Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Mar Drugs ; 21(12)2023 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-38132932

RESUMEN

The inherent self-repair abilities of the body often fall short when it comes to addressing injuries in soft tissues like skin, nerves, and cartilage. Tissue engineering and regenerative medicine have concentrated their research efforts on creating natural biomaterials to overcome this intrinsic healing limitation. This comprehensive review delves into the advancement of such biomaterials using substances and components sourced from marine origins. These marine-derived materials offer a sustainable alternative to traditional mammal-derived sources, harnessing their advantageous biological traits including sustainability, scalability, reduced zoonotic disease risks, and fewer religious restrictions. The use of diverse engineering methodologies, ranging from nanoparticle engineering and decellularization to 3D bioprinting and electrospinning, has been employed to fabricate scaffolds based on marine biomaterials. Additionally, this review assesses the most promising aspects in this field while acknowledging existing constraints and outlining necessary future steps for advancement.


Asunto(s)
Materiales Biocompatibles , Andamios del Tejido , Animales , Ingeniería de Tejidos/métodos , Medicina Regenerativa/métodos , Mamíferos
2.
J Nanobiotechnology ; 13: 21, 2015 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-25886153

RESUMEN

BACKGROUND: Electrospinning is a simple and effective method for fabricating micro- and nanofiber matrices. Electrospun fibre matrices have numerous advantages for use as tissue engineering scaffolds, such as high surface area-to-volume ratio, mass production capability and structural similarity to the natural extracellular matrix (ECM). Therefore, electrospun matrices, which are composed of biocompatible polymers and various biomaterials, have been developed as biomimetic scaffolds for the tissue engineering applications. In particular, graphene oxide (GO) has recently been considered as a novel biomaterial for skeletal muscle regeneration because it can promote the growth and differentiation of myoblasts. Therefore, the aim of the present study was to fabricate the hybrid fibre matrices that stimulate myoblasts differentiation for skeletal muscle regeneration. RESULTS: Hybrid fibre matrices composed of poly(lactic-co-glycolic acid, PLGA) and collagen (Col) impregnated with GO (GO-PLGA-Col) were successfully fabricated using an electrospinning process. Our results indicated that the GO-PLGA-Col hybrid matrices were comprised of randomly-oriented continuous fibres with a three-dimensional non-woven porous structure. Compositional analysis showed that GO was dispersed uniformly throughout the GO-PLGA-Col matrices. In addition, the hydrophilicity of the fabricated matrices was significantly increased by blending with a small amount of Col and GO. The attachment and proliferation of the C2C12 skeletal myoblasts were significantly enhanced on the GO-PLGA-Col hybrid matrices. Furthermore, the GO-PLGA-Col matrices stimulated the myogenic differentiation of C2C12 skeletal myoblasts, which was enhanced further under the culture conditions of the differentiation media. CONCLUSIONS: Taking our findings into consideration, it is suggested that the GO-PLGA-Col hybrid fibre matrices can be exploited as potential biomimetic scaffolds for skeletal tissue engineering and regeneration because these GO-impregnated hybrid matrices have potent effects on the induction of spontaneous myogenesis and exhibit superior bioactivity and biocompatibility.


Asunto(s)
Materiales Biomiméticos/química , Colágeno/química , Grafito/química , Ácido Láctico/química , Mioblastos/citología , Ácido Poliglicólico/química , Animales , Adhesión Celular , Técnicas de Cultivo de Célula/métodos , Diferenciación Celular , Proliferación Celular , Matriz Extracelular/química , Ratones , Microscopía de Fuerza Atómica , Microscopía Electrónica de Rastreo , Músculo Esquelético/citología , Copolímero de Ácido Poliláctico-Ácido Poliglicólico , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Andamios del Tejido , Difracción de Rayos X
3.
Bioengineering (Basel) ; 11(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38671758

RESUMEN

The purposes of this study are to establish and validate a finite element (FE) model using finite element analysis methods and to identify optimal loading conditions to simulate masticatory movement. A three-dimensional FE model of the maxillary and mandibular cortical bone, cancellous bone, and gingiva was constructed based on edentulous cone-beam-computed tomography data. Dental computer-aided design software was used to design the denture base and artificial teeth to produce a complete denture. Mesh convergence was performed to derive the optimal mesh size, and validation was conducted through comparison with mechanical test results. The mandible was rotated step-by-step to induce movements similar to actual mastication. Results showed that there was less than a 6% difference between the mechanical test and the alveolar bone-complete denture. It opened 10° as set in the first stage, confirming that the mouth closed 7° in the second stage. Occlusal contact occurred between the upper and lower artificial teeth as the mouth closed the remaining angle of 3° in the third stage while activating the masseter muscle. These results indicate that the FE model and masticatory loading conditions developed in this study can be applied to analyze biomechanical effects according to the wearing of dentures with various design elements applied.

4.
Biotechnol Appl Biochem ; 60(6): 580-8, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23772797

RESUMEN

This study concentrates on the potential application of conjugated polyelectrolytes (CPEs) to cell imaging and DNA delivery. Four different types of polyfluorene copolymers, namely, PAHFP-Br, PAEFP-Br, PAHFbT-Br, and PSBFP-Na, which have the same π-conjugated backbone but different side chains, were synthesized. For cytotoxicity testing, L-929 fibroblastic cells were treated with increasing concentrations (0-50 µM) of each CPE and then cell viability was determined by WST-8 assay. Cellular uptake of CPEs into cultured L-929 cells was observed by fluorescence microscopy. To examine DNA delivery by CPEs, the cells were incubated for 1 H with PAHFP-Br/fluorescein (Fl)-labeled single-stranded DNA (ssDNA-Fl) complex and then visualized by fluorescence microscopy. Cytotoxicity of CPEs was increased in a dose-dependent manner but at lower than 10 µM, PAHFP-Br, PAEFP-Br, and PSBFP-Na did not show any cytotoxic effects on the cells. When added to cell cultures at 1 µM, PAHFP-Br/ssDNA-Fl complex was delivered and then dissociated into PAHFP-Br and ssDNA-Fl within the cells. This result implies that PAHFP-Br can enable cell imaging and DNA delivery into fibroblastic cells. Therefore, it is suggested that PAHFP-Br with various advantages such as low cytotoxicity and high fluorescence efficiency can be extensively used as a potential agent for cell imaging and gene delivery.


Asunto(s)
ADN/química , ADN/metabolismo , Portadores de Fármacos/química , Fibroblastos/citología , Fibroblastos/metabolismo , Técnicas de Transferencia de Gen , Imagen Molecular/métodos , Polímeros/química , Animales , Transporte Biológico , Línea Celular , Supervivencia Celular/efectos de los fármacos , ADN/genética , Portadores de Fármacos/metabolismo , Portadores de Fármacos/toxicidad , Fluorenos/química , Ratones , Fenómenos Ópticos , Polímeros/metabolismo , Polímeros/toxicidad
5.
Bioengineering (Basel) ; 10(12)2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38135955

RESUMEN

Computer modeling and simulation (CM&S) technology is widely used in the medical device industry due to its advantages such as reducing testing time and costs. However, the developer's parameter settings during the modeling and simulation process can have a significant impact on the results. This study developed a test model for the rotational shear strength of dental implants and the constraint force of total knee replacements based on CM&S technology and proposes ideal parameters to ensure reliability. For dental implants, the load area and sliding contact conditions were considered, and for total knee replacements, the friction coefficient, medial-lateral displacement, valgus-varus rotation, and elastic modulus were considered. By comparing the simulation results and mechanical tests, boundary conditions with an error rate of less than 1.5% were selected. When a jig (gripper and collector) was applied with the same boundary conditions, an error rate of 48~22% occurred; otherwise, it was confirmed that the error rate was within 10~0.2%. The FE model was verified with an error of 2.49 to 3% compared to the mechanical test. The friction coefficient variable had the greatest influence on the results, accounting for 10 to 13%, and it was confirmed that valgus-varus rotation had a greater influence on the results than medial-lateral displacement. Relatively, the elastic modulus of the insert had the least effect on the results. These research results are expected to make CM&S techniques useful as a medical device digital development tool (M3DT) in the development of total knee replacements and dental implants.

6.
Dent Mater ; 38(10): 1648-1660, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36075761

RESUMEN

BACKGROUND: The purpose of this study was to establish a mechanical and histological basis for the development of biocompatible maxillofacial reconstruction implants by combining 3D-printed porous titanium structures and surface treatment. Improved osseointegration of 3D-printed titanium implants for reconstruction of maxillofacial segmental bone defect could be advantageous in not only quick osseointegration into the bone tissue but also in stabilizing the reconstruction. METHODS: Various macro-mesh titanium scaffolds were fabricated by 3D-printing. Human mesenchymal stem cells were used for cell attachment and proliferation assays. Osteogenic differentiation was confirmed by quantitative polymerase chain reaction analysis. The osseointegration rate was measured using micro computed tomography imaging and histological analysis. RESULTS: In three dimensional-printed scaffold, globular microparticle shape was observed regardless of structure or surface modification. Cell attachment and proliferation rates increased according to the internal mesh structure and surface modification. However, osteogenic differentiation in vitro and osseointegration in vivo revealed that non-mesh structure/non-surface modified scaffolds showed the most appropriate treatment effect. CONCLUSION: 3D-printed solid structure is the most suitable option for maxillofacial reconstruction. Various mesh structures reduced osteogenesis of the mesenchymal stem cells and osseointegration compared with that by the solid structure. Surface modification by microarc oxidation induced cell proliferation and increased the expression of some osteogenic genes partially; however, most of the markers revealed that the non-anodized solid scaffold was the most suitable for maxillofacial reconstruction.


Asunto(s)
Implantes Dentales , Oseointegración , Humanos , Osteogénesis , Impresión Tridimensional , Propiedades de Superficie , Titanio/química , Microtomografía por Rayos X
7.
Colloids Surf B Biointerfaces ; 199: 111528, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33385823

RESUMEN

Three-dimensional (3D) bioprinting is a free-form fabrication technique enabling fine feature control for tissue engineering applications. Especially, 3D scaffolds capable of supporting cell attachment, proliferation, and osteogenic differentiation are a prerequisite for bone tissue regeneration. Herein, we elaborated this approach to produce a 3D polycaprolactone (PCL) scaffold with long-term osteogenic activity. Specifically, we coated polydopamine (PDA) on 3D PCL scaffolds, subsequently deposited hydroxyapatite (HA) nanoparticles via biomimetic mineralization, and finally immobilized bone morphogenetic protein-2 (BMP-2). Material properties were characterized and compared with various 3D scaffolds, including PCL, PDA-coated PCL (PCL/PDA), and PDA-coated and HA-deposited PCL (PCL/PDA/HA). In vitro cell culture studies with osteoblasts revealed that the PCL/PDA/HA scaffolds immobilized with BMP-2 showed long-term retention of BMP-2 (for up to 21 days) and significantly increased osteoblast proliferation and osteogenic differentiation, as evidenced by metabolic activity, alkaline phosphatase activity, and calcium deposition. We believe that this multifunctional osteogenic 3D scaffold will be useful for bone tissue engineering applications.


Asunto(s)
Biomineralización , Osteogénesis , Huesos , Diferenciación Celular , Indoles , Poliésteres , Polímeros , Impresión Tridimensional , Ingeniería de Tejidos , Andamios del Tejido
8.
Materials (Basel) ; 14(2)2021 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-33435457

RESUMEN

Lately, in orthodontic treatments, the use of transparent aligners for the correction of malocclusions has become prominent owing to their intrinsic advantages such as esthetics, comfort, and minimal maintenance. Attempts at improving upon this technology by varying various parameters to investigate the effects on treatments have been carried out by several researchers. Here, we aimed to investigate the biomechanical and clinical effects of aligner thickness on stress distributions in the periodontal ligament and changes in the tooth's center of rotation. Dental finite element models comprising the cortical and cancellous bones, gingiva, teeth, and nonlinear viscoelastic periodontal ligaments were constructed, validated, and used together with aligner finite element models of different aligner thicknesses to achieve the goal of this study. The finite element analyses were conducted to simulate the actual orthodontic aligner treatment process for the correction of malocclusions by generating pre-stresses in the aligner and allowing the aligner stresses to relax to induce tooth movement. The results of the analyses showed that orthodontic treatment in lingual inclination and axial rotation with a 0.75 mm-thick aligner resulted in 6% and 0.03% higher principal stresses in the periodontal ligament than the same treatment using a 0.05 mm-thick aligner, respectively. Again, for both aligner thicknesses, the tooth's center of rotation moved lingually and towards the root direction in lingual inclination, and diagonally from the long axis of the tooth in axial rotation. Taken together, orthodontic treatment for simple malocclusions using transparent aligners of different thicknesses will produce a similar effect on the principal stresses in the periodontal ligament and similar changes in the tooth's center of rotation, as well as sufficient tooth movement. These findings provide orthodontists and researchers clinical and biomechanical evidence about the effect of transparent aligner thickness selection and its effect on orthodontic treatment.

9.
Materials (Basel) ; 13(7)2020 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-32230822

RESUMEN

Mechanical testing based on ISO 14801 standard is generally used to evaluate the performance of the dental implant system according to material and design changes. However, the test method is difficult to reflect on the clinical environment because the ISO 14801 standard does not take into account the various loads from different directions during chewing motion. In addition, the fracture pattern of the implant system can occur both in the horizontal and the vertical directions. Therefore, the purpose of this study was to compare fatigue characteristics and fracture patterns between single directional loading conditions based on the ISO 14801 standard and multi-directional loading condition. Firstly, the static test was performed on five specimens to derive the fatigue load, and the fatigue load was chosen as 40% of the maximum load measured in the static test. Subsequently, the fatigue test was performed considering the single axial/occlusal (AO), AO with facial/lingual (AOFL) and AO with mesial/distal (AOMD) directions, and five specimens were used for each fatigue loading modes. In order to analyze the fatigue characteristics, the fatigue cycle at the time of specimen fracture and displacement change of the specimen every 500 cycles were measured. Field emission scanning electron microscopy (FE-SEM) was used to analyze the fracture patterns and the fracture surface. Compared to the AO group, the fatigue cycle of the AOFL and AOMD groups showed lower about five times, while the displacement gradually increased with every 500 cycles. From FE-SEM results, there were no different surface morphology characteristics among three groups. However, the AOMD group showed a vertical slip band. Therefore, our results suggest that the multi-directional loading mode under the worst-case environment can reproduce the vertical fracture pattern in the clinical situation and may be essential to reflect on the dental implant design including connection types and surface treatments.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA