Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Arch Orthop Trauma Surg ; 143(12): 7169-7183, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37568057

RESUMEN

BACKGROUND: The component design and fixation method of joint arthroplasty may affect component migration and survival. The aim of this study was to compare fixation of cementless twin-peg (CLTP), cemented twin-peg (CTP) and cemented single-peg (CSP) femoral components of medial unicompartmental knee replacement (UKR). METHODS: Eighty patients (mean age = 63 years, 48 males) with medial knee osteoarthritis were randomized in three ways to CLTP (n = 25), CTP (n = 26) or CSP (n = 29) femoral UKR components. The patients were followed 5 years postoperatively with RSA, bone mineral density (BMD), PROMs and radiological evaluation of radiolucent lines (RLL), femoral component flexion angle and complications. RESULTS: At the 5-year follow-up, femoral component total translation was comparable between the three groups (p = 0.60). Femoral component internal rotation was 0.50° (95% CI 0.3; 0.69) for the CLTP group, 0.58° (95% CI 0.38; 0.77) for the CTP group and 0.25° (95% CI 0.07; 0.43) for the CSP group (p = 0.01). BMD decreased peri-prosthetically (range - 11.5%; - 14.0%) until 6-month follow-up and increased toward the 5-year follow-up (range - 3.6%; - 5.8%). BMD change did not correlate with component migration. Lower flexion angle was correlated with higher 5-year subsidence, total translation, varus rotation and maximum total point motion (p = 0.01). Two patients (1 CLTP, 1 CTP) had RLL in the posterior zone. There were two revisions. CONCLUSION: At 5-year follow-up, fixation of UKA femoral components with twin-peg was not superior to the single-peg design. Cementless and cemented twin-peg femoral components had similar fixation. A lower flexion angle was correlated with higher component migration.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoartritis de la Rodilla , Masculino , Humanos , Persona de Mediana Edad , Artroplastia de Reemplazo de Rodilla/métodos , Diseño de Prótesis , Osteoartritis de la Rodilla/cirugía , Radiografía , Resultado del Tratamiento , Articulación de la Rodilla/cirugía , Falla de Prótesis , Cementos para Huesos
2.
Acta Orthop ; 90(1): 67-73, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30526183

RESUMEN

Background and purpose - Hydroxyapatite (HA)-coated implants have been associated with high polyethylene wear in hip arthroplasties. HA coating as a promoter of wear in knee arthroplasties has not been investigated. We compared the wear-rate of the polyethylene bearing for cemented and cementless HA-coated Oxford medial unicondylar knee arthroplasties (UKA). Secondarily, we investigated whether wear-rates were influenced by overhang or impingement of the bearing. Patients and methods - 80 patients (mean age 64 years), treatment-blinded, were randomized to 1 of 3 Oxford medial UKA versions: cemented with double-pegged or single-pegged femoral component or cementless HA-coated with double-pegged femoral component (ratios 1:1:1). We compared wear between the cemented (n = 55) and cementless group (n = 25) (ratio 2:1). Wear, impingement, and overhang were quantified between surgery and 5-year follow-up using radiostereometry. Clinical outcome was evaluated with the Oxford Knee Score. Results - The mean wear-rate for patients without bearing overhang was 0.04 mm/year (95% CI 0.02-0.07) for the cemented group and 0.05 mm/year (CI 0.02-0.08) for the cementless group. The mean difference in wear was 0.008 mm/year (CI -0.04 to 0.03). No impingement was identified. Half of the patients had medial bearing overhang, mean 2.5 mm (1-5). Wear increased by 0.014 mm/year for each mm increment in overhang. The mean Oxford Knee Score was 39 for the cementless group and 38 for the cemented group at the 5-year follow-up. Interpretation - The wear-rates were similar for the 2 fixation methods, which supports further use of the cementless Oxford medial UKA. However, a caveat is a relatively large 95% CI of the mean difference in wear-rate. Component size and position is important as half of the patients presented with an additional increase in wear-rate due to medial bearing overhang.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Cementos para Huesos/uso terapéutico , Prótesis de la Rodilla/efectos adversos , Polietileno/uso terapéutico , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Rodilla/instrumentación , Artroplastia de Reemplazo de Rodilla/métodos , Cementación/métodos , Materiales Biocompatibles Revestidos/uso terapéutico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis de la Rodilla/cirugía , Diseño de Prótesis , Falla de Prótesis , Análisis Radioestereométrico , Resultado del Tratamiento
3.
Acta Orthop ; 88(3): 275-281, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28067099

RESUMEN

Background and purpose - Implant inducible micromotions have been suggested to reflect the quality of the fixation interface. We investigated the usability of dynamic RSA for evaluation of inducible micromotions of the Oxford Unicompartmental Knee Arthroplasty (UKA) tibial component, and evaluated factors that have been suggested to compromise the fixation, such as fixation method, component alignment, and radiolucent lines (RLLs). Patients and methods - 15 patients (12 men) with a mean age of 69 (55-86) years, with an Oxford UKA (7 cemented), were studied after a mean time in situ of 4.4 (3.6-5.1) years. 4 had tibial RLLs. Each patient was recorded with dynamic RSA (10 frames/second) during a step-up/step-down motion. Inducible micromotions were calculated for the tibial component with respect to the tibia bone. Postoperative component alignment was measured with model-based RSA and RLLs were measured on screened radiographs. Results - All tibial components showed inducible micromotions as a function of the step-cycle motion with a mean subsidence of up to -0.06 mm (95% CI: -0.10 to -0.03). Tibial component inducible micromotions were similar for cemented fixation and cementless fixation. Patients with tibial RLLs had 0.5° (95% CI: 0.18-0.81) greater inducible medio-lateral tilt of the tibial component. There was a correlation between postoperative posterior slope of the tibial plateau and inducible anterior-posterior tilt. Interpretation - All patients had inducible micromotions of the tibial component during step-cycle motion. RLLs and a high posterior slope increased the magnitude of inducible micromotions. This suggests that dynamic RSA is a valuable clinical tool for the evaluation of functional implant fixation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/diagnóstico por imagen , Prótesis de la Rodilla , Falla de Prótesis/etiología , Anciano , Artroplastia de Reemplazo de Rodilla/efectos adversos , Fenómenos Biomecánicos , Cementos para Huesos , Cementación , Prueba de Esfuerzo/métodos , Femenino , Estudios de Seguimiento , Humanos , Articulación de la Rodilla/fisiopatología , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla/efectos adversos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Medición de Resultados Informados por el Paciente , Diseño de Prótesis , Análisis Radioestereométrico/métodos , Tibia/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA