Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Biomed Res Int ; 2020: 4542302, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33335923

RESUMEN

METHODS: As an acetabular bone defect model created in Bama miniswine, an augment individually fabricated by 3D print technique with Ti6Al4V powders was implanted to repair the defect. Nine swine were divided into three groups, including the immediate biomechanics group, 12-week biomechanics group, and 12-week histological group. The inner structural parameters of the 3D printed porous augment were measured by scanning electron microscopy (SEM), including porosity, pore size, and trabecular diameter. The matching degree between the postoperative augment and the designed augment was assessed by CT scanning and 3D reconstruction. In addition, biomechanical properties, such as stiffness, compressive strength, and the elastic modulus of the 3D printed porous augment, were measured by means of a mechanical testing machine. Moreover, bone ingrowth and implant osseointegration were histomorphometrically assessed. RESULTS: In terms of the inner structural parameters of the 3D printed porous augment, the porosity was 55.48 ± 0.61%, pore size 319.23 ± 25.05 µm, and trabecular diameter 240.10 ± 23.50 µm. Biomechanically, the stiffness was 21464.60 ± 1091.69 N/mm, compressive strength 231.10 ± 11.77 MPa, and elastic modulus 5.35 ± 0.23 GPa, respectively. Furthermore, the matching extent between the postoperative augment and the designed one was up to 91.40 ± 2.83%. Besides, the maximal shear strength of the 3D printed augment was 929.46 ± 295.99 N immediately after implantation, whereas the strength was 1521.93 ± 98.38 N 12 weeks after surgery (p = 0.0302). The bone mineral apposition rate (µm per day) 12 weeks post operation was 3.77 ± 0.93 µm/d. The percentage bone volume of new bone was 22.30 ± 4.51% 12 weeks after surgery. CONCLUSION: The 3D printed porous Ti6Al4V augment designed in this study was well biocompatible with bone tissue, possessed proper biomechanical features, and was anatomically well matched with the defect bone. Therefore, the 3D printed porous Ti6Al4V augment possesses great potential as an alternative for individualized treatment of severe acetabular bone defects.


Asunto(s)
Acetábulo/fisiopatología , Fuerza Compresiva , Módulo de Elasticidad , Imagenología Tridimensional/métodos , Aleaciones/química , Animales , Fenómenos Biomecánicos , Huesos , Femenino , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Oseointegración , Porosidad , Presión , Impresión Tridimensional , Prótesis e Implantes , Estrés Mecánico , Porcinos , Porcinos Enanos , Titanio/química , Microtomografía por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA