Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Molecules ; 29(14)2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39065018

RESUMEN

Recently, hexahydrocannabinol (HHC) was posed under strict control in Europe due to the increasing HHC-containing material seizures. The lack of analytical methods in clinical laboratories to detect HHC and its metabolites in biological matrices may result in related intoxication underreporting. We developed and validated a comprehensive GC-MS/MS method to quantify 9(R)-HHC, 9(S)-HHC, 9αOH-HHC, 9ßOH-HHC, 8(R)OH-9(R)-HHC, 8(S)OH-9(S)HHC, 11OH-9(R)HHC, 11OH-9(S)HHC, 11nor-carboxy-9(R)-HHC, and 11nor-carboxy-9(S)-HHC in whole blood, urine, and oral fluid. A novel QuEChERS extraction protocol was optimized selecting the best extraction conditions suitable for all the three matrices. Urine and blood were incubated with ß-glucuronidase at 60 °C for 2 h. QuEChERS extraction was developed assessing different ratios of Na2SO4:NaCl (4:1, 2:1, 1:1, w/w) to be added to 200 µL of any matrix added with acetonitrile. The chromatographic separation was achieved on a 7890B GC with an HP-5ms column, (30 m, 0.25 mm × 0.25 µm) in 12.50 min. The analytes were detected with a triple-quadrupole mass spectrometer in the MRM mode. The method was fully validated following OSAC guidelines. The method showed good validation parameters in all the matrices. The method was applied to ten real samples of whole blood (n = 4), urine (n = 3), and oral fluid (n = 3). 9(R)-HHC was the prevalent epimer in all the samples (9(R)/9(S) = 2.26). As reported, hydroxylated metabolites are proposed as urinary biomarkers, while carboxylated metabolites are hematic biomarkers. Furthermore, 8(R)OH-9(R)HHC was confirmed as the most abundant metabolite in all urine samples.


Asunto(s)
Dronabinol , Cromatografía de Gases y Espectrometría de Masas , Espectrometría de Masas en Tándem , Humanos , Cromatografía de Gases y Espectrometría de Masas/métodos , Espectrometría de Masas en Tándem/métodos , Dronabinol/orina , Dronabinol/sangre , Dronabinol/análogos & derivados , Saliva/química , Saliva/metabolismo , Reproducibilidad de los Resultados
2.
J Pharm Biomed Anal ; 248: 116293, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38901154

RESUMEN

A method of analysis was developed for the simultaneous chemo- and enantioseparation of 2-, 3-, and 4-chloromethcathinones by high-performance liquid chromatography tandem mass-spectrometry. The fast method enables the reliable identification of positional isomers of chloromethcathinones in biological samples. In addition, the same method can be used for the enantioselective quantitative determination of one of these compounds and its major phase-1 metabolites in biological fluids. The developed method was applied to oral fluid samples collected by police during routine random traffic control in Belgium from January to November, 2023. It was found that 3-CMC was more frequently abused compared to 4-CMC. Although some differences were observed between the concentrations of enantiomers in OF, most likely the drugs were abused in the racemic form. No abuse of 2-CMC was detected at the timepoint of sample collection.


Asunto(s)
Saliva , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Humanos , Saliva/química , Estereoisomerismo , Propiofenonas/química , Propiofenonas/análisis , Detección de Abuso de Sustancias/métodos , Bélgica
3.
J Chromatogr A ; 1624: 461218, 2020 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-32540066

RESUMEN

In this study, amylose- and cellulose-phenylcarbamate-based chiral columns with different chiral-selector (CS) chemistries were compared to each other for the separation of enantiomers of basic chiral analytes in acetonitrile and aqueous-acetonitrile mobile phases in HPLC. For two chemistries the amylose-based columns with coated and immobilized CSs were also compared. The comparison of CSs containing only electron-donating or electron-withdrawing substituents with those containing both electron-donating and electron-withdrawing substituents showed opposite results for the studied set of chiral analytes in the case of amylose and cellulose derivatives. Along with the chemistry of CS the focus was on the behavior of polysaccharide phenylcarbamates in acetonitrile versus aqueous acetonitrile as eluents. In agreement with earlier results, it was found that in contrast to the commonly accepted view, polysaccharide phenylcarbamates do not behave as typical reversed-phase materials for basic analytes either. In the range of water content in the mobile phase of up to 20-30% v/v the behavior of these CSs is similar to hydrophilic interaction liquid chromatography (HILIC)-type adsorbents. This means that with increasing water content in the mobile phase up to 20-30% v/v, the retention of analytes mostly decreases. The important finding of this study is that the separation efficiency improves for most analytes when switching from pure acetonitrile to aqueous acetonitrile. Therefore, in spite of reduced retention, the separation of enantiomers improves and thus, the HILIC-range of mobile phase composition, offering shorter analysis time and better peak resolution, is advantageous over pure polar-organic solvent mode. Interesting examples of enantiomer elution order (EEO) reversal were observed for some analytes based on the content of water in the mobile phase on Lux Cellulose-1 and Lux Amylose-2 columns.


Asunto(s)
Amilosa/química , Celulosa/química , Cromatografía Líquida de Alta Presión/métodos , Preparaciones Farmacéuticas/aislamiento & purificación , Fenilcarbamatos/química , Acetonitrilos/química , Electrones , Etanolaminas/análisis , Etanolaminas/aislamiento & purificación , Preparaciones Farmacéuticas/análisis , Propanolaminas/análisis , Propanolaminas/aislamiento & purificación , Propranolol/análisis , Propranolol/aislamiento & purificación , Estereoisomerismo , Agua/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA