Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 16(6): 263-272, 2015 11 08.
Artículo en Inglés | MEDLINE | ID: mdl-26699582

RESUMEN

The American Association of Physicists in Medicine Task Group 119 instructed institutions to use a low-dose threshold of 10% or a region of interest determined by the jaw setting when they collected gamma analysis quality assurance (QA) data for the planar dose distribution. However, there are no clinical data to quantitatively demonstrate the impact of the low-dose threshold on the gamma index. Therefore, we performed a gamma analysis with various low-dose thresholds in the range of 0% to 15% according to both global and local normalization and different acceptance criteria (3%/3 mm, 2%/2 mm, and 1%/1 mm). A total of 30 treatment plans--10 head and neck, 10 brain, and 10 prostate cancer cases--were randomly selected from the Varian Eclipse treatment planning system (TPS). For the gamma analysis, a calculated portal image was acquired through a portal dose calculation algorithm in the Eclipse TPS, and a measured portal image was obtained using an electronic portal-imaging device. Then, the gamma analysis was performed using the Portal Dosimetry software (Varian Medical Systems, Palo Alto, CA). The gamma passing rate (%GP) for the global normalization decreased as the low-dose threshold increased, and all low-dose thresholds led to %GP values above 95% for both the 3%/3 mm and 2%/2 mm criteria. However, for the local normalization, %GP for a low-dose threshold of 10% was 7.47%, 10.23%, and 6.71% greater than the low-dose threshold of 0% for head and neck, brain, and prostate for the 3%/3 mm criteria, respectively. The results indicate that applying the low-dose threshold to global normalization does not have a critical impact on patient-specific QA results. However, in the local normalization, the low-dose threshold level should be carefully selected because the excluded low-dose points could cause the average %GP to increase rapidly.


Asunto(s)
Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Neoplasias Encefálicas/radioterapia , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Neoplasias de la Próstata/radioterapia , Garantía de la Calidad de Atención de Salud , Radiometría/métodos , Radiometría/estadística & datos numéricos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Radioterapia de Intensidad Modulada/normas , Radioterapia de Intensidad Modulada/estadística & datos numéricos
2.
Int J Nanomedicine ; 18: 4365-4379, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37545871

RESUMEN

Purpose: To evaluate the remineralization effect of calcium phosphate ion clusters (CPICs) on demineralized enamel surfaces and their effects on bracket shear bond strength. Patients and Methods: Extracted premolars were prepared in resin blocks. The samples in the form of resin blocks were divided into five experimental groups: control group, demineralized group, and groups of CPIC solution treatment for 30, 60, and 90s. The specimens were examined using scanning electron microscopy (SEM), energy-dispersive spectroscopy (EDX), microhardness testing, micro-computed tomography (micro-CT) assessment, shear bond strength (SBS) test, and adhesive remnant index (ARI) score. Results: The SEM images revealed epitaxial growth of enamel and a decrease in the thickness of the demineralized enamel layer when treated with CPIC solution. The EDX analysis revealed an increase in the Ca/P ratio in the CPIC-treated groups. The microhardness value significantly increased when treated with CPICs; however, it showed a lower value than that of the sound enamel groups. As a result of the micro-CT test, radiolucency decreased gradually as the CPIC treatment time increased. The SBS test and ARI score results showed an improvement in bonding stability after treatment with CPICs. Conclusion: We demonstrated an enamel biomodification approach using CPIC solution treatment, which is a promising strategy for enamel remineralization. Specifically, remineralization of demineralized enamel improves the orthodontic bracket SBS.


Asunto(s)
Biomimética , Recubrimiento Dental Adhesivo , Microtomografía por Rayos X , Fosfatos de Calcio , Resistencia al Corte , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA