Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Langmuir ; 38(10): 3223-3233, 2022 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-35245076

RESUMEN

This paper presents the fabrication of an alkaline-responsive drug carrier, chitosan@giant liposome (CS-GL), by using an ultrasound-integrated microfluidic approach. On the microfluidic chip, water/oil/water droplets are first prepared and then move through an area of ultrasonic radiation to improve the regional saturation of organic solvent and accelerate its removal. At the same time, phospholipid molecules in the oil phase of the droplets are efficiently self-assembled into giant liposomes (GLs). Subsequently, microfluidic channels combined with an up-down separated structure can help in the fabrication and purification of the GLs. Due to the electrostatic interaction between the amino group of chitosan and the phosphate group of phospholipids, the GLs and chitosan are assembled into CS-GLs. The change of ζ potential after this operation indicates that chitosan is coated on the surface of GLs. The formed CS-GLs are monodispersed with a 54.1 ± 0.7 µm diameter and high drug encapsulation efficiency (∼96%), and the structural integrity can be kept without leakage of contents for more than a week in an acid medium (pH = 1.2). When this structure is placed in an aqueous solution of pH = 7.8, chitosan precipitates gradually and detaches from the GL, causing its rupture. The drug encapsulated in a single CS-GL can be rapidly released within 4 s, and 99.6% of the CS-GL carriers can complete the release within 10 min.


Asunto(s)
Quitosano , Fenómenos Químicos , Quitosano/química , Portadores de Fármacos/química , Liposomas/química , Microfluídica
2.
Sensors (Basel) ; 22(12)2022 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-35746111

RESUMEN

Curved pedestrian bridges are important urban infrastructure with the desired adaptability to the landscape constraints and with aesthetic benefits. Pedestrian bridges feature thin cross-sections, which provide sufficient load capacities but lead to low natural frequencies that make the bridges susceptible to vibration under pedestrian excitation. This study investigates the lateral vibration of a curved bridge with a small radius down to 20 m, proposes an approach to mitigate the lateral vibration of bridges with large curvatures using distributed multiple tuned mass dampers (MTMD), and conducts in-situ bridge tests to evaluate the vibration mitigation performance. The lateral vibration was investigated through in-situ tests and finite element analysis as well as the code requirements. The key parameters of the distributed MTMD system were improved by strategically selecting the mass ratio, bandwidth, center frequency ratio, and damper number. The results showed that the curved bridge was subjected to significant lateral vibration due to the coupling of torque and moment, and the recommended design parameters for the studied bridge were derived, i.e., the total mass ratio is 0.02, bandwidth is 0.15, center frequency ratio is 1.0, and damper number is 3. The proposed approach effectively improves the deployment of MTMD for lateral vibration control of the curved bridge. The field tests showed that the vibration was reduced by up to 82% by using the proposed approach.


Asunto(s)
Peatones , Vibración , Análisis de Elementos Finitos , Humanos , Radio (Anatomía) , Acero
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA