Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Endovasc Ther ; 22(4): 495-505, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26018400

RESUMEN

PURPOSE: To evaluate the effectiveness of the Viabahn stent-graft in the treatment of superficial femoral artery (SFA) occlusive disease. METHODS: A systematic review and meta-analysis of published studies was performed to evaluate the efficacy of the Viabahn for SFA lesions. Studies were stratified according to controlled vs uncontrolled design and analyzed using random-effects models. Outcomes are reported as the risk ratio (RR) and 95% confidence interval (CI). Four prospective randomized controlled trials, one retrospective controlled study, and 9 uncontrolled studies were identified. RESULTS: In controlled studies, primary patency with the Viabahn was superior to other interventions at 1 year (RR 0.63, 95% CI 0.49 to 0.82, p<0.001) and ankle-brachial index (ABI) improvement was greater at 6 months (mean difference 0.05, 95% CI 0.01 to 0.09, p=0.01) compared with other interventions. Subgroup analysis demonstrated a lower incidence of stent fracture in lesions with >15-cm stented lengths. In uncontrolled studies, ABI improvement was consistently superior at all measurement points during follow-up. CONCLUSIONS: Current evidence suggests that the Viabahn stent-graft is a safe and effective option for symptomatic SFA lesions. Prospective multicenter randomized controlled trials with long-term follow-up are needed to confirm the sustained efficacy of the Viabahn device.


Asunto(s)
Arteriopatías Oclusivas/cirugía , Prótesis Vascular , Arteria Femoral , Stents , Aleaciones , Humanos , Politetrafluoroetileno , Diseño de Prótesis , Grado de Desobstrucción Vascular
2.
J Endovasc Ther ; 17(6): 687-93, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21142474

RESUMEN

PURPOSE: To analyze a single-center experience of fibrin glue sac embolization to eliminate type I endoleaks after endovascular aneurysm repair (EVAR), assessing the feasibility and effectiveness of the technique in long-term follow-up. METHODS: A retrospective study was conducted involving 783 EVAR patients treated between August 2002 and February 2009. Under a standardized protocol, 42 (5.4%) patients (37 men; mean age 73 ± 8 years) underwent intraoperative transcatheter fibrin glue sac embolization to resolve type I endoleak persisting after initial intraoperative maneuvers to close the leak or in necks too short or angulated for cuff placement. Intrasac pressure was measured before and after glue injection. Computed tomographic angiography was performed to assess the outcome after 3, 6, and 12 months and annually thereafter. RESULTS: In this type I endoleak cohort, 16 (38.1%) patients had proximal necks <10 mm long, and 5 (11.9%) patients had proximal neck angulation >60°; 22 additional devices (8 stents, 14 cuffs) had been placed in the initial attempts to resolve the endoleaks. After fibrin glue injection, 41 (97.6%) of the 42 endoleaks were resolved using a mean 15 ± 10 mL of glue. Intrasac pressure decreased significantly in successfully treated cases. The patient who failed embolotherapy was converted to open surgery (2.4%); he died 2 months later from multiorgan failure. Two (4.8%) patients died in the perioperative period from myocardial infarction. One (2.4%) patient developed right lower extremity ischemia unrelated to the fibrin glue treatment. There were no allergic reactions. Over a median follow-up of 39.9 months (range 10-88), 3 (7.1%) patients died (1 aneurysm-related). Cumulative survival was 90.5% at 1 year, 87.0% at 3 years, and 82.6% at 5 years. The mean maximal aneurysm diameter fell from the baseline 59.5 ± 14.7 mm to 49.0 ± 11.6 mm (p<0.001). Of the 4 patients with increased aneurysm diameter during follow-up, 1 was converted, 2 are being observed due to advanced age, and 1 died of renal failure. No recurrent type I endoleak or glue-related complications were observed in follow-up. CONCLUSION: Fibrin glue sac embolization to eliminate type I endoleak after EVAR yielded excellent results in our experience, effectively and durably resolving the leaks. Balloon occlusion of the proximal aorta must be done during glue injection to block proximal flow and facilitate formation of a structured fibrin clot.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular , Embolización Terapéutica , Endofuga/terapia , Procedimientos Endovasculares , Adhesivo de Tejido de Fibrina/administración & dosificación , Adhesivos Tisulares/administración & dosificación , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Aortografía/métodos , Oclusión con Balón , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , China , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Estudios de Factibilidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Reoperación , Estudios Retrospectivos , Stents , Tasa de Supervivencia , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA