Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Int Endod J ; 57(1): 23-36, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37974453

RESUMEN

AIM: Several factors influence the condition of the periapical tissues associated with root filled teeth. The primary objective of this study was to retrospectively evaluate the extent and speed of bone healing of large periapical lesions associated with nonsurgical root canal treatment or retreatment. The secondary objective was to analyse the relationship between the time to complete healing when analysed using cone beam computed tomography (CBCT) and other possible predictors that affect healing. METHODOLOGY: Seventy-nine patients were treated during the years 2013-2020 with large periapical lesions of endodontic origin (10-15 mm) as observed on intraoral periapical radiographs (IOPAR) were included. IOPAR and CBCT were available before treatment and during the follow-up (IOPAR every 6 months and CBCT every 12 months). The volume of periapical lesions was calculated by OsiriX Lite software. Variables such as initial volume of the lesion, age, gender, type of treatment or type of root canal filling were compared to identify the differences between healed and unhealed lesions. Pearson's Chi-square test was used for categorical variables, the t-test for age and the Wilcoxon test for initial volume of the lesion. The association between time to healing and the variables was assessed using univariate analysis and multivariate analysis. The Wilcoxon test was used to observe the association of healing time with categorical variables and the correlation index was measured with the quantitative variables. RESULTS: Of the 79 cases analysed, 60 lesions (76%) were completely healed as verified by CBCT in a mean healing time of 19 months, of which 60% healed fully between 12 and 18 months. Increase in age of patient and larger initial volume of the lesion were associated with a significantly longer healing time (p < .001). Gender, filling material and type of treatment did not have a significant effect on the healing process (p > .05). CONCLUSIONS: Clinicians should be aware that periapical lesions in older patients and larger areas of bone loss take longer to heal. CBCT monitoring of large periapical lesions is critical and it can help clinicians in the decision-making process.


Asunto(s)
Cavidad Pulpar , Periodontitis Periapical , Humanos , Anciano , Estudios Retrospectivos , Tratamiento del Conducto Radicular/métodos , Retratamiento , Tomografía Computarizada de Haz Cónico/métodos , Periodontitis Periapical/terapia , Periodontitis Periapical/cirugía
2.
BMC Oral Health ; 24(1): 753, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38951790

RESUMEN

BACKGROUND: Gutta-percha (GP) combined with an endodontic sealer is still the core material most widely used for tridimensional obturation. The sealer acts as a bonding agent between the GP and the root dentinal walls. However, one of the main drawbacks of GP core material is the lack of adhesiveness to the sealer. ZnO thin films have many remarkable features due to their considerable bond strength, good optical quality, and excellent piezoelectric, antibacterial, and antifungal properties, offering many potential applications in various fields. This study aimed to explore the influence of GP surface's functionalization with a nanostructured ZnO thin film on its adhesiveness to endodontic sealers. METHODS: Conventional GP samples were divided randomly into three groups: (a) Untreated GP (control); (b) GP treated with argon plasma (PT); (c) Functionalized GP (PT followed by ZnO thin film deposition). GP's surface functionalization encompassed a multi-step process. First, a low-pressure argon PT was applied to modify the GP surface, followed by a ZnO thin film deposition via magnetron sputtering. The surface morphology was assessed using SEM and water contact angle analysis. Further comprehensive testing included tensile bond strength assessment evaluating Endoresin and AH Plus Bioceramic sealers' adhesion to GP. ANOVA procedures were used for data statistical analysis. RESULTS: The ZnO thin film reproduced the underlying surface topography produced by PT. ZnO thin film deposition decreased the water contact angle compared to the control (p < 0.001). Endoresin showed a statistically higher mean bond strength value than AH Plus Bioceramic (p < 0.001). There was a statistically significant difference between the control and the ZnO-functionalized GP (p = 0.006), with the latter presenting the highest mean bond strength value. CONCLUSIONS: The deposition of a nanostructured ZnO thin film on GP surface induced a shift towards hydrophilicity and an increased GP's adhesion to Endoresin and AH Bioceramic sealers.


Asunto(s)
Recubrimiento Dental Adhesivo , Gutapercha , Nanoestructuras , Materiales de Obturación del Conducto Radicular , Propiedades de Superficie , Óxido de Zinc , Óxido de Zinc/química , Materiales de Obturación del Conducto Radicular/química , Nanoestructuras/química , Gutapercha/química , Recubrimiento Dental Adhesivo/métodos , Humanos , Ensayo de Materiales , Adhesividad , Microscopía Electrónica de Rastreo , Resistencia a la Tracción
3.
Int J Paediatr Dent ; 33(5): 521-534, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37350350

RESUMEN

BACKGROUND: Regenerative endodontics (RET) refers to biologically based procedures that aim to restore damaged tooth structures and reinstate the pulp-dentine complex to its normal physiological state. AIM: The purpose of this study was to examine the attitudes and practices of endodontists and paediatric dentists regarding RET. DESIGN: A survey was conducted among endodontists and paediatric dentists from 13 countries. A number of factors were evaluated, including frequency of RET application, followed guidelines, disinfection techniques, intracanal medication type, scaffold type, preferred coronal seal material, and follow-up period. RESULTS: Among the 1394 respondents, 853 (61.2%) and 541 (38.8%) were endodontists and paediatric dentists, respectively. Almost half (43%) of participants have not performed RET yet. The American Association of Endodontics guideline (47.3%) was selected as the primary source for the clinical protocol. The most frequently selected irrigant solution was 1.5%-3% NaOCl at the first (26.1%) and second (13.6%) sessions. A blood clot (68.7%) and MTA (61.9%) were the most frequently selected scaffold type and coronal barrier. Most participants preferred a 6-month follow-up period. CONCLUSION: According to this survey, deviations exist from current RET guidelines regarding all aspects evaluated. Standardizing clinical protocols and adhering to available guidelines would help to ensure more predictable outcomes.


Asunto(s)
Endodoncistas , Endodoncia Regenerativa , Niño , Humanos , Odontólogos , Actitud , Encuestas y Cuestionarios , Pautas de la Práctica en Odontología
4.
Medicina (Kaunas) ; 58(6)2022 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-35743982

RESUMEN

Clinicians should be aware of all the characteristics and capacities of the instruments that are possible to use when conducting a root canal treatment. The wide variety of nickel-titanium (Ni-Ti) rotary systems on the market and the lack of standardisation of this type of instrument makes the choice in each specific case difficult. Therefore, this review is intended to summarize the characteristics that should be taken into account when choosing one instrument over another. It will be essential to know characteristics, of alloy from which the instrument is made. Moreover, the geometry of the instrument will determine its behaviour, being the mass, the one that marks its resistance to a greater extent. The movement performed by the file is another of the fundamental keys to understand rotary instruments. In conclusion, when performing root canal treatment, the characteristics of the instrument and the tooth must be taken into account, and the operator's own limitations should be known. This paper provides the key points to keep in mind when making this type of treatment.


Asunto(s)
Endodoncistas , Preparación del Conducto Radicular , Diseño de Equipo , Humanos , Titanio
5.
Clin Oral Investig ; 25(10): 5743-5753, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33855658

RESUMEN

OBJECTIVE: Subgingival dental restorations and periodontal health have been studied for many years; however, there is a low histological evidence on the behavior of new materials in the supracrestal tissue attachment. The aim of this study is to analyze the periodontal response when a tricalcium silicate material (TSM) or composite margin restorations is placed to 0.5 mm and 1.5 mm from the bone crest with a histomorphometric analysis in dogs. METHODS: Nine mongrel dogs were used in this study: four dogs (8 canine teeth) for TSM group, 4 dogs (8 canine teeth) for composite group, and 1 dog (2 canine teeth) with cavities without restorations. Cavity preparation of 2×2×1 mm was created on the buccal aspect of the canines at 0.5 and 1.5 mm of the crestal bone. Cavities were restored with composite and TSM or were left unrestored as control. After 12 weeks of healing, the dogs were euthanized and blocks containing the tooth and soft tissues were processed. RESULTS: In all the specimens, the junction epithelium was stablished apical to the tooth preparations. A shorter distance to the bone (0.5 cavity) implies greater apical periodontal migration regardless of the material used. In the TSM groups, the connective tissue height and the distance between bone level and apical margin preparation were greater than those in the composite groups, while the epithelium height was less. However, there were no statistically significant differences comparing TSM and composite groups at either 0.5 mm or 1.5 mm (p > 0.05). CONCLUSION: Histologic analysis did not show periodontal reattachment to TSM or composite. In both cases, bone crest migrates apically. For that reason, it is recommended to perform composite restorations at the subgingival level whenever the distance to the bone crest is at least 2 mm. CLINICAL RELEVANCE: Both composite and TSM do not achieve reinsertion of the connective tissue in the biological width.


Asunto(s)
Resinas Compuestas , Caries Dental , Animales , Compuestos de Calcio , Preparación de la Cavidad Dental , Perros , Inserción Epitelial , Silicatos
6.
J Prosthet Dent ; 121(4): 553-556, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30878148

RESUMEN

Surgical extrusion should be considered as an alternative treatment in patients with structurally compromised teeth that retain coronal integrity and have favorable root anatomy. The procedure described is straightforward and can be performed quickly. A situation in which it was used to treat a maxillary premolar with substantial structural loss but well-preserved periodontal attachment is presented. The biologically oriented preparation technique is a conservative method of tooth restoration.


Asunto(s)
Fracturas de los Dientes , Raíz del Diente , Diente Premolar , Humanos
7.
BMC Oral Health ; 14: 160, 2014 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-25540020

RESUMEN

BACKGROUND: Age determination has great importance in many clinical decisions, being commonly used in odontopediatrics, orthodontics, pediatrics, and forensic medicine. The Nolla and Demirjian et al. methods have been used for these purposes. However, estimating chronological age by means of the dental mineralization stage is not a straightforward analysis, and it is fundamental to test the validity of these methods and their applicability to populations. In this article we intend to compare the accuracy of estimating chronological age from dental age measured with the Nolla and Demirjian methods in a Portuguese and Spanish sample, considering the variables of sex and age-group. METHODS: The sample was composed of 821 orthopantomographs of healthy Portuguese (n = 270) and Spanish (n = 551) subjects from 4 to 34 years old. For the Nolla and Demirjian methods, seven mandibular left teeth were examined, staged according to the dental maturity scale of each method. We obtained a good index of inter-rater agreement, a good internal consistency for the teeth assessment, and a good temporal consistency. RESULTS: Dental age was calculated for each method. The Demirjian et al. method tends to overestimate the real age of participants and the Nolla method tends to underestimate it. The accuracy of both methods varied between the sexes and age groups. Both methods were found to be more precise with males. As the age-group increases, the predictive capacities of both methods diminish. The Nolla method was more accurate than the Demirjian method in early and late childhood for both sexes. Neither method could predict chronological age in adults. CONCLUSIONS: We can estimate chronological age for early and late childhood, through the Nolla and Demirjian methods, with the former showing greater predictive capacities than the latter. The Demirjian method tends to overestimate age and the Nolla method tends to underestimate it, leading to the importance of forming regression equations adapted to the population studied. Nolla and Demirjian formulas adapted to our sample were created as a function of sex and age-group.


Asunto(s)
Determinación de la Edad por los Dientes/métodos , Adolescente , Adulto , Factores de Edad , Niño , Preescolar , Femenino , Predicción , Humanos , Masculino , Portugal , Valor Predictivo de las Pruebas , Radiografía Panorámica , Factores Sexuales , España , Calcificación de Dientes/fisiología , Adulto Joven
8.
Anat Rec (Hoboken) ; 307(5): 1960-1968, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37975162

RESUMEN

PIEZO1 and PIEZO2 are essential components of mechanogated ion channels, which are required for mechanotransduction and biological processes associated with mechanical stimuli. There is evidence for the presence of PIEZO1 and PIEZO2 in teeth and periodontal ligaments, especially in cell lines and mice, but human studies are almost nonexistent. Decalcified permanent human teeth and mouse molars were processed for immunohistochemical detection of PIEZO1 and PIEZO2. Confocal laser microscopy was used to examine the co-localization of PIEZO 1 and PIEZO2 with vimentin (a marker of differentiated odontoblasts) in human teeth. In the outer layer of the human dental pulp, abundant PIEZO1- and PIEZO2-positive cells were found that had no odontoblast morphology and were vimentin-negative. Based on their morphology, location, and the absence of vimentin positivity, they were identified as dental pulp stem cells or pre-odontoblasts. However, in mice, PIEZO1 and PIEZO2 were ubiquitously detected and colocalized in odontoblasts. Intense immunoreactivity of PIEZO1 and PIEZO2 has been observed in human and murine periodontal ligaments. Our findings suggest that PIEZO1 and PIEZO2 may be mechanosensors/mechanotransducers in murine odontoblasts, as well as in the transmission of forces by the periodontal ligament in humans and mice.


Asunto(s)
Mecanotransducción Celular , Ligamento Periodontal , Humanos , Ratones , Animales , Ligamento Periodontal/metabolismo , Vimentina/metabolismo , Pulpa Dental , Canales Iónicos/metabolismo
9.
Materials (Basel) ; 17(8)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38673256

RESUMEN

This study aimed to describe a support material removal protocol (SMRP) from inside the root canals of three-dimensional printed teeth (3DPT) obtained by the microcomputed tomography (microCT) of a natural tooth (NT), evaluate its effectiveness by comparing the 3DPT to NT in terms of internal anatomy and behaviour toward endodontic preparation, and evaluate if 3DPT are adequate to assess the differences between two preparation systems. After the SMRP, twenty 3DPT printed by PolyJet™ were microCT scanned before preparation and thereafter randomly assigned into two groups (n = 10). One group and NT were prepared using ProTaper Gold® (PTG), and the other group with Endogal® (ENDG). MicroCT scans were carried out after preparation, and the volume increase, volume of dentin removed, centroids, transportation, and unprepared areas were compared. For the parameters evaluated, no significant differences were found between the 3DPT and NT before and after preparation (p > 0.05), and no significant differences were found between the 3DPT PTG group and the 3DPT ENDG group (p > 0.05). It can be concluded that the SMRP described is effective in removing the support material SUP706B™. PolyJet™ is adequate for printing 3DPT. Furthermore, 3DPT printed with high-temperature RGD525™ have similar behaviour during endodontic preparation with PTG as the NT, and 3DPT can be used to compare two preparation systems.

10.
Dent J (Basel) ; 12(4)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38668007

RESUMEN

The dental pulp chamber volume is a fundamental measurement in the field of endodontics, but also in forensic sciences, teaching and training, or tissue engineering. This study evaluates the precision of cone-beam computed tomography (CBCT) in comparison with computed micro-tomography (micro-CT) in evaluating the pulp chamber volume of the upper central incisors ex vivo. The intra-operator and inter-operator errors were evaluated, and the results for the two techniques were compared with those of a T-test for paired samples. The intra-operator and inter-operator errors were >0.05, indicating adequate reproducibility in each operator and no significant differences between their measurements. On the other hand, no significant differences between the two measurement techniques were found. The present results demonstrate that CBCT is a precise, feasible, and reproducible technique for the evaluation of the dental pulp chamber volume ex vivo. The results provided with this method are useful for different medical domains but also for the teaching and training of undergraduate and postgraduate students. Furthermore, the findings of this study carry significant clinical implications, as the accurate assessment of the pulp chamber volume is critical in the diagnosis and treatment of various endodontic conditions. The ability of CBCT to provide reliable 3D dental anatomy measurements can enhance the planning of endodontic treatments by allowing for a better understanding of the internal tooth morphology. Additionally, the precision and reproducibility of CBCT in assessing the pulp chamber volume can contribute to improved clinical outcomes and reduced complications during endodontic procedures. These findings further support the increasingly vital role of CBCT in modern clinical practice and underscore its value as an indispensable tool in the field of dentistry.

11.
Materials (Basel) ; 17(6)2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38541586

RESUMEN

The aim of this study is to analyze the effects of different endodontic irrigants and adhesive systems on the resin bond strength of fiber post cementation. In total, 144 single-rooted, unrestored human teeth were endodontically treated and randomly divided into 12 groups according to four endodontic irrigants (distilled water as control; EDTA 17%; NaOCl 5%; chlorhexidine digluconate 2%) and three different adhesive/resin cement systems (etch-and-rinse: orthophosphoric acid, Parabond® A+B/Paracore®; self-etch: ParaBond® Non-Rinse Conditioner, Parabond® A+B/Paracore®; Universal: ClearfilTM Universal Bond/ClearfilTM DC Core Plus). Forty-eight hours after post cementation, ten teeth from each group were cross-sectioned into three discs (cervical, middle and apical regions). Thirty specimens of each group (n = 30) were submitted to a push-out test at a crosshead speed of 1 mm/min. The remaining two teeth of each group were sectioned in the same manner, and the resin-dentin interface was evaluated using scanning electron microscopy (SEM). The results were statistically analyzed with the ANOVA test and Tukey's test (p < 0,01). The adhesive protocols and post space region showed no significant effect on bond strength (p > 0.01). The combination of NaOCl 5% and ClearfilTM Universal Bond reduced the adhesive strength (p < 0.01). The NaOCl 5%, in relation to other irrigants, significantly decreased the push-out bond strength.

12.
J Am Dent Assoc ; 155(7): 614-623.e2, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38795077

RESUMEN

BACKGROUND: This retrospective clinical study aimed to compare the sensitivity of cone-beam computed tomographic (CBCT) images and periapical (PA) radiographs to reveal cracked teeth, split teeth, and teeth with vertical root fractures (VRFs). METHODS: The authors included 98 patients (98 teeth) diagnosed with a longitudinal tooth fracture (LTF) (cracked tooth, split tooth, VRF) through direct visualization after extraction and with comprehensive clinical and radiographic records. They collected demographic, clinical, and radiographic data. The authors evaluated PA radiographs and CBCT images to identify fractures, fracture lines, and the different patterns of bone loss associated with these teeth. They used the McNemar test to compare PA radiographs and CBCT scans when assessing bone loss. They used the Fisher test to determine statistical relationships between fracture types and demographic, clinical, and radiologic traits. They used an analysis of variance test to compare patient age with fracture types. RESULTS: CBCT images were significantly more effective (P < .05) in detecting bone loss patterns associated with LTFs than with PA radiographs, with 71% of cases detected via CBCT images compared with 42% via radiographs. Mean age was significantly greater (P < .05) in patients with teeth with VRFs than in patients with split teeth. A significant relationship was observed between the type of fracture and the following variables: root canal treatment (split, VRF, P = .002), deep probing depth (≥ 5 mm) (VRF, P = .026), and having more than 8 teeth extracted from the mouth (VRF, P = .032). Overall, there was a significant difference (P < .001) between the visualization of fracture lines (45% on PA radiographs, 65% on CBCT images). CONCLUSIONS: CBCT scans provided more information on LTFs than PA radiographs, particularly in the identification of periradicular bone changes. PRACTICAL IMPLICATIONS: CBCT imaging can assist in making the clinical diagnosis of LTFs through observation of bone loss patterns, providing more information than PA radiographs.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Fracturas de los Dientes , Raíz del Diente , Humanos , Tomografía Computarizada de Haz Cónico/métodos , Estudios Retrospectivos , Fracturas de los Dientes/diagnóstico por imagen , Femenino , Masculino , Persona de Mediana Edad , Raíz del Diente/diagnóstico por imagen , Raíz del Diente/lesiones , Adulto , Anciano , Pérdida de Hueso Alveolar/diagnóstico por imagen , Síndrome de Diente Fisurado/diagnóstico por imagen , Radiografía Dental/métodos , Adulto Joven , Sensibilidad y Especificidad , Factores de Edad , Radiografía de Mordida Lateral/métodos , Adolescente
13.
J Dent ; 148: 105096, 2024 09.
Artículo en Inglés | MEDLINE | ID: mdl-38796090

RESUMEN

OBJECTIVES: When dental practitioners encounter a defective restoration, they are faced with a crucial decision whether to repair or replace it. This study aims to explore international preferences for repair procedures and the clinical steps taken during the repair process. METHOD: An 11-question survey was distributed to dentists across 21 countries via different platforms. The survey comprised two sections: the first included five questions aimed at gathering demographic information, while the second consisted of six questions focusing on participants' practices related to the repair of composite or amalgam restorations A meta-analysis was employed to ascertain the pooled odds ratio of repairing versus replacement. The statistical analysis was carried out using the RevMan 5.3 program and forest plots were generated using the same program to visualize the results. RESULTS: The survey was completed by 3680 dental practitioners. The results indicated a strong tendency to repair defective composite restorations (OR: 14.23; 95 % CI: 7.40, 27.35, p < 0.001). In terms of amalgam, there was a significant tendency to replace the restorations (OR: 0.19; 95 % CI: 0.12, 0.30, p < 0.001). When repairing restorations, the most common protocols were etching with orthophosphoric acid and creating an enamel bevel, regardless of the restorative material used. CONCLUSION: The findings of this study indicate that there exists a knowledge gap among dental practitioners regarding restoration repair. It is imperative that dental practitioners receive proper education and training on restoration repair, to ensure the usage of adequate protocols and restoration survival. CLINICAL SIGNIFICANCE: A significant portion of dental practitioners lack the necessary knowledge and education required for the repair of restorations. Therefore, it is imperative to establish guidelines aimed at enhancing the management of defective restorations, along with protocols for clinical interventions. This includes the incorporation of proper courses in undergraduate, graduate, and continuing education programs.


Asunto(s)
Resinas Compuestas , Amalgama Dental , Reparación de Restauración Dental , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Estudios Transversales , Resinas Compuestas/química , Encuestas y Cuestionarios , Pautas de la Práctica en Odontología/estadística & datos numéricos , Fracaso de la Restauración Dental , Odontólogos , Masculino , Femenino , Adulto
14.
J Clin Exp Dent ; 15(7): e590-e593, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37519324

RESUMEN

The BOPT technique (Biologically Oriented Preparation Technique) was proposed by Loi et al. (1) and has become a popular form of vertical preparation for complete crowns with promising results. In this procedure, the clinician can operate on the gingival tissue during preparation and modify its structure in thickness and height by adding modifications on the provisional restoration. However, one of the main challenges in this technique is the transference of information about the gingival tissue to the laboratory technician, who will place the margin of the restoration randomly in a space determined by two marks on the working cast. The technique proposed enables the accurate transmission of the exact point where the margin of the restoration needs to be placed. Furthermore, it facilitates the recording of conventional impression materials and intraoral scanners due to the compression of polytetrafluoroethylene (PTFE) tape into the sulcus, which allows to arrest bleeding or intracrevicular liquid and is easily registered irrespective of the method of impression used. Key words:Vertical preparation, BOPT, PTFE, emergence profile, digital impression, conventional impression.

15.
Aust Endod J ; 49 Suppl 1: 481-487, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37154212

RESUMEN

Dens Invaginatus (DI) or dens in dente is an uncommon anomaly which mostly affects permanent lateral incisors, and it is very rare in molars. This article presents the conservative endodontic management of four different cases of DI and a discussion of the endodontic literature for this malformation. Three upper lateral incisors Type II, IIIa and IIIb, and an upper first molar Type II are shown. The most conservative approach possible was carried out. Three of the cases were obturated using the continuous wave technique. In one of the cases, it was possible to treat only the invagination with MTA and preserve the pulp vitality of the main canal. To make a correct diagnosis and to treat in the most conservative way possible, a DI is necessary to know its classification and use tools such as CBCT and magnification.


Asunto(s)
Dens in Dente , Materiales de Obturación del Conducto Radicular , Humanos , Tratamiento del Conducto Radicular/métodos , Materiales de Obturación del Conducto Radicular/uso terapéutico , Dens in Dente/diagnóstico por imagen , Dens in Dente/terapia , Tratamiento Conservador , Estudios de Seguimiento
16.
Sci Rep ; 13(1): 12303, 2023 07 29.
Artículo en Inglés | MEDLINE | ID: mdl-37516768

RESUMEN

Gutta-percha's lack of adhesion has been presented as a drawback to avoid gaps at sealer/gutta-percha interface. Plasma treatments have been scarcely assessed on gutta-percha surfaces as a method of enhancing adhesiveness. This study aimed to evaluate the effect of low-pressure Argon and Oxygen plasma atmospheres on conventional and bioceramic gutta-percha standardized smooth discs, assessing their roughness, surface free energy, chemical structure, and sealer wettability. A Low-Pressure Plasma Cleaner by Diener Electronic (Zepto Model) was used. Different gases (Argon or Oxygen), powers (25 W, or 50 W), and exposure times (30 s, 60 s, 120 s, or 180 s) were tested in control and experimental groups. Kruskal-Wallis and Student's t-test were used in data analysis. Statistically significant differences were detected when P < 0.05. Both gases showed different behaviors according to the parameters selected. Even though chemical changes were detected, the basic molecular structure was maintained. Argon or Oxygen plasma treatments favoured the wetting of conventional and bioceramic gutta-perchas by Endoresin and AH Plus Bioceramic sealers (P < 0.001). Overall, the functionalization of gutta-percha surfaces with Argon or Oxygen plasma treatments can increase roughness, surface free energy and wettability, which might improve its adhesive properties when compared to non-treated gutta-percha.


Asunto(s)
Gases , Gutapercha , Humanos , Adhesividad , Argón , Oxígeno
17.
J Endod ; 49(6): 675-685, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37094712

RESUMEN

INTRODUCTION: Direct pulp capping (DPC) procedures require the placement of a bioactive material over an exposure site without selective pulp tissue removal. This web-based multicentered survey had 3 purposes: (1) to investigate the factors that affect clinicians' decisions in DPC cases, (2) to determine which method of caries removal is preferred, and (3) to evaluate the preferred capping material for DPC. METHODS: The questionnaire comprised 3 sections. The first part comprised questions regarding demographic features. The second part comprised questions on how treatment plans change according to factors such as nature, location, number and size of the pulp exposure, and patients' age. The third part composed of questions on the common materials and techniques used in DPC. To estimate the effect size, the risk ratio (RR) and 95% confidence interval (CI) were calculated using a meta-analysis software. RESULTS: A tendency toward more invasive treatment was observed for the clinical scenario with carious-exposed pulp (RR = 2.86, 95% CI: 2.46, 2.32; P < .001) as opposed to the clinical scenario with 2 pulp exposures (RR = 1.38, 95% CI: 1.24, 1.53; P < .001). Complete caries removal was significantly preferred to selective caries removal (RR = 4.59, 95% CI: 3.70, 5.69; P < .001). Among the capping materials, calcium silicate-based materials were preferred over calcium hydroxide-based materials (RR = 0.58, 95% CI: 0.44, 0.76; P < .05). CONCLUSIONS: While carious-exposed pulp is the most important factor in clinical decisions regarding DPC, the number of exposures has the least impact. Overall, complete caries removal was preferred over selective caries removal. In addition, the use of calcium silicate-based materials appears to have replaced calcium hydroxide-based materials.


Asunto(s)
Caries Dental , Materiales de Recubrimiento Pulpar y Pulpectomía , Humanos , Hidróxido de Calcio/uso terapéutico , Recubrimiento de la Pulpa Dental/métodos , Odontólogos , Rol Profesional , Compuestos de Calcio/uso terapéutico , Silicatos/uso terapéutico , Pulpa Dental , Caries Dental/terapia , Encuestas y Cuestionarios , Materiales de Recubrimiento Pulpar y Pulpectomía/uso terapéutico
18.
Artículo en Inglés | MEDLINE | ID: mdl-36232005

RESUMEN

Estimation of children's chronological age is highly important in human and forensic sciences. The Demirjian method has been reported as accurate for this purpose. The literature review shows some evidence that the accuracy of estimating chronological age via the Demirjian standards is not a straightforward process. The objective of this research is to analyze the reliability of the Demirjian standards in Portuguese and Spanish children and adolescents and adapt it to include sex and group age as contingent factors. METHODS: Orthopantomographs of 574 Portuguese and Spanish male and female children and adolescents were employed to test the reliability of the Demirjian method. After testing for inter-rater consistency and age estimation using the Demirjian standards, multiple regression analysis was performed controlling for sex and age group. RESULTS: The Demirjian standards overestimated chronological age for both sexes, mainly for females. Through the development of regression functions, more detailed dental age estimation was performed. The predictive capacities of the Demirjian method and the significant teeth varied as a function of children's age. The Demirjian global standard predicted over 65% of the variance of the chronological age. Taking a tooth-by-tooth approach, the predictive ability increased by over 70%. CONCLUSIONS: The accuracy of estimating chronological age via the Demirjian method is not as reliable as it might appear, judging from the results found according to age group and according to sex crossed with age group.


Asunto(s)
Determinación de la Edad por los Dientes , Diente , Adolescente , Determinación de la Edad por los Dientes/métodos , Niño , Femenino , Humanos , Masculino , Portugal , Radiografía Panorámica/métodos , Reproducibilidad de los Resultados
19.
J Clin Med ; 11(11)2022 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-35683530

RESUMEN

The present study aims to evaluate and contrast the function of the rotational speed of NiTi alloy endodontic rotary files on how resistant they are to dynamic cyclic fatigue. Methods: A total of 150 NiTi alloy endodontic rotary files with similar geometrical design and metallurgical properties were randomly divided into study groups: Group A: 200 rpm (n = 30); Group B: 350 rpm (n = 30); Group C: 500 rpm (n = 30); Group D: reciprocating movement at 350 rpm with 120° counterclockwise and 30° clockwise motion (350 rpm+) (n = 30); and Group E: reciprocating movement at 400 rpm with 120° counterclockwise and 30° clockwise motion (400 rpm+) (n = 30). A dynamic device was designed to carry out dynamic cyclic fatigue tests using artificial root canal systems made from stainless steel with an apical diameter of 250 µm, 5 mm radius of curvature, 60° curvature angle, and 6% taper, and 20 mm in length. A Weibull statistical analysis and ANOVA test were used to analyze the results. Results: The ANOVA analysis showed differences in time to failure among all the study groups that were of statistical significance (p < 0.001). Conclusions: NiTi alloy endodontic rotary files using reciprocating movement at 350 rpm with 120° counterclockwise and 30° clockwise motion exhibit greater resistance to dynamic cyclic fatigue than files used with a reciprocating movement at 400 rpm with 120° counterclockwise and 30° clockwise motion, continuous rotational speed at 200 rpm, continuous rotational speed at 350 rpm, or continuous rotational speed at 500 rpm; it is therefore advisable to use reciprocating movements at a low speed.

20.
Artículo en Inglés | MEDLINE | ID: mdl-35805624

RESUMEN

Three-dimensional printing offers possibilities for the development of new models in endodontics. Numerous studies have used 3D-printed teeth; however, protocols for the standardization of studies still need to be developed. Another problem with 3D-printed teeth is the different areas of literature requested to understand the processes. This review aims to gather evidence about 3D-printed teeth on the following aspects: (1) why they are advantageous; (2) how they are manufactured; (3) problems they present; and (4) future research topics. Natural teeth are still the standard practice in ex vivo studies and pre-clinical courses, but they have several drawbacks. Printed teeth may overcome all limitations of natural teeth. Printing technology relies on 3D data and post-processing tools to form a 3D model, ultimately generating a prototype using 3D printers. The major concerns with 3D-printed teeth are the resin hardness and printing accuracy of the canal anatomy. Guidance is presented for future studies to solve the problems of 3D-printed teeth and develop well-established protocols, for the standardization of methods to be achieved. In the future, 3D-printed teeth have the possibility to become the gold standard in ex vivo studies and endodontic training.


Asunto(s)
Endodoncia , Diente , Atención Odontológica , Humanos , Impresión Tridimensional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA