Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Environ Sci Technol ; 57(29): 10754-10762, 2023 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-37428629

RESUMEN

Plastic has been demonstrated to release nanoplastics (NPs) into the atmosphere under sunlight irradiation, posing a continuous health risk to the respiratory system. However, due to lack of reliable quantification methods, the occurrence and distribution of NPs in the atmosphere remain unclear. Polystyrene (PS) micro- and nanoplastics (MNPs) represent a crucial component of atmospheric MNPs. In this study, we proposed a simple and robust method for determining the concentration of atmospheric PS NPs using pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS). Following active sampling, the filter membrane is directly ground and introduced into the Py-GC/MS system to quantify PS NPs. The proposed method demonstrates excellent reproducibility and high sensitivity, with a detection limit as low as down to 15 pg/m3 for PS NPs. By using this method, the occurrence of PS NPs in both indoor and outdoor atmospheres has been confirmed. Furthermore, the results showed that the abundance of outdoor PS NPs was significantly higher than that of indoor samples, and there was no significant difference in NP vertical distribution within a height of 28.6 m. This method can be applied for the routine monitoring of atmospheric PS NPs and for evaluating their risk to human health.


Asunto(s)
Nanopartículas , Contaminantes Químicos del Agua , Humanos , Poliestirenos , Microplásticos , Cromatografía de Gases y Espectrometría de Masas , Pirólisis , Reproducibilidad de los Resultados , Contaminantes Químicos del Agua/análisis , Nanopartículas/química
2.
Anal Chem ; 93(10): 4559-4566, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33646744

RESUMEN

Respective detection of microplastics (MPs) and nanoplastics (NPs) is of great importance for their different environmental behaviors and toxicities. Using spherical polystyrene (PS) and poly(methyl methacrylate) (PMMA) plastics as models, the efficiency for sequential isolation of MPs and NPs by membrane filtration and cloud-point extraction was evaluated. After filtering through a glass membrane (1 µm pore size), over 90.7% of MPs were trapped on the membrane, whereas above 93.0% of NPs remained in the filtrate. The collected MPs together with the glass membrane were frozen in liquid nitrogen, ground, and suspended in water (1 mL) and subjected to pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS) determination. The NPs in the filtrate were concentrated by cloud-point extraction, heated at 190 °C to degrade the extractant, and then determined by Py-GC/MS. For MPs and NPs spiked in pure water, the method detection limits are in the range of 0.05-1.9 µg/L. The proposed method is applied to analyze four real water samples, with the detection of 1.6-7.6 µg/L PS MPs and 0.6 µg/L PMMA MPs in three samples, and spiked recoveries of 75.0-102% for MPs and 67.8-87.2% for NPs. Our method offers a novel sample pretreatment approach for the respective determination of MPs and NPs.


Asunto(s)
Microplásticos , Contaminantes Químicos del Agua , Plásticos , Poliestirenos/análisis , Pirólisis , Contaminantes Químicos del Agua/análisis
3.
Environ Sci Technol ; 51(23): 13816-13824, 2017 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-29121473

RESUMEN

Efficient separation and preconcentration of trace nanoparticulate silver (NAg) from large-volume environmental waters is a prerequisite for reliable analysis and therefore understanding the environmental processes of silver nanoparticles (AgNPs). Herein, we report the novel use of polyvinylidene fluoride (PVDF) filter membrane for disk-based solid phase extraction (SPE) of NAg in 1 L of water samples with the disk-based SPE system, which consists of a syringe pump and a syringe filter holder to embed the filter membrane. While the PVDF membrane can selectively adsorb NAg in the presence of Ag+, aqueous solution of 2% (m/v) FL-70 is found to efficiently elute NAg. Analysis of NAg is performed following optimization of filter membrane and elution conditions with an enrichment factor of 1000. Additionally, transmission electron microscopy (TEM), UV-vis spectroscopy, and size-exclusion chromatography coupled with ICP-MS (SEC-ICP-MS) analysis showed that the extraction gives rise to no change in NAg size or shape, making this method attractive for practical applications. Furthermore, feasibility of the protocol is verified by applying it to extract NAg in four real waters with recoveries of 62.2-80.2% at 0.056-0.58 µg/L spiked levels. This work will facilitate robust studies of trace NAg transformation and their hazard assessments in the environment.


Asunto(s)
Nanopartículas del Metal , Polivinilos , Contaminantes Químicos del Agua , Plata , Extracción en Fase Sólida
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA