Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Int J Mol Sci ; 24(11)2023 Jun 04.
Artículo en Inglés | MEDLINE | ID: mdl-37298690

RESUMEN

Titanium implantation success may be compromised by Staphylococcus aureus surface colonization and posterior infection. To avoid this issue, different strategies have been investigated to promote an antibacterial character to titanium. In this work, two antibacterial agents (silver nanoparticles and a multifunctional antimicrobial peptide) were used to coat titanium surfaces. The modulation of the nanoparticle (≈32.1 ± 9.4 nm) density on titanium could be optimized, and a sequential functionalization with both agents was achieved through a two-step functionalization method by means of surface silanization. The antibacterial character of the coating agents was assessed individually as well as combined. The results have shown that a reduction in bacteria after 4 h of incubation can be achieved on all the coated surfaces. After 24 h of incubation, however, the individual antimicrobial peptide coating was more effective than the silver nanoparticles or their combination against Staphylococcus aureus. All tested coatings were non-cytotoxic for eukaryotic cells.


Asunto(s)
Nanopartículas del Metal , Titanio , Titanio/farmacología , Plata/farmacología , Materiales Biocompatibles Revestidos/farmacología , Antibacterianos/farmacología , Staphylococcus aureus , Propiedades de Superficie
2.
Int J Mol Sci ; 24(10)2023 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-37240108

RESUMEN

Previously, functional coatings on 3D-printed titanium implants were developed to improve their biointegration by separately incorporating Ga and Ag on the biomaterial surface. Now, a thermochemical treatment modification is proposed to study the effect of their simultaneous incorporation. Different concentrations of AgNO3 and Ga(NO3)3 are evaluated, and the obtained surfaces are completely characterized. Ion release, cytotoxicity, and bioactivity studies complement the characterization. The provided antibacterial effect of the surfaces is analyzed, and cell response is assessed by the study of SaOS-2 cell adhesion, proliferation, and differentiation. The Ti surface doping is confirmed by the formation of Ga-containing Ca titanates and nanoparticles of metallic Ag within the titanate coating. The surfaces generated with all combinations of AgNO3 and Ga(NO3)3 concentrations show bioactivity. The bacterial assay confirms a strong bactericidal impact achieved by the effect of both Ga and Ag present on the surface, especially for Pseudomonas aeruginosa, one of the main pathogens involved in orthopedic implant failures. SaOS-2 cells adhere and proliferate on the Ga/Ag-doped Ti surfaces, and the presence of gallium favors cell differentiation. The dual effect of both metallic agents doping the titanium surface provides bioactivity while protecting the biomaterial from the most frequent pathogens in implantology.


Asunto(s)
Galio , Titanio , Titanio/farmacología , Titanio/química , Plata/farmacología , Plata/química , Oseointegración , Porosidad , Galio/farmacología , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/química , Antibacterianos/farmacología , Antibacterianos/química , Propiedades de Superficie
3.
Int J Mol Sci ; 20(6)2019 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-30901841

RESUMEN

Synergizing integrin and cell-membrane heparan sulfate proteoglycan signaling on biomaterials through peptidic sequences is known to have beneficial effects in the attachment and behavior of osteoblasts; however, controlling the exact amount and ratio of peptides tethered on a surface is challenging. Here, we present a dual molecular-based biointerface combining integrin (RGD) and heparin (KRSR)-binding peptides in a chemically controlled fashion. To this end, a tailor-made synthetic platform (PLATF) was designed and synthesized by solid-phase methodologies. The PLATF and the control linear peptides (RGD or KRSR) were covalently bound to titanium via silanization. Physicochemical characterization by means of contact angle, Raman spectroscopy and XPS proved the successful and stable grafting of the molecules. The biological potential of the biointerfaces was measured with osteoblastic (Saos-2) cells both at short and long incubation periods. Biomolecule grafting (either the PLATF, RGD or KRSR) statistically improved (p < 0.05) cell attachment, spreading, proliferation and mineralization, compared to control titanium. Moreover, the molecular PLATF biointerface synergistically enhanced mineralization (p < 0.05) of Saos-2 cells compared to RGD or KRSR alone. These results indicate that dual-function coatings may serve to improve the bioactivity of medical implants by mimicking synergistic receptor binding.


Asunto(s)
Membrana Celular/metabolismo , Integrinas/metabolismo , Oligopéptidos/metabolismo , Osteoblastos/metabolismo , Proteoglicanos/metabolismo , Adhesión Celular , Línea Celular , Movimiento Celular , Proliferación Celular , Fenómenos Químicos , Materiales Biocompatibles Revestidos/química , Matriz Extracelular/metabolismo , Integrinas/química , Oligopéptidos/química , Proteoglicanos/química , Análisis Espectral
4.
J Mater Sci Mater Med ; 29(8): 131, 2018 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-30088100

RESUMEN

The aim is to investigate the premature catastrophic fracture produced for different periods during clinical endodontic treatment of two brands of NiTi endodontic rotary instruments. 3 samples as-received, 6 samples used with patients for 2 and 7 h and 5 samples fractured were studied for each brand of endodontic NiTi rotary instruments. Transformation temperatures (Ms, Mf, As and Af) and enthalpies of transformation were determined by calorimetry. Critical stresses until fracture (σß→SIM, σSIM→ß) were obtained using an electromechanical testing machine. The samples were also visualized by Scanning Electron Microscopy. Calorimetric studies have shown an increase of the Ms and As transformation temperatures with time of use as well as a decrease of their stress transformations. Moreover, reverse transformation enthalpies decreased along the time. The enthalpies of transformation decreased because martensitic plates were anchored, which prevented their transformation to austenite; thus losing its superelastic effect. The stabilisation of the martensitic plates induced the collapse of the structure and so the main cause for the fracture. The heat treatment proposed has been increased the life in service of NiTi superelastic endodontic instruments recovering theirs superelastic effect.


Asunto(s)
Aleaciones/química , Instrumentos Dentales , Materiales Biocompatibles , Humanos , Ensayo de Materiales , Temperatura , Termodinámica
5.
J Mater Sci Mater Med ; 29(11): 164, 2018 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-30392142

RESUMEN

Peri-implantitis is an infectious disease that affects the supporting soft and hard tissues around dental implants and its prevalence is increasing considerably. The development of antibacterial strategies, such as titanium antibacterial-coated surfaces, may be a promising strategy to prevent the onset and progression of peri-implantitis. The aim of this study was to quantify the biofilm adhesion and bacterial cell viability over titanium disc with or without antibacterial surface treatment. Five bacterial strains were used to develop a multispecies oral biofilm. The selected species represent initial (Streptococcus oralis and Actinomyces viscosus), early (Veillonella parvula), secondary (Fusobacterium nucleatum) and late (Porphyromonas gingivalis) colonizers. Bacteria were sequentially inoculated over seven different types of titanium surfaces, combining different roughness level and antibacterial coatings: silver nanoparticles and TESPSA silanization. Biofilm formation, cellular viability and bacterial quantification over each surface were analyzed using scanning electron microscopy, confocal microscopy and real time PCR. Biofilm formation over titanium surfaces with different bacterial morphologies could be observed. TESPSA was able to significantly reduce the cellular viability when compared to all the surfaces (p < 0.05). Silver deposition on titanium surface did not show improved results in terms of biofilm adhesion and cellular viability when compared to its corresponding non-coated surface. The total amount of bacterial biofilm did not significantly differ between groups (p > 0.05). TESPSA was able to reduce biofilm adhesion and cellular viability. However, silver deposition on titanium surface seemed not to confer these antibacterial properties.


Asunto(s)
Antibacterianos/farmacología , Bacterias/efectos de los fármacos , Biopelículas/efectos de los fármacos , Titanio , Antibacterianos/química , Adhesión Bacteriana , Implantes Dentales/microbiología , Humanos , Propiedades de Superficie
6.
J Mater Sci Mater Med ; 27(8): 124, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27318469

RESUMEN

Novel researches are focused on the prevention and management of post-operative infections. To avoid this common complication of implant surgery, it is preferable to use new biomaterials with antibacterial properties. Therefore, the aim of this work is to develop a method of combining the antibacterial properties of antibiotic-loaded poly(3-hydroxybutyrate) (PHB) nano- and micro-spheres and poly(ethylene glycol) (PEG) as an antifouling agent, with titanium (Ti), as the base material for implants, in order to obtain surfaces with antibacterial activity. The Ti surfaces were linked to both PHB particles and PEG by a covalent bond. This attachment was carried out by firstly activating the surfaces with either Oxygen plasma or Sodium hydroxide. Further functionalization of the activated surfaces with different alkoxysilanes allows the reaction with PHB particles and PEG. The study confirms that the Ti surfaces achieved the antibacterial properties by combining the antibiotic-loaded PHB spheres, and PEG as an antifouling agent.


Asunto(s)
Antibacterianos/química , Hidroxibutiratos/química , Poliésteres/química , Polietilenglicoles/química , Titanio/química , Materiales Biocompatibles/química , Recuento de Colonia Microbiana , Escherichia coli/efectos de los fármacos , Microscopía Electrónica de Rastreo , Microesferas , Oxígeno/química , Gases em Plasma , Propilaminas/química , Silanos/química , Espectrometría por Rayos X , Propiedades de Superficie
7.
J Mater Sci Mater Med ; 25(2): 311-20, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24202914

RESUMEN

This study investigated the effect of two different activation methods on the surface chemical composition of a CoCrMo-alloy. The activation was performed with oxygen plasma (OP) or nitric acid (NA). The surface physical-chemical properties were thoroughly characterized by means of several analytical techniques: X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS), zinc-complex substitution technique, contact angle, and interferometry. The surface modification was evaluated by assessing contamination removal, the "active" hydroxyl groups (OH-act) present at the surface, the metal oxide ratio (CoyO x (-) /CryO x (-) ) and changes in the chemical composition and topography of the oxide layer. XPS experimental data showed for both methods (OP and NA) a significant decrease of the carbon contents (C 1s) associated with contaminants and at the same time changes in the atomic composition of the oxide layer (O 1s). In addition, the O 1s XPS spectra showed differences between the percentage of OH(-) before and after OP or NA treatment, leading to the conclusion that both methods are effective for surface "cleaning" and activation. These results were further investigated and corroborated by ToF-SIMS analysis and zinc complex substitution technique. The general conclusion was that NA is more efficient in terms of contaminants removal and generation of accessible OH-act present at the surface and without altering the native metal oxide ratio (CoyO x (-) /CryO x (-) ) considered to be essential for biocompatibility.


Asunto(s)
Aleaciones de Cromo , Óxidos/química , Materiales Biocompatibles , Espectroscopía de Fotoelectrones , Espectrometría de Masa de Ion Secundario , Propiedades de Superficie
8.
J Vis Exp ; (209)2024 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-39037246

RESUMEN

The rat has long served as a valuable animal model in implant dentistry and orthopedics, particularly in studying the interactions between biomaterials and bone tissue. The rat's tibia is frequently chosen due to its easy surgical access through thin tissue layers (skin and muscle) and the flattened shape of its medial face, facilitating the surgical insertion of intraosseous devices. Additionally, this model enables the induction of specific diseases, mimicking various clinical conditions to assess biological responses to different implant conditions like geometry, surface texture, or biological cues. However, despite its robust cortical structure, certain intraosseous devices may require adaptations in design and size for successful implantation. Therefore, establishing standardized surgical methods for manipulating both soft and hard tissues in the implantation region is essential for ensuring proper implant or screw device placement, particularly in fields like implant dentistry and orthopedics. This study included eighty Sprague Dawley rats divided into two groups based on their respective diseases: Group 1 with osteoporosis and Group 2 with Type 2 Diabetes. Implantations were performed at 4 weeks and 12 weeks, with the same surgeon following a consistent surgical technique. A positive biological response was observed, indicating complete osseointegration of all implants placed. These results validate the success of the surgical protocol, which can be replicated for other studies and serve as a benchmark for the biomaterials community. Notably, osseointegration values remained stable at both 4 weeks and 12 weeks for both disease models, demonstrating a durable integration of the implant over time and emphasizing the establishment of an intimate bone connection as early as 4 weeks.


Asunto(s)
Osteoporosis , Ratas Sprague-Dawley , Tibia , Animales , Ratas , Tibia/cirugía , Osteoporosis/cirugía , Diabetes Mellitus Tipo 2/cirugía , Modelos Animales de Enfermedad , Femenino , Diabetes Mellitus Experimental/cirugía
9.
J Clin Med ; 13(6)2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38541858

RESUMEN

Background: Scientific literature lacks strong support for using narrow diameter implants (NDI) in high masticatory force areas, especially in molars. Implant splinting in cases of multiple missing teeth reduces lateral forces, improves force distribution, and minimizes stress on implants. However, no studies have evaluated the fatigue load resistance of unitary or splinted implants. Methods: This in vitro study compares five groups of new metal alloy implants, including unitary and splinted implants with varying diameters. Mechanical characterization was assessed using a BIONIX 370 testing machine (MTS, Minneapolis, MN, USA) according to ISO 14801. For each of the five study sample groups, (n = 5) specimens underwent monotonic uniaxial compression at break testing and (n = 15) cyclic loading to determine the maximum force (Fmax) and the fatigue life (LF) values. Scanning electron microscopy (SEM) was employed for the fractographic analysis of the fractured samples. Results: The Fmax values for unitary samples ranged from 196 N to 246 N, whereas the two-splinted samples displayed significantly higher values, ranging from 2439 N to 3796 N. Similarly, the LF values for unitary samples ranged from 118 N to 230 N, while the two-splinted samples exhibited notably higher values, ranging from 488 N to 759 N. Conclusions: The observed resistance difference between sample groups in terms of Fmax and LF may be due to variations in effective cross-sectional area, determined by implant diameter and number. Additionally, this disparity may indicate a potential stiffening effect resulting from the splinting process. These findings have significant implications for dental clinical practice, suggesting the potential use of splinted sets of small-sized NDI as replacements for posterior dentition (premolars and molars) in cases of alveolar bone ridge deficiencies.

10.
Adv Healthc Mater ; 12(21): e2203307, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37100430

RESUMEN

The formation of a biological seal around the neck of titanium (Ti) implants is critical for ensuring integration at the gingival site and for preventing bacterial colonization that may lead to periimplantitis. This process is guided by activated fibroblasts, named myofibroblasts, which secrete extracellular matrix (ECM) proteins and ECM-degrading enzymes resolving the wound. However, in some cases, Ti is not able to attract and activate fibroblasts to a sufficient extent, which may compromise the success of the implant. Fibronectin (FN) is an ECM component found in wounds that is able to guide soft tissue healing through the adhesion of cells and attraction of growth factors (GFs). However, clinical use of FN functionalized Ti implants is problematic because FN is difficult to obtain, and is sensitive to degradation. Herein, functionalizing Ti with a modified recombinant heparin binding II (HBII) domain of FN, mutated to include an Arg-Gly-Asp (RGD) sequence for promoting both fibroblast adhesion and GF attraction, is aimed at. The HBII-RGD domain is able to stimulate fibroblast adhesion, spreading, proliferation, migration, and activation to a greater extent than the native HBII, reaching values closer to those of full-length FN suggesting that it might induce the formation of a biological sealing.


Asunto(s)
Fibronectinas , Titanio , Fibronectinas/metabolismo , Titanio/farmacología , Titanio/química , Adhesión Celular/fisiología , Células Cultivadas , Proteínas de la Matriz Extracelular/metabolismo , Oligopéptidos , Fibroblastos , Heparina
11.
Biomater Adv ; 146: 213311, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36709627

RESUMEN

The rapid integration in the bone tissue and the prevention of bacterial infection are key for the success of the implant. In this regard, a silver (Ag)-doped thermochemical treatment that generate an Ag-doped calcium titanate layer on titanium (Ti) implants was previously developed by our group to improve the bone-bonding ability and provide antibacterial activity. In the present study, the biological and antibacterial potential of this coating has been further studied. In order to prove that the Ag-doped layer has an antibacterial effect with no detrimental effect on the bone cells, the behavior of osteoblast-like cells in terms of cell adhesion, morphology, proliferation and differentiation was evaluated, and the biofilm inhibition capacity was assessed. Moreover, the competition by the surface between cell and bacteria was carried out in two different co-culture methods. Finally, the treatment was applied to porous Ti implants to study in vivo osteointegration. The results show that the incorporation of Ag inhibits the biofilm formation and has no effect on the performance of osteoblast-like cells. Therefore, it can be concluded that the Ag-doped surface is capable of preventing bone bacterial infection and providing suitable osseointegration.


Asunto(s)
Plata , Titanio , Plata/farmacología , Titanio/farmacología , Materiales Biocompatibles Revestidos/farmacología , Materiales Biocompatibles Revestidos/metabolismo , Antibacterianos/farmacología , Osteoblastos/metabolismo , Bacterias
12.
Materials (Basel) ; 15(15)2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35955326

RESUMEN

The use of a PMMA composite with graphene is being commercialized for application as dental prostheses. The different proportions of fibers provide a wide range of colors that favors dental esthetics in prostheses. However, there are no studies that have explained the influence that graphene has on the mechanical properties. In this contribution, we studied the PMMA and PMMA material with graphene fibers (PMMA-G) in the form of discs as supplied for machining. The presence of graphene fibers has been studied by Raman spectroscopy and the Shore hardness and Vickers micro hardness were determined. Mechanical compression tests were carried out to obtain the values of maximum strength and Young's modulus (E) and by means of pin-on-disc wear tests, the specific wear rate and the friction coefficients were determined following the established international standards. Finally, the samples were characterized by field emission scanning electron microscopy (FESEM) to characterize the graphene's morphology inside the PMMA. The results showed the presence of graphene in PMMA and was estimated in an amount of 0.1027% by weight in G-PMMA. The Shore hardness and Vickers microhardness values did not show statistically significant differences. Differences were observed in the compression maximum strength (129.43 MPa for PMMA and 140.23 for PMMA-G) and E values (2.01 for PMMA and 2.89 GPa for PMMA-G) as well as in the lower wear rate for the G-PMMA samples (1.93 × 10−7 for PMMA and 1.33 × 10−7 mm3/N·m) with a p < 0.005. The coefficients of friction for PMMA-G decreased from 0.4032 for PMMA to 0.4001 for PMMA-G. From the results obtained, a slight content in graphene produced a significant improvement in the mechanical properties that could be observed in the prosthesis material. Therefore, we can state that the main attraction of this material for dental prosthesis is its esthetics.

13.
Materials (Basel) ; 15(2)2022 Jan 12.
Artículo en Inglés | MEDLINE | ID: mdl-35057263

RESUMEN

The passivation of titanium dental implants is performed in order to clean the surface and obtain a thin layer of protective oxide (TiO2) on the surface of the material in order to improve its behavior against corrosion and prevent the release of ions into the physiological environment. The most common chemical agent for the passivation process is hydrochloric acid (HCl), and in this work we intend to determine the capacity of citric acid as a passivating and bactericidal agent. Discs of commercially pure titanium (c.p.Ti) grade 4 were used with different treatments: control (Ctr), passivated by HCl, passivated by citric acid at 20% at different immersion times (20, 30, and 40 min) and a higher concentration of citric acid (40%) for 20 min. Physical-chemical characterization of all of the treated surfaces has been carried out by scanning electronic microscopy (SEM), confocal microscopy, and the 'Sessile Drop' technique in order to obtain information about different parameters (topography, elemental composition, roughness, wettability, and surface energy) that are relevant to understand the biological response of the material. In order to evaluate the corrosion behavior of the different treatments under physiological conditions, open circuit potential and potentiodynamic tests have been carried out. Additionally, ion release tests were realized by means of ICP-MS. The antibacterial behavior has been evaluated by performing bacterial adhesion tests, in which two strains have been used: Pseudomonas aeruginosa (Gram-) and Streptococcus sanguinis (Gram+). After the adhesion test, a bacterial viability study has been carried out ('Life and Death') and the number of colony-forming units has been calculated with SEM images. The results obtained show that the passivation with citric acid improves the hydrophilic character, corrosion resistance, and presents a bactericide character in comparison with the HCl treatment. The increasing of citric acid concentration improves the bactericide effect but decreases the corrosion resistance parameters. Ion release levels at high citric acid concentrations increase very significantly. The effect of the immersion times studied do not present an effect on the properties.

14.
Materials (Basel) ; 14(11)2021 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-34072082

RESUMEN

The surface modification by the formation of apatitic compounds, such as hydroxyapatite, improves biological fixation implants at an early stage after implantation. The structure, which is identical to mineral content of human bone, has the potential to be osteoinductive and/or osteoconductive materials. These calcium phosphates provoke the action of the cell signals that interact with the surface after implantation in order to quickly regenerate bone in contact with dental implants with mineral coating. A new generation of calcium phosphate coatings applied on the titanium surfaces of dental implants using laser, plasma-sprayed, laser-ablation, or electrochemical deposition processes produces that response. However, these modifications produce failures and bad responses in long-term behavior. Calcium phosphates films result in heterogeneous degradation due to the lack of crystallinity of the phosphates with a fast dissolution; conversely, the film presents cracks, which produce fractures in the coating. New thermochemical treatments have been developed to obtain biomimetic surfaces with calcium phosphate compounds that overcome the aforementioned problems. Among them, the chemical modification using biomineralization treatments has been extended to other materials, including composites, bioceramics, biopolymers, peptides, organic molecules, and other metallic materials, showing the potential for growing a calcium phosphate layer under biomimetic conditions.

15.
Colloids Surf B Biointerfaces ; 185: 110586, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31644974

RESUMEN

Bacterial infection of orthopaedic implants, often caused by Staphylococcus species, may ultimately lead to implant failure. The development of infection-resistant, osteoblast-compatible biomaterials could represent an effective strategy to prevent bacterial colonization of implants, reducing the need for antibiotics. In this study, the widely used biomaterial titanium was functionalized with BMAP27(1-18), an α-helical cathelicidin antimicrobial peptide that retains potent staphylocidal activity when immobilized on agarose beads. A derivative bearing a short spacer with a free thiol at the N-terminus was coupled to silanized titanium disks via thiol-maleimide chemistry. Tethering was successful, as assessed by Contact angle, Quartz Crystal Microbalance with Dissipation monitoring (QCM-D), and X-ray Photoelectron Spectroscopy (XPS), with an average surface mass density of 456 ng/cm2 and a layer thickness of 3 nm. The functionalized titanium displayed antimicrobial properties against a reference strain of Staphylococcus epidermidis with well-known biofilm forming capability. Reduction of bacterial counts and morphological alterations of adhering bacteria, upon 2 h incubation, indicate a rapid contact-killing effect. The immobilized peptide was not toxic to osteoblasts, which adhered and spread better on functionalized titanium when co-cultured with bacteria, compared to non-coated surfaces. Results suggest that functionalization of titanium with BMAP27(1-18) could be promising for prevention of bacterial colonization in bone graft applications.


Asunto(s)
Antibacterianos/farmacología , Péptidos Catiónicos Antimicrobianos/farmacología , Adhesión Bacteriana/efectos de los fármacos , Materiales Biocompatibles Revestidos/química , Osteoblastos/citología , Staphylococcus epidermidis/crecimiento & desarrollo , Titanio/química , Proliferación Celular , Células Cultivadas , Técnicas de Cocultivo , Humanos , Osteoblastos/efectos de los fármacos , Staphylococcus epidermidis/efectos de los fármacos , Propiedades de Superficie , Catelicidinas
16.
Colloids Surf B Biointerfaces ; 182: 110317, 2019 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-31323450

RESUMEN

Biomaterial-associated infections (BAI) are the major cause of failure of indwelling medical devices. The risk of BAI can end dramatically in the surgical removal of the affected device. Therefore, a major effort must be undertaken to guarantee the permanence of the implant. In this regard, we have developed antimicrobial coatings for tantalum (Ta) implants, using polyhydroxyalkanoates (PHAs) as matrices for carrying an active principle. The dip-coating technique was successfully used for covering solid Ta discs. An original PHA emulsion flow process was developed for the coating of porous Ta structures, specially for the inner surfaces. The complete characterization of the biopolymer coatings, their antibacterial properties, toxicity and biointegration were analyzed. Thus, non-toxic, well-biointegrated homogeneous biopolymer coatings were attained, which showed antibacterial properties. By using biodegradable PHAs, the resulting drug delivery system assured the protection of Ta against bacterial infections for a period of time.


Asunto(s)
Antiinfecciosos/farmacología , Materiales Biocompatibles Revestidos/farmacología , Polihidroxialcanoatos/farmacología , Prótesis e Implantes , Tantalio/química , Antiinfecciosos/química , Adhesión Celular/efectos de los fármacos , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Materiales Biocompatibles Revestidos/química , Escherichia coli/efectos de los fármacos , Escherichia coli/crecimiento & desarrollo , Humanos , Pruebas de Sensibilidad Microbiana , Osteoblastos/citología , Osteoblastos/efectos de los fármacos , Polihidroxialcanoatos/química , Porosidad , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/crecimiento & desarrollo
17.
Materials (Basel) ; 12(22)2019 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-31726659

RESUMEN

Sixty-four fractured commercially pure titanium (cp-Ti) narrow dental implants (NDIs) with similar macrogeometry and connection designs were studied after different implantation times in humans in order to determine their reliability and to evaluate the causes of the fracture. These NDIs were compared with other similar implants, made with alloyed titanium with 15% Zr and with 12% strained titanium. Original implants were tested under static and fatigue conditions, simulating the tri-axial loads in the mouth by means of a Bionix hydraulic test machine. Fractography was studied using field-emission scanning electron microscopy (FSEM). The results showed that cp-Ti NDI exhibits low strength for mechanical cycling, and the alloyed Ti and strained titanium increase the mechanical strength, guaranteeing long term mechanical behavior. NDIs fractured due to fatigue, and, in some cases, the presence of cracks in the original NDIs quickly led to fracture. These cracks were attributed to plastic deformation during machining were found to be exacerbated due to acid etching in the passivation process. All cases of fracture were cp-Ti dental implants due to the low fatigue limit. The results show that, when titanium is alloyed or cold-worked, the fatigue limit is higher than cp-Ti. This in vitro research will help clinicians to select a better NDI system for safer treatment.

18.
Materials (Basel) ; 12(6)2019 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-30934553

RESUMEN

The load transfer from metallic prosthesis to tissue plays an important role in the success of a designed device. From a mechanical behavior point of view, the load transfer will be favored when the elastic modulus between the metallic implant and the bone tissue are similar. Titanium and Ti-6Al-4V are the most commonly used metals and alloys in the field of dental implants, although they present high elastic moduli and hence trigger bone resorption. We propose the use of low-modulus ß-type titanium alloys that can improve the growth of new bone surrounding the implant. We designed dental implants with identical morphology and micro-roughness composed of: Ti-15Zr, Ti-19.1Nb-8.8Zr, Ti-41.2Nb-6.1Zr, and Ti-25Hf-25Ta. The commercially pure Ti cp and Ti-6Al-4V were used as control samples. The alloys were initially mechanically characterized with a tensile test using a universal testing machine. The results showed the lowest elastic modulus for the Ti-25Hf-25Ta alloy. We implanted a total of six implants in the mandible (3) and maxilla (3) for each titanium alloy in six minipigs and evaluated their bone index contact (i.e., the percentage of new bone in contact with the metal-BIC%) after 3 and 6 weeks of implantation. The results showed higher BIC% for the dental implants with lowest elastic modulus, showing the importance of decreasing the elastic modulus of alloys for the successful osseointegration of dental implants.

19.
ACS Appl Mater Interfaces ; 9(26): 21618-21630, 2017 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-28594999

RESUMEN

In dentistry and orthopedics, it is well accepted that implant fixation is a major goal. However, an emerging concern is bacterial infection. Infection of metallic implants can be catastrophic and significantly reduce patient quality of life. Accordingly, in this work, we focus on multifunctional coatings to simultaneously address and mitigate both these problems. We have developed a tailor-made peptide-based chemical platform that integrates the well-known RGD cell adhesive sequence and the lactoferrin-derived LF1-11 antimicrobial peptide. The platform was covalently grafted on titanium via silanization and the functionalization process characterized by contact angle, XPS, and QCM-D. The presence of the platform statistically improved the adhesion, proliferation and mineralization of osteoblast-like cells compared to control surfaces. At the same time, colonization by representative bacterial strains was significantly reduced on the surfaces. Furthermore, the biological potency of the multifunctional platform was verified in a co-culture in vitro model. Our findings demonstrate that this multifunctional approach can be useful to functionalize biomaterials to both improve cell integration and reduce the risk of bacterial infection.


Asunto(s)
Materiales Biocompatibles/química , Adhesión Celular , Osteoblastos , Calidad de Vida , Propiedades de Superficie , Titanio
20.
J Biomed Mater Res A ; 105(4): 973-983, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28000367

RESUMEN

Immobilization of bioactive peptide sequences on CoCr surfaces is an effective route to improve endothelialization, which is of great interest for cardiovascular stents. In this work, we explored the effect of physical and covalent immoblization of RGDS, YIGSR and their equimolar combination peptides on endothelial cells (EC) and smooth muscle cell (SMC) adhesion and on thrombogenicity. We extensively investigated using RT-qPCR, the expression by ECs cultured on functionalised CoCr surfaces of different genes. Genes relevant for adhesion (ICAM-1 and VCAM-1), vascularization (VEGFA, VEGFR-1 and VEGFR-2) and anti-thrombogenicity (tPA and eNOS) were over-expressed in the ECs grown to covalently functionalized CoCr surfaces compared to physisorbed and control surfaces. Pro-thrombogenic genes expression (PAI-1 and vWF) decreased over time. Cell co-cultures of ECs/SMCs found that functionalization increased the amount of adhered ECs onto modified surfaces compared to plain CoCr, independently of the used peptide and the strategy of immobilization. SMCs adhered less compared to ECs in all surfaces. All studied peptides showed a lower platelet cell adhesion compared to TCPS. Covalent functionalization of CoCr surfaces with an equimolar combination of RGDS and YIGSR represented prevailing strategy to enhance the early stages of ECs adhesion and proliferation, while preventing SMCs and platelet adhesion. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 973-983, 2017.


Asunto(s)
Aleaciones de Cromo/química , Materiales Biocompatibles Revestidos/química , Oclusión de Injerto Vascular/prevención & control , Células Endoteliales de la Vena Umbilical Humana/metabolismo , Oligopéptidos/química , Trombosis/prevención & control , Plaquetas/metabolismo , Oclusión de Injerto Vascular/metabolismo , Humanos , Trombosis/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA