Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Arthroplasty ; 39(6): 1545-1549, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38128624

RESUMEN

BACKGROUND: The mode of femoral fixation for primary total hip arthroplasty (THA) is undetermined, with reported outcomes favoring different fixation methods. This study aimed to compare postoperative complications between cemented and cementless fixation at 90 days, 1 year, and 2 years in patients aged 65 years of age and older undergoing THA for osteoarthritis. METHODS: Using an all-payer, national database, patients 65 years and older undergoing primary THA, either with cementless (n = 56,701) or cemented (n = 6,283) femoral fixation for osteoarthritis were identified. A 1:1 propensity-matched analysis for age, sex, comorbidity index, alcohol abuse, tobacco use, obesity, and diabetes was performed, resulting in n = 6,283 patients in each cohort. Postoperative outcomes, including postoperative periprosthetic joint infection, aseptic revision, surgical site infection, pulmonary embolism, venous thromboembolism, wound complications, dislocation, periprosthetic fracture, and aseptic loosening were assessed. RESULTS: The cemented cohort had higher rates of infection (4.5 versus 0.8%, odds ratio [OR] 5.9, 95% confidence interval [CI] 4.33 to 7.93, P < .001), aseptic revision (2.9 versus 2.0%, OR 1.47, 95% CI 1.17 to 1.85, P = .001), venous thromboembolism (1.8 versus 1.3%, OR 1.40, 95% CI 1.05 to 1.87, P < .001), and aseptic loosening (1.5 versus 0.7%, OR 2.31, 95% CI 1.60 to 3.32, P < .001) at 90-days. At 1 and 2 years, the cemented cohort had higher rates of infection, aseptic revision, and aseptic loosening (all P < .001). Rates of periprosthetic fracture were similar at all time points (all P < .001). CONCLUSIONS: Cemented fixation had higher rates of infection, aseptic loosening, and aseptic revision. This finding supports the current use of cementless fixation, but the ultimate decision regarding fixation type should be based on the proper optimization of the patient's comorbidities and bone quality.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Osteoartritis de la Cadera , Complicaciones Posoperatorias , Reoperación , Humanos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Masculino , Anciano , Osteoartritis de la Cadera/cirugía , Reoperación/estadística & datos numéricos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Anciano de 80 o más Años , Prótesis de Cadera/efectos adversos , Falla de Prótesis/etiología , Infecciones Relacionadas con Prótesis/etiología , Fémur/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
2.
J Arthroplasty ; 39(7): 1747-1751, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38253188

RESUMEN

BACKGROUND: Femoral neck fractures are common in individuals over 65, necessitating quick mobilization for the best outcomes. There's ongoing debate about the optimal femoral component fixation method in total hip arthroplasty (THA) for these fractures. Recent U.S. data shows a preference for cementless techniques in over 93% of primary THAs. Nonetheless, cemented fixation might offer advantages like fewer revisions, reduced periprosthetic fractures, lesser thigh pain, and enhanced long-term implant survival for those above 65. This study compares cementless and cemented fixation methods in THA, focusing on postoperative complications in patients aged 65 and older. METHODS: We analyzed a national database to identify patients aged 65+ who underwent primary THA for femoral neck fractures between 2016 and 2021, using either cementless (n = 2,842) or cemented (n = 1,124) techniques. A 1:1 propensity-matched analysis was conducted to balance variables such as age, sex, and comorbidities, resulting in two equally sized groups (n = 1,124 each). We evaluated outcomes like infection, venous thromboembolism (VTE), wound issues, dislocation, periprosthetic fracture, etc., at 90 days, 1 year, and 2 years post-surgery. A P-value < 05 indicated statistical significance. RESULTS: The cemented group initially consisted of older individuals, more females, and higher comorbidity rates. Both groups had similar infection and wound complication rates, and aseptic loosening. The cemented group, however, had lower periprosthetic fracture rates (2.5 versus 4.4%, P = .02) and higher VTE rates (2.9 versus 1.2%, P = .01) at 90 days. After 1 and 2 years, the cementless group experienced more aseptic revision surgeries. CONCLUSIONS: This study, using a large, national database and propensity-matched cohorts, indicates that cemented femoral component fixation in THA leads to fewer periprosthetic fractures and aseptic revisions, but a higher VTE risk. Fixation type choice should consider various factors, including age, sex, comorbidities, bone quality, and surgical expertise. This data can inform surgeons in their decision-making process.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Fracturas del Cuello Femoral , Complicaciones Posoperatorias , Humanos , Artroplastia de Reemplazo de Cadera/métodos , Artroplastia de Reemplazo de Cadera/efectos adversos , Anciano , Femenino , Masculino , Fracturas del Cuello Femoral/cirugía , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/epidemiología , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Resultado del Tratamiento , Prótesis de Cadera/efectos adversos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/efectos adversos
3.
J Arthroplasty ; 39(9): 2363-2367, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38604277

RESUMEN

BACKGROUND: Arthrofibrosis is a debilitating postoperative complication and a major cause of patient dissatisfaction following total knee arthroplasty (TKA). There is no consensus regarding the optimal treatment for stiffness after TKA. For cases not amenable to manipulation under anesthesia (MUA), one component or full revision are both suitable options. In a value-based healthcare era, maximizing cost-effectiveness with optimized clinical outcomes for patients remains the ultimate goal. As such, we compared (1) Knee Injury and Osteoarthritis Outcome Scores for Joint Replacement (KOOS, JR), (2) range of motion (ROM), as well as (3) complication rates, including MUA and lysis of adhesions (LOA), between polyethylene exchange and full component revision for TKA arthrofibrosis. METHODS: Patients were queried from an institutional database who underwent revision TKA for arthrofibrosis between January 1, 2015, and April 31, 2021. There were 33 patients who underwent full revision and 16 patients who underwent polyethylene exchange. Demographics and baseline characteristics between the cohorts were analyzed. Postoperative outcomes included MUA, LOA, and re-revision rates as well as KOOS, JR, and extension and flexion ROM at a mean follow-up of 3.8 years. Baseline comorbidities, including age, body mass index, alcohol use, tobacco use, and diabetes, were comparable between the full revision and polyethylene exchange revision cohorts (P > .05). The one and full component revisions had similar preoperative KOOS, JR (43 versus 42, P = .85), and flexion (81 versus 82 degrees, P = .80) versus extension (11 versus 11 degrees, P = .87) ROM. RESULTS: The full component revision had higher KOOS, JR (65 versus 55, P = .04), and flexion (102 versus 92 degrees, P = .02), but similar extension (3 versus 3 degrees, P = .80) ROM at final follow-up compared to the polyethylene exchange revision, respectively. The MUA (18.2 versus 18.8%, P = .96) and LOA (2.0 versus 0.0%, P = .32) rates were similar between full component and polyethylene exchange revisions. There was one re-revision (3.0%) for the cohort of patients who initially underwent full revision. There were four full re-revisions (25.0%) and two polyethylene exchange re-revisions (12.5%) performed in the cohort of patients who initially underwent a polyethylene exchange revision. CONCLUSIONS: The full component revision for stiffness after TKA showed favorable KOOS, JR, ROM, and outcomes in comparison to the polyethylene exchange revision. While the optimal treatment for stiffness after TKA is without consensus, this study supports the use of the full component revision when applied to the institutional population at hand. It is imperative that homogeneity exists in preoperative definitions, preoperative baseline patient demographics, ROM and function levels, outcome measures, and preoperative indications, as well as the inclusion of clinical data that assesses complete exchange, single exchange, and tibial insert exchange.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Polietileno , Rango del Movimiento Articular , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Femenino , Reoperación/estadística & datos numéricos , Masculino , Anciano , Persona de Mediana Edad , Prótesis de la Rodilla/efectos adversos , Articulación de la Rodilla/cirugía , Fibrosis , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Falla de Prótesis/etiología
4.
J Arthroplasty ; 39(9): 2295-2302, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38649065

RESUMEN

BACKGROUND: Total hip arthroplasty (THA) adverse events among patients who have dental diagnoses remain unclear. We sought to determine if dental caries or dental implant placements increased (1) 90-day medical complications, (2) 90-day readmissions, and (3) 2-year implant-related complications, including periprosthetic joint infections (PJIs) after THA. METHODS: A nationwide database for primary THAs from 2010 to 2021 was queried to compare 3 patient cohorts. Patients who had a history of dental implants or caries within 12 months prior to THA (n = 1,179) or 12 months after THA (n = 1,218) were case-matched to patients who did not have dental history (n = 6,090) by age and comorbidities. Outcomes included 90-day complications, 90-day readmissions, and 2-year implant-related complications. Logistic regression models computed the odds ratios (ORs) of complications and readmissions. P values less than .006 were significant. RESULTS: Patients who had dental caries or implant placement 12 months before or after THA experienced 1.6-fold greater odds of 90-day medical complications compared to case-matched patients. Readmissions within 90 days increased for patients who had a dental history before (11.7% versus 8.3%; OR: 1.49, P < .0001) and after (14.2% versus 8.3%; OR: 1.84, P < .0001) THA compared to case-matched patients. A dental caries diagnosis or dental implant placement within 12 months following THA increased 2-year implant complications compared to case-matched patients (15.2% versus 9.3%; OR: 1.69, P < .0001), including PJIs (5.3% versus 2.8%; OR: 1.98, P < .0001), dislocations (4.4% versus 2.7%; OR: 1.63, P = .002), and THA revisions (3.9% versus 2.5%; OR: 1.61, P = .005). CONCLUSIONS: Dental diagnoses within 12 months of THA are associated with increased medical complications. Dental diagnoses occurring 12 months after THA are associated with greater implant-related complications, including PJIs. Delaying invasive dental procedures for 12 months after THA may be advisable.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Caries Dental , Implantes Dentales , Complicaciones Posoperatorias , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Caries Dental/etiología , Caries Dental/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Implantes Dentales/efectos adversos , Readmisión del Paciente/estadística & datos numéricos , Prótesis de Cadera/efectos adversos , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/epidemiología , Adulto
5.
Eur J Orthop Surg Traumatol ; 34(4): 1825-1830, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38429555

RESUMEN

INTRODUCTION: There is continued debate regarding the survivorship and revision rate of cementless versus cemented total knee arthroplasty (TKA) prostheses. This includes the assessment of early revision surgery due to aseptic loosenings and periprosthetic joint infections (PJIs). Studies have not always taken into account the impact of comorbidities, such as diabetes, obesity, and tobacco. Therefore, we compared revisions in a large population of patients undergoing cemented or cementless TKAs at 90 days, 1 year, and 2 years. METHODS: A review of an administrative claims database was used to identify patients undergoing primary TKA, either cementless (n = 8,890) or cemented (n = 215,460), from October 1, 2015 to October 31, 2020. Revision surgery for PJI and aseptic loosening were identified with diagnosis and associated procedural codes at 90 days, 1 year, and 2 years and then compared between groups. A propensity matched-analysis was performed for age, sex, Charles Comorbidity Index (CCI) > 3, alcohol abuse, tobacco use, obesity, and diabetes. Chi square tests assessed statistical significance of differences in the matched cohorts using odds ratios (ORs) with 95% confidence intervals (CIs). A P < 0.05 was defined as statistically significant. RESULTS: Cementless TKA was associated with similar revisions rates due to PJIs at 90 days (OR, 1.04, 95% CI 0.79-1.38, p = 0.83), 1 year (OR, 0.93, 95% CI 0.75-1.14, p = 0.53, and 2 years (OR, 0.87, 95% CI 0.73-1.05, p = 0.17) in comparison to the cemented TKA cohort. The odds ratio of revision due to aseptic loosening was similar as well at 90 days (OR, 0.67, 95% CI 0.34-1.31, 0.31), 1 year (OR, 1.09, 95% CI 0.73-1.61, p = 0.76), and 2 years (OR, 1.00, 95% CI 0.73-1.61, p = 0.99). CONCLUSIONS: This study found a comparable risk of PJI and aseptic loosening in cementless and cemented TKA when controlling for several comorbidities, such as tobacco, diabetes, and alcohol. Therefore, with proper patient selection, cementless TKAs can be performed with expectation of low risks of infections and aseptic loosenings.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cementos para Huesos , Puntaje de Propensión , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/métodos , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Masculino , Reoperación/estadística & datos numéricos , Anciano , Falla de Prótesis/etiología , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/etiología , Prótesis de la Rodilla/efectos adversos , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/epidemiología , Comorbilidad , Cementación
6.
J Arthroplasty ; 38(3): 476-483, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36252742

RESUMEN

BACKGROUND: Consensus regarding prior dental problems on the outcomes of total knee arthroplasty (TKA) patients is lacking. Therefore, our objectives were to determine the association of dental caries or dental implant placement in TKA patients on the following: (1) medical complications; (2) health care utilization (lengths of stay and readmissions); (3) implant-related complications; and (4) expenditures. METHODS: A retrospective query was performed using an administrative claims database for 3 patient cohorts undergoing primary TKA from 2010 to 2020. Patients who had a history of dental caries or implant placement 1 year prior to TKA (n = 1,466) and 1 year after TKA (n = 1,127) were case-matched to patients who did not have a dental history by age and comorbidities. Outcomes included 90-day complications, health care utilization parameters, 2-year implant complications, and expenditures. Logistic regression models computed odds ratios (OR) of complications and readmissions. P values less than 0.005 were significant. RESULTS: Patients who had a dental implant placement prior to TKA had higher frequency of complications (20.05 versus 14.01%; OR: 1.53, P < .0001), including myocardial infarctions (2.52 versus 1.23%; OR: 2.08, P = .0002) and pneumonia (2.52 versus 1.24%; OR: 2.06, P = .0002). Lengths of stay (3.28 versus 2.98 days; P = .255), readmission rates (4.71 versus 4.28%; P = .470), and implant-related complications including periprosthetic joint infections (3.14 versus 2.63%; OR: 1.20, P = .279) were similar between patients lacking dental history. Expenditures were higher in patients who had a postoperative and preoperative dental history ($19,252 versus $19,363 versus 17,980; P < .001). CONCLUSION: Dental caries or implant placement may reflect overall worse medical condition resulting in more complications and higher costs after TKA. Dental history screening preoperatively may assist arthroplasty surgeons in minimizing complications.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Caries Dental , Implantes Dentales , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Estudios Retrospectivos , Caries Dental/complicaciones , Caries Dental/epidemiología , Caries Dental/cirugía , Susceptibilidad a Caries Dentarias , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Tiempo de Internación , Readmisión del Paciente , Factores de Riesgo
7.
J Arthroplasty ; 38(5): 939-944.e1, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36574538

RESUMEN

BACKGROUND: Previous retrieval studies of patellar components for total knee arthroplasty focused on historical designs and polyethylene materials that are no longer clinically relevant. Therefore, this study aimed to compare revision reasons and surface damage mechanisms of conventional, gamma inert sterilized polyethylene and highly cross-linked polyethylene (HXLPE) patellar components in contemporary designs from a single manufacturer. METHODS: A total of 114 gamma inert and 76 HXLPE patellar components were gathered in a multicenter orthopaedic implant retrieval program. Patient age and body mass index were similar between cohorts (P = .27 and P = .42, respectively); however, the gamma inert cohort was implanted longer (µdifference = 3.1 years; P = .005). A matched subset was created based on the total knee arthroplasty design, patellar shape, and implantation time. Revision reasons were gathered from revision operating notes, and surface damage was examined via the Hood scoring method. Differences between HXLPE and gamma inert cohorts were evaluated using Mann-Whitney U-tests. RESULTS: The most common revision reasons were infection, loosening, and instability, with the most common patellar complication resulting in revision being patellar loosening for both cohorts with similar incidences for both (chi-square; P = .60, P = .59). The most common surface damage modes were burnishing, scratching, and pitting in both cohorts. Total surface damage was significantly higher in the gamma inert components (P = .02), but not in the matched subset (P = .46). CONCLUSION: Overall, the clinical performance of HXLPE was similar to that of conventional polyethylene for patellar components with short implantation times. While this study provides much needed information on the performance of HXLPE patellae in short-term retrievals, long-term studies are still needed.


Asunto(s)
Prótesis de la Rodilla , Polietileno , Humanos , Falla de Prótesis , Reoperación , Diseño de Prótesis
8.
J Arthroplasty ; 37(7S): S592-S597, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35210151

RESUMEN

BACKGROUND: Characterizations and factors influencing longer term performance of second-generation sequentially irradiated and annealed highly cross-linked polyethylene (HXLPE) are lacking. We evaluated patients who underwent total hip arthroplasty with HXLPE at mean 10-year follow-up for (1) linear and volumetric wear rates, (2) patient and implant characteristics, (3) implant survivorships, and (4) functional scores. METHODS: We evaluated 130 hips (110 patients) that received HXLPE acetabular liners at a single center. The mean age was 56 years (range, 20-79 years), with a mean follow-up of 10 years (range, 8-15). Radiographic linear (millimeters/year) and volumetric (cubic millimeters/year) wear rates were quantified using radiographic analysis. Survivorship was assessed by all-cause and wear-related revision rates. Functional outcomes were assessed by Short Form 12 and modified Harris Hip Scores. RESULTS: The mean linear wear rate was 0.02 ± 0.03 mm/y, and the mean volumetric wear rate was 12.6 ± 5.3 mm3/y. Younger age had higher volumetric wear (total and yearly, P = .01). Increasing body mass index trended toward higher total and yearly linear (both, P ≤ .09) and volumetric wear (both, P ≤ .07). Ten patients required revisions, with an all-cause survivorship of 92% and a wear survivorship of 100%. The mean modified Harris Hip Scores was 84, and the mean Short Form 12 scores were 46 (physical) and 55 (mental). CONCLUSION: We observed low linear and volumetric wear rates for HXLPE at 10-year mean follow-up. Younger age and higher body mass index at the time of surgery may be important patient characteristics influencing long-term wear. These results illustrate the potential for this second-generation HXLPE to be an appropriate long-term total hip arthroplasty interface.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/métodos , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Polietileno , Diseño de Prótesis , Falla de Prótesis
9.
J Arthroplasty ; 36(7S): S80-S87, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33610405

RESUMEN

BACKGROUND: Dual mobility (DM) articulations were introduced for total hip arthroplasty to reduce the risk of instability for patients who have a high risk of dislocation. The use of DM constructs in both primary and revision total hip arthroplasty has been steadily increasing, leading to concerns regarding potential risks of fretting corrosion, polyethylene wear, metal release, and failure due to component positioning. METHODS: A total of 56 retrieved DM constructs were collected. The inner and outer polyethylene liner surfaces were assessed for 7 damage mechanisms, and fretting corrosion was evaluated for the femoral stem, head, and modular liner. Three polyethylene liners with the greatest amounts of embedded debris were examined using scanning electron microscopy. Energy-dispersive X-ray spectroscopy was used to determine the elemental content of the debris. Acetabular cup orientation was analyzed radiographically using the EBRA (Einzel-Bild-Roentgen-Analyse) method. RESULTS: The devices were revised most frequently for infection (36%), loosening (21%), and instability/dislocation (18%). The most common polyethylene damage mechanisms were scratching, pitting, burnishing, and embedded debris, and no difference in total damage was found between primary and revision cases. Scanning electron microscopy/energy-dispersive X-ray spectroscopy revealed that debris morphology and composition were consistent with porous titanium coating, resulting from cup loosening or broken screws and augments. A total of 71% and 50% of the constructs were determined to be within the Lewinnek safe zone for inclination and anteversion, respectively. CONCLUSION: The most notable mechanisms of surface damage were due to third-body debris, especially for the polyethylene surfaces which articulate against cobalt-chromium femoral heads and acetabular liners. Scratching of the femoral head and the metal liner from this debris may support the clinical use of ceramic for DM bearing surfaces in the future.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Artroplastia de Reemplazo de Cadera/efectos adversos , Corrosión , Prótesis de Cadera/efectos adversos , Humanos , Polietileno , Diseño de Prótesis , Falla de Prótesis
10.
Surg Technol Int ; 36: 388-396, 2020 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-32215904

RESUMEN

The demographics of total knee arthroplasty (TKA) patients are changing. Individuals are more active, younger, and more obese. These changing demographics and a higher demand for longevity creates a new challenge for reliable and long-term implant fixation. Historically, cemented fixation has remained the gold standard, as cementless design and techniques from the 1980s and 1990s did not obtain long-term positive outcomes due to a failure of ingrowth onto the implants. Advances in the modern-day cementless TKA designs appear to have overcome their initial challenges, indicating the dependence of cementless TKA on implant design. However, there remains the perception that cementless total knee arthroplasty are inferior to cemented TKA. This review discusses the longer-term survivorship data for recent systems, which has shown the potential advantages of cementless fixation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Cementos para Huesos , Humanos , Obesidad , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
11.
Surg Technol Int ; 36: 351-359, 2020 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-32196565

RESUMEN

INTRODUCTION: Although the use of cementless implants in total knee arthroplasty (TKA) has increased in recent years, there is still ongoing debate regarding the optimal method of fixation. The purpose of this review was to evaluate the evidence regarding cementless versus cemented total knee arthroplasty (TKA) with regard to: (1) all-cause survivorship and aseptic survivorship; and (2) patient-reported outcome measures (PROMs) of newer generation TKAs. MATERIALS AND METHODS: A systematic review of all reports on cementless TKA published from January 2010 to February 2019 was performed. A total of 221 articles were evaluated and 39 studies met inclusion criteria for final analysis. Metrics evaluated included all-cause survivorship, aseptic survivorship, and Knee Society Scores (KSS). RESULTS: Modern cementless TKA provides excellent survivorship and patient-reported outcomes as compared to cemented designs. CONCLUSIONS: Recent studies have demonstrated that newer generation cementless TKAs provide similar functional outcomes and survivorship as compared to cemented TKA. However, additional prospective, randomized trials with long-term follow up are necessary to further compare the outcomes of cementless versus cemented TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Cementos para Huesos , Humanos , Articulación de la Rodilla , Estudios Prospectivos , Falla de Prótesis , Resultado del Tratamiento
12.
Eur J Orthop Surg Traumatol ; 30(3): 447-453, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31691153

RESUMEN

INTRODUCTION: The goals of this study were to compare patient satisfaction and wound-related complications in patients receiving 2-octyl cyanoacrylate (glue) and polyester mesh for skin closure after primary total knee arthroplasty (TKA) versus staples. METHODS: A total of 60 knees in 54 patients undergoing TKA were enrolled in a prospective trial and randomized to receive either skin closure with glue and polyester mesh (n = 30) or a control group closed with staples (n = 30). Hollander wound cosmesis score (measured on a scale of 0-5, with 0 being the best) and visual analog scale (VAS) scores (range 0-100 mm) for patient satisfaction with wound cosmesis, as well as wound-related readmission, reoperation, and complications, including superficial surgical site infection, wound dehiscence, wound hematoma, stitch abscess, and wound discharge, were assessed at 6 weeks and 90 days after TKA. Baseline characteristics were not statistically significantly different between the groups (p > 0.05). RESULTS: At 6 weeks and 90 days, the Hollander wound cosmesis score was significantly lower (p < 0.01) in the glue and polyester mesh groups. Similarly, at 6 weeks and 90 days, the VAS for patient satisfaction with wound cosmesis was significantly higher (p < 0.01) in the glue and polyester mesh groups. The rate of superficial surgical site infection was 1/30 (3%) in glue and polyester mesh groups versus zero in the control group (p = 1.00). The rate of wound dehiscence was 1/30 (3%) in glue and polyester mesh groups versus zero in the control group (p = 1.00). CONCLUSION: These results suggest that glue and polyester mesh closure may offer superior cosmetic outcomes to staples for skin closure in TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Satisfacción del Paciente , Mallas Quirúrgicas , Técnicas de Cierre de Heridas , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/instrumentación , Técnicas Cosméticas , Cianoacrilatos , Estética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Poliésteres , Estudios Prospectivos , Herida Quirúrgica/cirugía , Suturas/efectos adversos , Técnicas de Cierre de Heridas/efectos adversos
13.
J Arthroplasty ; 34(12): 3088-3093, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31416742

RESUMEN

BACKGROUND: In order to improve oxidation resistance, antioxidants such as vitamin-E are added to polyethylene used in the bearing surfaces of orthopedic components. Currently, little is known about the efficacy of this treatment in vivo. This study therefore reports on the reasons for revision, surface damage mechanisms, and oxidation of retrieved vitamin E-stabilized highly crosslinked polyethylene (HXLPE) for total knee arthroplasty. METHODS: We examined 103 retrieved knee inserts fabricated from vitamin E (VE)-stabilized HXLPE and 67 fabricated from remelted HXLPE as a control. The implantation times were 1.2 ± 1.3 and 1.5 ± 1.3 years for the VE and control cohorts, respectively. The inserts were evaluated for 7 surface damage mechanisms using a semiquantitative scoring method and analyzed for oxidation using Fourier-transform infrared spectroscopy. Reasons for revision were also assessed using operative notes created at time of retrieval. RESULTS: Both groups were revised primarily for instability, infection, and loosening. Burnishing, pitting, and scratching were the most common damage mechanisms observed, with the VE cohort demonstrating less surface damage than the control. Measured oxidation for the cohort was low, with a median oxidation index of 0.09 ± .05 for the articulating surface, 0.05 ± 0.06 for the backside, 0.08 ± 0.06 for the anterior/posterior surfaces, and 0.08 ± 0.05 for the stabilizing post. As compared to the control cohort, oxidation tended to be less for the VE group at the articulating (P < .001) and backside (P = .003) surfaces, although the median differences were minimal and may not be clinically significant. CONCLUSION: The results indicate positive fatigue damage resistance and oxidation resistance for the retrieved VE-stabilized total knee arthroplasty inserts.


Asunto(s)
Antioxidantes/farmacología , Prótesis de la Rodilla , Polietileno/química , Falla de Prótesis/etiología , Vitamina E/farmacología , Anciano , Artroplastia de Reemplazo de Rodilla/instrumentación , Femenino , Humanos , Articulación de la Rodilla/cirugía , Masculino , Persona de Mediana Edad , Oxidación-Reducción , Diseño de Prótesis , Espectroscopía Infrarroja por Transformada de Fourier
14.
J Arthroplasty ; 34(7S): S331-S336, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30545655

RESUMEN

BACKGROUND: The purpose of this study is to identify factors affecting operative times and to evaluate the associations of operative times with prosthetic joint infections (PJIs) and surgical site infections (SSIs) in primary total knee arthroplasty. METHODS: A total of 11,840 primary total knee arthroplasties with a mean 2-year post-operative follow-up were studied. Operative times were analyzed both as categorical and continuous variables. Associations with PJIs and SSIs were evaluated with univariate and multivariate analyses to adjust for gender, age, body mass index, Charlson Comorbidity Index, year of surgery, antibiotic cement use, and hospital/surgeon volume. RESULTS: The longest cases (>121 minutes) were associated with patients who were younger (P < .001) and had a higher body mass index (P < .001). PJI rates were higher in cases >121 minutes (1.4%) compared to those <85 minutes (0.3%, P < .001). SSI rates were also highest (3.8%) in cases >121 minutes (P < .001). Cases complicated by PJIs (135 ± 47 minutes) had longer mean operative times compared to non-infected cases (105 ± 32 minutes, P < .001). Patients with subsequent SSIs also had longer mean operative times (P < .001). Multivariate analyses revealed an 18% increased risk for PJIs and an 11% increased risk for SSIs for every 15-minute increase in operative time. CONCLUSION: Identifying risk factors for infection that are as easily measurable and modifiable as procedure duration can aid in risk-stratifying post-operative surveillance. This study demonstrated that longer operative times were an independent predisposing factor for both PJIs and SSIs even after accounting for patient and procedure-related factors.


Asunto(s)
Artritis Infecciosa/etiología , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Tempo Operativo , Infección de la Herida Quirúrgica/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Antibacterianos , Índice de Masa Corporal , Cementos para Huesos , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos , Factores de Riesgo , Adulto Joven
15.
J Arthroplasty ; 34(9): 2091-2095.e1, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31109755

RESUMEN

BACKGROUND: The purpose of this study is to evaluate the effect of commercially available antibiotic-impregnated bone cement (AIBC) on (1) prosthetic joint infections (PJIs) and (2) surgical site infections (SSIs) after primary total knee arthroplasty (TKA). METHODS: A review of primary TKAs between 2014 and 2017 from an institutional database was conducted. This identified 12,541 cases which were separated into AIBC (n = 4337) and non-AIBC (8,164) cohorts. Medical records were reviewed for PJIs and SSIs (mean 2-year postoperative period). Infection rates between the cohorts were compared with univariate analyses followed by subanalysis of high risk patients (defined as having 2 or more of the following characteristics: >65 years, body mass index >40, or Charlson Comorbidity Index score >3). To control for confounders, multivariate analyses were performed with regression models adjusted for age, gender, body mass index, comorbidities, year, operative times, and lengths of stay. RESULTS: On univariate analysis, PJI rates were higher in the AIBC cohort (1.0%) compared to the non-AIBC cohort (0.5%, P < .001). Subanalysis of the high risk patients also showed that PJI rates were higher in the AIBC cohort (1.9% vs 0.6%, P < .01). After adjusting for potential confounders, no significant associations between PJIs and AIBC use were found (odds ratio 1.4, 95% confidence interval 0.9-2.3, P = .133). Similarly, no significant differences in SSI rates were observed between the AIBC (2.9%) and non-AIBC cohorts (2.4%, P = .060) and no significant associations between SSIs and AIBC were found with multivariate analysis (odds ratio 1.0, 95% confidence interval CI 0.8-1.3, P = .948). CONCLUSION: This study found that there was no clinically or statistically significant decrease in infection rates with AIBC in primary TKAs.


Asunto(s)
Antibacterianos/administración & dosificación , Artritis Infecciosa/prevención & control , Artroplastia de Reemplazo de Rodilla/efectos adversos , Cementos para Huesos , Infecciones Relacionadas con Prótesis/prevención & control , Infección de la Herida Quirúrgica/prevención & control , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Artritis Infecciosa/etiología , Registros Electrónicos de Salud , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Periodo Posoperatorio , Infecciones Relacionadas con Prótesis/etiología , Análisis de Regresión , Estudios Retrospectivos , Infección de la Herida Quirúrgica/etiología , Resultado del Tratamiento , Adulto Joven
16.
J Arthroplasty ; 33(5): 1399-1403, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29195849

RESUMEN

BACKGROUND: The purpose of this study is to evaluate (1) implant survivorship; (2) patient outcomes; (3) complications; and to (4) perform a radiographic analysis of cementless posteriorly stabilized total knee arthroplasty (TKA) patients at a minimum of 7-year follow-up. METHODS: Our original cohort was composed of 114 consecutive cementless posteriorly stabilized total knee arthroplasties (110 patients) performed by a single surgeon between 2008 and 2010. Since our original report, 4 (1 bilateral) patients died and 2 were lost to follow-up. Therefore, there were 104 patients who had 107 knees available for final follow-up. The final cohort included 43 men and 61 women, who had a mean age of 69 years (range 47-87) and were followed from 7 to 9 years (mean 8 years). Patient outcomes and complications were obtained from electronic medical records. Radiographic assessment was done using the Knee Society Radiographic Evaluation System. RESULTS: The all-cause survivorship was 98% (95% confidence interval 1.01-0.96). Since the original report, there has been 1 post-traumatic loosening of the tibial baseplate, and 1 revision for instability. There were no femoral revisions or patella revisions. The mean Knee Society pain score was 93 points (range 80-100) and the function score was 78 points (range 68-95). Excluding revisions, there was no evidence of progressive loosening of any implant components. CONCLUSION: Based on these 7-year minimum follow-ups, femoral, tibial, and patellar cementless hydroxylapatite-coated beaded implants perform well at up to 9 years postoperatively and offer surgeons and patients a cementless option that may provide long-lasting biological fixation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Diseño de Prótesis , Anciano , Anciano de 80 o más Años , Cementos para Huesos , Progresión de la Enfermedad , Durapatita , Registros Electrónicos de Salud , Femenino , Fémur/cirugía , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Rótula/cirugía , Radiografía , Tibia/cirugía
17.
J Arthroplasty ; 33(4): 1235-1241, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29329883

RESUMEN

BACKGROUND: Sequentially annealed, highly crosslinked polyethylene (HXLPE) has been used clinically in total knee arthroplasty (TKA) for over a decade. However, little is known about the revision reasons; its surface damage mechanisms; or its in vivo oxidative stability relative to conventional polyethylene. We asked whether retrieved HLXPE tibial inserts exhibited: (1) similar revision reasons; (2) improved resistance to surface damage; and (3) improved oxidative stability, when compared with conventional gamma inert sterilized polyethylene inserts. METHODS: A total of 456 revised tibial inserts were collected in a multicenter retrieval program between 2000 and 2016. The implantation time for the HXLPE components was 1.8 ± 1.8 years, and for the control inserts it was 3.4 ± 2.7 years. Revision reasons were assessed based on medical records, radiographs, and examinations of the retrieved components. Surface damage was assessed using a semi-quantitative scoring method. Oxidation was measured using Fourier transform infrared spectroscopy. RESULTS: The tibial inserts in both cohorts were revised most frequently for loosening, infection, and instability. The most commonly observed surface damage modes were burnishing, pitting, and scratching. Oxidation of the HXLPE inserts was, on average, low and similar to the control inserts at the bearing surface and the stabilizing post. CONCLUSIONS: We observed evidence of in vivo oxidation in both HXLPE and control tibial inserts. We found no association between the levels of oxidation and the clinical performance of the HXLPE tibial components. The findings of this study document the revision reasons, surface damage modes, and oxidative behavior of sequentially annealed HXLPE for TKA.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla , Polietileno/química , Falla de Prótesis , Reoperación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Oxidación-Reducción , Oxígeno , Diseño de Prótesis , Radiografía , Espectroscopía Infrarroja por Transformada de Fourier , Esterilización , Propiedades de Superficie , Tibia/cirugía
18.
J Arthroplasty ; 33(1): 90-96, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28802777

RESUMEN

BACKGROUND: Local infiltration analgesia (LIA) with liposomal bupivacaine (LB) in patients undergoing total knee arthroplasty (TKA) has yielded mixed results. The PILLAR study, which was designed to minimize limitations associated with previous studies, compared the effects of LIA with or without LB on pain scores, opioid consumption, including proportion of opioid-free patients, time to first opioid rescue, and safety after primary unilateral TKA. METHODS: Patients (N = 140) were randomized to LIA with LB 266 mg/20 mL (admixed with bupivacaine HCl 0.5%, 20 mL) or LIA with bupivacaine HCl 0.5%, 20 mL. Standardized infiltration techniques and a standardized multimodal pain management protocol were used. The coprimary efficacy endpoints were area under the curve (AUC) of visual analog scale pain intensity scores 12-48 hours (AUC12-48) postsurgery and total opioid consumption 0-48 hours postsurgery. RESULTS: Mean AUC12-48 of visual analog scale pain intensity score was 180.8 with LB and 209.3 without LB (least squares [LS] mean treatment difference -26.88, P = .0381). LS mean total opioid consumption 0-48 hours postsurgery was 18.7 mg with and 84.9 mg without LB (LS ratio 0.220, P = .0048). Significant differences in favor of LB were observed for the percentage of opioid-free patients (P < .01) and time to first opioid rescue (P = .0230). Treatments were similarly well tolerated. CONCLUSION: This study provides data on LIA with LB administered using optimal techniques specific to TKA. In this setting, LIA with LB significantly improved postsurgical pain, opioid consumption, and time to first opioid rescue, with more opioid-free patients and no unexpected safety concerns.


Asunto(s)
Analgesia/métodos , Anestésicos Locales/administración & dosificación , Artroplastia de Reemplazo de Rodilla , Bupivacaína/administración & dosificación , Manejo del Dolor/métodos , Dolor Postoperatorio/tratamiento farmacológico , Anciano , Analgésicos Opioides/administración & dosificación , Área Bajo la Curva , Método Doble Ciego , Femenino , Humanos , Hipoestesia/etiología , Estimación de Kaplan-Meier , Liposomas/química , Masculino , Persona de Mediana Edad , Trastornos Relacionados con Opioides , Dimensión del Dolor
19.
J Arthroplasty ; 33(10): 3343-3353, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29929829

RESUMEN

Multiple recent reports have indicated a rising awareness of trunnionosis-related implant failures, accounting for up to 3% of all total hip arthroplasty revisions. Moreover, aseptic loosening and osteolysis from local release of metal debris can be the presenting manifestations, and thus the true incidence of trunnionosis is thought to be underreported. Furthermore, the relatively unclear and multifactorial pathogenesis and the widely variable clinical presentations pose a diagnostic challenge. A consensus regarding the ideal intervention and its timing is also lacking. Because of the relative paucity of reports regarding the diagnosis and management of trunnionosis, we conducted this evidence-based review to evaluate the (1) incidence, (2) pathogenesis, (3) diagnosis, and (4) treatment of trunnionosis in metal-on-polyethylene total hip arthroplasty. We then propose an algorithm for the diagnostic work-up and management of this condition.


Asunto(s)
Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Osteólisis/etiología , Falla de Prótesis/etiología , Algoritmos , Artroplastia de Reemplazo de Cadera/instrumentación , Corrosión , Humanos , Incidencia , Metales/sangre , Polietileno , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Diseño de Prótesis
20.
Surg Technol Int ; 33: 265-270, 2018 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-30276781

RESUMEN

INTRODUCTION: To help limit wear, newer polyethylene liners, such as the highly cross-linked polyethylene (HXLPE) liners, have been developed. These newer liners undergo an alternating irradiation process, resulting in a stronger, longer-lasting liner. The purpose of this study was to analyze the wear rates of patients who underwent THA and received a newer generation HXLPE acetabular insert. Specifically, we compared: 1) linear vector wear amount and 2) linear vector wear rates in patients as an overall cohort and by gender. We also assessed patient satisfaction outcomes comparing preoperative Harris Hip Scores (HHS) to seven-week, one-year, and three-year HHS scores. MATERIALS AND METHODS: A total of 23 patients who underwent total hip arthroplasty (THA) with direct superior approach by a fellowship-trained orthopaedic surgeon at a private practice institution were analyzed after receiving institutional review board approval. Patients had a minimum two-year follow up, with the mean follow up being four years (range, three to five years). All patients received a 36-mm ceramic femoral head with an HXLPE liner. 2D radiographic polyethylene wear analysis was performed using the Martell Hip Analysis Suite (HAS; University of Chicago, Illinois), which has been previously validated in the literature. Outcomes were assessed using Harris Hip Scores. RESULTS: A five-year linear wear rate of 0.073 mm/year (range, 0 to 0.160 mm/year) and an overall mean linear wear rate of 0.096 mm/year (range, 0 to 0.277 mm/year) were found. No significant differences in wear were seen between genders. Additionally, patients reported significantly better results at seven-weeks (83 points [range, 59 to 100 points]) and one-year (94 points [range, 85 to 100 points]) than preoperative (52 points [range, 34 to 73 points]) HSS scores (p<0.05). No patients underwent revision THA. CONCLUSION: The results from this study highlight the benefits of using an HXLPE polyethylene liner in THA patients and further validates previously reported wear rates of HXLPE liners. After an early "wear in" period during the first year, the wear rates steadily decreased over time. This liner showed excellent early outcomes as no patients underwent revision THA. Furthermore, even as early as seven postoperative weeks, patients reported significantly better HHS scores. Future studies should track the same patient cohort over time to help develop a wear-rate prediction model.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera/estadística & datos numéricos , Polietileno/uso terapéutico , Artroplastia de Reemplazo de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/instrumentación , Artroplastia de Reemplazo de Cadera/estadística & datos numéricos , Estudios de Cohortes , Humanos , Satisfacción del Paciente/estadística & datos numéricos , Diseño de Prótesis , Falla de Prótesis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA