Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Analyst ; 147(16): 3783-3794, 2022 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-35876175

RESUMEN

In this study, parylene-C films from plasma deposition as well as thermal deposition were pyrolyzed to prepare a carbon electrode for application in electrochemical immunoassays. Plasma deposition could prepare parylene-C in a faster deposition rate and more precise control over the thickness in comparison with the conventional thermal deposition. To analyze the influence of the deposition method, the crystal and electronic structures of the pyrolyzed parylene-C films obtained via both deposition methods were compared using Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and Raman spectroscopy. For application as a carbon electrode in immunoassays, the electrochemical properties of the pyrolyzed carbon films from two both deposition methods were analyzed, including the double layer capacitance (2.10 µF cm-2 for plasma deposition and 2.20 µF cm-2 for thermal deposition), the apparent electron transfer rate (approximately 1.1 × 10-3 cm s-1 for both methods), and the electrochemical window (approximately -1.0 ∼ 2.1 V for both methods). Finally, the applicability of the pyrolyzed carbon electrode from parylene-C was demonstrated for the diagnosis of human hepatitis-C using various amperometric methods, such as cyclic voltammetry, chronoamperometry, square-wave voltammetry and differential pulse voltammetry.


Asunto(s)
Carbono , Pirólisis , Carbono/química , Electrodos , Humanos , Inmunoensayo , Polímeros , Xilenos
2.
Int J Med Sci ; 18(2): 432-440, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33390812

RESUMEN

Prevotella nigrescens is an oral pathogen that is frequently observed in the subgingival plaque of periodontitis patients. Interleukin-1ß (IL-1ß) is known to be involved in the immunopathology of periodontal diseases and has been implicated in the destruction of bone. In this study, we investigated the mechanism of IL-1ß production by P. nigrescens in murine bone marrow-derived dendritic cells (BMDCs). Our results showed that a host receptor, Toll-like receptor 2 (TLR2), but not TLR4 is required for pro-IL-1ß induction and nucleotide-binding oligomerization domain like receptor pyrin domain containing 3 (NLRP3) priming in BMDCs in response to P. nigrescens and activation of the NLRP3 inflammasome is necessary for processing of pro-IL-1ß into mature IL-1ß. In addition, an inhibitor assay revealed that production of reactive oxygen species, P2X7R activity, and release of cathepsin B are involved in IL-1ß production in BMDCs in response to P. nigrescens.


Asunto(s)
Infecciones por Bacterias Gramnegativas/inmunología , Interleucina-1beta/metabolismo , Proteína con Dominio Pirina 3 de la Familia NLR/metabolismo , Periodontitis/inmunología , Prevotella nigrescens/inmunología , Receptor Toll-Like 2/metabolismo , Animales , Catepsina B/metabolismo , Células Cultivadas , Células Dendríticas/inmunología , Células Dendríticas/metabolismo , Modelos Animales de Enfermedad , Infecciones por Bacterias Gramnegativas/microbiología , Humanos , Inflamasomas/inmunología , Inflamasomas/metabolismo , Ratones , Proteína con Dominio Pirina 3 de la Familia NLR/genética , Periodontitis/microbiología , Cultivo Primario de Células , Especies Reactivas de Oxígeno/metabolismo , Receptores Purinérgicos P2X7/metabolismo , Transducción de Señal/genética , Transducción de Señal/inmunología , Receptor Toll-Like 2/genética
3.
Anal Chem ; 91(22): 14719-14727, 2019 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-31621295

RESUMEN

In this work, medical diagnosis of sepsis was conducted via quantitative analysis of lysophosphatidylcholine 16:0 (LPC 16:0) by using matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry based on a parylene-matrix chip. In the first step, specific mass peaks for the diagnosis of sepsis were searched by comparing MALDI-TOF mass spectra of sepsis patient sera with healthy controls and pneumonia patient sera. Two mass peaks at m/z = 496.3 and 518.3 were chosen as those that are specifically different for sepsis sera to compare with healthy controls and pneumonia patient sera. These mass peaks were identified to be protonated and sodium adducts of LPC 16:0 by using tandem mass spectra (MS2 and MS3) of purely synthesized LPC 16:0 and extracted LPC 16:0 from a healthy control and a sepsis patient. In the next step, a standard curve for LPC 16:0 for the quantitative analysis of LPC 16:0 with MALDI-TOF MS based on the parylene-matrix chip was prepared, and the statistical correlation to the LC-MS analysis results was demonstrated by using the Bland-Altman test and Passing-Bablok regression. Finally, MALDI-TOF MS based on the parylene-matrix chip was used for the quantification of LPC 16:0 with sera from patients with severe sepsis and septic shock (n = 143), pneumonia patients (n = 12), and healthy sera (n = 31). The sensitivity and the selectivity of medical diagnosis of sepsis was estimated to be 97.9% and 95.5% by using MALDI-TOF MS based on the parylene-matrix chip, respectively.


Asunto(s)
Lisofosfatidilcolinas/sangre , Polímeros/química , Sepsis/diagnóstico , Xilenos/química , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Femenino , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
4.
Anal Biochem ; 530: 31-39, 2017 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-28465033

RESUMEN

Newborn screening for diagnosis of phenylketonuria, homocystinuria, and maple syrup urine disease have been conducted by analyzing the concentration of target amino acids using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-ToF MS) based on parylene-matrix chip. Parylene-matrix chip was applied to MALDI-ToF MS analysis reducing the matrix peaks significantly at low mass-to-charge ratio range (m/z < 500). Reproducibility of inter-spot and intra-spot analyses of amino acids was less than 10%. Methanol extraction was adopted for simple and rapid sample preparation of serum before mass spectrometric analysis showing 13.3 to 45% of extraction efficiency. Calibration curves for diagnosis of neonatal metabolic disorders were obtained by analyzing methanol-extracted serum spiked with target amino acids using MALDI-ToF MS. They showed good linearity (R2 > 0.98) and the LODs were ranging from 9.0 to 22.9 µg/mL. Effect of proteins in serum was estimated by comparing MALDI-ToF mass spectra of amino acids-spiked serum before and after the methanol extraction. Interference of other amino acids on analysis of target analyte was determined to be insignificant. From these results, MALDI-ToF MS based on parylene-matrix chip could be applicable to medical diagnosis of neonatal metabolic disorders.


Asunto(s)
Aminoácidos/sangre , Tamizaje Neonatal/métodos , Polímeros/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Xilenos/química , Aminoácidos/química , Humanos , Recién Nacido , Límite de Detección , Reproducibilidad de los Resultados
5.
Rapid Commun Mass Spectrom ; 28(3): 274-80, 2014 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-24375878

RESUMEN

RATIONALE: In matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS), analyte molecules are known to be ionized by mixing with organic matrix molecules. As the organic matrix molecules are ionized, they generate unreproducible mass peaks such that MALDI-TOF MS is nearly impossible in the low mass-to-charge (m/z) range (<1000). In this work, we aimed to develop a parylene-matrix chip for the detection of small molecules in the low m/z range by using MALDI-TOF MS. METHODS: The parylene-matrix chip was fabricated by the deposition of a partially porous parylene-N thin film on a dried organic matrix array. The properties of the parylene thin film were analyzed by atomic force microscopy (AFM) and cyclic voltammetry (CV). Mass spectrometry was performed by using a parylene-matrix chip with eight amino acids as model analytes. RESULTS: The surface roughness and the electric conductivity of the parylene-N film were analyzed by AFM and CV analysis to determine its suitability for a parylene-matrix chip. The ionization of samples on the parylene-matrix chip was optimized by adjusting the laser intensity. The feasibility of applying a parylene-matrix chip for small molecule analysis was tested by using eight kinds of amino acids as model analytes and the simultaneous detection of multiple analytes from the amino acid mixture was also demonstrated. CONCLUSIONS: The parylene-matrix chip can be applied for the detection of multiple analytes in the m/z ratio range of small molecules (<1000) using MALDI-TOF MS.


Asunto(s)
Polímeros/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Xilenos/química , Aminoácidos/análisis , Aminoácidos/química , Límite de Detección , Reproducibilidad de los Resultados
6.
Rapid Commun Mass Spectrom ; 28(21): 2301-6, 2014 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-25279743

RESUMEN

RATIONALE: In matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry (MS), volatile small molecules have been nearly impossible to analyze because (1) such molecules evaporate under drying and vacuum conditions and (2) the organic matrix creates matrix peaks in the low mass-to-charge (m/z) range (m/z <500). In this work, the analysis of volatile small molecules using MALDI-TOFMS was realized using (1) a parylene-matrix chip to eliminate the matrix peaks of the organic matrix and (2) graphene for the effective adsorption of the small volatile molecules. METHODS: The parylene-matrix chip was produced by deposition of a partially porous parylene-N thin film on a dried organic matrix array. The sample solution of volatile small molecules was mixed with the graphene and then placed on the parylene-matrix chip for MALDI-TOFMS. Analogs of chemical agents called dimethyl methyl phosphonate (DMMP) and 2-chloroethylethylsulfide (CEES) were used as model compounds for the small volatile molecules, and the sensing parameters were estimated, such as the limit of detection (LOD) and the detection range. RESULTS: MALDI-TOFMS based on the parylene-matrix chip and graphene as the adsorbent could achieve a LOD of approximately 1 ppb in the detection range of 1 ppm-1 ppb for the highly volatile DMMP and CEES. CONCLUSIONS: The parylene-matrix chip with graphene can be applied for the detection of volatile small molecule analytes in the m/z ratio range of small molecules (m/z <500) using graphene as an effective adsorbent.


Asunto(s)
Grafito/química , Polímeros/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Compuestos Orgánicos Volátiles/análisis , Xilenos/química , Límite de Detección , Modelos Químicos , Compuestos Organofosforados/análisis , Compuestos Organofosforados/química , Compuestos Orgánicos Volátiles/química
7.
ACS Appl Bio Mater ; 6(9): 3726-3738, 2023 09 18.
Artículo en Inglés | MEDLINE | ID: mdl-37647153

RESUMEN

In this study, the influence of microenvironments on antibody production of hybridoma cells was analyzed using six types of functionalized parylene films, parylene-N and parylene-C (before and after UV radiation), parylene-AM, and parylene-H, and using polystyrene as a negative control. Hybridoma cells were cultured on modified parylene films that produced a monoclonal antibody against the well-known fungal toxin ochratoxin-A. Surface properties were analyzed for each parylene film, such as roughness, chemical functional groups, and hydrophilicity. The proliferation rate of the hybridoma cells was observed for each parylene film by counting the number of adherent cells, and the total amount of produced antibodies from different parylene films was estimated using indirect ELISA. In comparison with the polystyrene, the antibody-production by parylene-H and parylene-AM was estimated to be observed to be as high as 210-244% after the culture of 24 h. These results indicate that the chemical functional groups of the culture plate could influence antibody production. To analyze the influence of the microenvironments of the modified parylene films, we performed cell cycle analysis to estimate the ratio of the G0/G1, S, and G2/M phases of the hybridoma cells on each parylene film. From the normalized proportion of phases of the cell cycle, the difference in antibody production from different surfaces was considered to result from the difference in the proliferation rate of hybridoma cells, which occurred from the different physical and chemical properties of the parylene films. Finally, protein expression was analyzed using an mRNA array to determine the effect of parylene films on protein expression in hybridoma cells. The expression of three antibody production-related genes (CD40, Sox4, and RelB) was analyzed in hybridoma cells cultured on modified parylene films.


Asunto(s)
Formación de Anticuerpos , Poliestirenos , Hibridomas , Anticuerpos Monoclonales
8.
Materials (Basel) ; 15(19)2022 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-36234230

RESUMEN

This study evaluated the effects of the light intensity of curing and the post-curing duration on the mechanical properties and accuracy of the interim dental material. After designing the specimen, 3D printing was performed, and the light intensity was divided into groups G20, G60, G80, and G120 (corresponding to 1.4−1.6, 2.2−3.0, 3.8−4.4, and 6.4−7.0 mW/cm2, respectively), with no post-curing or 5, 10, or 20 min of post-curing being performed. The flexural properties, Vickers microhardness, degree of conversion (DC), and 3D accuracy were then evaluated. The flexural properties and Vickers microhardness showed a sharp increase at the beginning of the post-curing and then tended to increase gradually as the light intensity and post-curing time increased (p < 0.001). On the other hand, there was no significant difference between groups in the accuracy analysis of a 3D-printed three-unit bridge. These results indicate that the light intensity of the post-curing equipment influences the final mechanical properties of 3D-printed resin and that post-curing can be made more efficient by optimizing the light intensity and post-curing time.

9.
ACS Appl Mater Interfaces ; 13(25): 29392-29405, 2021 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-34137577

RESUMEN

Chemiluminescence immunoassays have been widely employed for diagnosing various diseases. However, because of the extremely low intensity chemiluminescence signals, highly sensitive transducers, such as photomultiplier tubes and image sensors with cooling devices, are required to overcome this drawback. In this study, a hypersensitive photosensor was developed based on cesium lead bromide (CsPbBr3) perovskite quantum dots (QDs) with sufficient high sensitivity for chemiluminescence immunoassays. First, CsPbBr3 QDs with a highly uniform size, that is, 5 nm, were synthesized under thermodynamic control to achieve a high size confinement effect. For the fabrication of the photosensor, MoS2 nanoflakes were used as an electron transfer layer and heat-treated at an optimum temperature. Additionally, a parylene-C film was used as a passivation layer to improve the physical stability and sensitivity of the photosensor. In particular, the trap states on the CsPbBr3 QDs were reduced by the passivation layer, and the sensitivity was increased. Finally, a photosensor based on CsPbBr3 QDs was employed in chemiluminescence immunoassays for the detection of human hepatitis B surface antigen, human immunodeficiency virus antibody, and alpha-fetoprotein (AFP, a cancer biomarker). When compared with the conventionally used equipment, the photosensor was determined to be feasible for application in chemiluminescence immunoassays.


Asunto(s)
Compuestos de Calcio/química , Inmunoensayo/métodos , Plomo/química , Mediciones Luminiscentes/métodos , Óxidos/química , Puntos Cuánticos/química , Titanio/química , Cesio/química , Anticuerpos Anti-VIH/análisis , Antígenos de Superficie de la Hepatitis B/análisis , Humanos , Polímeros/química , Xilenos/química
10.
ACS Appl Bio Mater ; 4(4): 3388-3397, 2021 04 19.
Artículo en Inglés | MEDLINE | ID: mdl-35014423

RESUMEN

To date, medical diagnosis of gout and pseudogout has been performed by observing the crystals in the joint fluid of patients under a polarized microscope. Conventional diagnostic methods using a polarized microscope have disadvantages, such as time-consuming analysis, a high false negative rate, and difficulty in distinguishing gout with monosodium urate (MSU) crystals and pseudogout with calcium pyrophosphate dihydrate (CPPD) crystals in synovial fluids. In this study, a chromogenic assay for the diagnosis of gout and pseudogout, without the requirement of a polarized microscope and trained experts, was proposed using Fv antibodies with specific binding activities to MSU and CPPD crystals. The IgG VH chain Fv library with randomized complementarity-determining region 3 (CDR3) region was expressed on the outer membrane of Escherichia coli using autodisplay technology. The target Fv antibodies with binding activity to MSU and CPPD crystals were screened from the autodisplayed Fv library on the E. coli outer membrane, and five clones were selected. On the basis of the binding properties of the screened Fv antibodies, peptides with the selected clone of amino acid sequences of the CDR3 region (15 residues) were chemically synthesized. The binding properties of the synthetic peptides with amino acid sequences of CDR3 regions from the selected clones were analyzed using fluorescence imaging and flow cytometry, and the affinity constants (Kd) of each peptide for binding to MSU and CPPD crystals were calculated by fitting based on the isotherm model. A chromogenic assay configuration for gout and pseudogout was developed using synthetic peptides. In this chromogenic assay, synthetic peptides labeled with biotin and streptavidin-horseradish peroxidase (HRP) complex were used, and crystal detection was possible using a chromogenic reaction between HRP and a chromogenic substrate (TMB). Finally, gout and pseudogout were diagnosed by detecting MSU and CPPD crystals in the synovial fluid in the concentration range of 0-300 µg/mL.


Asunto(s)
Artritis Gotosa/inmunología , Materiales Biocompatibles/química , Pirofosfato de Calcio/inmunología , Región Variable de Inmunoglobulina/inmunología , Ácido Úrico/inmunología , Sitios de Unión , Escherichia coli/química , Escherichia coli/inmunología , Humanos , Región Variable de Inmunoglobulina/biosíntesis , Ensayo de Materiales , Tamaño de la Partícula
11.
BMB Rep ; 54(6): 323-328, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34078528

RESUMEN

Periodontal diseases have been reported to have a multidirectional association with metabolic disorders. We sought to investigate the correlation between periodontitis and diabetes or fatty liver disease using HFD-fed obese mice inoculated with P. gingivalis. Body weight, alveolar bone loss, serological biochemistry, and glucose level were determined to evaluate the pathophysiology of periodontitis and diabetes. For the evaluation of fatty liver disease, hepatic nonalcoholic steatohepatitis (NASH) was assessed by scoring steatosis, inflammation, hepatocyte ballooning and the crucial signaling pathways involved in liver metabolism were analyzed. The C-reactive protein (CRP) level and NASH score in P. gingivalis-infected obese mice were significantly elevated. Particularly, the extensive lobular inflammation was observed in the liver of obese mice infected with P. gingivalis. Moreover, the expression of metabolic regulatory factors, including peroxisome proliferator-activated receptor γ (Pparγ) and the fatty acid transporter Cd36, was up-regulated in the liver of P. gingivalis-infected obese mice. However, inoculation of P. gingivalis had no significant influence on glucose homeostasis, insulin resistance, and hepatic mTOR/AMPK signaling. In conclusion, our results indicate that P. gingivalis can induce the progression of fatty liver disease in HFD-fed mice through the upregulation of CD36-PPARγ axis. [BMB Reports 2021; 54(6): 323-328].


Asunto(s)
Infecciones por Bacteroidaceae/complicaciones , Antígenos CD36/metabolismo , Inflamación/patología , Enfermedad del Hígado Graso no Alcohólico/patología , Obesidad/fisiopatología , PPAR gamma/metabolismo , Porphyromonas gingivalis/fisiología , Animales , Infecciones por Bacteroidaceae/microbiología , Antígenos CD36/genética , Dieta Alta en Grasa , Progresión de la Enfermedad , Inflamación/metabolismo , Inflamación/microbiología , Ratones , Ratones Endogámicos C57BL , Ratones Obesos , Enfermedad del Hígado Graso no Alcohólico/metabolismo , Enfermedad del Hígado Graso no Alcohólico/microbiología , PPAR gamma/genética
12.
ACS Appl Mater Interfaces ; 12(1): 135-150, 2020 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-31829016

RESUMEN

Multicompartmentalized nanostructures are of interest because they can provide unique physicochemical properties and multifunctionalities in each compartment. Furthermore, stimuli-responsive anisotropic nanostructures (ANPs) with distinct opposite charges would be useful for drug delivery systems because different drug release kinetics could be achieved from each compartment in response to both charge and stimuli. In this study, stimuli-responsive ANPs were formed via electrohydrodynamic cojetting of poly(N-isopropylacrylamide)-based copolymers with opposite charges. The positively charged compartment consisted of poly(N-isopropylacylamide-co-stearyl acrylate-co-allylamine) (poly(NIPAM-co-SA-co-AAm)) (i.e., PNSAAm) and poly(N-isopropylacylamide-co-stearyl acrylate-co-acrylic acid) (poly(NIPAM-co-SA-co-AAc)) (i.e., PNSAAc). The two distinct compartments of ANPs were physically cross-linked through hydrophobic interactions within the copolymers. Oppositely charged, small-molecule model drugs (fluorescein sodium salt and rhodamine 6G) were separately encapsulated within each compartment and released based on changes in noncovalent interactions and temperature. Furthermore, two different biomacromolecule drugs with opposite charges, bovine serum albumin and lysozyme (which were complexed with polysaccharides by hydrophobic ion pairing), were loaded within the ANPs. Electrostatic interactions between the encapsulated drugs and each ANP compartment controlled the rate of drug release from the ANPs. In addition, these ANPs showed a thermally induced actuation, leading to drug release at different rates due to the collapse of poly(NIPAM)-based copolymers under aqueous conditions. This work may be useful for decoupled drug release kinetics.


Asunto(s)
Resinas Acrílicas/química , Fluoresceína , Nanopartículas/química , Rodaminas , Anisotropía , Preparaciones de Acción Retardada/química , Preparaciones de Acción Retardada/farmacocinética , Preparaciones de Acción Retardada/farmacología , Fluoresceína/química , Fluoresceína/farmacocinética , Fluoresceína/farmacología , Células HeLa , Humanos , Micelas , Rodaminas/química , Rodaminas/farmacocinética , Rodaminas/farmacología
13.
Enzyme Microb Technol ; 133: 109457, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31874687

RESUMEN

Highly sensitive in situ-synthesized cadmium sulfide (CdS) nanowires (NWs) for the detection of chemiluminescence in immunoassays with a photoresist (PR) layer to stabilize the CdS NWs before and after coating with a parylene film were developed. The thickness of the PR layer was controlled by adjusting the viscosity of the PR solution used for spin-coating. PR2005 was the optimal PR for passivation of the NW surface. After the addition of a parylene coating on the CdS NWs, the photocurrent increased by as much as 50% over a broad range of light intensities, and the additional PR layer increased the photoresponse over the whole range of light intensities. When the photoresponses of the CdS NWs with and without the parylene film were compared after the addition of a PR layer, significant differences were observed in the photocurrent behavior after the incident light was turned off. For the CdS NWs with a parylene film and PR layer, the photocurrent reached the baseline within milliseconds of the incident light being turned off. However, the CdS NWs without a parylene film but with a PR layer required >60 s to reach the baseline level. This difference was due to the capacitance arising from the contact between the NWs. The in situ-synthesized CdS NW photosensor passivated by the parylene film and a PR layer was used in a chemiluminescence-based immunoassay. Finally, the detection of human immunodeficiency virus antibodies was demonstrated via a chemiluminescent enzyme-linked immunosorbent assay based on the CdS NW photosensor in comparison with the optical-density measurement for the chromogenic reaction of TMB(3,3',5,5'-Tetramethylbenzidine).


Asunto(s)
Compuestos de Cadmio/química , Inmunoensayo/instrumentación , Luminiscencia , Nanocables/química , Sulfuros/química , Polímeros/química , Xilenos/química
14.
J Am Soc Mass Spectrom ; 31(4): 917-926, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-32154716

RESUMEN

Recently, the parylene-matrix chip was developed for quantitative analysis of small molecules less than 1 kDa. In this study, MALDI-TOF MS based on the parylene-matrix chip was performed to clinically diagnose intrahepatic cholangiocarcinoma (IHCC) and colorectal cancer (CRC). The parylene-matrix chip was applied for the detection of small cancer biomarkers, including N-methyl-2-pyridone-5-carboxamide (2PY), glutamine, lysophosphatidylcholine (LPC) 16:0, and LPC 18:0. The feasibility of MALDI-TOF MS based on the parylene-matrix chip was confirmed via analysis of spot-to-spot and shot-to-shot reproducibility. Serum metabolite markers of IHCC, N-methyl-2-pyridone-5-carboxamide (2PY), and glutamine were quantified using MALDI-TOF MS based on the parylene-matrix chip. For clinical diagnosis of CRC, two water-insoluble (barely soluble) biomarkers, lysophosphatidylcholine (LPC) 16:0 and LPC 18:0, were quantified. Finally, glutamine and LPC 16:0 were simultaneously detected at a range of concentrations in sera from colon cancer patients using the parylene-matrix chip. Thus, this method yielded high-throughput detection of cancer biomarkers for the mixture samples of water-soluble analytes (2PY and glutamine) and water-insoluble analytes (LPC 16:0 and LPC 18:0).


Asunto(s)
Neoplasias de los Conductos Biliares/sangre , Biomarcadores de Tumor/sangre , Colangiocarcinoma/sangre , Neoplasias Colorrectales/sangre , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Neoplasias de los Conductos Biliares/diagnóstico , Colangiocarcinoma/diagnóstico , Neoplasias Colorrectales/diagnóstico , Diseño de Equipo , Glutamina/sangre , Humanos , Límite de Detección , Lisofosfatidilcolinas/sangre , Lisofosfatidilcolinas/química , Polímeros , Piridonas/sangre , Reproducibilidad de los Resultados , Solubilidad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Xilenos
15.
Enzyme Microb Technol ; 104: 56-68, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28648181

RESUMEN

A quantitative carbapenemase assay was developed using laser desorption/ionization mass spectrometry (LDI-MS) based on a parylene-matrix chip. As a first step, the reproducibility (spot-to-spot, shot-to-shot, and day-to-day) of LDI-MS based on a parylene-matrix chip and the quantification ranges for four carbapenem antibiotics (doripenem, ertapenem, imipenem, and meropenem) were determined. A carbapenem-susceptibility test was performed using the four carbapenems and 51 bacterial strains that displayed (1) carbapenem resistance with carbapenemase, (2) carbapenem resistance without carbapenemase, or (3) carbapenem susceptibility. The susceptibility test results showed that LDI-MS based on a parylene-matrix chip was more sensitive and selective for detecting the carbapenemase reaction than conventional MALDI-TOF MS based on a 2,5-dihydroxybenzoic acid matrix.


Asunto(s)
Proteínas Bacterianas/análisis , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , beta-Lactamasas/análisis , Bacterias/efectos de los fármacos , Bacterias/enzimología , Carbapenémicos/metabolismo , Carbapenémicos/farmacología , Gentisatos , Pruebas de Sensibilidad Microbiana , Polímeros , Reproducibilidad de los Resultados , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/estadística & datos numéricos , Xilenos , Resistencia betalactámica
16.
Enzyme Microb Technol ; 97: 90-96, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28010777

RESUMEN

Many kinds of susceptibility test for ß-lactam antibiotics have been used to determine the antibiotic resistance of bacterial strains. Here, a sensitive antibiotic susceptibility test was presented by using a specialized reaction tool for laser desorption/ionization time-of-flight mass spectrometry (LDI-TOF MS) based on parylene-matrix chip. The ß-lactamase assay was carried out in a specialized reaction tool by (1) concentrating the bacterial strain and (2) incubating the bacteria with penicillin-G. The parylene-matrix chip was produced by deposition of a partially porous parylene-N thin film on a dried organic matrix array, and the products of ß-lactamase reaction in the low range of mass-to-charge ratio (m/z<500) could be effectively analyzed by using a parylene-matrix chip. The sensing parameters were compared with conventional chromogenic antibiotic susceptibility test for ß-lactam antibiotics. Finally, LDI-TOF MS with a specialized reaction tool and parylene-matrix chip could achieve a limit of detection as low as 600 cells/spot for penicillin-G.


Asunto(s)
Antibacterianos/farmacología , Pruebas de Sensibilidad Microbiana/métodos , Inhibidores de beta-Lactamasas/farmacología , beta-Lactamasas/análisis , Biotecnología , Escherichia coli/efectos de los fármacos , Escherichia coli/enzimología , Límite de Detección , Pruebas de Sensibilidad Microbiana/instrumentación , Pruebas de Sensibilidad Microbiana/estadística & datos numéricos , Polímeros , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Xilenos , beta-Lactamas/farmacología
17.
Biosens Bioelectron ; 92: 221-228, 2017 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-28219030

RESUMEN

The direct in situ synthesis of cadmium sulfide (CdS) nanowires (NWs) was presented by direct synthesis of CdS NWs on the gold surface of an interdigitated electrode (IDE). In this work, we investigated the effect of a strong oxidant on the surfaces of the CdS NWs using X-ray photoelectron spectroscopy, transmission electron microscopy, and time-of-flight secondary ion mass spectrometry. We also fabricated a parylene-C film as a surface passivation layer for in situ-synthesized CdS NW photosensors and investigated the influence of the parylene-C passivation layer on the photoresponse during the coating of parylene-C under vacuum using a quartz crystal microbalance and a photoanalyzer. Finally, we used the in situ-synthesized CdS NW photosensor with the parylene-C passivation layer to detect the chemiluminescence of horseradish peroxidase and luminol and applied it to medical detection of carcinoembryonic antigen.


Asunto(s)
Técnicas Biosensibles/instrumentación , Compuestos de Cadmio/química , Antígeno Carcinoembrionario/sangre , Mediciones Luminiscentes/instrumentación , Nanocables/química , Polímeros/química , Sulfuros/química , Xilenos/química , Diseño de Equipo , Peroxidasa de Rábano Silvestre/química , Humanos , Inmunoensayo/instrumentación , Sustancias Luminiscentes/química , Luminol/química , Nanocables/ultraestructura , Oxidación-Reducción
18.
Anal Chim Acta ; 928: 39-48, 2016 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-27251855

RESUMEN

A band-type microelectrode was made using a parylene-N film as a passivation layer. A circular-type, mm-scale electrode with the same diameter as the band-type microelectrode was also made with an electrode area that was 5000 times larger than the band-type microelectrode. By comparing the amperometric signals of 3,5,3',5'-tetramethylbenzidine (TMB) samples at different optical density (OD) values, the band-type microelectrode was determined to be 9 times more sensitive than the circular-type electrode. The properties of the circular-type and the band-type electrodes (e.g., the shape of their cyclic voltammograms, the type of diffusion layer used, and the diffusion layer thickness per unit electrode area) were characterized according to their electrode area using the COMSOL Multiphysics software. From these simulations, the band-type electrode was estimated to have the conventional microelectrode properties, even when the electrode area was 100 times larger than a conventional circular-type electrode. These results show that both the geometry and the area of an electrode can influence the properties of the electrode. Finally, amperometric analysis based on a band-type electrode was applied to commercial ELISA kits to analyze human hepatitis B surface antigen (hHBsAg) and human immunodeficiency virus (HIV) antibodies.


Asunto(s)
Electroquímica/instrumentación , Inmunoensayo/instrumentación , Bencidinas/química , Difusión , Diseño de Equipo , Microelectrodos , Polímeros/química , Xilenos/química
19.
Biosens Bioelectron ; 71: 306-312, 2015 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-25919811

RESUMEN

This work presented a highly sensitive bacterial antibiotic susceptibility test through ß-lactamase assay using Parylene-matrix chip. ß-lactamases (EC 3.5.2.6) are an important family of enzymes that confer resistance to ß-lactam antibiotics by catalyzing the hydrolysis of these antibiotics. Here we present a highly sensitive assay to quantitate ß-lactamase-mediated hydrolysis of penicillin into penicilloic acid. Typically, MALDI-TOF mass spectrometry has been used to quantitate low molecular weight analytes and to discriminate them from noise peaks of matrix fragments that occur at low m/z ratios (m/z<500). The ß-lactamase assay for the Escherichia coli antibiotic susceptibility test was carried out using Parylene-matrix chip and MALDI-TOF mass spectrometry. The Parylene-matrix chip was successfully used to quantitate penicillin (m/z: [PEN+H](+)=335.1 and [PEN+Na](+)=357.8) and penicilloic acid (m/z: [PA+H](+)=353.1) in a ß-lactamase assay with minimal interference of low molecular weight noise peaks. The ß-lactamase assay was carried out with an antibiotic-resistant E. coli strain and an antibiotic-susceptible E. coli strain, revealing that the minimum number of E. coli cells required to screen for antibiotic resistance was 1000 cells for the MALDI-TOF mass spectrometry/Parylene-matrix chip assay.


Asunto(s)
Escherichia coli/efectos de los fármacos , Escherichia coli/enzimología , Pruebas de Sensibilidad Microbiana/instrumentación , Penicilinas/farmacología , Polímeros/química , Xilenos/química , beta-Lactamasas/metabolismo , Bioensayo/instrumentación , Farmacorresistencia Bacteriana , Diseño de Equipo , Análisis de Falla de Equipo , Análisis por Micromatrices/instrumentación , Ácido Penicilánico/análogos & derivados , Ácido Penicilánico/análisis , Ácido Penicilánico/metabolismo , Penicilinas/farmacocinética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , beta-Lactamasas/análisis
20.
Anal Chim Acta ; 853: 360-367, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25467480

RESUMEN

A lateral flow immunoassay (LF-immunoassay) with an enhanced sensitivity and thermostability was developed by using Pt nanoparticles with a peroxidase activity. The Pt nanoparticles were synthesized by citrate reduction method, and the peroxidase activity of Pt nanoparticles was optimized by adjusting reaction conditions. The peroxidase activity was estimated by using Michaelis-Menten kinetics model with TMB as a chromogenic substrate. The kinetics parameters of KM and Vmax were calculated and compared with horseradish peroxidase (HRP). The thermal stability of the Pt nanoparticles was compared with horseradish peroxidase (HRP) according to the storage temperature and long-term storage period. The feasibility of lateral flow immunoassay with a chemiluminescent signal band was demonstrated by the detection of human chorionic gonadotropin (hCG) as a model analyte, and the sensitivity was determined to be improved by as much as 1000-fold compared to the conventional rapid test based on colored gold-colloids.


Asunto(s)
Materiales Biomiméticos/química , Peroxidasa de Rábano Silvestre/metabolismo , Inmunoensayo/métodos , Mediciones Luminiscentes , Nanopartículas del Metal/química , Platino (Metal)/química , Celulosa/química , Gonadotropina Coriónica/análisis , Citratos/química , Estudios de Factibilidad , Humanos , Concentración de Iones de Hidrógeno , Cinética , Membranas Artificiales , Temperatura
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA