1.
Micromachines (Basel) ; 9(7)2018 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-30424285

RESUMEN

Obstructive sleep apnea (OSA), which is caused by obstructions of the upper airway, is a syndrome with rising prevalence. Mandibular advancement splints (MAS) are oral appliances for potential treatment of OSA. This work proposes a highly-sensitive pressure sensing array integrated with a system-on-chip (SoC) embedded in a MAS. The device aims to measure tongue pressure distribution in order to determine the efficacy of the MAS for treating OSA. The flexible sensing array consists of an interdigital electrode pair array assembled with conductive polymer films and an SoC capable of retrieving/storing data during sleep, and transmitting data for analysis after sleep monitoring. The surfaces of the conductive polymer films were patterned with microdomed structures, which effectively increased the sensitivity and reduced the pressure sensing response time. The measured results also show that the crosstalk effect between the sensing elements of the array was negligible. The sensitivity of the sensing array changed minimally after the device was submerged in water for up to 100 h.

2.
IEEE Trans Biomed Eng ; 56(2): 462-70, 2009 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19342331

RESUMEN

A quick wireless label-free detection of disease-related C-reactive proteins (CRPs) using a 200-microm-long microelectromechanical systems (MEMS) microcantilever housed in a 7 x 7 mm(2) reaction chamber with a safe reusable feature is reported. The assay time ranges from about 30 min to 3 h, depending on accuracy. The deflection of the microcantilever due to specific CRP-antiCRP binding is detected using a position-sensitive detector. The converted bio-signal is transmitted by a custom designed wireless amplitude-shift-keying (ASK) transceiver IC fabricated in a 0.18 microm CMOS process. CRP concentrations from 1 microg/mL to 500 microg/mL can be detected. A 0.2-Hz 1-V ac signal instead of traditional bases/acids is applied to the bio-MEMS sensor to unbind the CRP from the microcantilever for reusability.


Asunto(s)
Técnicas Biosensibles/instrumentación , Proteína C-Reactiva/análisis , Sistemas Microelectromecánicos/instrumentación , Nanotecnología/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Enfermedades Cardiovasculares/diagnóstico , Dimetilpolisiloxanos/química , Diseño de Equipo , Equipo Reutilizado , Humanos , Monitoreo Ambulatorio/instrumentación