Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(33): e2203287119, 2022 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-35939711

RESUMEN

Electrical neuron stimulation holds promise for treating chronic neurological disorders, including spinal cord injury, epilepsy, and Parkinson's disease. The implementation of ultrathin, flexible electrodes that can offer noninvasive attachment to soft neural tissues is a breakthrough for timely, continuous, programable, and spatial stimulations. With strict flexibility requirements in neural implanted stimulations, the use of conventional thick and bulky packages is no longer applicable, posing major technical issues such as short device lifetime and long-term stability. We introduce herein a concept of long-lived flexible neural electrodes using silicon carbide (SiC) nanomembranes as a faradic interface and thermal oxide thin films as an electrical barrier layer. The SiC nanomembranes were developed using a chemical vapor deposition (CVD) process at the wafer level, and thermal oxide was grown using a high-quality wet oxidation technique. The proposed material developments are highly scalable and compatible with MEMS technologies, facilitating the mass production of long-lived implanted bioelectrodes. Our experimental results showed excellent stability of the SiC/silicon dioxide (SiO2) bioelectronic system that can potentially last for several decades with well-maintained electronic properties in biofluid environments. We demonstrated the capability of the proposed material system for peripheral nerve stimulation in an animal model, showing muscle contraction responses comparable to those of a standard non-implanted nerve stimulation device. The design concept, scalable fabrication approach, and multimodal functionalities of SiC/SiO2 flexible electronics offer an exciting possibility for fundamental neuroscience studies, as well as for neural stimulation-based therapies.


Asunto(s)
Terapia por Estimulación Eléctrica , Neuroestimuladores Implantables , Nanoestructuras , Semiconductores , Compuestos Inorgánicos de Carbono/química , Terapia por Estimulación Eléctrica/instrumentación , Membranas Artificiales , Compuestos de Silicona/química , Dióxido de Silicio/química
2.
Sensors (Basel) ; 16(8)2016 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-27509496

RESUMEN

This paper presents the design and development of a low cost and reliable maximal voluntary bite force sensor which can be manufactured in-house by using an acrylic laser cutting machine. The sensor has been designed for ease of fabrication, assembly, calibration, and safe use. The sensor is capable of use within an hour of commencing production, allowing for rapid prototyping/modifications and practical implementation. The measured data shows a good linear relationship between the applied force and the electrical resistance of the sensor. The output signal has low drift, excellent repeatability, and a large measurable range of 0 to 700 N. A high signal-to-noise response to human bite forces was observed, indicating the high potential of the proposed sensor for human bite force measurement.


Asunto(s)
Técnicas Biosensibles/instrumentación , Fuerza de la Mordida , Análisis del Estrés Dental/instrumentación , Diseño de Equipo , Humanos , Fenómenos Mecánicos
3.
Adv Sci (Weinh) ; 10(12): e2205656, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36808494

RESUMEN

Three-dimensional (3D) bioprinting technology offers great potential in the treatment of tissue and organ damage. Conventional approaches generally rely on a large form factor desktop bioprinter to create in vitro 3D living constructs before introducing them into the patient's body, which poses several drawbacks such as surface mismatches, structure damage, and high contamination along with tissue injury due to transport and large open-field surgery. In situ bioprinting inside a living body is a potentially transformational solution as the body serves as an excellent bioreactor. This work introduces a multifunctional and flexible in situ 3D bioprinter (F3DB), which features a high degree of freedom soft printing head integrated into a flexible robotic arm to deliver multilayered biomaterials to internal organs/tissues. The device has a master-slave architecture and is operated by a kinematic inversion model and learning-based controllers. The 3D printing capabilities with different patterns, surfaces, and on a colon phantom are also tested with different composite hydrogels and biomaterials. The F3DB capability to perform endoscopic surgery is further demonstrated with fresh porcine tissue. The new system is expected to bridge a gap in the field of in situ bioprinting and support the future development of advanced endoscopic surgical robots.


Asunto(s)
Bioimpresión , Robótica , Animales , Porcinos , Ingeniería de Tejidos/métodos , Materiales Biocompatibles , Andamios del Tejido/química
4.
ACS Appl Mater Interfaces ; 15(25): 29777-29788, 2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37318848

RESUMEN

Electrohydrodynamic atomization (EHDA) provides unparalleled control over the size and production rate of particles from solution. However, conventional methods produce highly charged particles that are not appropriate for inhalation drug delivery. We present a self-propelled EHDA system to address this challenge, a promising one-step platform for generating and delivering charge-reduced particles. Our approach uses a sharp electrode to produce ion wind, which reduces the cumulative charge in the particles and transports them to a target in front of the nozzle. We effectively controlled the morphologies of polymer products created from poly(vinylidene fluoride) (PVDF) at various concentrations. Our technique has also been proven safe for bioapplications, as evidenced by the delivery of PVDF particles onto breast cancer cells. The combination of simultaneous particle production and charge reduction, along with its direct delivery capability, makes the self-propelled EHDA a versatile technique for drug delivery applications.


Asunto(s)
Sistemas de Liberación de Medicamentos , Polivinilos , Tamaño de la Partícula
5.
J Mater Chem B ; 8(41): 9512-9523, 2020 10 28.
Artículo en Inglés | MEDLINE | ID: mdl-32996976

RESUMEN

Herein, we report the preparation of mesoporous gold (Au)-silver (Ag) alloy films through the electrochemical micelle assembly process and their applications as microRNA (miRNA) sensors. Following electrochemical deposition and subsequent removal of the templates, the polymeric micelles can create uniformly sized mesoporous architectures with high surface areas. The resulting mesoporous Au-Ag alloy films show high current densities (electrocatalytic activities) towards the redox reaction between potassium ferrocyanide and potassium ferricyanide. Following magnetic isolation and purification, the target miRNA is adsorbed directly on the mesoporous Au-Ag film. Electrochemical detection is then enabled by differential pulse voltammetry (DPV) using the [Fe(CN)6]3-/4- redox system (the faradaic current for the miRNA-adsorbed Au-Ag film decreases compared to the bare film). The films demonstrate great advantages towards miRNA sensing platforms to enhance the detection limit down to attomolar levels of miR-21 (limit of detection (LOD) = 100 aM, s/n = 3). The developed enzymatic amplification-free miniaturized analytical sensor has promising potential for RNA-based diagnosis of diseases.


Asunto(s)
Aleaciones de Oro/química , MicroARNs/análisis , Plata/química , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Diseño de Equipo , Ferrocianuros/química , Humanos , Micelas , Oxidación-Reducción , Porosidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA