Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Heart ; 108(16): 1310-1318, 2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35012960

RESUMEN

OBJECTIVE: The primary objective was to assess the performance of a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer in an all comer population. The secondary objective was to detail differences in contemporary percutaneous coronary intervention (PCI) practice worldwide. METHODS: e-Ultimaster was an all-comer, prospective, global registry (NCT02188355) with independent event adjudication enrolling patients undergoing PCI with the study stent. The primary outcome measure was target lesion failure (TLF) at 1 year, defined as the composite of cardiac death, target vessel myocardial infarction and clinically driven target lesion revascularisation. Data were stratified according to 4 geographical regions. RESULTS: A total of 37 198 patients were enrolled (Europe 69.2%, Asia 17.8%, Africa/Middle East 6.6% and South America/Mexico 6.5%) and 1-year follow-up was available for 35 389 patients (95.1%). One-year TLF occurred in 3.2% of the patients, ranging from 2% (Africa/Middle East) to 4.1% (South America/Mexico). In patients with acute coronary syndrome, potent P2Y12 inhibitors were prescribed in 48% of patients at discharge, while at 1 year 72% were on any dual antiplatelet therapy. Lipid-lowering treatment was administered in 80.9% and 75.5% of patients at discharge and 1 year, respectively. Regional differences in the profile of the treated patients as well as in PCI practice were reported. CONCLUSIONS: In this investigation with worldwide representation, contemporary PCI using a new generation thin-strut sirolimus-eluting coronary stent with abluminal biodegradable polymer was associated with low 1-year TLF across clinical presentations and continents. Suboptimal adherence to current recommendations around antiplatelet and lipid lowering treatments was detected.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Lípidos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Sistema de Registros , Sirolimus/uso terapéutico , Stents , Resultado del Tratamiento
2.
EuroIntervention ; 14(3): e343-e351, 2018 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-29790479

RESUMEN

AIMS: The aim of this study was to establish the long-term safety and efficacy of a sirolimus-eluting stent with bioresorbable polymer (BP-SES; Ultimaster) by comparison with an everolimus-eluting stent with permanent polymer (PP-EES; XIENCE). METHODS AND RESULTS: CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) is a large-scale, prospective, multicentre, randomised single-blind, controlled, non-inferiority trial conducted at 58 study sites globally, including Europe, Japan and Korea, powered to prove non-inferiority for freedom from target lesion failure (TLF: cardiac death, target vessel-related myocardial infarction [MI] and target lesion revascularisation) at nine months. Patients requiring a percutaneous coronary intervention (PCI) were randomised (1:1) to BP-SES (n=551) or PP-EES (n=550). Freedom from TLF at five years was 90.0% in the BP-SES and 91.1% in the PP-EES group (p=0.54). The patient-oriented composite endpoint (all death, any MI, any revascularisation) was 24.1 and 25.6% (p=0.57) with BP-SES and PP-EES, respectively. The very late stent thrombosis rate from one to five years was especially low at 0.2% in both arms. CONCLUSIONS: This randomised clinical trial showed that the BP-SES stent was non-inferior to the benchmark PP-EES stent for TLF. Safety and efficacy measures were comparable up to five-year follow-up after PCI.


Asunto(s)
Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Implantes Absorbibles , Europa (Continente) , Humanos , Japón , Polímeros , Estudios Prospectivos , Diseño de Prótesis , República de Corea , Método Simple Ciego , Resultado del Tratamiento
3.
EuroIntervention ; 14(5): e570-e579, 2018 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-28994655

RESUMEN

AIMS: Quantitative flow ratio (QFR) based on three-dimensional quantitative coronary angiography (3D-QCA) is a novel method to assess physiological functionality after treatment with stents. The current study aimed to evaluate the difference in physiological functionality nine months after implantation of a bioresorbable polymer-based sirolimus-eluting stent with an electrografting base layer (BuMA Supreme: B-SES) versus a durable polymer-based zotarolimus-eluting stent (Resolute: R-ZES). METHODS AND RESULTS: The current post hoc analysis was performed in the PIONEER randomised trial (1:1 randomisation to B-SES [83 patients/95 lesions] and R-ZES [87 patients/101 lesions]). QFR was measured in stented vessels in both arms at preprocedural, post-procedural and nine-month angiography without pharmacologically induced hyperaemia (contrast QFR). At nine months, both the values of QFR distal to the stent (B-SES: 0.89±0.10 vs. R-ZES: 0.89±0.11, p=0.97) and the number of vessels with QFR ≤0.8 were not significantly different between the two groups (11.0% vs. 12.8%, p=0.72), while the in-stent binary restenosis rate was also comparable (3.7% vs. 3.5%, p=1.00). QFR gradient across the device (∆QFR) at nine months was also similar between the groups (B-SES: 0.03±0.04 vs. R-ZES: 0.03±0.07, p=0.95). CONCLUSIONS: Quantitative flow assessment nine months after stenting did not differ between B-SES and R-ZES, despite a significant difference in in-stent late lumen loss.


Asunto(s)
Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Angiografía Coronaria , Humanos , Polímeros , Diseño de Prótesis , Sirolimus/análogos & derivados , Stents , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA