelículas/efectos de los fármacos , Pruebas de Sensibilidad Microbiana
4.
Adv Healthc Mater ; 13(18): e2304510, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38532711

RESUMEN

Aseptic loosening and bacterial infection pose significant challenges in the clinical application of titanium (Ti) orthopedic implants, which are primarily caused by insufficient osseointegration and bacterial contamination. To address these issues, a responsive coating on Ti surface is constructed, which achieves enhanced osseointegration and infection elimination by on-demand release of therapeutic gas hydrogen sulfide (H2S) and antibiotic. TiO2 nanotubes (TNT) are anodized on the Ti surface to enhance its bioactivity and serve as reservoirs for the antibiotic. An infection microenvironment-responsive macromolecular H2S donor layer is coated on top of TNT to inhibit premature leakage of antibiotic. This layer exhibits a sustained release of low-dosage H2S, which is capable of promoting the osteogenic differentiation and migration of cells. Moreover, the compactness of the macromolecular H2S donor layer could be broken by bacterial invasion, leading to rapid antibiotic release thus preventing infection. In vitro antibacterial experiments validates significant antibacterial activity of the coating against both Gram-negative (Escherichia coli) and Gram-positive bacteria (Staphylococcus aureus). Crucially, this coating effectively suppresses implant-associated infection with 98.7% antibacterial efficiency in a rat femoral bone defect model, mitigates inflammation at the defect site and promotes osseointegration of the Ti orthopedic implant.


Asunto(s)
Antibacterianos , Materiales Biocompatibles Revestidos , Escherichia coli , Sulfuro de Hidrógeno , Staphylococcus aureus , Titanio , Titanio/química , Titanio/farmacología , Animales , Antibacterianos/farmacología , Antibacterianos/química , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Staphylococcus aureus/efectos de los fármacos , Ratas , Escherichia coli/efectos de los fármacos , Sulfuro de Hidrógeno/química , Sulfuro de Hidrógeno/farmacología , Oseointegración/efectos de los fármacos , Nanotubos/química , Ratas Sprague-Dawley , Propiedades de Superficie , Prótesis e Implantes , Osteogénesis/efectos de los fármacos , Humanos
5.
ACS Appl Mater Interfaces ; 13(51): 61669-61680, 2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-34915703

RESUMEN

The contamination of pathogenic micro-organisms and heavy metals in drinking water sources poses a serious threat to human health, which raises the demand for efficient water treatments. Herein, multi-functional capacitive deionization (CDI) electrodes were developed for the simultaneous decontamination of bacteria and heavy metal contaminants. Polyhexamethylene guanidine (PHMG), an antibacterial polymer, was deposited on the surface of the activated carbon (AC) electrode with the assistance of mussel-inspired polydopamine (PDA) chemistry. The main characterization results proved successful co-deposition of PDA and PHMG on the AC electrode, forming a hydrophilic coating layer in one step. Electrochemical analyses indicated that the AC-PDA/PHMG electrodes presented satisfactory capacitive behaviors, with outstanding salt adsorption capacity and cycling stability. The modified electrodes also exhibit excellent disinfection performance and heavy metal adsorption performance. The bacterial elimination rate of co-deposited electrodes grew along with the increase in the PHMG content. Particularly, AC-PDA/PHMG2 electrodes successfully removed and deactivated 99.11% Escherichia coli and 98.67% Pseudomonas aeruginosa (104 CFU mL-1) in water within 60 min. Furthermore, three flow cells made by AC-PDA/PHMG2 electrodes connected in series achieved efficient removal of salt, heavy metals such as lead and cadmium, and bacteria simultaneously, which indicated that the adsorption performance is significantly improved compared with pristine AC electrodes. These results denote the enormous potential of this one-step prepared multi-functional electrodes for facile and effective water purification using CDI technology.


Asunto(s)
Materiales Biocompatibles/química , Carbono/química , Guanidinas/química , Indoles/química , Polímeros/química , Purificación del Agua , Cadmio/aislamiento & purificación , Técnicas Electroquímicas , Electrodos , Escherichia coli/aislamiento & purificación , Plomo/aislamiento & purificación , Ensayo de Materiales , Estructura Molecular , Pseudomonas aeruginosa/aislamiento & purificación
6.
Eur J Drug Metab Pharmacokinet ; 45(4): 445-451, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32162270

RESUMEN

BACKGROUND AND OBJECTIVE: Polyethylene glycol-modified canine uricase (PEG-UHC) prepared with a lower-molecular-weight (5 kDa) PEG is used to treat gout. This study investigated the comparative pharmacokinetics of single and multiple doses of PEG-UHC administered intravenously and a single dose of uricase (UHC) administered intravenously in cynomolgus monkeys. METHODS: A noncompartmental model was used to fit the plasma drug concentration-time curve and calculate the pharmacokinetic parameters of PEG-UHC, which were compared with those obtained for UHC at the equivalent dose (2 mg/kg). To study the pharmacokinetics after multiple dose administration, cynomolgus monkeys were administered five intravenous injections of PEG-UHC (0.5 mg/kg), with one injection performed every 15 days. RESULTS: The area under the curve (AUC) and the maximum plasma concentration (Cmax) of PEG-UHC were positively correlated with dose, whereas plasma half-life (t1/2) and clearance (CL) did not change significantly with increasing dose, suggesting that these pharmacokinetic characteristics are linear. Intravenous PEG-UHC exhibited an average t1/2 that was 125.79 times longer and an AUC0-t that was 64.45 times larger than the corresponding values for UHC at the same dose (2 mg/kg), while the CL of PEG-UHC was 1/72.73 times the CL of intravenous UHC. The plasma drug concentration reached a steady state after five injections, and the t1/2 values following the first and last drug administration did not differ significantly. CONCLUSION: Our data show that PEG-UHC is markedly superior to UHC in terms of duration of action, and that the pharmacokinetics of PEG-UHC in cynomolgus monkeys are linear. Sequential administration of PEG-UHC did not accelerate drug clearance. Our findings provide the basis for future clinical studies of PEG-UHC.


Asunto(s)
Supresores de la Gota/administración & dosificación , Supresores de la Gota/farmacocinética , Polietilenglicoles/administración & dosificación , Polietilenglicoles/farmacocinética , Urato Oxidasa/administración & dosificación , Urato Oxidasa/farmacocinética , Animales , Esquema de Medicación , Composición de Medicamentos , Femenino , Inyecciones Intravenosas , Macaca fascicularis , Masculino , Modelos Biológicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA