Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Vasc Interv Radiol ; 20(12): 1608-16, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19944986

RESUMEN

PURPOSE: In part 1 of the present study, the authors demonstrated that coronary paclitaxel uptake from drug eluting stents (DESs) was not dependent on exposure time and dose. In this second part, the effect of the different paclitaxel dose densities on long-term biologic behavior was evaluated. MATERIALS AND METHODS: In 40 minipigs, (with 4- and 12-week follow-up), identical stents with the same three paclitaxel dose densities as in part 1 were implanted in the right coronary artery. Minipigs implanted with Polyzene-F nanocoated stents served as the control group. Quantitative angiography measuring average luminal diameter (from three in-stent reference points), minimal luminal diameter (from the point of maximum in-stent stenosis), average late loss, maximum late loss, and binary stenosis rate was performed, as was microscopy to determine neointimal thickening, injury score, and inflammation. RESULTS: All three DESs were associated with a high average late loss, binary stenosis rate, and neointimal thickening, without significant differences. Drug-free stents had significantly less late in-stent stenosis: there was an average late loss of 0.3 mm +/- 0.3 in drug-free stents versus 0.8 mm +/- 0.2 in intermediate-dose stents and 1.5 mm +/- 0.6 in high-dose stents (P = .04). DES-associated inflammation was high in all DESs and six times higher as in the drug-free stents (Kornowski scores of 0.2 +/- 0.1 in drug-free stents, 1.3 +/- 0.9 in low-dose stents, 1.7 +/- 0.8 in intermediate-dose stents, and 1.3 +/- 1.0 in high-dose stents; P = .04). It worsened with time in all DESs, as did late in-stent stenosis. CONCLUSIONS: The extensive and long-term retention of paclitaxel even in a low-dose formulation, at least according to the present labeling of DESs, might be associated with negative long-term results with regard to inflammation and late in-stent stenosis.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/toxicidad , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/inducido químicamente , Vasos Coronarios/efectos de los fármacos , Stents Liberadores de Fármacos , Inflamación/inducido químicamente , Paclitaxel/toxicidad , Angioplastia Coronaria con Balón/efectos adversos , Animales , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/patología , Vasos Coronarios/patología , Relación Dosis-Respuesta a Droga , Femenino , Inflamación/diagnóstico por imagen , Inflamación/patología , Modelos Animales , Paclitaxel/administración & dosificación , Diseño de Prótesis , Falla de Prótesis , Porcinos , Porcinos Enanos , Factores de Tiempo
2.
J Vasc Interv Radiol ; 20(7): 927-35, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-19497761

RESUMEN

PURPOSE: To compare outcomes with a thermoplastic polyurethane (TPU)-covered self-expanding nitinol stent-graft (TPU graft) with those of a bare self-expanding nitinol stent in a porcine model. MATERIALS AND METHODS: Fourteen TPU grafts and 14 commercially available bare nitinol stents were implanted, one each, in the iliac arteries of 14 minipigs. Follow-up was performed at 1 week (six animals), 4 weeks (four animals), and 12 weeks (four animals). The primary study endpoint was in-stent stenosis assessed with quantitative angiography and microscopy. Secondary endpoints were injury, inflammation, and endothelialization. RESULTS: After 1 week, the maximum percentage luminal loss was significantly greater in TPU grafts (average, 16.2%; range, 0.0%-35.8%) than in bare nitinol stents (8.2%; 0.0%-17.3%) (P = .04). Three of the four TPU grafts were occluded after 4 weeks, and all four TPU grafts were occluded after 12 weeks. Binary stenosis was seen in three of four bare nitinol stents after both 4 and 12 weeks. At 4-week follow-up, the average percentage luminal loss was significantly greater in TPU grafts (85.2%; 40.8%-100%) than in bare nitinol stents (49.5%; 37.9%-62.4%) (P = .003). The difference in neointimal height and percentage average stenosis between TPU grafts (1,028.7 microm and 68.4%) and bare nitinol stents (1,033.6 microm [918.0-1,118.40 microm] and 68.1% [60.44%-71.99%]) was not statistically significant. After 12 weeks, the average percentage luminal loss was 100% in TPU grafts due to occlusion of all stent-grafts and 24.9% (8.0%-63.9%) in bare nitinol stents (P = .011). CONCLUSIONS: TPU grafts failed to provide improved patency compared with the bare nitinol stents because of excessive neointimal growth and subsequent occlusion. In addition, the bare nitinol stents showed considerable in-stent stenosis at angiography and microscopy.


Asunto(s)
Prótesis Vascular/efectos adversos , Modelos Animales de Enfermedad , Oclusión de Injerto Vascular/etiología , Arteria Ilíaca/cirugía , Poliuretanos/efectos adversos , Stents/efectos adversos , Aleaciones/efectos adversos , Aleaciones/química , Animales , Materiales Biocompatibles Revestidos/química , Diseño de Equipo , Análisis de Falla de Equipo , Oclusión de Injerto Vascular/diagnóstico , Calor , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Plásticos/efectos adversos , Plásticos/química , Poliuretanos/química , Porosidad , Radiografía , Porcinos
3.
Invest Radiol ; 42(5): 303-11, 2007 May.
Artículo en Inglés | MEDLINE | ID: mdl-17414526

RESUMEN

OBJECTIVES: Previous experimental studies have demonstrated that poly[bis(trifluoroethoxy)phosphazene] (PTFEP) nanocoated stents have antithrombotic characteristics, reduce in-stent stenosis, prevent wall inflammation, and do not hamper endothelialization. This study was designed to validate these findings in a porcine coronary artery model. MATERIALS AND METHODS: PTFEP-coated (n = 15) and bare stents (n= 13) were implanted in coronary arteries of 18 mini-pigs (4- and 12-week follow-up). Primary study endpoints were thrombogenicity and in-stent stenosis, secondary study endpoints were inflammatory response and re-endothelialization evaluated by quantitative angiography and light microscopy. RESULTS: No thrombus deposition occurred on any stent. At 4 weeks follow-up, the bare stents (n = 4) had a significantly smaller neointimal area (1.93 vs. 3.20 mm(2), P = 0.009). At 12 weeks, PTFEP-coated stents (n = 11) had significantly superior results in almost all parameters: neointimal area (2.25 vs. 2.65 mm(2), P = 0.034), neointimal height (204.46 vs. 299.41 microm, P = 0.048), percentage stenosis (38.25 vs. 50.42%, P = 0.019), and inflammation score (0.12 vs. 0.30, P = 0.029). Complete re-endothelialization was seen in both stent types at both intervals. CONCLUSION: At long-term follow-up, the superior results of PTFEP-coated stents were characterized by a noteworthy reduction of neointimal growth and inflammatory response.


Asunto(s)
Materiales Biocompatibles Revestidos , Vasos Coronarios , Compuestos Organofosforados , Polímeros , Stents , Trombosis/prevención & control , Animales , Angiografía Coronaria , Vasos Coronarios/patología , Modelos Animales , Diseño de Prótesis , Acero Inoxidable , Porcinos , Porcinos Enanos , Túnica Íntima/patología , Grado de Desobstrucción Vascular
4.
Tissue Eng Part A ; 17(17-18): 2187-97, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21529247

RESUMEN

PURPOSE: The purpose of this work was to evaluate the potential of substituting autogenous bone (AB) by bone marrow aspirate concentrate (BMAC). Both AB and BMAC were tested in combination with a bovine bone mineral (BBM) for their ability of new bone formation (NBF) in a multicentric, randomized, controlled, clinical and histological noninferiority trial. MATERIALS AND METHODS: Forty-five severely atrophied maxillary sinus from 26 patients were evaluated in a partial cross-over design. As test arm, 34 sinus of 25 patients were augmented with BBM and BMAC containing mesenchymal stem cells. Eleven control sinus from 11 patients were augmented with a mixture of 70% BBM and 30% AB. Biopsies were obtained after a 3-4-month healing period at time of implant placement and histomorphometrically analyzed for NBF. RESULTS: NBF was 14.3%±1.8% for the control and nonsignificantly lower (12.6%±1.7%) for the test (90% confidence interval: -4.6 to 1.2). Values for BBM (31.3%±2.7%) were significantly higher for the test compared with control (19.3%±2.5%) (p<0.0001). Nonmineralized tissue was lower by 3.3% in the test compared with control (57.6%; p=0.137). CONCLUSIONS: NBF after 3-4 months is equivalent in sinus, augmented with BMAC and BBM or a mixture of AB and BBM. This technique could be an alternative for using autografts to stimulate bone formation.


Asunto(s)
Médula Ósea/metabolismo , Sustitutos de Huesos/uso terapéutico , Trasplante Óseo/métodos , Elevación del Piso del Seno Maxilar/métodos , Adulto , Anciano , Animales , Regeneración Ósea/fisiología , Bovinos , Femenino , Humanos , Masculino , Seno Maxilar/cirugía , Persona de Mediana Edad , Osteogénesis/fisiología , Método Simple Ciego
5.
J Vasc Interv Radiol ; 19(3): 427-37, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18295704

RESUMEN

PURPOSE: It is hypothesized that the inorganic polymer poly[bis(trifluoroethoxy)phosphazene] (PTFEP) reduces stent-associated thrombosis, in-stent stenosis, and inflammatory response and stimulates reendothelialization in a porcine model. MATERIALS AND METHODS: PTFEP-nanocoated and bare stainless-steel stents (316 L) were implanted bilaterally in renal and iliac arteries of 16 minipigs (1, 4, and 12 weeks follow-up durations). Primary study endpoints were thrombogenicity determined by filling defects on angiography and in-stent stenosis assessed by lumen loss on quantitative angiography (ie, percentage stenosis) and light microscopy (ie, neointimal thickness, neointimal area, area stenosis). Secondary endpoints were inflammatory response and reendothelialization evaluated by light microscopy and scanning electron microscopy (SEM), respectively. RESULTS: Stent placement was successful in 32 renal and 26 iliac arteries. At follow-up, there were no thrombus depositions on PTFEP-coated renal and iliac stents. Thrombus depositions were found on two of six bare metal iliac stents after 4 weeks (P = .0651). PTFEP-coated stents showed a trend toward reduced in-stent stenosis in all renal and iliac arteries at all intervals: in iliac stents, neointimal area was significantly smaller in coated stents than in bare metal stents after 1 week and 4 weeks (P = .03 and P = .001, respectively). In renal arteries, inflammation scores indicated lower inflammatory response in PTFEP-coated stents than in bare metal stents after 1 week (P = .01). After 1 week, coated and bare metal stents exhibited complete reendothelialization on SEM. CONCLUSIONS: PTFEP-coated stents exhibited reduced thrombus deposition and a trend toward less in-stent stenosis and inflammatory response than bare metal stents.


Asunto(s)
Inflamación/prevención & control , Compuestos Organofosforados , Polímeros , Stents , Trombosis/prevención & control , Angiografía , Animales , Materiales Biocompatibles Revestidos , Epitelio/fisiología , Femenino , Arteria Ilíaca , Masculino , Stents/efectos adversos , Porcinos , Porcinos Enanos , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA