Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Biosensors (Basel) ; 14(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38667160

RESUMEN

Galactose monitoring in individuals allows the prevention of harsh health conditions related to hereditary metabolic diseases like galactosemia. Current methods of galactose detection need development to obtain cheaper, more reliable, and more specific sensors. Enzyme-containing amperometric sensors based on galactose oxidase activity are a promising approach, which can be enhanced by means of their inclusion in a redox polymer coating. This strategy simultaneously allows the immobilization of the biocatalyst to the electroactive surface and hosts the electron shuttling units. An additional deposition of capping polymers prevents external interferences like ascorbic or uric acid as well as biofouling when measuring in physiological fuels. This work studies the protection effect of poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate (MPC) and polyvinylimidazole-polysulfostyrene (P(VI-SS)) when incorporated in the biosensor design for the detection of galactose in human plasma.


Asunto(s)
Técnicas Biosensibles , Galactosa , Polímeros , Humanos , Polímeros/química , Galactosa Oxidasa , Metacrilatos/química
2.
ACS Sens ; 8(4): 1756-1765, 2023 04 28.
Artículo en Inglés | MEDLINE | ID: mdl-36943936

RESUMEN

The lifetime of implantable electrochemical glucose monitoring devices is limited due to the foreign body response and detrimental effects from ascorbic acid (AA) and uric acid (UA) interferents that are components of physiological media. Polymer coatings can be used to shield biosensors from these interferences and prolong their functional lifetime. This work explored several approaches to protect redox polymer-based glucose biosensors against such interferences by designing six targeted multi-layer sensor architectures. Biological interferents, like cells and proteins, and UA and AA interferents were found to have individual effects on the current density and operational stability of glucose biosensors, requiring individual protection and treatment. Protection against biofouling can be achieved using a poly(2-methacryloyloxyethyl phosphorylcholine-co-glycidyl methacrylate) (MPC) zwitterionic polymer coating. An enzyme-scavenging approach was compared to electrostatic repulsion by negatively charged polymers for protection against AA and UA interferences. A multi-layer novel polymer design (PD) system consisting of a cross-linkable negatively charged polyvinylimidazole-polysulfostyrene co-polymer inner layer and a cross-linkable MPC zwitterionic polymer outer layer showed the best protection against AA, UA, and biological interferences. The sensor protected using the novel PD shield displayed the lowest mean absolute relative difference between the glucose reading without the interferent and the reading value with the interferent present and also displayed the lowest variability in sensor readings in complex media. For sensor measurements in artificial plasma, the novel PD extends the linear range (R2 = 0.99) of the sensor from 0-10 mM for the control to 0-20 mM, shows a smaller decrease in sensitivity, and retains high current densities. The application of PD multi-target coating improves sensor performance in complex media and shows promise for use in sensors operating in real conditions.


Asunto(s)
Incrustaciones Biológicas , Técnicas Biosensibles , Glucosa , Glucemia , Polímeros , Ácido Úrico/análisis , Automonitorización de la Glucosa Sanguínea , Ácido Ascórbico , Incrustaciones Biológicas/prevención & control
3.
Bioelectrochemistry ; 149: 108314, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36335789

RESUMEN

A new redox polymer/bilirubin oxidase (BOD)-based gas diffusion electrode was designed to be implemented as the non-current and non-stability limiting biocathode in a glucose/O2 biofuel cell that acts as a self-powered glucose biosensor. For the proof-of-concept, a bioanode comprising the Os-complex modified redox polymer P(VI-co-AA)-[Os(bpy)2Cl]Cl and FAD-dependent glucose dehydrogenase to oxidize the analyte was used. In order to develop an optimal O2-reducing biocathode for the biofuel cell Mv-BOD as well as Bp-BOD and Mo-BOD have been tested in gas diffusion electrodes in direct electron transfer as well as in mediated electron transfer immobilized in the Os-complex modified redox polymer P(VI-co-AA)-[Os(diCl-bpy)2]Cl2. The resulting biofuel cell exhibits a glucose-dependent current and power output in the concentration region between 1 and 10 mM. To create a more realistic test environment, the performance and long-term stability of the biofuel cell-based self-powered glucose biosensor has been investigated in a flow-through cell design.


Asunto(s)
Fuentes de Energía Bioeléctrica , Técnicas Biosensibles , Oxidorreductasas actuantes sobre Donantes de Grupo CH-CH , Bilirrubina , Electrodos , Enzimas Inmovilizadas/metabolismo , Glucosa , Glucosa 1-Deshidrogenasa/metabolismo , Oxidación-Reducción , Oxidorreductasas actuantes sobre Donantes de Grupo CH-CH/metabolismo , Polímeros , Gases
4.
Bioelectrochemistry ; 146: 108128, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35429916

RESUMEN

Green microalgae are gaining attention in the renewable energy field due to their ability to convert light into energy in biophotovoltaic (BPV) cells. The poor exogenous electron transfer kinetics of such microorganisms requires the use of redox mediators to improve the performance of related biodevices. Redox polymers are advantageous in the development of subcellular-based BPV devices by providing an improved electron transfer while simultaneously serving as immobilization matrix. However, these surface-confined redox mediators have been rarely used in microorganism-based BPVs. Since electron transfer relies on the proximity between cells and the redox centres at the polymer matrix, the development of molecularly tailored surfaces is of great significance to fabricate more efficient BPV cells. We propose a bioanode integrating Chlorella vulgaris embedded in an Os complex-modified redox polymer. Chlorella vulgaris cells are functionalized with 3-aminophenylboronic acid that exhibits high affinity to saccharides in the cell wall as a basis for an improved integration with the redox polymer. Maximum photocurrents of (5 ± 1) µA cm-2 are achieved. The developed bioanode is further coupled to a bilirubin oxidase-based biocathode for a proof-of-concept BPV cell. The obtained results encourage the optimization of electron-transfer pathways toward the development of advanced microalgae-based biophotovoltaic devices.


Asunto(s)
Chlorella vulgaris , Microalgas , Ácidos Borónicos , Chlorella vulgaris/metabolismo , Oxidación-Reducción , Polímeros/metabolismo
5.
ACS Appl Mater Interfaces ; 14(41): 46421-46426, 2022 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-36194638

RESUMEN

The development of electrodes for efficient CO2 reduction while forming valuable compounds is critical. The use of enzymes as catalysts provides the advantage of high catalytic activity in combination with highly selective transformations. We describe the electrical wiring of a carbon monoxide dehydrogenase II from Carboxydothermus hydrogenoformans (ChCODH II) using a cobaltocene-based low-potential redox polymer for the selective reduction of CO2 to CO over gas diffusion electrodes. High catalytic current densities of up to -5.5 mA cm-2 are achieved, exceeding the performance of previously reported bioelectrodes for CO2 reduction based on either carbon monoxide dehydrogenases or formate dehydrogenases. The proposed bioelectrode reveals considerable stability with a half-life of more than 20 h of continuous operation. Product quantification using gas chromatography confirmed the selective transformation of CO2 into CO without any parasitic co-reactions at the applied potentials.


Asunto(s)
Monóxido de Carbono , Formiato Deshidrogenasas , Formiato Deshidrogenasas/química , Monóxido de Carbono/química , Dióxido de Carbono/química , Polímeros , Instalación Eléctrica , Electrodos , Oxidación-Reducción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA