Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
BMC Musculoskelet Disord ; 17: 151, 2016 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-27052323

RESUMEN

BACKGROUND: Adjacent fracture of the cemented vertebrae result from crushed fragile trabeculae during follow-up, suggesting impaired bone marrow integrity. This study aimed to determine if anti-osteoporotic therapy can decrease the risk of adjacent fracture in patients after vertebroplasty. METHODS: This retrospective study reviewed of cases of osteoporotic patients with magnetic resonance imaging (MRI)-proven acute vertebral fractures between 2001 and 2007. Osteoporotic patients were investigated as determined by pre-operative MRI with subsequent adjacent fracture of the cemented vertebrae and for the possibility of anti-osteoporotic therapy decreasing the progression of collapse after a minimum of 6 months follow-up. All associated co-morbidities were recorded, as well as the use of anti-osteoporotic drugs (i.e., bisphosphonate, raloxifen, calcitonin, and teriparatide). Cox regression analysis was also performed. RESULTS: The 192 vertebral fractured patients who underwent vertebroplasty and anti-osteoporotic therapy had a mean age of 74.40 ± 6.41. The basic characteristics of patients with and without adjacent fracture differed in age, body mass index, rheumatoid arthritis, and use of glucocorticoids and anti-osteoporotic drugs (Table 1). Using the Kaplan-Meier curve, anti-osteoporotic therapy after vertebroplasty had a significant effect on adjacent fracture (p = 0.037, by log rank text). After adjusting for potential confounders, patients with anti-osteoporotic therapy still had a lower adjacent fracture rate than patients without anti-osteoporotic therapy (p = 0.006; HR: 2.137, 95 % CI: 1.1238-3.690). The adjacent fracture rate also increased in old age (p = 0.019; HR: 1.049; 95 % CI:1.008-1.039) and among smokers (p = 0.026; HR: 3.891; 95 % CI: 1.175-12.890). CONCLUSIONS: In this study, adjacent fracture of cemented vertebrae is inevitable after vertebroplasty but can be mitigated by anti-osteoporotic therapy to increase bone mass.


Asunto(s)
Conservadores de la Densidad Ósea/uso terapéutico , Fracturas por Compresión/cirugía , Imagen por Resonancia Magnética , Osteoporosis/tratamiento farmacológico , Fracturas Osteoporóticas/cirugía , Vertebroplastia/efectos adversos , Anciano , Anciano de 80 o más Años , Cementos para Huesos/efectos adversos , Distribución de Chi-Cuadrado , Femenino , Fracturas por Compresión/diagnóstico , Fracturas por Compresión/etiología , Humanos , Estimación de Kaplan-Meier , Masculino , Osteoporosis/complicaciones , Osteoporosis/diagnóstico , Fracturas Osteoporóticas/diagnóstico , Fracturas Osteoporóticas/etiología , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
Nat Nanotechnol ; 18(12): 1492-1501, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37537274

RESUMEN

Dynamic therapies have potential in cancer treatments but have limitations in efficiency and penetration depth. Here a membrane-integrated liposome (MIL) is created to coat titanium dioxide (TiO2) nanoparticles to enhance electron transfer and increase radical production under low-dose X-ray irradiation. The exoelectrogenic Shewanella oneidensis MR-1 microorganism presents an innate capability for extracellular electron transfer (EET). An EET-mimicking photocatalytic system is created by coating the TiO2 nanoparticles with the MIL, which significantly enhances superoxide anions generation under low-dose (1 Gy) X-ray activation. The c-type cytochromes-constructed electron channel in the membrane mimics electron transfer to surrounding oxygen. Moreover, the hole transport in the valence band is also observed for water oxidation to produce hydroxyl radicals. The TiO2@MIL system is demonstrated against orthotopic liver tumours in vivo.


Asunto(s)
Liposomas , Shewanella , Electrones , Fusión de Membrana , Transporte de Electrón , Oxidación-Reducción
3.
Tomography ; 8(5): 2330-2338, 2022 09 16.
Artículo en Inglés | MEDLINE | ID: mdl-36136890

RESUMEN

(1) Background: Curved planar reformation (CPR) is a multiplanar reformatting technique of computed tomography (CT) commonly used during dental cone-beam CT (CBCT) to generate panorex-like images for dental evaluation. Here, we evaluated the utility of an additional CPR sequence in detecting dental pathologies in patients with chronic rhinosinusitis (CRS). (2) Methods: CRS patients who underwent paranasal sinus CT were enrolled retrospectively. The CT images featured three orthogonal sequences and a reconstructed CPR sequence. Additional dental CBCT was performed in patients with pathologies with a strongly suspected odontogenic origin. Dental pathologies detected by CT, CPR, and CBCT were analyzed. (3) Results: A total of 82 CRS patients (37 females and 45 males; mean age 47.3 ± 13.7 years) were included, of whom 23 underwent dental CBCT. In total, 1058 maxillary teeth were evaluated. Compared with paranasal sinus CT, CPR identified greater frequencies of dental pathologies, particularly caries (p < 0.001), periapical lesions (p < 0.001), and fistulae (p = 0.014). CBCT identified greater frequencies of periodontal dental pathologies (p = 0.046) and premolar caries (p = 0.002) compared with CPR. CBCT and CPR detected molar dental pathologies at similar frequencies. (4) Conclusions: CPR could increase the diagnostic rate of odontogenic pathologies compared with standard CT orthogonal views, especially when the sinusitis is caused by caries, periapical lesions, or fistulae. The addition of a CPR sequence allows for simple screening of dental pathologies in CRS patients without a need for additional radiation.


Asunto(s)
Seno Maxilar , Sinusitis , Adulto , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Humanos , Masculino , Seno Maxilar/diagnóstico por imagen , Seno Maxilar/patología , Persona de Mediana Edad , Estudios Retrospectivos , Sinusitis/diagnóstico por imagen , Sinusitis/patología , Tomografía Computarizada por Rayos X
4.
Eur Spine J ; 19(11): 1899-906, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20607571

RESUMEN

Refracture of cemented vertebrae is often seen after percutaneous vertebroplasty. The purpose of this prospective study was to evaluate pre-procedural magnetic resonance images (MRI) for the prediction of further collapse and vertebral height loss after vertebroplasty. This study included 81 consecutive patients (73 women and 8 men) with osteoporotic compression fractures. MR studies were performed 1-5 days before vertebroplasty. Patients were followed to evaluate refracture for a minimum of 6 months after treatment. Cox proportional hazards model was used to evaluate relationships between clinical data, covariates on pre-procedural MRI, and the presence of cemented vertebrae refracture. The mean refracture rate was estimated with the Kaplan-Meier method. After a mean follow-up of 23.0 ± 8.2 months, 46 cemented vertebrae (57%) experienced refracture, and the mean loss of anterior vertebral height was 11.3%. The 1-year refracture rate after vertebroplasty was 7%, and rapid increased to 76% in the third year. Cox proportional analysis showed that any 1% decrease in signal intensity on T2-weighted images of the injured vertebra will increase the refracture rate by 0.74% (OR = 0.26, 95% CI 0.08-0.81, p = 0.02), and a 1% increase in the poorly enhanced volume ratio will increase the refracture rate by 4.3% (OR = 5.32, 95% CI 1.22-23.14, p = 0.03). Quantitative pre-procedural MRI appears to be useful in exploring vertebrae with poor bone marrow integrity, which effectively predicts the subsequent refracture of cemented vertebra.


Asunto(s)
Cementos para Huesos , Imagen por Resonancia Magnética , Cuidados Preoperatorios , Fracturas de la Columna Vertebral/patología , Fracturas de la Columna Vertebral/cirugía , Vertebroplastia/métodos , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Fracturas por Compresión/epidemiología , Fracturas por Compresión/patología , Fracturas por Compresión/cirugía , Humanos , Vértebras Lumbares/lesiones , Vértebras Lumbares/cirugía , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Recurrencia , Factores de Riesgo , Fracturas de la Columna Vertebral/epidemiología , Vértebras Torácicas/lesiones , Vértebras Torácicas/cirugía , Resultado del Tratamiento
5.
Eur Spine J ; 17(4): 592-9, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18204942

RESUMEN

Percutaneous vertebroplasty is an efficient procedure to treat pain due to osteoporotic vertebral compression fractures. However, refracture of cemented vertebrae occurs occasionally after vertebroplasty. It is unclear whether such fractures are procedure-related or part of the natural course of osteoporosis. The effect of potentially important covariates on refracture risk in cemented vertebrae has not been evaluated previously. We retrospectively analyzed the incidence and possible causative mechanism of refracture in patients who had received only one vertebroplasty for a single level of vertebral compression fracture. We assessed the following covariates: age, sex, body weight, height, lumbar spine bone mineral density, treated vertebral level, pre-existing untreated vertebral compression fracture, and gas-containing vertebrae before treatment. Surgical variables, including surgical approach, cement injected, and anterior vertebral height restoration, were also analyzed. Anti-osteoporotic treatment after surgery was recorded. Multiple logistic regression analysis was used to determine the relative risk of refractures of cemented vertebrae. Over all, 98 patients were evaluated with a mean follow-up of 26.9 +/- 12.4 months (range, 7-55 months). We identified 62 refractures and the mean loss of anterior vertebral height was 13.3% (range 3.2-40.3%). The greater the anterior vertebral height obtained from vertebroplasty, the greater the risk of refracture occurring (P < 0.01). Gas-containing vertebrae were also prone to refracture after the procedure (P = 0.01). Anti-osteoporotic treatment was of borderline significance between refractured and non-refractured vertebrae (P = 0.07). Only restoration of anterior vertebral height was positively associated with refracture during the follow-ups (P < 0.01). In conclusion, refractures of cemented vertebrae after vertebroplasty occurred in 63% of osteoporotic patients. Significant anterior vertebral height restoration increases the risk of subsequent fracture in cemented vertebrae.


Asunto(s)
Cementos para Huesos , Fracturas por Compresión/prevención & control , Fracturas por Compresión/cirugía , Fracturas de la Columna Vertebral/prevención & control , Fracturas de la Columna Vertebral/cirugía , Vertebroplastia/métodos , Anciano , Femenino , Estudios de Seguimiento , Fracturas por Compresión/etiología , Humanos , Incidencia , Modelos Logísticos , Masculino , Osteoporosis/complicaciones , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Fracturas de la Columna Vertebral/etiología , Resultado del Tratamiento
6.
Laryngoscope ; 122(10): 2205-9, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22674660

RESUMEN

OBJECTIVES/HYPOTHESIS: To evaluate the efficacy of treating lower gum cancer using fluorine-18 fluorodeoxyglucose positron-emission tomography/computed tomography ([18] F-FDG PET/CT) surgical navigation to control bony margins during segmental mandibulectomy. STUDY DESIGN: This study was conducted between September 2010 and June 2011 in a tertiary referral center in southern Taiwan. METHODS: Segmental mandibulectomy was performed using surgical navigation via [18] F-FDG PET/CT. Bony margins after decalcification, the 1-year survival rate, and local control rate were evaluated. RESULTS: Ten cases of advanced lower gum cancer in male patients were treated by mandibulectomy, and the bony margins required to excise all neoplastic cells were negative in all cases by using surgical navigation. The minimal distance from the tumor border to the bony incision was 2 cm (2.0-2.9 cm). The mean follow-up period was 15.2 months (range, 6-24 months) with a 1-year survival rate of 90% and local control rate of 100%. CONCLUSIONS: The segmental mandibulectomy aided by surgical navigation with [18] F-FDG PET/CT guidance is simple and feasible to ensure adequate bony margins intraoperatively, but more patients are necessary to support these findings.


Asunto(s)
Fluorodesoxiglucosa F18 , Osteotomía Mandibular/métodos , Neoplasias de la Boca/diagnóstico , Neoplasias de la Boca/cirugía , Cirugía Asistida por Computador/métodos , Anciano , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Osteotomía Mandibular/mortalidad , Persona de Mediana Edad , Neoplasias de la Boca/patología , Imagen Multimodal , Estadificación de Neoplasias , Proyectos Piloto , Tomografía de Emisión de Positrones , Tasa de Supervivencia , Tomografía Computarizada por Rayos X
7.
ACS Appl Mater Interfaces ; 3(8): 3064-71, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21736294

RESUMEN

The quartz crystal microbalance (QCM) has a sensitivity comparable to that of the surface plasmon resonance (SPR) transducer. Molecularly imprinted polymers (MIPs) have a much lower cost than natural antibodies, they are easier to fabricate and more stable, and they exhibit satisfactory recognition ability when integrated onto sensing transducers. Hence, MIP-based QCM sensors have been used to recognize small molecules and, recently, microorganisms, but only a few have been adopted in protein sensing. In this work, a mixed salivary protein and poly(ethylene-co-vinyl alcohol), EVAL, solution is coated onto a QCM chip and a molecularly imprinted EVAL thin film formed by thermally induced phase separation (TIPS). The optimal ethylene mole ratios of the commercially available EVALs for the imprinting of amylase, lipase and lysozyme were found to be 32, 38, and 44 mol %, respectively. Finally, the salivary protein-imprinted EVAL-based QCM sensors were used to detect amylase, lipase and lysozyme in real samples (saliva) and their effectiveness was compared with that of a commercial ARCHITECT ci 8200 chemical analysis system. The limits of detection (LOD) for those salivary proteins were as low as ∼pM.


Asunto(s)
Enzimas/análisis , Impresión Molecular/métodos , Polivinilos/química , Tecnicas de Microbalanza del Cristal de Cuarzo/métodos , Saliva/enzimología , Amilasas/análisis , Humanos , Lipasa/análisis , Muramidasa/análisis
8.
Clin Nucl Med ; 36(7): 518-25, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21637051

RESUMEN

PURPOSE: This study aimed to evaluate the diagnostic value of fused fluorodeoxyglucose positron emission tomography and magnetic resonance imaging (PET/MRI) compared with PET/computed tomography (CT), MRI, and CT in assessing surrounding tissue invasion of advanced buccal squamous cell carcinoma (BSCC). MATERIALS AND METHODS: PET/CT and MRI were performed in 17 consecutive patients with suspected masticator space invasion of BSCC from CT images. Attenuation-corrected PET and head and neck MRI datasets were registered. For pathologic correlation, 4 regions of interest were examined, including the maxilla, mandible, pterygoid, and masseter muscle. The tumor maximal diameter, measured by different imaging modalities, was correlated with pathology results. RESULTS: All PET/MRI fusions were verified as well matched using specific anatomic criteria. For pathology results, 1 patient had inflammation only, 1 had spindle cell cancer, and 15 had squamous cell cancer. Of 64 regions of interest, 20 (31.3%) harbored tumor invasion. The likelihood ratio was highest in fused PET/MRI (42.56) compared with PET/CT (25.02), MRI (22.94), and CT (8.6; all P < 0.05). The sensitivity and specificity of fused PET/MRI were also highest among the 4 modalities (90.0%/90.9%, 80.0%/84.1%, 80.0%/79.5%, and 55.0%/81.8%, respectively). The level of confidence was higher in fused PET/MRI or MRI than in PET/CT or CT (85.9%, 85.9%, 70.3%, 73.4%, respectively). The maximal lesion size was 3.0 to 6.0 cm in the pathology specimen. Regression analysis showed better agreement between fused PET/MRI and pathology results. CONCLUSIONS: Fused PET/MRI is more reliable for focal invasion assessment and tumor size delineation in advanced BSCC compared with PET/CT, MRI, and CT. PET/CT has the lowest confidence level, which may limit its use in the clinical setting.


Asunto(s)
Carcinoma de Células Escamosas/patología , Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética , Neoplasias de la Boca/patología , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Adulto , Anciano , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/epidemiología , Demografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias de la Boca/diagnóstico por imagen , Neoplasias de la Boca/epidemiología , Invasividad Neoplásica , Estadificación de Neoplasias , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad
9.
Cardiovasc Intervent Radiol ; 31 Suppl 2: S231-5, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18080823

RESUMEN

Percutaneous vertebroplasty has been established as a safe and effective treatment for compression fractures of osteoporotic vertebrae. Complications of vertebroplasty, such as infection or anterior cement extrusion, are rare. Herein, we report an unusual presentation in an immunocompromised patient with an insidious infection of the disk. This infection resulted in dislodgment of the cement inferiorly and a compression fracture of the adjacent vertebra 6 months after vertebroplasty. We discuss the significance of this case and compare it with 7 others found in the literature.


Asunto(s)
Dolor de Espalda/etiología , Dolor de Espalda/cirugía , Cementos para Huesos/efectos adversos , Fracturas por Compresión/cirugía , Huésped Inmunocomprometido , Compresión de la Médula Espinal/etiología , Compresión de la Médula Espinal/cirugía , Fracturas de la Columna Vertebral/cirugía , Anciano , Femenino , Fracturas por Compresión/diagnóstico , Humanos , Imagen por Resonancia Magnética , Dimensión del Dolor , Fracturas de la Columna Vertebral/diagnóstico , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA