Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Odontology ; 112(2): 570-587, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37957521

RESUMEN

This study aims to evaluate the number of roots and root canal morphology types of maxillary premolars in relation to a patient's gender and age in an Iraqi population using two classification systems. Cone beam computed tomography (CBCT) scans of 1116 maxillary premolars from 385 patients were evaluated for the number of roots and root canal morphology types according to Vertucci's classification and Ahmed et al. classification systems. Differences in the number of roots and root canal morphology types with regard to tooth type, patients' gender and age groups were evaluated and the degree of bilateral symmetry was determined. Chi-squared test was used for statistical analysis. About 51.1% of the 1st premolars were double rooted. The majority (87.9%) of the 2nd premolars were single rooted. The three-rooted form presented in only 1.2% and 0.7% of the 1st and 2nd premolars, respectively. Vertucci Type IV (Ahmed et al. code 2MaxP B1P1) and Vertucci Type I (Ahmed et al. code 1MaxP1) were the most common canal morphology types in the 1st and 2nd premolars, respectively. Females showed a lower number of roots and a higher prevalence of Vertucci Type I configuration (P < 0.05). Younger age groups showed a higher prevalence of Vertucci Type I configuration (P < 0.05). Bilateral symmetry was seen in more than half of the maxillary premolars. There is a considerable variation in the number of roots and root canal configurations of maxillary premolars in the studied Iraqi population, with a significant difference by gender and age groups. Ahmed et al. classification provided more accurate presentation of the root and canal anatomy in maxillary premolars compared to Vertucci's classification.


Asunto(s)
Cavidad Pulpar , Raíz del Diente , Femenino , Humanos , Diente Premolar/diagnóstico por imagen , Diente Premolar/anatomía & histología , Cavidad Pulpar/diagnóstico por imagen , Irak , Raíz del Diente/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos
2.
J Prosthet Dent ; 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38627176

RESUMEN

STATEMENT OF PROBLEM: Three-dimensional (3D) printing of cobalt chromium (Co-Cr) removable partial dentures (RPDs)by selective laser melting (SLM) has been claimed to be less challenging than by conventional casting and provides significant improvements. However, the adaptation and fit of the SLM framework and the optimum build orientation are still unclear. PURPOSE: The purpose of this in vitro and clinical study was to evaluate the effect of different build orientations on the adaptation of removable partial denture frameworks fabricated by SLM technology in vitro and to compare the adaptation of the SLM and conventional RPD frameworks clinically. MATERIAL AND METHODS: A master model simulating a maxillary arch of Kennedy class III modification 1 was scanned and duplicated to create a virtual 3D cast and reference cast. Four groups (n=40) of Co-Cr RPD frameworks were fabricated. For the SLM groups, the Co-Cr framework was virtually designed and exported for SLM printing. The SLM printing was done in 3 different build orientations: 0-degree (n=10), 45-degree (n=10), and 90-degree (n=10) groups. Other Co-Cr frameworks were conventionally cast (n=10). All Co-Cr frameworks were scanned and virtually superimposed with the master model using a surface-matching software program. The gap under 9 selected points in the palatal major connectors was analyzed and calculated. A smaller gap indicates more surface adaptation and close contact between the palatal major connector and the master model. The data were analyzed using the Kruskal-Wallis and Dunnett T3 tests (α=.05). Three patients with a partially dentate maxillary arch were enrolled in the clinical part based on inclusion criteria. Two RPD frameworks were provided for each patient (conventional casting and SLM printing). The adaptation of each framework was assessed by measuring the gap between the palatal major connector of the framework and the palate with light-body silicone. The differences in adaptation between the conventional and SLM frameworks were compared by using independent t tests (α=.05). RESULTS: The in vitro study identified significant differences in the adaptation of the palatal major connector among the 4 groups (P<.001), except for conventional and 0-degree SLM printing (P=.999). The conventional and 0-degree SLM frameworks exhibited the best adaptation, with the lowest gap underneath the palatal major connector of the RPD framework (0.01 ±0.02 mm and 0.01 ±0.01 mm, respectively). In the clinical part of the study, no significant difference was found between the adaptation of SLM and the conventional framework (P=.430) CONCLUSIONS: The adaptation of SLM printing can be maximized with less gap under the palatal major connector of the RPD framework when using the 0-degree build orientation. Co-Cr frameworks produced with SLM printing technology were comparable with conventionally produced frameworks; hence, SLM printed frameworks can be an alternative for clinical applications when optimum SLM parameters are applied.

3.
BMC Oral Health ; 24(1): 252, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38373931

RESUMEN

BACKGROUND: Artificial intelligence has been proven to improve the identification of various maxillofacial lesions. The aim of the current study is two-fold: to assess the performance of four deep learning models (DLM) in external root resorption (ERR) identification and to assess the effect of combining feature selection technique (FST) with DLM on their ability in ERR identification. METHODS: External root resorption was simulated on 88 extracted premolar teeth using tungsten bur in different depths (0.5 mm, 1 mm, and 2 mm). All teeth were scanned using a Cone beam CT (Carestream Dental, Atlanta, GA). Afterward, a training (70%), validation (10%), and test (20%) dataset were established. The performance of four DLMs including Random Forest (RF) + Visual Geometry Group 16 (VGG), RF + EfficienNetB4 (EFNET), Support Vector Machine (SVM) + VGG, and SVM + EFNET) and four hybrid models (DLM + FST: (i) FS + RF + VGG, (ii) FS + RF + EFNET, (iii) FS + SVM + VGG and (iv) FS + SVM + EFNET) was compared. Five performance parameters were assessed: classification accuracy, F1-score, precision, specificity, and error rate. FST algorithms (Boruta and Recursive Feature Selection) were combined with the DLMs to assess their performance. RESULTS: RF + VGG exhibited the highest performance in identifying ERR, followed by the other tested models. Similarly, FST combined with RF + VGG outperformed other models with classification accuracy, F1-score, precision, and specificity of 81.9%, weighted accuracy of 83%, and area under the curve (AUC) of 96%. Kruskal Wallis test revealed a significant difference (p = 0.008) in the prediction accuracy among the eight DLMs. CONCLUSION: In general, all DLMs have similar performance on ERR identification. However, the performance can be improved by combining FST with DLMs.


Asunto(s)
Aprendizaje Profundo , Resorción Radicular , Tomografía Computarizada de Haz Cónico Espiral , Humanos , Resorción Radicular/diagnóstico por imagen , Inteligencia Artificial , Tomografía Computarizada de Haz Cónico
4.
Ann Hum Biol ; 49(2): 109-115, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35535801

RESUMEN

AIM: This study compared the effectiveness of the three-dimensional (3D) cone beam computed tomography (CBCT) method of age estimation developed by Asif et al. with two-dimensional Cameriere's method. SUBJECTS AND METHODS: CBCT images belonging to 129 Malaysian Chinese and Malay ethnic groups aged 7-14 years were investigated and analysed. RESULTS: The results indicated a strong correlation between chronological age and the predictor variables for both Cameriere's (r = 0.984) and Asif's (r = 0.988) methods of age estimation. Fisher Z test analysis indicated no statistically significant difference in the correlation values between the two methods. Mean absolute error (MAE) value of 0.613 was observed for Cameriere's and 0.290 was observed for Asif's method. CONCLUSIONS: The results indicated that the methods of age estimation from both Asif et al. and Cameriere et al. are applicable on Malaysian children. However, Asif et al.'s 3D CBCT method of age estimation resulted in greater accuracy and reliability in estimating chronological age.


Asunto(s)
Determinación de la Edad por los Dientes , Determinación de la Edad por los Dientes/métodos , Pueblo Asiatico , Niño , Etnicidad , Humanos , Imagenología Tridimensional , Radiografía Panorámica , Reproducibilidad de los Resultados
5.
J Prosthet Dent ; 128(3): 530.e1-530.e7, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35933173

RESUMEN

STATEMENT OF PROBLEM: Additive manufacturing by selective laser melting (SLM) has been claimed to be less challenging than conventional casting of cobalt-chromium (Co-Cr) removable partial dentures (RPDs), providing significant improvements. However, how the physicomechanical properties of Co-Cr RPDs fabricated by SLM compare with those fabricated by conventional casting is unclear. PURPOSE: The purpose of this in vitro study was to evaluate the physicomechanical properties of Co-Cr RPD palatal major connectors fabricated by SLM compared with those fabricated by conventional casting. MATERIAL AND METHODS: A master die simulating a maxillary arch of Kennedy class III modification 1 was scanned to create a virtual 3-dimensional (3D) cast. Two groups of 5 Co-Cr RPD major connectors were fabricated. In the 3D printing group, the Co-Cr major connector was virtually designed and exported for direct SLM 3D printing. For the conventional group, Co-Cr major connectors were constructed conventionally. The Co-Cr major connectors were virtually superimposed with the master die for surface adaptation analysis. Additional comparative analyses of surface roughness, relative density, microhardness, and microstructure of the 2 groups were performed. Data were analyzed by using independent t tests (α=.05). RESULTS: The overall volumetric and linear discrepancies were significantly higher (P<.05) in the 3D printing group. Significant differences in the surface roughness (P<.05) and microhardness (P<.05) were observed, with the 3D printing group having higher surface roughness and microhardness than the conventional group. Unlike conventional connectors, the microstructure of 3D-printed connectors showed fine homogeneous granules. CONCLUSIONS: Compared with the conventional casting technique, SLM 3D printing enabled the fabrication of Co-Cr RPD major connectors with higher microhardness and fine homogenous microstructure. However, the surface adaptation and surface roughness of SLM 3D printing Co-Cr connectors were worse than those produced conventionally. Both techniques showed similar relative densities.


Asunto(s)
Dentadura Parcial Removible , Cromo , Aleaciones de Cromo/química , Cobalto , Rayos Láser , Fenómenos Químicos
6.
BMC Oral Health ; 21(1): 249, 2021 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-33964918

RESUMEN

BACKGROUND: The aim of this study was to compare the trabecular bone microstructures of anterior and posterior edentulous regions of human mandible using cone-beam computed tomography (CBCT) and micro computed tomography (µCT). METHODS: Twenty volumes of interests consisting of six anterior and fourteen posterior edentulous regions were obtained from human mandibular cadavers. A CBCT system with a resolution of 80 µm (3D Accuitomo 170, J. Morita, Kyoto, Japan) and a µCT system with a resolution of 35 µm (SkyScan 1173, Kontich, Belgium) were used to scan the mandibles. Three structural parameters namely, trabecular number (Tb.N), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp) were analysed using CTAn software (v 1.11, SkyScan, Kontich, Belgium). For each system, the measurements obtained from anterior and posterior regions were tested using independent sample t-test. Subsequently, all measurements between systems were tested using paired t-test. RESULTS: In CBCT, all parameters of the anterior and posterior mandible showed no significant differences (p > 0.05). However, µCT showed a significant different of Tb.Th (p = 0.023) between anterior and posterior region. Regardless of regions, the measurements obtained using both imaging systems were significantly different (p ≤ 0.021) for Tb.Th and Tb.N. CONCLUSIONS: The current study demonstrated that only the variation of Tb.Th between anterior and posterior edentulous region of mandible can be detected using µCT. In addition, CBCT is less feasible than µCT in assessing trabecular bone microstructures at both regions.


Asunto(s)
Hueso Esponjoso , Mandíbula , Bélgica , Hueso Esponjoso/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Humanos , Japón , Mandíbula/diagnóstico por imagen , Microtomografía por Rayos X
7.
J Prosthet Dent ; 124(6): 674-681, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31952858

RESUMEN

STATEMENT OF PROBLEM: Wearers of mandibular complete dentures (CDs) often complain of retention and stability problems resulting in poor masticatory function. Evidence suggests that a mandibular overdenture (MOD) stabilized by 2 implants represents the treatment of choice to improve stability and masticatory function. Measurements are needed of the improvement in masticatory function after providing mandibular implant-stabilized overdentures. PURPOSE: The purpose of this prospective clinical study was to evaluate the changes in masticatory function from baseline (T0) to 3 months (T1) and 3 years (T2) in participants with MODs and to assess the effect of baseline mandibular bone height and volume on masticatory function after 3 years. MATERIAL AND METHODS: Participants were assessed for masticatory function by using masticatory performance involving paraffin wax cubes as an objective measure and by using masticatory ability involving a questionnaire as a subjective measure. Edentulous individuals presenting for replacement dentures were provided with conventional mucosa-supported prostheses and evaluated for masticatory function after a 3-month settling-in period (baseline measure). Before implant placement, baseline measures of bone height and volume were recorded from cone beam computed tomography (CBCT) images. The prostheses were then converted to implant-stabilized mandibular overdentures while any maxillary prostheses remained supported by the mucosa. Masticatory function was reassessed at 3 months and 3 years after insertion of the mandibular overdentures, and the mean changes from baseline were analyzed with the Wilcoxon signed-rank test. The effect of variables on masticatory function was determined by using multivariate linear regression analyses. RESULTS: A total of 23 participants were included in the study, with only 1 participant not completing the 3-year assessment. Significant improvement was observed in the masticatory performance (mixing ability index) (P<.01) and masticatory ability score (P<.001) from baseline to 3 months and baseline to 3 years. Bone height and volume had no significant effect on the improvement of masticatory function after conversion to an implant-stabilized mandibular overdenture. CONCLUSIONS: Masticatory function significantly improved after 3 months and was maintained over 3 years in participants with implant-stabilized mandibular overdentures. However, baseline bone height and volume had no significant effect on these changes in masticatory function after 3 years.


Asunto(s)
Implantes Dentales , Prótesis de Recubrimiento , Prótesis Dental de Soporte Implantado , Dentadura Completa Inferior , Humanos , Mandíbula/diagnóstico por imagen , Masticación , Satisfacción del Paciente , Estudios Prospectivos
8.
Am J Orthod Dentofacial Orthop ; 158(4): 579-586.e1, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32826123

RESUMEN

INTRODUCTION: The study aimed to investigate the effects of micro-osteoperforations (MOPs) on the mandibular bone volume/tissue volume (BV/TV) ratio changes and the rate of orthodontic tooth movement using cone-beam computed tomography images. Another objective was to evaluate the effects of MOP frequency intervals (4 weeks, 8 weeks, and 12 weeks) on the BV/TV ratio and rate of tooth movement. METHODS: In 24 participants, 140-200 g of force was applied for mandibular canine retraction. Three MOPs were made according to the scheduled intervals of the 3 different groups: group 1 (MOP 4 weeks), group 2 (MOP 8 weeks), and group 3 (MOP 12 weeks) directly at the mandibular buccal cortical bone of extracted first premolars sites. Cone-beam computed tomography scans were obtained at the 12th week after MOP application. Computed tomography Analyzer software (version 1.11.0.0; Skyscan, Kontich, Belgium) was used to compute the trabecular alveolar BV/TV ratio. RESULTS: A significant difference was observed in the rate of canine movement between control and MOP. Paired t test analysis showed a significant difference (P = 0.001) in the mean BV/TV ratio between control and MOP sides in all the frequency intervals groups. However, the difference was significant only in group 1 (P = 0.014). A strong negative correlation (r = -0.86) was observed between the rate of canine tooth movement and the BV/TV ratio at the MOP side for group 1 and all frequency intervals together (r = -0.42). CONCLUSIONS: The rate of orthodontic tooth movement can be accelerated by the MOP technique with frequently repeated MOPs throughout the treatment.


Asunto(s)
Diente Canino/diagnóstico por imagen , Técnicas de Movimiento Dental , Diente Premolar , Tomografía Computarizada de Haz Cónico , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía
9.
BMC Oral Health ; 20(1): 48, 2020 02 10.
Artículo en Inglés | MEDLINE | ID: mdl-32041589

RESUMEN

BACKGROUND: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment. METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 µm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 µm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15). RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%. CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.


Asunto(s)
Hueso Esponjoso/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Animales , Masculino , Maxilar , Ovinos , Programas Informáticos
10.
J Prosthodont ; 28(4): 373-378, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30875139

RESUMEN

PURPOSE: Blood flow disturbance from functional pressure may lead to ischemia and accumulation of metabolites leading to residual ridge resorption (RRR) underneath complete dentures. The purposes of this study were to determine the effect of mandibular complete denture (CD) and implant-retained overdenture (IRO) on blood flow disturbance in the opposing denture bearing-mucosa of maxillary CD and to compare the blood flow disturbance to RRR of the anterior maxilla. MATERIALS AND METHODS: The test group included 9 participants rehabilitated by maxillary CD opposing mandibular IRO, while the control group consisted of 4 participants with CDs. Blood flow was measured by laser Doppler flowmetry (LDF) after denture removal for 0, 30, 60, and 90 minutes. RRR was quantified as reduction in bone volume a year post-treatment. The measurement of blood flow was then compared to the quantification of RRR. RESULTS: The mean blood flow measure for the IRO group was significantly lower than CD after immediate denture removal and 30 minutes later. After 60 minutes, the mean difference was not significant between groups, and at 90 minutes, the mean blood flow of both groups equalized to reach a steady state of 377 BPU. The mandibular IRO had reduced the initial blood flow measure in the opposing anterior maxilla mucosa to almost a quarter (103 BPU) of the steady state value (377 BPU) compared to the CD, which reduced it to only about one half (183 BPU), suggesting greater blood flow disturbance in the IRO group. This result is in tandem with the greater reduction of bone volume observed in the IRO group, which was 7.3 ± 1.3% after a year, almost three times higher than CD group at 2.6 ± 1.7%. CONCLUSION: IRO may cause significantly higher blood flow disturbance than CD and may have contributed to greater RRR in the anterior maxilla.


Asunto(s)
Pérdida de Hueso Alveolar , Prótesis de Recubrimiento , Prótesis Dental de Soporte Implantado , Retención de Dentadura , Dentadura Completa Inferior , Humanos , Mandíbula , Maxilar , Membrana Mucosa
11.
J Prosthodont ; 28(2): 131-137, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30427557

RESUMEN

PURPOSE: To compare the residual ridge resorption (RRR) of the anterior maxillary bone beneath complete dentures when opposed by mandibular complete dentures (CD) and implant-retained overdentures (IRO). MATERIALS AND METHODS: 18 patients were rehabilitated with maxillary CD opposing mandibular IRO, and 4 patients were prescribed with conventional CD. Cone beam computed tomography (CBCT) scans of the maxilla were acquired before and 1 year post-treatment and converted into 3D models using Mimics research software. RRR was quantified by measuring the changes in bone volume following superimpositioning and sectioning of these models at the anterior maxillary region. Subsequently, the sectioned 3D models of the anterior maxilla were exported to 3-Matic software to reveal the predominant region and depth of RRR. RESULTS: The mean reduction in bone volume of the anterior maxilla in the CD group was 2.60% (SD = 1.71%, range = -4.89 % to -0.92%, median = -2.30%), while the mean reduction in the IRO group was almost three times higher at 7.25% (SD = 3.16%, range = -13.25 to -1.50, median = -7.15%). The predominant areas of RRR were on the buccal and occlusal ridge of the anterior maxilla. CONCLUSION: Within the limits of this study, it may be concluded that an IRO caused significantly higher RRR of the anterior maxilla than a CD.


Asunto(s)
Pérdida de Hueso Alveolar/etiología , Prótesis Dental de Soporte Implantado/efectos adversos , Prótesis de Recubrimiento/efectos adversos , Enfermedades Maxilares/etiología , Anciano , Pérdida de Hueso Alveolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico , Femenino , Humanos , Imagenología Tridimensional , Masculino , Mandíbula , Enfermedades Maxilares/diagnóstico por imagen , Persona de Mediana Edad , Factores de Riesgo
12.
Am J Orthod Dentofacial Orthop ; 154(2): 260-269, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30075928

RESUMEN

INTRODUCTION: In this study, we evaluated the effect of bone-borne accelerated expansion protocols on sutural separation and sutural bone modeling using a microcomputed tomography system. We also determined the optimum instant sutural expansion possible without disruption of bone modeling. METHODS: Sixteen New Zealand white rabbits, 20 to 24 weeks old, were randomly divided into 4 experimental groups. Modified hyrax expanders were placed across their interfrontal sutures and secured with miniscrew implants located bilaterally in the frontal bone. The hyrax appliances were activated as follows: group 1 (control), 0.5-mm per day expansion for 12 days; group 2, 1-mm instant expansion followed by 0.5 mm per day for 10 days; group 3, 2.5-mm instant expansion followed by 0.5 mm per day for 7 days, and group 4, 4-mm instant expansion followed by 0.5 mm per day for 4 days. After 6 weeks of retention, sutural separation and sutural bone modeling were assessed by microcomputed tomography and quantified. Statistical analysis was performed using Kruskal Wallis and Mann-Whitney U tests and the Spearman rho correlation (P <0.05). RESULTS: Median amounts of sutural separation ranged from 2.84 to 4.41 mm for groups 1 and 4, respectively. Median bone volume fraction ranged from 59.96% to 69.15% for groups 4 and 3, respectively. A significant correlation (r = 0.970; P <0.01) was observed between the amounts of instant expansion and sutural separation. CONCLUSIONS: Pending histologic verifications, our findings suggest that the protocol involving 2.5 mm of instant expansion followed by 0.5 mm per day for 7 days is optimal for accelerated sutural expansion. When 4 mm of instant expansion was used, the sutural bone volume fraction was decreased.


Asunto(s)
Técnica de Expansión Palatina , Hueso Paladar/diagnóstico por imagen , Microtomografía por Rayos X , Animales , Masculino , Conejos , Distribución Aleatoria , Factores de Tiempo
13.
Clin Oral Implants Res ; 28(5): 535-542, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-26989853

RESUMEN

OBJECTIVE: To determine oral health-related quality of life (OHRQoL) and denture satisfaction (DS) in patients provided with mandibular implant-supported overdentures (ISOD) retained by two different attachment types, and the association of mandibular bone volume with the change in patient-reported outcome, before and after implant treatment. MATERIAL AND METHODS: Thirty-four patients (mean age 60.70 â€¯±â€¯ 8.7 years) received telescopic crown or locator attachments for ISOD and completed OHIP-14 (Malaysian version) and DS questionnaires, at baseline (T0 ) with new conventional complete dentures (CCD) and 3 months (T1 ) and 3 years (T2 ) after ISOD conversion. Mandibular bone volume was calculated from cone beam computed tomography (CBCT) datasets using Mimics software. Mean changes (MC) in OHIP-14 and DS at intervals were analyzed using the Wilcoxon signed-rank test and effect size (ES). The association of bone volume, implant attachment type, and other patient variables with the change in OHIP-14 and DS were determined using multivariate linear regression analysis. RESULTS: The MC in OHIP-14 and DS scores from T0 to T1 and T2 showed significant improvement with moderate and large ES, respectively. Regression analyses for the change in OHIP-14 score from T0 to T2 showed significant association with implant attachment type (P = 0.043), bone volume (P = 0.004), and baseline OHIP-14 (P = 0.001), while for DS, the association was only significant with baseline DS score (P = 0.001). CONCLUSION: Improvement in patients' OHRQoL and satisfaction with ISOD was associated with their baseline ratings. Mandibular bone volume had a stronger association for improvement in OHRQoL compared to type of attachment.


Asunto(s)
Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Medición de Resultados Informados por el Paciente , Proceso Alveolar/patología , Proceso Alveolar/cirugía , Implantación Dental Endoósea/métodos , Femenino , Humanos , Masculino , Mandíbula/patología , Mandíbula/cirugía , Persona de Mediana Edad , Satisfacción del Paciente , Encuestas y Cuestionarios , Resultado del Tratamiento
15.
Clin Oral Implants Res ; 26(1): e1-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-24325572

RESUMEN

OBJECTIVES: The first purpose of this study was to analyze the correlation between bone volume fraction (BV/TV) and calibrated radiographic bone density Hounsfield units (HU) in human jaws, derived from micro-CT and multislice computed tomography (MSCT), respectively. The second aim was to assess the accuracy of cone beam computed tomography (CBCT) in evaluating trabecular bone density and microstructure using MSCT and micro-CT, respectively, as reference gold standards. MATERIAL AND METHODS: Twenty partially edentulous human mandibular cadavers were scanned by three types of CT modalities: MSCT (Philips, Best, the Netherlands), CBCT (3D Accuitomo 170, J Morita, Kyoto, Japan), and micro-CT (SkyScan 1173, Kontich, Belgium). Image analysis was performed using Amira (v4.1, Visage Imaging Inc., Carlsbad, CA, USA), 3Diagnosis (v5.3.1, 3diemme, Cantu, Italy), Geomagic (studio(®) 2012, Morrisville, NC, USA), and CTAn (v1.11, SkyScan). MSCT, CBCT, and micro-CT scans of each mandible were matched to select the exact region of interest (ROI). MSCT HU, micro-CT BV/TV, and CBCT gray value and bone volume fraction of each ROI were derived. Statistical analysis was performed to assess the correlations between corresponding measurement parameters. RESULTS: Strong correlations were observed between CBCT and MSCT density (r = 0.89) and between CBCT and micro-CT BV/TV measurements (r = 0.82). Excellent correlation was observed between MSCT HU and micro-CT BV/TV (r = 0.91). However, significant differences were found between all comparisons pairs (P < 0.001) except for mean measurement between CBCT BV/TV and micro-CT BV/TV (P = 0.147). CONCLUSIONS: An excellent correlation exists between bone volume fraction and bone density as assessed on micro-CT and MSCT, respectively. This suggests that bone density measurements could be used to estimate bone microstructural parameters. A strong correlation also was found between CBCT gray values and BV/TV and their gold standards, suggesting the potential of this modality in bone quality assessment at implant site.


Asunto(s)
Densidad Ósea , Tomografía Computarizada de Haz Cónico/métodos , Arcada Parcialmente Edéntula/diagnóstico por imagen , Mandíbula/diagnóstico por imagen , Tomografía Computarizada Multidetector/métodos , Microtomografía por Rayos X/métodos , Algoritmos , Cadáver , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados
16.
Clin Oral Implants Res ; 25(8): 941-5, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23581278

RESUMEN

OBJECTIVE: Cone-beam CT (CBCT) images are infrequently utilized for trabecular bone microstructural measurement due to the system's limited resolution. The aim of this study was to determine the accuracy of CBCT for measuring trabecular bone microstructure in comparison with micro CT (µCT). MATERIALS AND METHODS: Twenty-four human mandibular cadavers were scanned using a CBCT system (80 µm) and a µCT system (35 µm). Three bone microstructural parameters trabecular number (Tb.N), thickness (Tb.Th) and separation (Tb.Sp) were assessed using CTAn imaging software. RESULTS: Intraclass correlation coefficients (ICC) showed a high intra-observer reliability (≥ 0.996) in all parameters for both systems. The Pearson correlation coefficients between the measurements of the two systems were for Tb.Th 0.82, for Tb.Sp 0.94 and for Tb.N 0.85 (all P's<0.001). The Bland and Altman plots showed strongest agreement in Tb.N (-0.37 µm) followed by Tb.Th (1.6 µm) and Tb.Sp (8.8 µm). CONCLUSIONS: Cone-beam CT datasets can be used to evaluate trabecular bone microstructure at dental implant sites. The accuracy for measuring Tb.N was the best followed by Tb.Th and Tb.Sp.


Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Mandíbula/diagnóstico por imagen , Densidad Ósea , Cadáver , Implantes Dentales , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador
17.
Leg Med (Tokyo) ; 66: 102391, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38211402

RESUMEN

Three-dimensional surface area analyses of developing root apices for age estimation in children and young adults have shown promising results. The current study aimed to apply this three-dimensional method to develop a regression model for estimating age in Malaysian children aged 7 to 14 using developing maxillary second premolars. A training sample of 155 cone-beam computed tomography scans (83 Malays and 72 Chinese) was analysed, and the formula was subsequently validated on an independent sample of 92 cone-beam computed tomography scans (45 Malays and 47 Chinese). The results showed a strong correlation (r = 94 %) between the chronological age as a dependent variable and the predictor variables, including root surface area of the apex, sex, ethnicity, and root development status (open/closed apices). For this model, the predictor variables accounted for 88.4 % of the variation in age except sex and ethnicity. A mean absolute error value of 0.42 indicated that this model can be reliably used for Malaysian children. In conclusion, this study recognises the method of three-dimensional surface area analyses as a valuable tool for age estimation in forensic and clinical practice. Further studies are highly recommended to assess its effectiveness across different demographic groups.


Asunto(s)
Determinación de la Edad por los Dientes , Tomografía Computarizada de Haz Cónico Espiral , Niño , Humanos , Pueblo Asiatico , Diente Premolar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Maxilar/diagnóstico por imagen , Raíz del Diente/diagnóstico por imagen , Adolescente
18.
J Dent Educ ; 87(8): 1089-1098, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37164913

RESUMEN

PURPOSE: To assess the application and accuracy of two systems (Vertucci et al. 1974 and Ahmed et al. 2017) in classifying the root and canal morphology of human dentition among final-year undergraduates, interns, and postgraduate dental students in India. METHODS: The survey was conducted using physical and online presentation modes in two phases. Phase 1; PowerPoint presentation (PPT), describing the most used classification system (Vertucci et al. 1974) and its supplementary types and Ahmed et al. (2017) classification. A single presenter delivered the PPT to participants, using either a projector in an auditorium/seminar hall (face-to-face) or an online platform (zoom meeting software). Phase 2 involved determining the students' responses. A questionnaire was distributed amongst the participants after the lecture and collected for analysis. Fisher's exact test was used to analyze the data statistically, and the significance level was set at 0.05 (p < 0.05). RESULTS: A total of 1082 participants were involved in this survey. Overall, 93% of study participants found that Ahmed et al. classification system was more practical and accurate than Vertucci et al. system and its supplemental configurations (p < 0.001). About 97% agreed that Ahmed et al. classification system aided in understanding root and canal morphology better than Vertucci's and its additional configurations, and they recommended to include in their curriculum (p < 0.001). CONCLUSIONS: In comparison to Vertucci's classification system and supplementary types, the undergraduate and postgraduate dental students, and interns in India agreed that Ahmed et al. classification system is more practical and accurate for classifying the root and canal morphology.


Asunto(s)
Dentición , Raíz del Diente , Humanos , Raíz del Diente/anatomía & histología , Cavidad Pulpar/anatomía & histología , Estudiantes , India , Tomografía Computarizada de Haz Cónico
19.
J Taibah Univ Med Sci ; 17(2): 289-296, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35592796

RESUMEN

Objective: To determine the effects of repeated placement of quantified lyophilised platelet-rich plasma (LPRP) on the soft and hard tissue components. Methods: Lyophilised platelet-rich plasma was topically placed, and later injected, into fresh sockets using the third molar surgical model, randomised according to the split-mouth approach. The control site received placebo. The application of LPRP was done intraoperatively, one month and two months postoperatively. The measured endpoints included post-operative pain, swelling, trismus, pocket depth at mid-distal adjacent second molar, soft tissue healing, and bone formation (which was assessed radiographically). Fifteen healthy young adults, aged between 21 and 35 years, visiting the Oral and Maxillofacial Surgery Clinic at the University of Malaya were recruited for this study. Results: There was no significant difference in post-operative pain, swelling size, trismus, and bone healing within their specific timelines during this study. However, the LPRP group showed significant reduction in pocket depth at the two-month post-operative period, suggesting that LPRP improves soft tissue healing. Conclusion: Soft tissue healing, measured as the change of periodontal pocket depth, showed significant reduction, suggesting the benefit of LPRP for soft tissue healing. However, bone regeneration and reduction of post-operative sequelae showed no improvement even after quantification and repeated LPRP application.

20.
Biology (Basel) ; 11(10)2022 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-36290424

RESUMEN

The aim of this study is two-fold: first, to correlate the values for each of the trabecular bone microstructure (TBM) parameters to the individual's chronological age and sex, thereby facilitating the assessment of potential age and sex-related changes in trabecular bone microstructure parameters in the mandible; and second, to quantify the trabecular microstructural parameters in relation to chronological age. Twenty cone-beam computed tomographic (CBCT) scans were retrieved retrospectively from a database of adult patients with ages ranging in age from 22 to 43 years. In the mandible, the volume of interest included the inter-dental space between the second mandibular premolar and the first mandibular molar, as well as the trabecular space beneath and between the apices. Using the AnalyzeDirect 14.0 software, the DICOM images of CBCT scans were pre-processed, transformed, segmented using a novel semi-automatic threshold-guided method, and quantified. In addition, TBM parameters were derived, and statistical analysis was conducted using a Pearson correlation test with two tails. All parameters exhibited no statistically significant differences (p > 0.05) between chronological age and sex. Statistically significant negative correlations were found between Tb. N (r = −0.489), BS/TV (r = −0.527), and chronological age (p = 0.029 and p = 0.017, respectively). Only Tb. N and BS/TV exhibited an inverse relationship with chronological age. Numerous studies have quantified the trabecular architecture of the jaw bones, but none have found a correlation between the quantified trabecular parameters and chronological age. The digital imprints produced by radiographic imaging can serve as biological profiles for data collection.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA