Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Hong Kong Med J ; 23(4): 333-9, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28278491

RESUMEN

INTRODUCTION: The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing. METHODS: A retrospective study was conducted to review the results after a minimum of 12.4 years of 207 consecutive total hip arthroplasties in 185 patients in Peking University People's Hospital in China using the Zweymüller SL-Plus stem in combination with the Bicon-Plus threaded cup and ceramic-on-polyethylene bearing between October 1994 and April 2000. RESULTS: During the study period, two patients (2 hips) died and 25 patients (28 hips) were lost to follow-up. Two hips were revised for aseptic loosening of the Bicon-Plus cup. The mean clinical and radiological follow-up was 14.1 years (range, 12.4-16.5 years) for the remaining 156 patients (175 hips). The mean (standard deviation) Harris Hip score for the 175 hips increased significantly from 39.3 (3.8) preoperatively to 94.1 (2.5) postoperatively at a mean follow-up of 14.1 years (P<0.05). Focal osteolysis was observed in seven (4.0%) of 175 stems and three (1.7%) of 175 cups. The Kaplan-Meier survival with revision for any reason as the end-point was 99.03% (95% confidence interval, 95%-100%). CONCLUSIONS: The high survival rate of the cementless Zweymüller-Plus system with ceramic-on-polyethylene bearing at mid-term follow-up makes this total hip arthroplasty system reliable for patients with various hip joint diseases.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Cerámica , Prótesis de Cadera/estadística & datos numéricos , Artropatías/cirugía , Polietileno , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/métodos , China , Femenino , Estudios de Seguimiento , Articulación de la Cadera/fisiopatología , Humanos , Artropatías/fisiopatología , Perdida de Seguimiento , Masculino , Persona de Mediana Edad , Periodo Posoperatorio , Diseño de Prótesis , Falla de Prótesis , Rango del Movimiento Articular , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA