Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 237-244, 2024 May 30.
Artículo en Zh | MEDLINE | ID: mdl-38863087

RESUMEN

Additive manufacturing (3D printing) technology aligns with the direction of precision and customization in future medicine, presenting a significant opportunity for innovative development in high-end medical devices. Currently, research and industrialization of 3D printed medical devices mainly focus on nondegradable implants and degradable implants. Primary areas including metallic orthopaedic implants, polyether-ether-ketone (PEEK) bone implants, and biodegradable implants have been developed for clinical and industrial application. Recent research achievements in these areas are reviewed, with a discussion on the additive manufacturing technologies and applications for customized implants. Challenges faced by different types of implants are analyzed from technological, application, and regulatory perspectives. Furthermore, prospects and suggestions for future development are outlined.


Asunto(s)
Impresión Tridimensional , Prótesis e Implantes , Benzofenonas , Polímeros , Humanos , Cetonas , Diseño de Prótesis , Materiales Biocompatibles , Polietilenglicoles , Implantes Absorbibles
2.
J Craniofac Surg ; 33(8): e877-e880, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35968952

RESUMEN

The paranasal area is closely associated with midfacial esthetics. However, there is no special technique available to achieve ideal esthetics paranasal restoration. The present study aims to apply the 3D printed PolyEtherEtherKetone (PEEK) implants as an innovative solution for esthetic paranasal reconstruction. On the basis of the CT scan, the patient-specific PEEK implant and a surgical guiding plate were manufactured aided by a computer. Preoperative and postoperative CBCT data were utilized to evaluate esthetic outcomes. The average follow-up period was 13 months. All patients' wounds healed by first intention. The statistical analysis of preoperative and postoperative esthetic indices revealed light levels of postoperative paranasal depression ( P <0.001) and the wrinkle severity rating scale for nasolabial folds ( P <0.001). Moreover, the nasolabial angle increased ( P <0.05). The established 3D-printing PEEK implanted prosthesis can individually correct the depressed deformity of the paranasal region, and achieve favorable clinical esthetic outcomes.


Asunto(s)
Implantes Dentales , Procedimientos de Cirugía Plástica , Humanos , Diseño Asistido por Computadora , Procedimientos de Cirugía Plástica/métodos , Estética Dental , Cetonas , Polietilenglicoles
3.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 32(1): 77-81, 2015 Feb.
Artículo en Zh | MEDLINE | ID: mdl-25997270

RESUMEN

Focusing on the poor mechanical strength of porous bioceramics bone scaffold, and taking into account of the good mechanical properties of biodegradable magnesium alloy, we proposed a novel method to fabricate magnesium alloy/bioceramics composite bone scaffold with stereolithography double channels. Firstly, a scaffold structure without mutually connected double channels was designed. Then, an optimized bioceramics scaffold was fabricated according to stereolithography and gel-casing. Molten AZ31 magnesium alloy was perfused into the secondary channel of scaffold by low-pressure casting, and magnesium alloy/bioceramics composite bone scaffold was obtained when magnesium alloy was solidified. The compression test showed that the strength of bioceramics scaffold with only one channel and without magnesium alloy was (9.76 ± 0.64) MPa, while the strength of magnesium alloy/bioceramics composite scaffold with double channels was (17.25 ± 0.88) MPa. It can be concluded that the magnesium alloy/bioceramics composite is obviously able to improve the scaffold strength.


Asunto(s)
Huesos , Cerámica , Ensayo de Materiales , Andamios del Tejido , Aleaciones , Fenómenos Biomecánicos , Humanos , Magnesio , Porosidad
4.
Biomater Adv ; 161: 213888, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38759305

RESUMEN

Short carbon fiber (SCF) reinforced polymer composites are expected to possess outstanding biotribological and mechanical properties in certain direction, while the non-oriented SCF weakens its reinforcing effect in the matrix. In this work, high-oriented SCF was achieved during nozzle extrusion, and then SCF reinforced polyether-ether-ketone (PEEK) composites were fabricated by fused deposition modeling (FDM). The concrete orientation process of SCF was theoretically simulated, and significant shear stress difference was generated at both ends of SCF. As a result, the SCF was distributed in the matrix in a hierarchical structure, containing surface layer I, II and core layer. Moreover, the SCF was oriented highly along the printing direction and demonstrated a more competitive orientation distribution compared to other studies. The SCF/PEEK composites showed a considerable improvement in wear resistance by 44 % due to self-lubricating and load-bearing capability of SCF. Besides, it demonstrated enhancements in Brinell hardness, compressive and impact strength by 48.52 %, 16.42 % and 53.64 %, respectively. In addition, SCF/PEEK composites also showed good cytocompatibility. The findings gained herein are useful for developing the high-oriented SCF reinforced polymer composites with superior biotribological and mechanical properties for artificial joints.


Asunto(s)
Benzofenonas , Fibra de Carbono , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Impresión Tridimensional , Fibra de Carbono/química , Polímeros/química , Polietilenglicoles/química , Cetonas/química , Ensayo de Materiales/métodos , Materiales Biocompatibles/química , Prótesis Articulares , Humanos
5.
Nat Commun ; 14(1): 3869, 2023 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-37391425

RESUMEN

Owing to their high deformation ability, 4D printed structures have various applications in origami structures, soft robotics and deployable mechanisms. As a material with programmable molecular chain orientation, liquid crystal elastomer is expected to produce the freestanding, bearable and deformable three-dimensional structure. However, majority of the existing 4D printing methods for liquid crystal elastomers can only fabricate planar structures, which limits their deformation designability and bearing capacity. Here we propose a direct ink writing based 4D printing method for freestanding continuous fiber reinforced composites. Continuous fibers can support freestanding structures during the printing process and improve the mechanical property and deformation ability of 4D printed structures. In this paper, the integration of 4D printed structures with fully impregnated composite interfaces, programmable deformation ability and high bearing capacity are realized by adjusting the off-center distribution of the fibers, and the printed liquid crystal composite can carry a load of up to 2805 times its own weight and achieve a bending deformation curvature of 0.33 mm-1 at 150 °C. This research is expected to open new avenues for creating soft robotics, mechanical metamaterials and artificial muscles.


Asunto(s)
Cristales Líquidos , Elastómeros , Músculos , Estructuras de las Plantas
6.
Biomater Adv ; 146: 213310, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36716597

RESUMEN

Polyetheretherketone (PEEK) has been widely used in the preparation of orthopedic implants due to its biological inertness and similar mechanical modulus to natural bone. However, the affinity between biological tissue (bone and soft tissue) and PEEK surface is weak, leading to low osseointegration and an increased risk of inflammation. The situation could be improved by modifying PEEK surface. Surfaces with good hydrophilicity and proper microtopography would promote cellular adhesion and proliferation. This work presented a two-step surface modification method to achieve the effect. Polyacrylic acid (PAA) chains were grafted on PEEK surface by UV irradiation. Then, ethylenediamine (EDA) was added to introduce amino groups and promote the cross-linking of PAA chains. Furthermore, a mathematical model was built to describe and regulate the surface topography growth process semi-quantitatively. The model fits experimental data quite well (adjusted R2 = 0.779). Results showed that the modified PEEK surface obtained superhydrophilicity. It significantly improved the adhesion and proliferation of BMSCs and MFBs by activating the FAK pathway and Rho family GTPase. The cellular affinity performed better when the surface topography was in network structure with holes in about 25 µm depth and 20-50 µm diameter. Good hydrophilicity seems necessary for the FAK pathway activation, but simply improving surface hydrophilicity might not be enough for cellular affinity improvement. Surface topography at micron scale should be a more important cue. This simple surface modification method could be contributed to further study of cell-microtopography interaction and have potential applications in clinical PEEK orthopedic implants.


Asunto(s)
Polietilenglicoles , Polímeros , Benzofenonas , Cetonas/farmacología , Cetonas/química , Polietilenglicoles/farmacología , Polietilenglicoles/química , Propiedades de Superficie , Interacciones Hidrofóbicas e Hidrofílicas
7.
J Mater Sci Mater Med ; 23(9): 2217-26, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22669285

RESUMEN

Three-dimensional printer (3DP) (Z-Corp) is a solid freeform fabrication system capable of generating sub-millimeter physical features required for tissue engineering scaffolds. By using plaster composite materials, 3DP can fabricate a universal porogen which can be injected with a wide range of high melting temperature biomaterials. Here we report results toward the manufacture of either pure polycaprolactone (PCL) or homogeneous composites of 90/10 or 80/20 (w/w) PCL/beta-tricalcium phosphate (ß-TCP) by injection molding into plaster composite porogens fabricated by 3DP. The resolution of printed plaster porogens and produced scaffolds was studied by scanning electron microscopy. Cytotoxicity test on scaffold extracts and biocompatibility test on the scaffolds as a matrix supporting murine osteoblast (7F2) and endothelial hybridoma (EAhy 926) cells growth for up to 4 days showed that the porogens removal process had only negligible effects on cell proliferation. The biodegradation tests of pure PCL and PCL/ß-TCP composites were performed in DMEM with 10 % (v/v) FBS for up to 6 weeks. The PCL/ß-TCP composites show faster degradation rate than that of pure PCL due to the addition of ß-TCP, and the strength of 80/20 PCL/ß-TCP composite is still suitable for human cancellous bone healing support after 6 weeks degradation. Combining precisely controlled porogen fabrication structure, good biocompatibility, and suitable mechanical properties after biodegradation, PCL/ß-TCP scaffolds fabricated by 3DP porogen method provide essential capability for bone tissue engineering.


Asunto(s)
Implantes Absorbibles , Sustitutos de Huesos/síntesis química , Fosfatos de Calcio/química , Poliésteres/química , Ingeniería de Tejidos/métodos , Andamios del Tejido/química , Animales , Materiales Biocompatibles/síntesis química , Materiales Biocompatibles/química , Sustitutos de Huesos/química , Huesos/efectos de los fármacos , Huesos/fisiología , Fosfatos de Calcio/síntesis química , Células Cultivadas , Simulación por Computador , Estudios de Factibilidad , Humanos , Ensayo de Materiales , Ratones , Oseointegración/efectos de los fármacos , Oseointegración/fisiología , Poliésteres/síntesis química , Porosidad , Ingeniería de Tejidos/instrumentación
8.
Dent Mater J ; 41(6): 816-823, 2022 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-35858792

RESUMEN

Compared with CAD/CAM, fused deposition modeling (FDM) 3D printing technology is simple and safe to operate and has a low cost and high material utilization rate; thus, it is widely used. The present investigation aimed to evaluate the mechanical properties and fit of polyetheretherketone (PEEK) removable partial dentures (RPDs) constructed by FDM. We analyzed mechanical properties of PEEK samples prepared by FDM, milling, or injection molding. RPDs were designed and finite element analysis models was constructed to evaluate maximum stress and strain in the RPDs, cortical bone and mucosa. Geomagic Qualify software was used to analyze gaps between the model and the tissue surface of the framework. The results showed that the compressive strength of the 3D-printed PRDs was greater than that of the injection-molded samples. Finite element analysis demonstrated that the maximum stress on the PRDs was less than the yield strength of the material. Overall, the mechanical properties and fit of the PEEK RPD fabricated by FDM technology essentially fulfilled clinical requirements.


Asunto(s)
Dentadura Parcial Removible , Polímeros , Benzofenonas , Cetonas , Polietilenglicoles , Impresión Tridimensional
9.
Comput Methods Programs Biomed ; 225: 107105, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36108412

RESUMEN

BACKGROUND AND OBJECTIVE: Rigid reconstruction of chest wall defect seriously affects the postoperative respiratory owing to neglecting the functional role of natural costal cartilage. In the study, a 3D printing PEEK flexible implant was developed to restore the deformation capability during breathing motion. MATERIALS AND METHODS: Bionic spring structures in different region of implant were designed by taking into consideration of the anatomical morphology and materials properties of costal cartilage. The biomechanical properties of the rigid and flexible implants under the chest compression were compared through the finite element analysis. Two kinds of chest wall implant samples were fabricated with fused deposition modeling (FDM) technology to evaluate experimentally the mechanical behaviors. Finally, the restoration ability of respiratory function from the flexible implant was investigated in vivo. RESULTS: The flexible implant exhibited the similar stiffness to the natural thorax and satisfied the strength demand in the chest compression. The maximal impact force of flexible implant reached to 536 N. The fatigue failure of complete flexible implant was revealed from the initiation and propagation of interlaminar crack to the fracture in a zigzag manner. Animal experiments validated that the parameters characterizing respiratory could be recovered to the preoperative and normal state. CONCLUSIONS: In the study, the flexible implant provided these advantages for perfect replication of thoracic shape, reliable safety, and great deformation capability to response respiratory movement, which given a superior treatment for chest wall reconstruction.


Asunto(s)
Pared Torácica , Benzofenonas , Polímeros , Impresión Tridimensional , Pared Torácica/cirugía
10.
Acta Biomater ; 140: 1-22, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34875360

RESUMEN

3D bioprinting has been developed as an effective and powerful technique for the fabrication of living tissue constructs in a well-controlled manner. However, most existing 3D bioprinting strategies face substantial challenges in replicating delicate and intricate tissue-specific structural organizations using mechanically weak biomaterials such as hydrogels. Embedded bioprinting is an emerging bioprinting strategy that can directly fabricate complex structures derived from soft biomaterials within a supporting matrix, which shows great promise in printing large vascularized tissues and organs. Here, we provide a state-of-the-art review on the development of embedded bioprinting including extrusion-based and light-based processes to manufacture complex tissue constructs with biomimetic architectures. The working principles, bioinks, and supporting matrices of embedded printing processes are introduced. The effect of key processing parameters on the printing resolution, shape fidelity, and biological functions of the printed tissue constructs are discussed. Recent innovations in the processes and applications of embedded bioprinting are highlighted, such as light-based volumetric bioprinting and printing of functional vascularized organ constructs. Challenges and future perspectives with regard to translating embedded bioprinting into an effective strategy for the fabrication of functional biological constructs with biomimetic structural organizations are finally discussed. STATEMENT OF SIGNIFICANCE: It is still challenging to replicate delicate and intricate tissue-specific structural organizations using mechanically-weak hydrogels for the fabrication of functional living tissue constructs. Embedded bioprinting is an emerging 3D printing strategy that enables to produce complex tissue structures directly inside a reservoir filled with supporting matrix, which largely widens the choice of bioprinting inks to ECM-like hydrogels. Here we aim to provide a comprehensive review on various embedded bioprinting techniques mainly including extrusion-based and light-based processes. Various bioinks, supporting matrices, key processing parameters as well as their effects on the structures and biological functions of resultant living tissue constructs are discussed. We expect that it can provide an important reference and generate new insights for the bioprinting of large vascularized tissues and organs with biological functions.


Asunto(s)
Bioimpresión , Materiales Biocompatibles , Bioimpresión/métodos , Hidrogeles , Impresión Tridimensional , Ingeniería de Tejidos/métodos , Andamios del Tejido/química
11.
Biomater Adv ; 141: 213119, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36152523

RESUMEN

Additive Manufactured (AM) Polyether-ether-ketone (PEEK) orthopaedic implants offer new opportunities for bone substitutes. However, owing to its chemical inertness, the integration between PEEK implants and soft tissue represents a major challenge threatening the early success of the PEEK implants. Here we investigated the influence of hydroxyapatite (HA) fillers and porous structure of AM HA/PEEK scaffolds on the integration with soft tissue through in-vitro cellular experiments and in-vivo rabbit experiments. Among the animal experiments, HA/PEEK composite scaffolds with HA contents of 0, 20 wt%, 40 wt% and pore sizes of 0.8 mm, 1.6 mm were manufactured by fused filament fabrication. The results indicated that HA promoted the proliferation and adhesion of myofibroblasts on PEEK-based composites by releasing Ca2+ to active FAK and its downstream proteins, while the surface morphology of the scaffolds was also roughened by the HA particles, both of which led to the tighter adhesion between HA/PEEK scaffolds and soft tissue in-vivo. The macroscopic bonding force between soft tissue and scaffolds was dominated by the pore size of the scaffolds but was hardly affected by neither the HA content and nor the surface morphology. Scaffolds with larger pore size bonded more strongly to the soft tissue, and the maximum bonding force reached to 5.61 ± 2.55 N for 40 wt% HA/PEEK scaffolds with pore size of 1.6 mm, which was higher than that between natural bone and soft tissue of rabbits. Although the larger pore size and higher HA content of the PEEK-based scaffolds facilitated the bonding with the soft tissue, the consequent outcome of reduced mechanical properties has to be compromised in the design of the porous PEEK-based composite implants. The present study provides engineering-accessible synergistic strategies on material components and porous architecture of AM PEEK orthopaedic implants for improving the integration with soft tissue.


Asunto(s)
Sustitutos de Huesos , Durapatita , Animales , Benzofenonas , Sustitutos de Huesos/química , Durapatita/química , Éteres , Cetonas/química , Polietilenglicoles/química , Polímeros , Porosidad , Conejos
12.
J Craniomaxillofac Surg ; 50(8): 621-626, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35760658

RESUMEN

The aim of this study was to investigate and discuss the efficacy of 3D-printed PEEK implants in personalized reconstruction of mandibular segmental defects. This study was a single-center case series. Six patients who underwent mandibular reconstruction with a custom-made 3D-printed PEEK implant were enrolled. Patient demographics, photographs, computed tomography (CT), and other clinical data were collected and analyzed pre- and postoperatively. The average patient age was 60.0 ± 15.09 years. The mean operative time was 213.33 ± 30.77 min, and the postoperative follow-up time ranged from 10 to 24 months. Mandibular segmental defects ranged from the symphysis to the condyle. Five patients did not have any postoperative complications and were satisfied with the cosmetic and functional results. One patient had to undergo removal of the PEEK implant because of implant exposure at 10 months after surgery. PEEK implants can repair different forms of defect in the mandible, maintaining the original shape of the mandible, whilst not affecting mandible functions, such as mastication and temporomandibular joint movement. However, PEEK implantation requires the strict selection of appropriate indications, especially with regard to the evaluation of soft-tissue conditions in the implanted area.


Asunto(s)
Implantes Dentales , Procedimientos de Cirugía Plástica , Adulto , Anciano , Benzofenonas , Humanos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Persona de Mediana Edad , Polímeros , Impresión Tridimensional , Procedimientos de Cirugía Plástica/métodos
13.
Biomater Transl ; 3(2): 116-133, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36105567

RESUMEN

Polyether-ether-ketone (PEEK) is believed to be the next-generation biomedical material for orthopaedic implants that may replace metal materials because of its good biocompatibility, appropriate mechanical properties and radiolucency. Currently, some PEEK implants have been used successfully for many years. However, there is no customised PEEK orthopaedic implant made by additive manufacturing licensed for the market, although clinical trials have been increasingly reported. In this review article, design criteria, including geometric matching, functional restoration, strength safety, early fixation, long-term stability and manufacturing capability, are summarised, focusing on the clinical requirements. An integrated framework of design and manufacturing processes to create customised PEEK implants is presented, and several typical clinical applications such as cranioplasty patches, rib prostheses, mandibular prostheses, scapula prostheses and femoral prostheses are described. The main technical challenge faced by PEEK orthopaedic implants lies in the poor bonding with bone and soft tissue due to its biological inertness, which may be solved by adding bioactive fillers and manufacturing porous architecture. The lack of technical standards is also one of the major factors preventing additive-manufactured customised PEEK orthopaedic implants from clinical translation, and it is good to see that the abundance of standards in the field of additive-manufactured medical devices is helping them enter the clinical market.

14.
Biotechnol Bioeng ; 108(1): 175-85, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20721897

RESUMEN

Combinatorial material synthesis is a powerful approach for creating composite material libraries for the high-throughput screening of cell-material interactions. Although current combinatorial screening platforms have been tremendously successful in identifying target (termed "hit") materials from composite material libraries, new material synthesis approaches are needed to further optimize the concentrations and blending ratios of the component materials. Here we employed a microfluidic platform to rapidly synthesize composite materials containing cross-gradients of gelatin and chitosan for investigating cell-biomaterial interactions. The microfluidic synthesis of the cross-gradient was optimized experimentally and theoretically to produce quantitatively controllable variations in the concentrations and blending ratios of the two components. The anisotropic chemical compositions of the gelatin/chitosan cross-gradients were characterized by Fourier transform infrared spectrometry and X-ray photoelectron spectrometry. The three-dimensional (3D) porous gelatin/chitosan cross-gradient materials were shown to regulate the cellular morphology and proliferation of smooth muscle cells (SMCs) in a gradient-dependent manner. We envision that our microfluidic cross-gradient platform may accelerate the material development processes involved in a wide range of biomedical applications.


Asunto(s)
Materiales Biocompatibles/síntesis química , Técnicas Químicas Combinatorias/métodos , Microfluídica , Materiales Biocompatibles/química , Proliferación Celular , Células Cultivadas , Quitosano/metabolismo , Gelatina/metabolismo , Humanos , Células Musculares/citología , Células Musculares/fisiología , Espectroscopía de Fotoelectrones , Espectroscopía Infrarroja por Transformada de Fourier
15.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 28(5): 961-7, 2011 Oct.
Artículo en Zh | MEDLINE | ID: mdl-22097264

RESUMEN

Referring to the anatomical characterization of natural spongy bone and channel network in cortical bone, we designed a new pattern of biomimetic impalnt with preset channel for blood vessel inserting to treat early femoral head necrosis. The surgical ptrocedure was simulated by CAD model. Ceramic stereolithography was applied to fabricate the green part. Other process, such as dehydration, rinsing, drying and sintering, were taken successively. The final ceramic part kept identical with the engineered part either in the shape or in the internal structure. No deformation or crack happened. Pore size, interconnected pore size, porosity and interconnected porosity of ceramic part could satisfy cellular grouth. Spectrum analysis showed that no phase transition or chemical reaction happened during fabrication process. The biocompatibility of the final part kept the same with original during beta-TCP powder. The compressive strength was 23.54 MPa, close to natural spongy bone. It is an ideal implant to treat early femoral head necroseis because it makes preimplantation of cells and biological factors, blood velssel inserting, early establishment of blood supply possible. At the same time, it could provide enough mechanical support to prevent collapse of femoral head. It could provide a wide clinical foreground.


Asunto(s)
Fosfatos de Calcio/química , Diseño Asistido por Computadora , Necrosis de la Cabeza Femoral/terapia , Ingeniería de Tejidos , Andamios del Tejido/química , Materiales Biocompatibles/química , Sustitutos de Huesos/síntesis química , Sustitutos de Huesos/química , Humanos , Porosidad , Prótesis e Implantes
16.
Exp Ther Med ; 21(4): 348, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33732321

RESUMEN

The present study aimed to evaluate the biomechanical behavior of a custom 3D-printed polyetheretherketone (PEEK) condylar prosthesis using finite element analysis and mechanical testing. The Mimics software was used to create a 3D model of the mandible, which was then imported into Geomagic Studio software to perform osteotomy of the lesion area. A customized PEEK condyle prosthesis was then designed and the finite element model of the PEEK condyle prosthesis, mandible and fixation screw was established. The maximum stress of the prosthesis and screws, as well as stress and strain of the cortical and cancellous bones in the intercuspal position, incisal clench, left unilateral molar clench and right unilateral molar clench was analyzed. The biomechanical properties of the prosthesis were studied using two models with different lesion ranges. To simulate the actual clinical situation, a special fixture was designed. The compression performance was tested at 1 mm/min for the condyle prosthesis, prepared by fused deposition modeling (FDM). The results of a finite element analysis suggested that the maximum stress of the condyle was 10.733 MPa and the maximum stress of the screw was 9.7075 MPa; both were far less than the yield strength of the material. The maximum force that the two designed prostheses were able to withstand was 3,814.7±442.6 N (Model A) and 4,245.7±348.3 N (Model B). Overall, the customized PEEK condyle prostheses prepared by FDM exhibited a uniform stress distribution and good mechanical properties, providing a theoretical basis for PEEK as a reconstruction material for repairing the temporomandibular joint.

17.
J Mech Behav Biomed Mater ; 116: 104335, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33494021

RESUMEN

Functional reconstruction of large-size mandibular continuity defect is still a major challenge in the oral and maxillofacial surgery due to the unsatisfactory repair effects and various complications. This study aimed to develop a new functional repair method for mandibular defects combined with 3D-printed polyetheretherketone (PEEK) implant and the free vascularized fibula graft, and evaluated the service performance of the implant under whole masticatory motion. The design criteria and workflows of the mandibular reconstruction were established based on the requirements of safety, functionality, and shape consistency. Both the biomechanical behavior and the mechanobiological property of mandibular reconstruction under various masticatory motion were investigated by the finite element analysis. The maximum von Mises stress of each component was lower than the yield strength of the corresponding material and the safety factor was more than 2.3 times, which indicated the security of the repair method can be guaranteed. Moreover, the actual deformation of the reconstruction model was lower than that of the normal mandible under most clenching tasks, which assured the primary stability. More than 80% of the volume elements in the bone graft can obtain effective mechanical stimulation, which benefited to reduce the risks of bone resorption. Finally, the novel repair method was applied in clinic and good clinical performances have been achieved. Compared with the conventional fibular bone graft for surgical mandibular reconstruction, this study provides excellent safety and stability to accomplish the functional reconstruction and aesthetic restoration of the mandible defect.


Asunto(s)
Reconstrucción Mandibular , Benzofenonas , Trasplante Óseo , Peroné , Cetonas , Mandíbula/cirugía , Polietilenglicoles , Polímeros , Impresión Tridimensional
18.
J Mech Behav Biomed Mater ; 118: 104475, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33773239

RESUMEN

Polyether-ether-ketone (PEEK) exhibits excellent mechanical properties and biocompatibility. Three-dimensional (3D) printing of PEEK bone substitutes has been widely used in clinical application. However, the inertness of pure PEEK hinders its integration with the surrounding bone tissue. In this study, for the first time, PEEK/hydroxyapatite (HA) composite specimens were fabricated using fused filament fabrication (FFF) technology. PEEK/HA filaments with HA contents of 0-30 wt% were fabricated via mechanical mixing and extrusion. The HA distributions inside the composite matrix and the surface morphology characteristics of the PEEK/HA composites were examined. The effects of the printing path and HA content on the mechanics of the PEEK/HA composites were systematically investigated. The results indicated that the HA particles were uniformly distributed on the composite matrix. With an increase in the HA content, the modulus of the PEEK/HA composite increased, while the strength and failure strain concomitantly decreased. When the HA content increased to 30 wt%, the tensile modulus of the composite increased by 68.6% compared with that of pure PEEK printed along the horizontal 90° path, while the tensile strength decreased by 48.2% compared with that of pure PEEK printed along the vertical 90° path. The fracture elongation of the printed specimens with different HA contents decreased in the following order: horizontal 0° > horizontal 90° > vertical 90°. The best comprehensive mechanical properties were achieved for pure PEEK fabricated along the horizontal 0° path. The results indicate that FFF technology is applicable for additive manufacturing of PEEK/HA composites with controllable compositions. Printed PEEK/HA composites have potential for applications in the design and manufacturing of personalized bone substitutes.


Asunto(s)
Materiales Biocompatibles , Durapatita , Benzofenonas , Éteres , Cetonas , Polietilenglicoles , Polímeros , Impresión Tridimensional
19.
Mater Sci Eng C Mater Biol Appl ; 128: 112333, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34474884

RESUMEN

Polyetheretherketone (PEEK) was widely applied into fabricating of orthopaedic implants, benefitting its excellent biocompatibility and similar mechanical properties to native bones. However, the inertness of PEEK hinders its integration with the surrounding bone tissue. Here PEEK scaffolds with a series of hydroxyapatite (HA) contents in gradient were manufactured via fused filament fabrication (FFF) 3D printing techniques. The influence of the pore size, HA content and printing direction on the mechanical properties of the PEEK/HA scaffolds was systematically evaluated. By adjusting the pore size and HA contents, the elastic modulus of the PEEK/HA scaffolds can be widely tuned in the range of 624.7-50.6 MPa, similar to the variation range of natural cancellous bone. Meanwhile, the scaffolds exhibited higher Young's modulus and lower compressive strength along Z printing direction. The mapping relationship among geometric parameters, HA content, printing direction and mechanical properties was established, which gave more accurate predictions and controllability of the modulus and strength of scaffolds. The PEEK/HA scaffolds with the micro-structured surface could promote cell attachment and mineralization in vitro. Therefore, the FFF-printed PEEK/HA composites scaffolds can be a good candidate for bone grafting and tissue engineering.


Asunto(s)
Durapatita , Cetonas , Benzofenonas , Polietilenglicoles , Polímeros , Porosidad , Impresión Tridimensional , Andamios del Tejido
20.
Biofabrication ; 12(3): 035012, 2020 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-32240988

RESUMEN

Selective laser sintering (SLS) is a promising additive manufacturing technique that produces biodegradable tissue-engineered scaffolds with highly porous architectures without additional supporting. However, SLS process inherently results in partially melted microstructures which significantly impair the mechanical properties of the resultant scaffolds for potential applications in tissue engineering and regenerative medicine. Here, a novel post-treatment strategy was developed to endow the SLS-fabricated polycaprolactone (PCL) scaffolds with dense morphology and enhanced mechanical properties by embedding them in dense NaCl microparticles for in-situ re-melting and re-solidification. The effects of re-melting temperature and dwelling time on the microstructures of the SLS-fabricated filaments were studied. The results demonstrated that the minimum requirements of re-melting temperature and dwelling time for sufficient treatment were 65 °C and 5 min respectively and the size of the SLS-fabricated filaments was reduced from 683.3 ± 28.0 µm to 601.6 ± 17.4 µm. This method was also highly effective in treating three-dimensional (3D) PCL lattice scaffolds, which showed improved filament quality and mechanical properties after post-treatment. The treated PCL scaffolds with an initial compressive modulus and strength of 3027.8 ± 204.2 kPa and 208.8 ± 14.5 kPa can maintain their original shapes after implantation in vivo for 24 weeks. Extensive newly-grown tissues were found to gradually penetrate into the porous regions along the PCL filaments. Although degradation occurred, the mechanical properties of the implanted constructs stably maintained. The presented method provides an innovative, green and general post-treatment strategy to improve both the filament quality and mechanical properties of SLS-fabricated PCL scaffolds for various tissue engineering applications.


Asunto(s)
Rayos Láser , Ensayo de Materiales , Poliésteres/química , Ingeniería de Tejidos , Andamios del Tejido/química , Animales , Femenino , Ratas Sprague-Dawley , Temperatura , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA