1.
J Peripher Nerv Syst ; 29(2): 262-274, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38860315

RESUMEN

BACKGROUND: Loss-of-function variants in MME (membrane metalloendopeptidase) are a known cause of recessive Charcot-Marie-Tooth Neuropathy (CMT). A deep intronic variant, MME c.1188+428A>G (NM_000902.5), was identified through whole genome sequencing (WGS) of two Australian families with recessive inheritance of axonal CMT using the seqr platform. MME c.1188+428A>G was detected in a homozygous state in Family 1, and in a compound heterozygous state with a known pathogenic MME variant (c.467del; p.Pro156Leufs*14) in Family 2. AIMS: We aimed to determine the pathogenicity of the MME c.1188+428A>G variant through segregation and splicing analysis. METHODS: The splicing impact of the deep intronic MME variant c.1188+428A>G was assessed using an in vitro exon-trapping assay. RESULTS: The exon-trapping assay demonstrated that the MME c.1188+428A>G variant created a novel splice donor site resulting in the inclusion of an 83 bp pseudoexon between MME exons 12 and 13. The incorporation of the pseudoexon into MME transcript is predicted to lead to a coding frameshift and premature termination codon (PTC) in MME exon 14 (p.Ala397ProfsTer47). This PTC is likely to result in nonsense mediated decay (NMD) of MME transcript leading to a pathogenic loss-of-function. INTERPRETATION: To our knowledge, this is the first report of a pathogenic deep intronic MME variant causing CMT. This is of significance as deep intronic variants are missed using whole exome sequencing screening methods. Individuals with CMT should be reassessed for deep intronic variants, with splicing impacts being considered in relation to the potential pathogenicity of variants.


Asunto(s)
Enfermedad de Charcot-Marie-Tooth , Metaloendopeptidasas , Empalme del ARN , Adulto , Femenino , Humanos , Masculino , Enfermedad de Charcot-Marie-Tooth/genética , Intrones , Metaloendopeptidasas/genética , Mutación , Linaje
2.
Am J Dent ; 33(4): 213-217, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32794397

RESUMEN

PURPOSE: To perform a clinical and radiographic evaluation comparing Filtek Bulk Fill high viscosity bulk-fill resins with Filtek Z350 XT nanoparticulate for 1 year. METHODS: 58 restorations were performed for each material (bulk-fill and nanoparticulate), for a total of 116 restorations. Among these, 42 Class I and 16 Class II restorations were performed for each group, in molars and premolars. Clinical evaluation was performed 7 days (baseline), 6 months and 1 year after restorations, using the World Dental Federation (FDI) criteria. Radiographs were obtained at 7 days and 1 year after the restoration was placed and the radiopacity was measured using Image J software at the same time interval. RESULTS: Of the 70 restorations available for evaluation at 1 year, the Mann-Whitney and Friedman tests showed no statistically significant difference for the FDI criteria analyzed. Greater radiopacity was observed for bulk-fill resin compared to nanoparticulate (two-way ANOVA, P= 0.022). This same test showed no difference in radiopacity between the groups in the two evaluation periods (P= 0.062). The high viscosity bulk-fill resin composite presented similar clinical performance to nanoparticulate resin in this evaluation period and higher radiopacity was observed for this material when compared to nanoparticulate resin, in both time periods. CLINICAL SIGNIFICANCE: The high viscosity bulk-fill resin composite showed similar performance to the nanoparticulate resin during the evaluation period of 1 year. Radiopacity showed high values for the bulk-fill resin when compared to nanoparticulate resin. The bulk-fill resin has potential to be used in posterior teeth.


Asunto(s)
Materiales Dentales , Restauración Dental Permanente , Diente Premolar , Resinas Compuestas , Diente Molar , Viscosidad
3.
J Esthet Restor Dent ; 32(3): 325-332, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31622014

RESUMEN

OBJECTIVE: To evaluate the influence of the degree of dentin moisture on interfacial ultramorphology and bond strength (µTBS) of universal adhesives. MATERIALS AND METHODS: Futurabond U (FBU), Scotchbond Universal (SBU), Adhese Universal (ADU), and Prime&Bond active (PBA) were used. After acid-etching, moist or over-dried dentin surfaces were tested. Teeth were restored for scanning and transmission electron microscopy (n = 3) and µTBS evaluation (n = 5). µTBS results were analyzed by two-way ANOVA and Tukey. RESULTS: For moist dentin, a well-formed hybrid layer (HL) was observed. However, when applied to over-dried dentin, remarkable differences were observed. Defects, gaps, and reduced HL thickness were observed mainly for ADU and FBU. When applied to wet dentin, µTBS values were similar for all adhesives, except for FBU, which was significantly lower. When applied to over-dried dentin, PBA presented the highest µTBS values, followed by SBU, ADU, and FBU. ADU presented significantly lower µTBS when applied to over-dried dentin. CONCLUSION: PBA, SBU, and FBU µTBS values were not sensitive to the degree of moisture. Even though application to over-dried dentin revealed defects, gaps and reduced HL thickness for SBU, ADU, and FBU, µTBS analysis only revealed a significant reduction for ADU. CLINICAL SIGNIFICANCE: Universal adhesives can be applied in either self-etching or etch-and-rinse mode. However, clinicians are not aware which universal adhesives should be strictly applied on a moist dentin for bonding in the etch-and-rinse mode.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Resinas Compuestas , Cementos Dentales , Dentina , Ensayo de Materiales , Cementos de Resina , Resistencia a la Tracción
4.
Neurogenetics ; 19(4): 215-225, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30039206

RESUMEN

Charcot-Marie-Tooth disease (CMT) represents a heterogeneous group of hereditary peripheral neuropathies. We previously reported a CMT locus on chromosome 19q13.3 segregating with the disease in a large Costa Rican family with axonal neuropathy and autosomal recessive pattern of inheritance (CMT2B2). We proposed a homozygous missense variant in the Mediator complex 25 (MED25) gene as causative of the disease. Nevertheless, the fact that no other CMT individuals with MED25 variants were reported to date led us to reevaluate the original family. Using exome sequencing, we now identified a homozygous nonsense variant (p.Gln517ter) in the last exon of an adjacent gene, the polynucleotide kinase 3'-phosphatase (PNKP) gene. It encodes a DNA repair protein recently associated with recessive ataxia with oculomotor apraxia type 4 (AOA4) and microcephaly, seizures, and developmental delay (MCSZ). Subsequently, five unrelated Costa Rican CMT2 subjects initially identified as being heterozygous for the same MED25 variant were found to be also compound heterozygote for PNKP. All were heterozygous for the same variant found homozygous in the large family and a second one previously associated with ataxia (p.Thr408del). Detailed clinical reassessment of the initial family and the new individuals revealed in all an adult-onset slowly progressive CMT2 associated with signs of cerebellar dysfunction such as slurred speech and oculomotor involvement, but neither microcephaly, seizures, nor developmental delay. We propose that PKNP variants are the major causative variant for the CMT2 phenotype in these individuals and that the milder clinical manifestation is due to an allelic effect.


Asunto(s)
Enfermedad de Charcot-Marie-Tooth/genética , Enzimas Reparadoras del ADN/genética , Complejo Mediador/genética , Fosfotransferasas (Aceptor de Grupo Alcohol)/genética , Adulto , Sustitución de Aminoácidos/genética , Estudios de Casos y Controles , Consanguinidad , Costa Rica , Análisis Mutacional de ADN , Enzimas Reparadoras del ADN/química , Familia , Femenino , Predisposición Genética a la Enfermedad , Humanos , Masculino , Persona de Mediana Edad , Modelos Moleculares , Mutación Missense , Linaje , Fosfotransferasas (Aceptor de Grupo Alcohol)/química , Polimorfismo de Nucleótido Simple
5.
J Esthet Restor Dent ; 30(4): 346-351, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29766651

RESUMEN

OBJECTIVE: To test the effects of different adhesive protocols and silane application on the adhesive durability to a Lithium Disilicate reinforced glass ceramic. METHODS: Forty disks of 13 mm diameter (E.max Press) were used. After etching with 9.5% HF for 20 seconds, disks were randomly assigned into 4 groups according to the adhesive/silane protocol: silane application only (SIL); silane application followed by adhesive (SILXP-XP Bond); silane-containing adhesive (SBU-ScotchBond Universal); silane application followed by silane-containing adhesive (SILSBU). Four resin composite cylinders of 1-mm diameter and 3-mm height were made on each ceramic disk and tested in shear. Specimens were stored in water for 24 hours or 12 months prior to testing. Results were statistically analyzed by two-way ANOVA and Tukey test. RESULTS: After 24 hours, the highest SBS values were observed for SILXP and SILSBU. However, after 12 months, SILXP and SILSBU presented a significant reduction in SBS, while the highest SBS were observed for SIL. For SBU, no significant reduction in SBS was observed, however, it showed the lowest SBS after 12 months. CONCLUSIONS: Regardless of the presence of silane in the composition of SBU, previous silane application is still recommended prior to cementation of Lithium Disilicate. CLINICAL SIGNIFICANCE: The application of silane as a separate step is recommended prior to cementation of Lithium Disilicate reinforced glass-ceramic, independent of the presence of silane within the universal adhesive solution.


Asunto(s)
Recubrimiento Dental Adhesivo , Silanos , Cerámica , Cementos Dentales , Porcelana Dental , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie
6.
Clin Oral Investig ; 21(5): 1707-1715, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27714528

RESUMEN

OBJECTIVES: This study aimed to evaluate the ultramorphological characteristics of tooth-resin interfaces and the bond strength (BS) of multimode adhesive systems to enamel and dentin. METHODS: Multimode adhesives (Scotchbond Universal (SBU) and All-Bond Universal) were tested in both self-etch and etch-and-rinse modes and compared to control groups (Optibond FL and Clearfil SE Bond (CSB)). Adhesives were applied to human molars and composite blocks were incrementally built up. Teeth were sectioned to obtain specimens for microtensile BS and TEM analysis. Specimens were tested after storage for either 24 h or 1 year. SEM analyses were performed to classify the failure pattern of beam specimens after BS testing. RESULTS: Etching increased the enamel BS of multimode adhesives; however, BS decreased after storage for 1 year. No significant differences in dentin BS were noted between multimode and control in either evaluation period. Storage for 1 year only reduced the dentin BS for SBU in self-etch mode. TEM analysis identified hybridization and interaction zones in dentin and enamel for all adhesives. Silver impregnation was detected on dentin-resin interfaces after storage of specimens for 1 year only with the SBU and CSB. CONCLUSIONS: Storage for 1 year reduced enamel BS when adhesives are applied on etched surface; however, BS of multimode adhesives did not differ from those of the control group. In dentin, no significant difference was noted between the multimode and control group adhesives, regardless of etching mode. CLINICAL RELEVANCE: In general, multimode adhesives showed similar behavior when compared to traditional adhesive techniques. Multimode adhesives are one-step self-etching adhesives that can also be used after enamel/dentin phosphoric acid etching, but each product may work better in specific conditions.


Asunto(s)
Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/química , Esmalte Dental/química , Agua/química , Grabado Ácido Dental , Resinas Compuestas , Humanos , Técnicas In Vitro , Ensayo de Materiales , Metacrilatos , Microscopía Electrónica , Diente Molar , Cementos de Resina , Propiedades de Superficie , Resistencia a la Tracción
7.
J Esthet Restor Dent ; 29(2): 118-127, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27925387

RESUMEN

PURPOSE: This study aimed to quantify polymerization shrinkage of one conventional and three bulk-fill composites, under bonded and unbonded conditions, in Class II preparations using 3D microcomputed tomography (µCT) and report its location. MATERIALS AND METHODS: Preparations (2.5 mm occlusal depth × 4 mm wide × 4 mm mesial box and 1 mm beyond the CEJ distal box depth) were made in 48 human extracted molars (n = 6). Four composites were tested, one regular (Vitalescence/VIT) and three bulk-fill: SureFil SDR Flow (SDR), Tetric EvoCeram Bulk Fill (TET), and Filtek flowable Bulk Fill (FIL). Teeth were divided into four groups according to restorative material used and subdivided into two subgroups, according to the presence of an adhesive system (XP Bond) application (bonded [-B]) or its absence (unbonded [-U]). Each tooth was scanned three times: (1) after cavity preparation, (2) before and (3) after composite light-curing. Acquired µCT images were imported into 2D and 3D software for analysis. RESULTS: Significantly different volumetric shrinkage between bonded and unbonded conditions was observed only for TET group (p < 0.05), unbonded presenting significantly higher volumetric shrinkage. Among the bonded groups, TET-B presented significantly lower shrinkage than both SDR-B and FIL-B but not significantly different from VIT-B. Generally, shrinkage occurred at occlusal and distal surfaces. CONCLUSIONS: When applied to bonded Class II cavities, TET exhibited significantly lower volumetric shrinkage compared to the other bulk-fill composites. However, it also exhibited the highest difference of volumetric shrinkage values between unbonded and bonded cavities. CLINICAL SIGNIFICANCE: Volumetric polymerization shrinkage occurred with all composites tested, regardless of material type (conventional or bulk-fill) or presence or absence of bonding. However, volumetric shrinkage has been reduced or at least maintained when bulk-fill composites were used compared to a conventional composite resin, which makes them a potential time saving alternative for clinicians. (J Esthet Restor Dent 29:118-127, 2017).


Asunto(s)
Caries Dental/diagnóstico por imagen , Caries Dental/patología , Microtomografía por Rayos X/métodos , Resinas Compuestas/química , Humanos , Polimerizacion
8.
J Adhes Dent ; 17(5): 427-32, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26525007

RESUMEN

PURPOSE: To evaluate the microtensile bond strength (µTBS) of a bulk-fill low-stress resin-based composite to dentin from gingival walls of Class II MOD cavities. MATERIALS AND METHODS: Class II MOD cavities were prepared in 44 human molars with the distal and mesial proximal boxes 4 and 6 mm deep, respectively. Eight experimental groups (n = 11) were obtained by a factorial design including 1. "composite" in two levels: a bulk-fill low-stress composite (SureFil SDR Flow, Dentsply Caulk) and a conventional composite (Filtek Z350 XT, 3M ESPE); 2. "filling technique" in two levels: bulk-fill (Bf) and incremental (In); and 3. "depth" in two levels: 4 mm and 6 mm in order to create different polymerization conditions. Twenty-four hours after placement of restorations, teeth were sectioned into beams with a cross-sectional bonded area of approximately 1 mm2. Bonded beams obtained from the gingival walls of the proximal boxes were tested in tension at a crosshead speed of 1 mm/min. Data were submitted to a 3-way ANOVA followed by a post-hoc Tukey's test (p < 0.05). RESULTS: ANOVA failed to identify significant differences for the triple and double interaction between factors. However, significant differences were observed for the factors "composite" and "filling technique" (p < 0.05). SDR presented significantly higher µTBS values for bulk and incremental filling techniques (p < 0.05), and the incremental filling technique presented significantly higher µTBS values for both composites (p < 0.05). CONCLUSION: It can be concluded that the bulk-fill flowable composite SDR may improve the bond strength to the gingival walls of Class II MOD cavities.


Asunto(s)
Resinas Compuestas/química , Recubrimiento Dental Adhesivo , Preparación de la Cavidad Dental/clasificación , Materiales Dentales/química , Grabado Ácido Dental/métodos , Luces de Curación Dental , Análisis del Estrés Dental/instrumentación , Dentina/ultraestructura , Recubrimientos Dentinarios/química , Humanos , Ensayo de Materiales , Bandas de Matriz , Nanocompuestos/química , Polimerizacion , Estrés Mecánico , Propiedades de Superficie , Resistencia a la Tracción
9.
J Med Genet ; 50(12): 838-47, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24092917

RESUMEN

BACKGROUND: Borjeson-Forssman-Lehmann syndrome (BFLS) is an X-linked recessive intellectual disability (ID) disorder caused by mutations in the PHF6 gene and characterised by variable cognitive impairment, a distinct facial gestalt, obesity, and hypogonadism. Female carriers are usually not affected or only mildly affected, and so far only two females with de novo mutations or deletions in PHF6 have been reported. METHODS AND RESULTS: We performed PHF6 mutational analysis and screening for intragenic deletions and duplications by quantitative real-time PCR and multiplex ligation dependent probe amplification (MLPA) in female patients with variable ID and a distinct appearance of sparse hair, remarkable facial features, hypoplastic nails, and teeth anomalies. We detected two truncating mutations and two duplications of exons 4 and 5. Furthermore, two female patients with PHF6 deletions and a similar phenotype were identified by routine molecular karyotyping. Recently, two patients with a clinical diagnosis of Coffin-Siris syndrome in early infancy had been found to harbour mutations in PHF6, and their phenotype in advanced ages is now described. Further studies revealed skewed X-inactivation in blood lymphocytes, while it was normal in fibroblasts, thus indicating functional mosaicism. CONCLUSIONS: Our findings indicate that de novo defects in PHF6 in females result in a recognisable phenotype which might have been under-recognised so far and which comprises variable ID, a characteristic facial gestalt, hypoplastic nails, brachydactyly, clinodactyly mainly of fingers IV and V, dental anomalies, and linear skin hyperpigmentation. It shows overlap with BFLS but also additional distinct features, thus adding a new facet to this disorder.


Asunto(s)
Proteínas Portadoras/genética , Epilepsia/genética , Cara/anomalías , Dedos/anomalías , Trastornos del Crecimiento/genética , Hipogonadismo/genética , Discapacidad Intelectual Ligada al Cromosoma X/genética , Mutación/genética , Obesidad/genética , Adolescente , Adulto , Niño , Análisis Mutacional de ADN , Epilepsia/patología , Cara/patología , Femenino , Dedos/patología , Pie/patología , Trastornos del Crecimiento/patología , Mano/patología , Humanos , Hipogonadismo/patología , Discapacidad Intelectual Ligada al Cromosoma X/patología , Obesidad/patología , Fenotipo , Proteínas Represoras , Adulto Joven
10.
Lasers Med Sci ; 28(4): 1069-76, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22886136

RESUMEN

UNLABELLED: This study evaluated the effects of different parameters of dentin irradiation with erbium -doped yttrium aluminum garnet (Er:YAG) laser on bond strength to dentin and analyzed the ultramorphological characteristics of resin-laser-irradiated dentin interfaces using a transmission electron microscope (TEM). Dentin surfaces were abraded with SiC paper (600 grit) or Er:YAG laser-irradiated (120/4, 140/6, 180/4, or 200/6 mJ/Hz). Three adhesive systems were tested: Single Bond Plus (3M ESPE), Clearfil Protect Bond (Kuraray Med.), and Clearfil Tri-S Bond (Kuraray Med.). Treatments were performed over flat dentin surfaces of human third molars. Specimens were stored in distilled water for 1 week or 6 months and prepared for a microtensile bond strength test and interfacial ultrastructure for analysis. Microtensile bond strength data (n = 5) were analyzed with three-way analysis of variance. Irradiation with Er:YAG laser did not reduce the bond strength values for self-etching adhesives even after 6 months of water storage. The hybrid layer formation was observed only when the adhesives were applied to non-irradiated dentin (control group). Nanoleakage occurred in all resin-dentin interfaces using Single Bond Plus for both periods. Nanoleakage pattern and bond strength of self-etching adhesives to dentin were less affected by Er:YAG laser irradiation and by the 6-month storage in water than was those of the etch-and-rinse adhesive. TEM analysis revealed no hybridization when dentin was laser-irradiated. CLINICAL SIGNIFICANCE: Minimally invasive caries removal has been proposed. Nevertheless, bonding mechanisms to lased dentin are not entirely described. Knowing the interaction between the treated dentin and bonding agents and its behavior over time is of utmost importance for new technologies. Regarding that, two-bottle self-etching adhesive system provided a more consistent evidence of its better behavior when bonding to lased substrate.


Asunto(s)
Dentina/efectos de la radiación , Láseres de Estado Sólido/uso terapéutico , Curación por Luz de Adhesivos Dentales/métodos , Cementos Dentales/uso terapéutico , Grabado Dental/métodos , Dentina/ultraestructura , Humanos , Microscopía Electrónica de Transmisión , Resinas Sintéticas/uso terapéutico , Propiedades de Superficie , Resistencia a la Tracción , Factores de Tiempo
11.
Am J Dent ; 26(6): 335-40, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24640438

RESUMEN

PURPOSE: To determine the bond strength, nanoleakage and interfacial morphology of four self-etch adhesives bonded to superficial dentin. METHODS: Microtensile (MT) (n= 15) and single plane shear (SP) (n= 8) bond tests were performed using human dentin polished through 320-grit SiC paper. Clearfil Protect Bond (PB), Clearfil S3 Bond (S3), Prompt L-Pop (PLP) and G-Bond (GB) were used according to their manufacturers' instructions. Composite was applied as cylinders with a thickness of 4 mm with a 1 mm diameter and stored in water at 370C for 24 hours. Specimens were debonded with a testing machine at a cross-head speed of 1 mm/minute. Means and standard deviations of bond strength were calculated. Data were analyzed using ANOVA. Fisher's PLSD intervals were calculated at the 0.05 level of significance. Failure modes were determined at x100. The hybrid layer was revealed by treatment with 5N HC1/5% NaOCl or fractured perpendicular to the interface and sputter coated with gold. Specimens were viewed at x1,000, x2,500, and x5,000 in a field emission SEM at 15 kV. Teeth (n=2) sectioned into 0.9 mm-thick slabs were immersed in ammoniacal silver nitrate solution for 24 hours, rinsed and immersed in photo-developing solution for 8 hours. Specimens were sectioned (90 nm-thick) and observed under TEM. RESULTS: Means ranged from 25.0 to 73.1 MPa for MT and from 15.5 to 56.4 MPa for SP. MT values were greater than SP, but were highly correlated (R2 = 0.99, P= 0.003) and provided the same order for the systems studied. Fisher's PLSD intervals (P< 0.05) for bond strength techniques and adhesives results were 1.7 and 2.3 MPa, respectively. Failures sites were mixed. TEM showed that hybrid layers were -0.5 pm for PB, GB and S3 and approximately 5 microm for PLP. SEM showed morphologic differences among adhesives. Silver nitrate deposits were observed within the interfaces for all adhesive systems.


Asunto(s)
Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios/química , Resinas Compuestas/química , Filtración Dental/clasificación , Materiales Dentales/química , Análisis del Estrés Dental/instrumentación , Dentina/ultraestructura , Humanos , Ensayo de Materiales , Metacrilatos/química , Microscopía Electrónica de Rastreo , Microscopía Electrónica de Transmisión , Cementos de Resina/química , Resistencia al Corte , Tinción con Nitrato de Plata , Estrés Mecánico , Propiedades de Superficie , Temperatura , Resistencia a la Tracción , Factores de Tiempo , Agua/química
12.
Odontology ; 101(1): 52-9, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22438086

RESUMEN

This study aimed to evaluate the effect of the previous application of a casein phosphopeptide-amorphous calcium phosphate paste (MI Paste, MI) and adhesive systems on the bond durability of a fissure sealant. Ninety-eight enamel blocks were obtained from proximal surfaces of erupted third molars. Specimens were divided into 14 groups (n = 7) according to the previous application of MI (with and without) and the adhesive systems used (no adhesive system; hydrophobic resin of a three-step etch-and-rinse adhesive system; etch-and-rinse single-bottle adhesive system; all-in-one adhesive system; two-step self-etching adhesive system; additional phosphoric acid conditioning and all-in-one adhesive system; additional phosphoric acid conditioning and two-step self-etching adhesive system). A fissure sealant (Fluroshield) was applied and photoactivated for 20 s. Beams (~0.7 mm(2)) were prepared for the microtensile bond strength test, which was executed after 24 h or 6 months of water storage. Fractured specimens were analyzed by scanning electronic microscopy. Data were analyzed by two-way ANOVA with repeated measures/Tukey's test (P < 0.05). Groups that received MI application and adhesive systems presented higher means than those groups where MI was not applied. Higher frequency of cohesive failures was observed for groups with MI. Applying a CPP-ACP containing paste on enamel before adhesive systems was an effective method to increase bond durability of the sealant tested.


Asunto(s)
Caseínas/química , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/química , Esmalte Dental/efectos de los fármacos , Selladores de Fosas y Fisuras/química , Análisis de Varianza , Grabado Dental/métodos , Fracaso de la Restauración Dental , Humanos , Tercer Molar , Resistencia a la Tracción
13.
J Adhes Dent ; 25(1): 71-78, 2023 Mar 20.
Artículo en Inglés | MEDLINE | ID: mdl-36939646

RESUMEN

PURPOSE: To evaluate the effects of etching mode (self-etch and etch-and-rinse) on acid-base resistant zone (ABRZ) formation at the resin cement/enamel interface and enamel etching pattern, as well as the effects of thermocycling (0, 5000, and 10,000 cycles) on the enamel microshear bond strength (µSBS) mediated by dual-cure resin cements (DCRC). MATERIALS AND METHODS: Two DCRC were used in 4 groups: Panavia V5 in self-etch (V5NE) and etch-and-rinse mode (V5E); and Estecem II in self-etch (ENE) and etch-and-rinse mode (EE). For ABRZ observation, the bonded interface was subjected to a demineralizing solution. The morphological attributes of the interface and etching patterns were observed using FE-SEM. For µ-SBS, cylinders with a 0.79-mm internal diameter and 0.5-mm height were made with DCRC and tested in shear after 0, 5000, and 10,000 thermal cycles (TC) (5°C and 55°C) (n = 10). RESULTS: The formation of an enamel ABRZ was observed in all groups with different morphological features between self-etch and etch-and-rinse groups. A funnel-shaped erosion beneath the interface was present using V5NE and ENE modes where enamel was dissolved, while ABRZ formation was confirmed and no funnel-shaped erosion was noticed using V5E and EE. No significant differences in µSBS were observed between resin cements. However, significantly lower µSBSs were recorded when the self-etching mode was used. Thermocycling resulted in a significant reduction in µSBS for all groups. CONCLUSION: Selective enamel etching should be recommended to improve the interfacial quality when dual-cure resin luting cements are used.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Cementos de Resina/química , Grabado Ácido Dental/métodos , Recubrimiento Dental Adhesivo/métodos , Esmalte Dental , Ácidos Fosfóricos/química , Ensayo de Materiales , Resistencia al Corte , Recubrimientos Dentinarios/química
14.
Lasers Med Sci ; 27(1): 31-8, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20859649

RESUMEN

The objective of this study was to evaluate the influence of Er:YAG laser (λ = 2.94 µm) on microtensile bond strength (µTBS) and superficial morphology of bovine dentin bleached with 16% carbamide peroxide. Forty bovine teeth blocks (7 × 3 × 3 mm(3)) were randomly assigned to four groups: G1- bleaching and Er:YAG irradiation with energy density of 25.56 J/cm(2) (focused mode); G2 - bleaching; G3 - no-bleaching and Er:YAG irradiation (25.56 J/cm(2)); G4 - control, non-treated. G1 and G2 were bleached with 16% carbamide peroxide for 6 h during 21 days. Afterwards, all blocks were abraded with 320 to 600-grit abrasive papers to obtain flat standardized dentin surfaces. G1 and G3 were Er:YAG irradiated. Blocks were immediately restored with 4-mm-high composite resin (Adper Single Bond 2, Z-250-3 M/ESPE). After 24 h, the restored blocks (n = 9) were serially sectioned and trimmed to an hour-glass shape of approximately 1 mm(2) at the bonded interface area, and tested in tension in a universal testing machine (1 mm/ min). Failure mode was determined at a magnification of 100× using a stereomicroscope. One block of each group was selected for scanning electron microscope (SEM) analysis. µTBS data was analyzed by two-way ANOVA and Tukey test (α = 0.05). Mean bond strengths (SD) in MPa were: G1- 32.7 (5.9)(A); G2- 31.1 (6.3)(A); G3- 25.2 (8.3)(B); G4- 36.7 (9.9).(A) Groups with different uppercase letters were significantly different from each other (p < .05). Enamel bleaching procedure did not affect µTBS values for dentin adhesion. Er:YAG laser irradiation with 25.56 J/cm(2) prior to adhesive procedure of bleached teeth did not affect µTBS at dentin and promoted a dentin surface with no smear layer and opened dentin tubules observed under SEM. On the other hand, Er:YAG laser irradiation prior to adhesive procedure of non-bleached surface impaired µTBS compared to the control group.


Asunto(s)
Resinas Compuestas/efectos de la radiación , Recubrimiento Dental Adhesivo , Dentina/efectos de la radiación , Láseres de Estado Sólido , Resistencia a la Tracción , Animales , Peróxido de Carbamida , Bovinos , Esmalte Dental/efectos de los fármacos , Esmalte Dental/efectos de la radiación , Dentina/ultraestructura , Microscopía Electrónica de Rastreo , Peróxidos/farmacología , Cementos de Resina/efectos de la radiación , Blanqueamiento de Dientes , Urea/análogos & derivados , Urea/farmacología
15.
J Adhes Dent ; 14(3): 251-63, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22282747

RESUMEN

PURPOSE: This study evaluated the effects of peripheral enamel margins on the long-term bond strength (µTBS) and nanoleakage in resin/dentin interfaces produced by self-adhesive and conventional resin cements. MATERIALS AND METHODS: Five self-adhesive [RelyX-Unicem (UN), RelyX-U100 (UC), GCem (GC), Maxcem (MC), Set (SET)] and 2 conventional resin cements [RelyX-ARC(RX), Panavia F(PF)] were used. An additional group included the use of a two-step self-etching adhesive (SE Bond) with Panavia F (PS). One hundred ninety-two molars were assigned to 8 groups according to luting material. Five-mm-thick composite disks were cemented and assigned to 3 subgroups according to water-exposure condition (n = 6): 24-h peripheral exposure (24h-PE-enamel margins), or 1 year of peripheral (1 yr-PE) or direct exposure (1 yr-DE-dentin margin). Restored teeth were sectioned into beams and tested in tension at 1 mm/min. Data were analyzed by two-way ANOVA and Tukey's test. Two additional specimens in each group were prepared for nanoleakage evaluation. Nanoleakage patterns were observed under SEM/TEM. RESULTS: Except for RX, no significant reduction in µTBS was observed between 24h-PE and 1 yr-PE. 1 yr-DE reduced µTBS for RX, PF, GC, MC, and SET. No significant reduction in µTBS was observed for PS, UC, and UN after 1 year. After 1 yr-DE, RX and PS presented the highest µTBS, and SET and MC the lowest. Nanoleakage was reduced when there was a peripheral enamel margin. SET and MC presented more silver deposition than other groups. CONCLUSION: The presence of a peripheral enamel margin reduced the degradation rate in resin/dentin interfaces for most materials. The µTBS values produced by the multi-step luting agents RX and PS were significantly higher than those observed for self-adhesive cement.


Asunto(s)
Recubrimiento Dental Adhesivo , Filtración Dental , Cementos de Resina/química , Análisis de Varianza , Resinas Compuestas , Recubrimiento Dental Adhesivo/métodos , Esmalte Dental , Análisis del Estrés Dental , Dentina , Humanos , Ensayo de Materiales , Microscopía Electrónica , Diente Molar , Estadísticas no Paramétricas , Resistencia a la Tracción , Agua
16.
Acta Odontol Scand ; 70(6): 478-84, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22150012

RESUMEN

OBJECTIVE: This study evaluated the effects of filler addition, storage medium and time on biaxial flexural strength and flexural modulus of six adhesive systems. MATERIALS AND METHODS: The adhesives were either unfilled resins: Single Bond, Prime&Bond 2.1 and One-Step; or filled resins: Single Bond Plus, Prime&Bond NT and One-Step Plus. Resin discs of each product (0.5 mm thick × 6.0 mm diameter) were prepared using silicon molds (n = 10). The discs were stored dry, in water, mineral oil or ethanol for 1 week or 3 months before biaxial flexural testing. Data were statistically analyzed by 3-way ANOVA and Tukey's post-hoc test (α = 0.05). The specimens were tested in a universal testing machine at 1.27 mm/min until failure occurred. RESULTS: In general, the storage in ethanol led to significantly lower flexural strength and flexural modulus values than the other storage conditions for all adhesives in both storage periods. Filler addition increased flexural strength and flexural modulus for Prime&Bond NT, when it was stored dry or in water for 1 week. For Single Bond Plus, the filler addition resulted in higher flexural modulus, when it was stored for 1 week in oil and in ethanol. No significant differences in flexural modulus were observed between One-Step and One-Step Plus in any storage medium. CONCLUSIONS: Results suggested that filler addition does not necessarily have to increase the flexural strength and flexural modulus. Ethanol and oil storages tended to yield opposite effects.


Asunto(s)
Cementos Dentales , Ensayo de Materiales , Análisis de Varianza
17.
J Contemp Dent Pract ; 13(4): 464-71, 2012 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-23151694

RESUMEN

AIM: The aim of this study was to analyze and compare the influence of short-term NaOCl-storage and long-term water storage on the microtensile bond strength (µTBS) of etch-and-rinse adhesive system to human dentin. MATERIALS AND METHODS: Thirty-six third human molars were randomly divided into 6 groups (n = 6) according to the aging protocol: G1 (water, 24 hours); G2 (water, 6 months); G3 (water, 12 months); G4 (10% sodium hypochlorite--NaOCl, 1 hour); G5 (10% NaOCl, 3 hours) and G6 (10% NaOCl, 5 hours). A two-step etch-and-rinse adhesive (Adper Single Bond 2) was applied according to the manufacturers' instructions. A composite (Filtek Z250) was applied in four horizontal increments and was individually cured. Specimens were cut following the microtensile test technique, submitted to the different aging protocols, and tested in tension. The fracture pattern was observed in a stereomicroscope (40* magnification) and in a scanning electron microscope. The µTBS data were analyzed by ANOVA and Tukey's test (α = 0.05). RESULTS: The effect of storage in 10% NaOCl for 1 or 3 hours was not significantly different from that of aging in distilled water (DW) for 6 or 12 months (p > 0.05). Beams immersed in DW for 24 hours and in 10% NaOCl for 5 hours showed the highest and lowest µTBS values respectively. CONCLUSION: The aging protocols negatively influenced dentin bond strength. Aging specimens in 10% NaOCl for 1 or 3 hours can be an alternative method for long-term water storage (6 or 12 months) bond strength studies. CLINICAL SIGNIFICANCE: This aging protocol allows a quick achievement of longitudinal bond strength data, so that results are available to the professionals in this area while the materials are yet present at the dental market.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos Dentales , Recubrimientos Dentinarios/química , Almacenaje de Medicamentos , Cementos de Resina/química , Análisis de Varianza , Resinas Compuestas , Humanos , Inmersión , Hipoclorito de Sodio , Estadísticas no Paramétricas , Resistencia a la Tracción , Factores de Tiempo , Agua
18.
Microsc Res Tech ; 85(8): 2943-2952, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35557015

RESUMEN

This study evaluated the effects of Erbium-doped yttrium aluminium garnet (Er:YAG) laser settings and dentin bonding agents on ultramorphological characteristics of resin-laser-irradiated dentin interfaces and dentin bond strength (BS) of these adhesive systems. Additionally, dentin depth affected by Er:YAG laser irradiations was measured. The experiments were performed on occlusal dentin surfaces of third molars that were flattened with 600-grit SiC sandpaper. Treated-dentin with laser settings (250 mJ/4 Hz and 160 mJ/10 Hz) were the experimental groups, while SiC abraded dentin was the control. These three dentin treatments and three adhesives (two self-etchings and one etch-&-rinse adhesive) formed nine groups for the ultramorphology of laser-ablated dentin-adhesives interfacial analysis, using a transmission electron microscope (TEM). For BS (n = 8), the same nine groups were tested with addition of the two evaluation times (24 h after sample preparation or 1 year). The depths of Er:YAG laser effects into the dentin were measured using a TEM (n = 10). Ablated-dentin depth and BS data were analyzed by one- and three-way ANOVA, respectively, and Tukey's test (α = 0.05). Hybrid layer formation was only observed for controls, while for laser-treated dentin, adhesives were bonded to dentin with resin tags formation. Laser settings reduced the BS for all adhesives at 24 h, while at 1 year, etch-&-rinse adhesive presented the highest BS, regardless treatment (control or laser settings). Dentin depth affected by laser settings was similar. The laser irradiation altered the bonding mechanism of the adhesives to dentin and reduced the BS for self-etching adhesives. Etch-&-rinse adhesive yielded the highest BS at 1 year. Laser settings similarly affected the dentin in depth. HIGHLIGHTS: Er:YAG laser irradiation settings produced similar effects on depth and bond strength to dentin. The etch-&-rinse adhesive yielded the highest dentin bond strength regardless of the type of dentin treatment at 1 year.


Asunto(s)
Recubrimiento Dental Adhesivo , Láseres de Estado Sólido , Adhesivos/análisis , Dentina/química , Recubrimientos Dentinarios/química , Erbio , Láseres de Estado Sólido/uso terapéutico , Cementos de Resina/química , Resistencia a la Tracción
19.
J Clin Exp Dent ; 14(6): e492-e498, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35765356

RESUMEN

Background: The use of dental headlights is a common practice to better illuminate the operatory field and achieve excellence in restorative dentistry. However, visible light-cured dental materials can have reduced working time under headlight illumination. The aim of this study was to evaluate the influence of the spectral irradiance power of two dental headlights on the degree of polymerization and working time of light-curable dental composites. Material and Methods: Two headlights, StarLight Nano 3 (StarMed) (SN) and Zeon Endevour XL (Orascoptic) (ZE) were characterized using a spectrophotometer coupled to an integrating sphere (MARC® Light Collector, BlueLight Analytics). The degree of conversion of the two composites, Filtek Supreme (3M) and Tetric Prime (Ivoclar Vivadent), was evaluated using an FTIR spectroscope (NicoletTM iS20, Thermo Fisher). Results: Both headlights emitted a significant amount of blue light. The Zeon headlamp without filter emitted a broader spectrum with lower blue intensity and higher CRI than the White LED of the Nano 3. The Zeon headlamp with the blue blocking filter emitted a broader spectrum than the Orange LED of the Nano 3. There were no differences in the degree of conversion and working time of the Filtek Supreme and Tetric Prime composites when illuminated by the different headlamps. Both Zeon and the White LED of the Nano 3 were capable to cure the composites within only 5-10 minutes of irradiation. There were no changes in the degree of conversion of the composites when the Orange LED of the Nano 3 or the blue blocking filter of the Zeon were used. Conclusions: Both headlights reduced the working time of light-cured materials. The use of orange filters prevented the composite polymerization and maintained the working time. Key words:Surgical Headlight, degree of conversion, working time, light-curing.

20.
J Adhes Dent ; 24(1): 355-366, 2022 Sep 28.
Artículo en Inglés | MEDLINE | ID: mdl-36169267

RESUMEN

PURPOSE: To evaluate the kinetics of polymerization and shrinkage stress of resin cements, as well as their bond strength to dentin after 24-h or one-year water storage. MATERIALS AND METHODS: Three conventional resin cements were evaluated: RelyX Ultimate (RUL), Panavia V5 (PNV), and Multilink N (MLN); and three self-adhesive resin cements: RelyX Unicem 2 (RUN), Panavia SA Cement Plus (PSA), and G-CEM LinkAce (GCL). Degree of conversion (DC), maximum polymerization rate (RPmax) and gel time values were obtained using Fourier-transform infrared spectroscopy (FTIR/ATR). Shrinkage stress values were determined with a tensiometer, using a universal testing machine (n=5). Indirect resin composite restorations (Solidex) were fabricated and cemented to the dentin surface using self-adhesive resin cements, or conventional resin cements with self-etching adhesive (n=5). Bonding performance was evaluated with the microtensile bond strength (µTBS) test after 24 h or one year of water storage. RESULTS: MLN exhibited a higher DC (76.7%), whereas the percentage of other materials differed slightly (ranging from 54% to 58.5%). The RPmax and shrinkage stress values differed significantly between the cements. PSA showed the longest gel time. Significantly higher µTBS were observed for conventional resin cements after 24-h and one-year storage; a decrease in µTBS was observed for MLN only. CONCLUSION: Self-adhesive resin cements may not perform as well as conventional resin cements. Although both categories of cements presented similar polymerization kinetics and shrinkage values, the self-adhesive resin cements showed lower µTBS compared to those of conventional resin cements. Nevertheless, storage time only affected the bonding performance of MLN.


Asunto(s)
Recubrimiento Dental Adhesivo , Cementos de Resina , Recubrimiento Dental Adhesivo/métodos , Cementos Dentales/química , Análisis del Estrés Dental , Dentina , Recubrimientos Dentinarios/química , Ensayo de Materiales , Polimerizacion , Cementos de Resina/química , Resistencia a la Tracción , Agua/química
SELECCIÓN DE REFERENCIAS