Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Catheter Cardiovasc Interv ; 95 Suppl 1: 587-597, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31943693

RESUMEN

OBJECTIVES: To report the clinical outcomes of the RESTORE drug-coated balloon (DCB; Cardionovum, Bonn, Germany) for treatment of de novo small vessel disease (SVD) beyond 1 year. BACKGROUND: Previous reports have demonstrated the noninferiority of the RESTORE DCB to the RESOLUTE Integrity drug-eluting stent (DES; Medtronic, Minneapolis, Minnesota) in terms of 9-month in-segment percent diameter stenosis. METHODS: In the prospective, multicenter, noninferiority RESTORE SVD China trial, 230 patients with visually-estimated reference vessel diameter (RVD) ≥2.25 and ≤2.75 mm were randomized to DCB or DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Furthermore, 32 patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel (VSV) registry. Clinical follow-up were performed at 2 years to evaluate target lesion failure (TLF) in both groups and the VSV cohort. RESULTS: Overall, 256 (97.7%) patients (115 and 109 in the DCB and DES groups, respectively, and 32 in the VSV cohort) completed 2 years of follow-up. There was no significant difference in TLF between the DCB and DES groups (5.2 vs. 3.7%, p = .75). Target lesion revascularization was acceptable at 1 month, 1 year, and 2 years, and did not differ significantly with DCB from that in the DES group (0.9 vs. 0%, p = 1.0, 4.4 vs. 2.6%, p = .72, 5.2 vs. 2.8%, p = .50, respectively). CONCLUSIONS: Compared to the second-generation DES, the RESTORE DCB did not increase the risk of clinical outcomes. Late catch-up phenomen requiring revascularization was not significant in this study.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , China , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
JACC Cardiovasc Interv ; 11(23): 2368-2377, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30522665

RESUMEN

OBJECTIVES: The aim of the present study was to evaluate the angiographic efficacy, clinical safety, and effectiveness of the Restore paclitaxel-coated balloon in a randomized trial designed to enable the approval of the new device in China. BACKGROUND: Drug-coated balloon (DCB) angioplasty offers an effective treatment for in-stent restenosis. Restore is a new DCB with a SAFEPAX shellac-ammonium salt excipient that can avoid drug washing off during catheter delivery to the target lesion site. METHODS: In the noninferiority RESTORE ISR China (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis) trial, eligible patients with first occurrence of drug-eluting stent ISR were randomized to the Restore DCB or SeQuent Please DCB in a 1:1 ratio stratified by diabetes. Angiographic and clinical follow-up was planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment late loss. RESULTS: Between May 2016 and July 2017, a total of 240 subjects at 12 sites were randomized to either the Restore group (n = 120) or the SeQuent Please group (n = 120). Nine-month in-segment late loss was 0.38 ± 0.50 mm with Restore versus 0.35 ± 0.47 mm with SeQuent Please; the 1-sided 97.5% upper confidence limit of the difference was 0.17 mm, achieving noninferiority of Restore compared with SeQuent Please (p for noninferiority = 0.02). Both DCBs had similar 1-year rates of target lesion failure (13.3% vs. 12.6%; p = 0.87). CONCLUSIONS: In this head-to-head randomized trial, the Restore DCB was noninferior to the SeQuent Please DCB for the primary endpoint of 9-month in-segment late loss. (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis; NCT02944890).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , China , Constricción Patológica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
JACC Cardiovasc Interv ; 11(23): 2381-2392, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30522667

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the angiographic efficacy and clinical outcomes of the Restore paclitaxel-coated balloon in a randomized trial designed to enable its approval with an indication for small-vessel disease (SVD). BACKGROUND: Higher rates of restenosis and stent thrombosis limit the effectiveness of drug-eluting stent (DES) treatment of SVD. Whether a drug-coated balloon (DCB)-only strategy is effective in de novo SVD is not yet established. METHODS: In the noninferiority RESTORE SVD China trial, eligible patients with reference vessel diameter ≥2.25 and ≤2.75 mm were randomized to the Restore DCB or the RESOLUTE Integrity DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel registry. Angiographic and clinical follow-up were planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment percentage diameter stenosis. RESULTS: Between August 2016 and June 2017, a total of 230 subjects at 12 sites were randomized to the DCB group (n = 116) or DES group (n = 114); 32 patients were treated with the DCB in the very small vessel cohort. Nine-month in-segment percentage diameter stenosis was 29.6 ± 2.0% with the DCB versus 24.1 ± 2.0% with the DES; the 1-sided 97.5% upper confidence limit of the difference was 10.9%, achieving noninferiority of the DCB compared with the DES (p for noninferiority < 0.001). The DCB and DES had comparable 1-year rates of target lesion failure (4.4% vs. 2.6%, p = 0.72). CONCLUSIONS: In this multicenter randomized trial, the Restore DCB was noninferior to the RESOLUTE DES for 9-month in-segment percentage diameter stenosis. (Assess the Efficacy and Safety of RESTORE Paclitaxel Eluting Balloon Versus RESOLUTE Zotarolimus Eluting Stent for the Treatment of Small Coronary Vessel Disease; NCT02946307).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , China , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA