1.
Clin Oral Investig ; 25(4): 1869-1877, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32951123

RESUMEN

OBJECTIVES: LAY-FOMM is a promising material for FDA-approved Fused Deposition Modeling (FDM) applications in drug delivery. Here we investigated the impact on oral cells. MATERIALS AND METHODS: We evaluated the impact of 3D-printed LAY-FOMM 40, LAY-FOMM 60, and biocompatible polylactic acid (PLA) on the activity of murine L929 cells, gingival fibroblasts (GF), and periodontal ligament fibroblasts (PDLF) using indirect (samples on cells), direct monolayer culture models (cells on samples), and direct spheroid cultures with resazurin-based toxicity assay, confirmed by MTT and Live-dead staining. The surface topography was evaluated with scanning electron microscopy. RESULTS: The materials LAY-FOMM 40 and LAY-FOMM 60 led to a reduction in resazurin conversion in L929 cells, GF, and PDLF, higher than the impact of PLA in indirect and direct culture models. Fewer vital cells were found in the presence of LAY-FOMM 40 and 60 than PLA, in the staining in both models. In the direct model, LAY-FOMM 40 and PLA showed less impact on viability in the resazurin-based toxicity assay than in the indirect model. Spheroid microtissues showed a reduction of cell activity of GF and PDLF with LAY-FOMM 40 and 60. CONCLUSION: Overall, we found that LAY-FOMM 40 and LAY-FOMM 60 can reduce the activity of L292 and oral cells. Based on the results from the PLA samples, the direct model seems more reliable than the indirect model. CLINICAL RELEVANCE: A material modification is desired in terms of biocompatibility as it can mask the effect of drugs and interfere with the function of the 3D-printed device.


Asunto(s)
Fibroblastos , Encía , Animales , Células Cultivadas , Humanos , Ratones , Ligamento Periodontal , Impresión Tridimensional
2.
Sci Rep ; 13(1): 12082, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-37495645

RESUMEN

Field driven design is a novel approach that allows to define through equations geometrical entities known as implicit bodies. This technology does not rely upon conventional geometry subunits, such as polygons or edges, rather it represents spatial shapes through mathematical functions within a geometrical field. The advantages in terms of computational speed and automation are conspicuous, and well acknowledged in engineering, especially for lattice structures. Moreover, field-driven design amplifies the possibilities for generative design, facilitating the creation of shapes generated by the software on the basis of user-defined constraints. Given such potential, this paper suggests the possibility to use the software nTopology, which is currently the only software for field-driven generative design, in the context of patient-specific implant creation for maxillofacial surgery. Clinical scenarios of applicability, including trauma and orthognathic surgery, are discussed, as well as the integration of this new technology with current workflows of virtual surgical planning. This paper represents the first application of field-driven design in maxillofacial surgery and, although its results are very preliminary as it is limited in considering only the distance field elaborated from specific points of reconstructed anatomy, it introduces the importance of this new technology for the future of personalized implant design in surgery.


Asunto(s)
Cirugía Ortognática , Procedimientos Quirúrgicos Ortognáticos , Cirugía Asistida por Computador , Cirugía Bucal , Humanos , Cirugía Asistida por Computador/métodos , Programas Informáticos , Procedimientos Quirúrgicos Ortognáticos/métodos , Imagenología Tridimensional/métodos
3.
Mater Sci Eng C Mater Biol Appl ; 124: 112085, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33947575

RESUMEN

Conventional electrospun small diameter vascular grafts have a random fiber orientation. In order to achieve mechanical characteristics similar to a native blood vessel, a controllable fiber orientation is of interest. In this study the electrospinning jet was directly controlled by means of an auxiliary, changeable electrostatic field, so that the fibers could be deposited in adjustable orientations. Prostheses with circumferentially, axially, fenestrated and randomly aligned fibers were electrospun on Ø2mm mandrels out of a thermoplastic polyurethane (PUR) and a polylactid acid (PLLA). The impact of the materials and the various preferential fiber orientations on the resulting biomechanics was investigated and compared with that of the native rat aorta in quasistatic and dynamic hoop tensile tests. The test protocol included 3000 dynamic loading cycles in the physiological blood pressure range and ended with a quasistatic tensile test. Any orientation of the fibers in a particular direction resulted in a significant reduction in scaffold porosity for both materials. The standard randomly oriented PUR grafts showed the highest compliance of 29.7 ± 5.5 [%/100 mmHg] and were thus closest to the compliance of the rat aortas, which was 37.2 ± 6.5 [%/100 mmHg]. The maximum tensile force was increased at least 6 times compared to randomly spun grafts by orienting the fibers in the circumferential direction. During the 3000 loading cycles, creeping of the native rat aorta was below 1% whereas the electrospun grafts showed creeping up to 2.4 ± 1.2%. Although the preferred fiber orientations were only partially visible in the scanning electron micrographs, the mechanical effects were evident. The investigations suggest a multi-layer wall structure of the vascular prosthesis, since none of the preferred fiber directions and the materials used could imitate the typical j-shaped mechanical characteristics of the rat aorta.


Asunto(s)
Prótesis Vascular , Injerto Vascular , Animales , Aorta , Fenómenos Mecánicos , Poliuretanos , Ratas
4.
J Mech Behav Biomed Mater ; 104: 103652, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32174410

RESUMEN

AIM: For the proper function of small diameter vascular grafts their mechanical properties are essential. A variety of testing methods and protocols exists to measure tensile strength, compliance and viscoelastic material behavior. In this study the impact of the measurement protocol in hoop tensile tests on the measured compliance and tensile strength was investigated. METHODS: Vascular grafts made out of two different materials, a thermoplastic polyurethane (PUR) and polylactid acid (PLLA), with three different wall thicknesses were produced by electrospinning. Samples were tested with a measurement protocol that allowed the comparison of dynamic sample loading to a common quasistatic tensile test. Influence of measurement temperature, preconditioning cycles and the influence of a high number of loading cycles was also investigated. Compliance and tensile strength were evaluated and compared between the different samples and the different load cases. RESULTS: In all samples a significant difference in the measured compliance was seen between an unloaded sample and a sample that was already in a preloaded state. For example in the PUR group with 100 µm wall thickness at 37 °C, the first compliance was 32.6 ± 9.6%/100 mmHg, which reduced to 15.4 ± 2.9%/100 mmHg at preloaded state. The PLLA group showed 7.5 ± 4.3%/100 mmHg vs. 0.94 ± 0.11%/100 mmHg respectively. The measurements showed the importance of dynamic testing, as the samples viscoelastic behavior had a considerable influence on the measured compliance. The quasistatic ultimate tensile test alone was not able to predict the sample's in vivo compliance. The measurement temperature had a significant influence on tensile strength and compliance. Both, the number of preconditioning cycles and the high number of loading cycles had a minor influence on the sample's compliance. CONCLUSION: With a quasistatic tensile tests alone, overestimated compliance values are measured in viscoelastic electrospun vascular samples, therefore dynamic loading cycles are required. Measurements at 37 °C are mandatory, as temperature has a significant influence on the mechanical properties.


Asunto(s)
Bioprótesis , Prótesis Vascular , Ensayo de Materiales , Poliuretanos , Temperatura , Resistencia a la Tracción