Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Prosthet Dent ; 124(6): 738.e1-738.e8, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32694019

RESUMEN

STATEMENT OF PROBLEM: An intraradicular retainer formed by multiple independent glass fiber filaments was developed aiming to allow better adaptation in flattened root canals; however, the performance of the new posts is unclear. PURPOSE: The purpose of this in vitro study was to compare the bond strength (BS) and adhesive interface quality achieved in flattened root canals restored with conventional glass fiber posts (CFPs) and multifilament glass fiber posts (MFPs). MATERIAL AND METHODS: The distal roots of mandibular molars with long oval root canals were endodontically treated, and the obturation material was removed and assigned to 2 groups (n=11) according to the type of retainer used: CFP (WhitePostDC#0.5; FGM) or MFP (CometTail#4; Synca). The posts were cemented with self-adhesive resin cement. The specimens were sectioned (2 slices per third). The most cervical slice in each third was used to evaluate the BS, while the adhesive interface in the apical slices was analyzed by scanning electron microscopy. BS data were analyzed by using a multilevel generalized linear model, and adhesive interface SEM data were analyzed by using a multilevel ordinal logistic regression model (α=.05). RESULTS: Multilevel regression showed a statistically significant difference for the "type of retainer" factor (P=.001; CFP 2.61 ±1.30>MFP 1.59 ±1.54). No statistically significant differences were found for the "root thirds" factor (P=.346) or for the interaction of both factors (P=.114). The failure pattern was predominantly mixed or adhesive for CFP and adhesive to dentin for MFP. A better adaptation of the restorative material was observed in the cervical third for CFP and in the apical third for MFP (P<.001). CONCLUSIONS: MFP resulted in lower BS values than CFP, with a higher prevalence of adhesive failures to dentin and better adaptation of the adhesive interface in the apical third.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Cavidad Pulpar , Análisis del Estrés Dental , Dentina , Vidrio , Ensayo de Materiales , Cementos de Resina
2.
Am J Dent ; 31(4): 205-210, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30106537

RESUMEN

PURPOSE: To compare the fracture toughness of four different CAD/CAM materials, (VM) Vitablocs Mark II, (IP) IPS e.max CAD, (LU) LAVA Ultimate, and (VE) Vita Enamic under long thermocycling conditions. METHODS: Each type of ceramic block was sectioned into beams (n=9) with dimensions of 14×3×2.5 mm (L × W × H). All four ceramics were submitted to different conditions: the desiccator or distilled water, each for 7 days. The third and fourth conditions involved the specimens being submitted to 60,000 and 120,000 thermocycles in water respectively. The dwelling time was 52 seconds at 5° and 55°C. A three-point bend test with a universal loading machine on notched samples was per-formed. Furthermore, a fractographic analyses was made by scanning electron microscopy (SEM) to determine if any of these conditions influenced the type of fracture. Data were analyzed by two-way ANOVA (α= 0.05). RESULTS: A significant difference in fracture toughness (P< 0.05) was found among the groups; IP (4.20±1.23) had the highest value followed by VE (2.02±0.39), which did not have a statistically significant difference from LU (1.96±0.42). The lower value and statistical difference for VM was 1.52±0.35. The ceramics performed better after they were hydrated, while the polymer-based materials had the fracture toughness means decreased after the thermocycles. CLINICAL SIGNIFICANCE: A significant difference in fracture toughness (P<0.05) was found among the groups; IP had the highest value followed by VE, which was not statistically significantly different from LU. The ceramics performed better after they were hydrated, while the polymer-based materials had fracture toughness means decreased after thermocycling.


Asunto(s)
Diseño Asistido por Computadora , Porcelana Dental , Cerámica , Ensayo de Materiales
3.
Oral Health Prev Dent ; 14(4): 321-7, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27175446

RESUMEN

PURPOSE: To systematically examine mineralisation of healthy human enamel using Raman spectroscopy and provide an understanding of baseline variations that may be inherent in the healthy enamel from individual to individual as well as variations within a tooth. MATERIALS AND METHODS: Human teeth were obtained in compliance with the NIH guidelines. The teeth were collected fresh within the date of the extraction and kept moist at all times with wet tissue paper without any additional disinfecting treatment. The samples were individually wrapped in wet tissue paper and stored in a -20°C freezer. Prior to Raman analysis, the specimens were thawed at room temperature for 30 min. A Raman microscope was employed with a 10X objective used to focus the laser light (785 nm). Raman spectroscopy scores were validated by microcomputed tomography (µCT) on the two teeth which had the highest and lowest mineralisation found in the Raman scans. RESULTS: Mineralisation levels varied substantially between individuals. The highest Raman-based mineralisation intensity was about 5-fold greater than the lowest mineralisation score. Incisor mineralisation also varied dramatically depending on different sites on the tooth. CONCLUSIONS: Clinically applicable non-invasive techniques such as Raman spectroscopy that can quantify mineral content, such as Raman spectroscopy, may help answer whether or not mineralisation is associated with caries risk.


Asunto(s)
Densidad Ósea , Esmalte Dental/química , Esmalte Dental/fisiología , Espectrometría Raman , Humanos , Tomografía Computarizada por Rayos X
4.
J Adhes Dent ; 25(1): 117-124, 2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37191673

RESUMEN

PURPOSE: EDC (1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride) can increase dentin bonding longevity. This study aimed to evaluate the effect of final irrigation of the root canal with EDC on the bond strength (BS) longevity of an epoxy resin-based root-canal sealer. MATERIALS AND METHODS: Twenty maxillary canines were sectioned and standardized for root length at 17 mm. Roots were instrumented and distributed into 2 groups according to the final irrigation protocol: EDTA 17%+NaOCl 2.5% (C) and EDTA 17%+NaOCl 2.5%+EDC 0.5M (EDC). The canals were dried and filled with AH Plus (Dentsply Sirona). Three slices were obtained per third, and the first slice from each third was used for the immediate push-out test (i) followed by analysis of the failure pattern (n = 10); the second slice from each third was used for the push-out test after 6-month aging (A) followed by analysis of the failure pattern (n = 10); the third slice from each third was used to examine the adhesive interface under confocal laser scanning microscopy (CLSM) (n = 10). Data were analyzed with ANOVA, Fisher's exact and Kruskal-Wallis tests. RESULTS: Higher BSs were found for EDC-A (5.6 ± 1.9) than for EDC-I (3.3 ± 0.7), C-i (2.5 ± 1.0) and C-i (2.6 ± 1.0) (p = 0.0001), while C-A values were in some cases similar to C-i and in others similar to EDC-i. No statistically significant difference was observed between the thirds (p > 0.05), except for EDC-i, which showed lower BS for the cervical (2.79 ± 0.46) compared to the apical third (3.8 ± 0.5), while the middle third in some cases had values similar to those of the apical and in others to the cervical third (3.2 ± 0.7) (p = 0.032). More mixed adhesive failures were found in the cervical third, and more adhesive failures to the sealer occurred in the middle and apical thirds (p = 0.014). A significant difference was observed between treatments in terms of adaptation of the adhesive interface, with a higher percentage of good adaptation using EDC (66.7%) than using C (40%), and a lower percentage of poor adaptation with EDC (10%) compared to C (20%) (p < 0.05). CONCLUSION: Root canal irrigation with EDC increased the longevity of the adhesive interface of an epoxy resin-based root-canal sealer.


Asunto(s)
Recubrimiento Dental Adhesivo , Materiales de Obturación del Conducto Radicular , Resinas Epoxi/química , Materiales de Obturación del Conducto Radicular/química , Ácido Edético/química , Carbodiimidas , Cementos Dentales , Dentina , Ensayo de Materiales , Cavidad Pulpar , Irrigantes del Conducto Radicular
5.
J Adhes Dent ; 25(1): 39-50, 2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36744829

RESUMEN

PURPOSE: To evaluate the effect of carbodiimide (EDC) and chitosan (CHI) on the enzymatic activity (EA) and bond strength (BS) of different composite cements to root dentin. MATERIALS AND METHODS: Ninety (90) maxillary canines were sectioned, standardizing the length of the roots. The roots were endodontically treated, prepared, divided into 3 groups according to dentin treatment (distilled water [DW], CHI 0.2 wt%, or EDC 0.5M), and further subdivided into 3 subgroups according to composite cement (RelyX ARC [3M Oral Care], Panavia F 2.0 [Kuraray Noritaki], or RelyX U200 [3M Oral Care]). Of the slices obtained by sectioning, the most cervical of each third were subjected to a push-out test and the most apical were subjected to in-situ zymography. Half of the slices were analyzed immediately, and the other half after 6 months. The results were analyzed with ANOVA or the chi-squared test. RESULTS: RelyX ARC showed higher BS associated with CHI, while RelyX U200 showed higher BS associated with EDC (p = 0.044). For Panavia F 2.0, the treatment did not influence BS (p > 0.05). For the cervical and middle thirds, no differences were observed between the cements, while the apical third revealed higher BS for RelyX U200 (p < 0.001). The highest percentage of adhesive-to-dentin failures was observed for Panavia F 2.0. EDC showed the lowest percentage of adhesive-to-dentin failures. According to zymographic analysis, DW and CHI showed greater fluorescence for RelyX ARC, while EDC exhibited the lowest fluorescence of all cements (p > 0.05). CONCLUSION: The different mechanisms of action of solutions for pre-treatment of intraradicular dentin yielded different results depending on the adhesive used. EDC resulted in higher bond strength and higher enzyme inhibition for RelyX U200, while the treatment with chitosan resulted in higher bond strength and lower enzymatic activity for RelyX ARC. Although EDC and chitosan treatments did not influence the bond strength for Panavia F 2.0, both resulted in higher enzyme inhibition for this composite cement.


Asunto(s)
Quitosano , Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Quitosano/farmacología , Carbodiimidas/farmacología , Cementos de Resina/química , Cementos Dentales/química , Cementos de Ionómero Vítreo/química , Dentina , Ensayo de Materiales
6.
Dent Mater J ; 42(4): 532-541, 2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37225458

RESUMEN

To evaluate the push-out bond strength of the adjustable fiberglass post system to dentin. Twenty maxillary canine roots were endodontically treated and divided into two groups (n=10): conventional fiberglass posts (CFPs) and with single adjustable post (SAP) system. Two slices of each third were subjected to the push-out and failure pattern test and the most apical slice was subjected to analysis of the adhesive interface by scanning electron microscopy (SEM). Data were analyzed by the three-way analysis of variance, Tukey, and Friedman tests, and linear regression (α=0.05). The results showed higher push-out bond strength in the initial time interval for SAP (10.3±5.3, p<0.01). After 6 months, there was reduction in push-out bond strength for both (p<0.001). A higher percentage of adhesive and cohesive failures to dentin. After 6 months areas of maladaptation were noted (p=0.000). The SAP is completed to the promissory root canal in relation to alternative CFP.


Asunto(s)
Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Recubrimiento Dental Adhesivo/métodos , Cavidad Pulpar , Vidrio , Dentina , Ensayo de Materiales , Cementos de Resina/química
7.
J Adhes Dent ; 13(1): 55-9, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20157679

RESUMEN

PURPOSE: To evaluate the bond strength of glass fiber posts to intraradicular dentin when cemented with self-etching and self-adhesive resin cements. MATERIALS AND METHODS: Forty-eight single-rooted human teeth were decoronated, endodontically treated, post-space prepared and divided into 8 groups (n = 6). The glass fiber posts used were: Exacto (EA) (Angelus) and everStick (ES) (StichTeck), which were cemented with two self-adhesive resin cements: BisCem (BIS) (Bisco) and Rely-X Unicem (UNI) (3M/ESPE), and two self-etching resin cements: Esthetic Cementing System NAC100 (NAC) (Kuraray) and Panavia-F (PAN) (Kuraray). Specimens were thermocycled between 5°C and 55 °C for 1000 cycles and stored in water at 37°C for 1 month. Four 1-mm-thick (in cross section) rods were obtained from the cervical region of the roots. Specimens were then subjected to microtensile testing in a special machine (BISCO; Schaumburg, IL, USA) or a crosshead speed of 0.5 mm/min. Microtensile bond strength (µTBS) data were analyzed with two-way ANOVA and Tukey's tests. RESULTS: Means (and SD) of µTBS (MPa) were: EA/PAN: 10.3 (4.1), EA/NAC: 14 (5.1) EA/BIS: 16.4 (4.8), EA/UNI: 19.8 (5.1), ES/PAN: 25.9 (6.1), ES/NAC: 29.1 (7), ES/BIS: 28.9 (6), ES/UNI: 30.5 (6.6). ANOVA indicated significant differences among the groups (p < 0.001). Mean µTBS values obtained with ES post were significantly higher than those obtained with EA (p < 0.001). For EA, Tukey's test indicated that higher µTBS means were obtained with the self-adhesive resin cements (BIS and UNI), which were statistically significantly different (p < 0.05) from values obtained with the self-etching resin cements (PAN and NAC). Different cements had no significant effects on the bond strength values of ES post (p > 0.05). µTBS values obtained with ES post were significantly higher than those obtained with EA post irrespective of the resin cement used. CONCLUSION: everStick posts resulted in the highest mean µTBS values with all cements. Self-adhesive cements performed well in terms of bond strength.


Asunto(s)
Grabado Ácido Dental/métodos , Recubrimiento Dental Adhesivo , Técnica de Perno Muñón , Cementos de Resina , Análisis de Varianza , Resinas Compuestas , Análisis del Estrés Dental , Dentina , Vidrio , Humanos , Ensayo de Materiales , Estadísticas no Paramétricas , Resistencia a la Tracción
8.
J Prosthodont ; 19(7): 523-30, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20723014

RESUMEN

PURPOSE: Resistance of machined crowns to microleakage when cemented with new self-adhesive cements has not been fully investigated. This study evaluated microleakage of machined crowns milled from porcelain and composite blocks and bonded to teeth with self-adhesive and conventional resin cement. MATERIALS AND METHODS: Thirty-two freshly extracted premolars of similar shape and size were sterilized and mounted in resin blocks. Teeth received standard crown preparations with 1-mm circumferential shoulder finish line, flat occlusal surface reduced by 2 mm, and ideal angle of convergence. Prepared teeth were divided into two equal groups and assigned to either porcelain (Vita Mark II, Vident) or composite (Paradigm MZ100, 3M ESPE) blocks for crown fabrication. Optical impressions were captured for each tooth with the intraoral camera of a CEREC 3D machine. Crowns were designed and milled from both materials. Each group was then subdivided into two subgroups (n = 8) according to cement used (self-adhesive resin cement, RelyX Unicem, 3M ESPE or resin cement with self-etching adhesive, Panavia F 2.0, Kuraray). Following seating, a 5-kg weight was applied on the occlusal surface of the crown for 5 minutes. Specimens were then stored in water at 37°C for 24 hours. Specimens were thermocycled for 3000 cycles between 5°C and 55°C, then coated with nail varnish and immersed in a 2.0% basic red fuchsine dye solution for 24 hours. Teeth were then rinsed and sectioned mesiodistally and assessed under magnification for microleakage. A five-point scale was used to score degree of microleakage. Data were statistically analyzed with 2-way ANOVA and Kruskal-Wallis nonparametric test. RESULTS: Crown material had no significant effect on microleakage (p= 0.67); however, cement type had a significant effect (p < 0.0001), with Panavia F 2.0 resulting in lower microleakage scores than RelyX Unicem. CONCLUSIONS: Compared to the self-adhesive cement, the resin cement with separate primer/bonding agent resulted in significantly lower microleakage scores, irrespective of crown material.


Asunto(s)
Resinas Compuestas , Coronas , Filtración Dental/prevención & control , Porcelana Dental , Cementos de Resina , Adhesividad , Análisis de Varianza , Cementación , Diseño Asistido por Computadora , Grabado Dental/métodos , Diseño de Prótesis Dental , Humanos , Estadísticas no Paramétricas
9.
J Appl Oral Sci ; 27: e20180631, 2019 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-31411263

RESUMEN

OBJECTIVE: Extensive restorations in posterior teeth always bring doubts to the clinicians regarding the best protocol, mainly when structures of reinforcement were lost. OBJECTIVE: This study aimed to evaluate the effect of beveling on the fracture resistance and pattern of class II (MOD) restored teeth. METHODOLOGY: Ninety human premolars were randomly assigned into 9 groups: CTR (control/sound); NC (cavity preparation, non-restored); RU (restored, unbeveled); RTB (restored, entire angle beveling); RPB (restored, partial/occlusal beveling); EC (endodontic access/EA, non-restored); EU (EA, unbeveled); ETB (EA, entire angle beveling); EPB (EA, partial/occlusal beveling). Teeth were restored with Esthet X resin composite and stored in distilled water for 24 h before the inclusion in PVC cylinders. The axial loading tests were performed with 500 kgF at 0.5 mm/min crosshead speed until fracture of the specimens. Fracture resistance and pattern were accessed and data were analyzed using one-way ANOVA and Tukey's HSD test (α=0.05). RESULTS: Mean (±SD) failure loads ranged from 136.56 (11.62) to 174.04 (43.5) kgF in the groups tested without endodontic access. For endodontically accessed teeth, fracture resistance ranged from 95.54 (13.05) to 126.51 (19.88) kgF. Beveling of the cavosurface angle promoted the highest fracture resistance values (p<0.05) and prevented catastrophic fractures. CONCLUSIONS: Cavosurface angle beveling is capable of improving fracture resistance and pattern for both endodonticaly accessed and non-accessed teeth.


Asunto(s)
Diente Premolar , Preparación de la Cavidad Dental/métodos , Restauración Dental Permanente/métodos , Análisis de Varianza , Resinas Compuestas/uso terapéutico , Humanos , Distribución Aleatoria , Valores de Referencia , Reproducibilidad de los Resultados , Factores de Riesgo , Fracturas de los Dientes , Diente no Vital , Resultado del Tratamiento
10.
Braz Oral Res ; 33: e026, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30970090

RESUMEN

The aim of this study is to evaluate the machinability of four CAD/CAM materials (n = 13) assessed by brittleness index, Vickers hardness, and fracture toughness and interaction among such mechanical properties. The materials selected in this in vitro study are Feldspathic ceramic [FC], Lithium-disilicate glass ceramic [LD], leucite-reinforced glass ceramic [LR], and nanofilled resin material [RN]. Slices were made from the blocks following original dimensions 14 × 12 × 3 mm (L × W × H), using a precision slow-speed saw device and then surfaces were regularized through a polishing device. Brittleness index and fracture toughness were calculated by the use of specific equations for each one of the properties. The Vickers hardness was calculated automated software in the microhardness device. One-way Anova and Pearson's correlation were applied to data evaluation. LD obtained the highest values for brittleness index and was not significantly different from FC. LR presented statistically significant difference compared with RN, which had the lowest mean. Vickers hardness showed LD with the highest average, and no statistical difference was found between FC and LR. RN presented the lowest average. Fracture toughness showed FC and LR not statistically different from each other, likewise LD and RN. The brittleness index, considered also as the machinability of a material, showed within this study as positively dependent on Vickers hardness, which leads to conclusion that hardness of ceramics is related to its milling capacity. In addition, fracture toughness of pre-sintered ceramics is compared to polymer-based materials.


Asunto(s)
Silicatos de Aluminio/química , Cerámica/química , Diseño Asistido por Computadora , Porcelana Dental/química , Polímeros/química , Cementos de Resina/química , Análisis de Varianza , Pruebas de Dureza , Ensayo de Materiales , Valores de Referencia , Reproducibilidad de los Resultados , Estadísticas no Paramétricas , Propiedades de Superficie
11.
Quintessence Int ; 50(5): 350-356, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30957110

RESUMEN

OBJECTIVE: The objective was to evaluate the effects of the configuration of endodontic cavities with parallel or divergent walls, versus traditional endodontic cavities, on stress distribution, fracture resistance, and fracture mode of maxillary premolars by using both fracture-strength and finite element tests. METHOD AND MATERIALS: Thirty-two maxillary first premolars were divided into four groups (n = 8), according to the type of endodontic cavities: without endodontic cavities (control); conservative; conservative with diverging walls; and traditional. After performing root canal treatment and restoration, fracture resistance was evaluated by oblique compressive load. The stress distribution was evaluated by nonlinear finite element analysis by means of micro-computed tomography, operated at 50 kV and 800 mA. The fracture resistance data were analyzed by statistical software. RESULTS: Higher stress concentration was observed on the coronal portion of the palatal cusp and the palatal root dentin. Stress concentration on the palatal root dentin was similar for all groups. The stress level on the palatal cusp and at the proximal crests was slightly increased in the traditional endodontic cavities group compared with conservative endodontic cavities. Stress distribution in restored teeth was similar to that of intact teeth. No significant differences were observed in the fracture resistance among different endodontic cavities' design (P = .32). All groups had values similar to those of the control group (P > .05). CONCLUSIONS: Regardless of the cavity design, conservative endodontic cavities that preserve marginal ridge integrity did not affect the resistance to fracture, failure mode, or stress distribution in maxillary premolars restored with composite resin. Endodontically treated teeth displayed biomechanical behavior similar to sound teeth.


Asunto(s)
Fracturas de los Dientes , Diente no Vital , Diente Premolar , Resinas Compuestas , Preparación de la Cavidad Dental , Restauración Dental Permanente , Análisis del Estrés Dental , Humanos , Microtomografía por Rayos X
12.
Arch Oral Biol ; 86: 40-45, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29153956

RESUMEN

OBJECTIVES: To evaluate the effect of the bleaching with 35% hydrogen peroxide either activated or not by a 970nm diode laser on the chemical stability and dentin surface morphology of intracoronary dentin. METHODS: Twenty-seven slabs of intracoronary dentin specimens (3×3mm) were distributed into three groups (n=9), according to surface treatment: HP - 35% hydrogen peroxide (1×4'), DL - 970nm diode laser (1×30"/0,8W/10Hz), HP+DL - 35% HP activated with 970nm diode laser (1×30"/0,8W/10Hz leaving the gel in contact to the surface for 4' after activation). Three Raman spectra from each fragment were obtained to calculate the mean intensity of peaks of inorganic component (a.u.), organic collagen content (a.u.), and the ratio of inorganic/organic content, before and after treatment. Analyses of the samples by confocal laser microscopy were performed to evaluate the surface roughness, percentage of tubules, perimeter and area percentage of tubules, before and after treatment. Data were analyzed by Kruskal-Wallis, Dunn's, and Wilcoxon test (P<0.05). RESULTS: Data analysis showed that HP+DL did not change the inorganic content peaks 8.31 [29.78] or the inorganic/organic ratio 3.37 [14.67] (P>0.05). Similarly, DL did not affect the chemical stability of the dentin surface (P>0.05). However, HP significantly increased inorganic content peaks 10.87 [22.62], as well as the inorganic/organic ratio 6.25 [27.78] (P<0.05). Regarding the morphological alterations, all surface treatments increase tubules exposure; HP treatment significantly increases perimeter and area percentage; and HP+DL increases surface roughness. CONCLUSIONS: Bleaching HP combined with DL offers an improvement in terms of intracoronal dentin surface protection, yielding better maintenance of dentin chemical stability and morphology.


Asunto(s)
Dentina/efectos de los fármacos , Dentina/efectos de la radiación , Peróxido de Hidrógeno/farmacología , Láseres de Semiconductores , Blanqueadores Dentales/farmacología , Blanqueamiento de Dientes/métodos , Diente Canino , Humanos , Técnicas In Vitro , Espectrometría Raman , Propiedades de Superficie
13.
Microsc Res Tech ; 81(9): 973-979, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30295342

RESUMEN

The aim of this study was to evaluate the chemical and morphological effects of different lasers as a final surface treatment for endodontic therapy through energy dispersive X-ray spectroscopy (EDS) and scanning electron microscopy (SEM) respectively. Twenty-five maxillary canines were selected and instrumented with K3 system. Roots were randomly distributed into five groups (n = 5) according to the surface treatment: GI (distilled water), GII (NaOCl + EDTA), GIII (NaOCl + EDTA + 980 nm diode laser), GIV (NaOCl + EDTA+ 1,064 nm Nd:YAG laser), and GV (NaOCl + EDTA+ 2,780 nm Er, Cr:YSGG laser). Lasers were applied for 20 s and samples were bisected, exposing the treated surface and then subjected to elements quantification by EDS and morphological evaluation by scanning electron microscope (SEM). EDS data were submitted to ANOVA-two way, and SEM scores were submitted to two-way Kruskal-Wallis and Dunn's tests. The EDS analysis showed no difference for the chemical elements and Ca/P ratio between groups (p > .05). Statistical analysis showed more intense results for GV and less intense results for GI (p < .05). The GIII showed an amorphous organic matrix surface, while GV provided greater removal of intertubular dentin forming craters, and GIV promoted dentin fusion. The EDS method used in this study was not able to verify any chemical changes in root canal dentin; Nd:YAG, Er, Cr:YSGG, and 980 nm diode laser were capable of modifying the dentin morphology, correlating characteristics features for each one, which are essential clinical knowledge to establish the correct indication for each case. RESEARCH HIGHLIGHTS: EDS was not able to verify any chemical changes in root canal dentin after 980 nm diode, Nd:YAG and Er;Cr:YSGG laser treatments Nd:YAG, Er, Cr:YSGG, and 980 nm diode laser modified dentin morphology, correlating characteristics features for each one.


Asunto(s)
Diente Canino/efectos de la radiación , Dentina/efectos de la radiación , Terapia por Luz de Baja Intensidad , Raíz del Diente/efectos de la radiación , Diente no Vital , Diente Canino/anatomía & histología , Diente Canino/química , Dentina/anatomía & histología , Dentina/química , Humanos , Microscopía Electrónica de Rastreo , Espectrometría por Rayos X , Propiedades de Superficie/efectos de la radiación , Raíz del Diente/anatomía & histología , Raíz del Diente/química
14.
Quintessence Int ; 49(10): 781-786, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30264059

RESUMEN

OBJECTIVE: This study evaluated the wear of computer-aided design/computer-assisted manufacture (CAD/CAM) burs and the morphologic changes after a number of millings. METHOD AND MATERIALS: Diamond burs (cylinder and step-bur) were divided into four milling groups: zero millings (G0); 15 millings (G1); 25 millings (G2); and 35 millings (G3). Seventy-five premolar crowns were milled using the Cerec Compact Milling unit and VitaBlock Mark II. Surface roughness, three-dimensional profile, and SEM were used for wear and surface damage evaluation. RESULTS: Two-way ANOVA and Tukey test (α = .05) showed that G3 produced statistically different values compared to G0 and G2, but not G1. The cylinder burs showed higher roughness values than step-burs for all groups. SEM showed similar diamond particle damage for cylinder burs and step-burs, and signs of surface damage, cracks, and particle losses for G3. CONCLUSION: Both cylinder burs and step-burs were able to sustain a larger number of milling procedures than indicated by the manufacturer.


Asunto(s)
Diseño Asistido por Computadora , Instrumentos Dentales , Diamante/química , Análisis de Falla de Equipo , Diseño de Equipo , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie
15.
J Clin Exp Dent ; 9(4): e569-e573, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28469825

RESUMEN

BACKGROUND: Enamel is the hardest and the stiffest tissue in the human body. The enamel undergoes multidirectional stresses, withstands multimillion chewing cycles, all while protecting the internal dentin and pulp from damage due to mechanical overload and exposure to the harsh chemical environment of the mouth. Raman spectroscopy allows to study enamel mineral content in a non-destructive and site-specific way. While Raman spectroscopy has been applied in other studies to assess tooth mineralization, there are no studies that examine the relationship between micro-hardness and mineral content of the untreated enamel. An understanding of this relationship is extremely important in a clinical context. The effect of various agents on enamel hardness was investigated, though the relationship between healthy enamel mineral content and micro-hardness remains obscure. MATERIAL AND METHODS: Twenty human incisor teeth were obtained in compliance with the NIH guidelines and imaged site-specifically with a Raman microscope and evaluated with a Brinell hardness measurement device. The front portion of each tooth was divided into apical, medium and cervical regions and subsequently imaged with a Raman microscope in these three locations. RESULTS AND CONCLUSIONS: The results demonstrated that enamel mineral content varies significantly between individuals and is correlated with the hardness of the enamel. Non-invasive, sample preparation free Raman spectroscopy was successfully employed to measure the mineral content of healthy enamel and it correlated the mineralization score to the hardness measurements of the selected cervical location. The overall level of enamel mineral content may serve as a robust predictor of patients' susceptibility to developing caries, and overall enamels wear resistance, thus allowing for the prevention of caries via clinically available methods of remineralization, fluoride treatment and frequent cleaning. Key words:Enamel, raman spectroscopy, micro-hardness, extracted teeth.

16.
J Clin Exp Dent ; 9(2): e238-e241, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28210442

RESUMEN

BACKGROUND: Measurement of tooth enamel mineralization using a clinically viable method is essential since variation of mineralization may be used to monitor caries risk or in assessing the effectiveness of remineralization therapy. Fiber optic Raman systems are becoming more affordable and popular in context of biomedical applications. However, the applicability of fiber optic Raman systems for measurement of mineral content within enamel tissue has not been elucidated significantly in the prior literature. MATERIAL AND METHODS: Human teeth with varying degrees of enamel mineralization were selected. In addition alligator, boar and buffalo teeth which have increasing amount of mineral content, respectively, were also included as another set of samples. Reference Raman measurements of mineralization were performed using a high-fidelity confocal Raman microscope. RESULTS: Analysis of human teeth by research grade Raman system indicated a 2-fold difference in the Raman intensities of v1 symmetric-stretch bands of mineral-related phosphate bonds and 7-fold increase in mineral related Raman intensities of animal teeth. However, fiber optic system failed to resolve the differences in the mineralization of human teeth. CONCLUSIONS: These results indicate that the sampling volume of fiber optic systems extends to the underlying dentin and that confocal aperture modification is essential to limit the sampling volume to within the enamel. Further research efforts will focus on putting together portable Raman systems integrated with confocal fiber probe. Key words:Enamel, mineral content, raman spectroscopy.

17.
J Clin Exp Dent ; 9(7): e875-e878, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28828153

RESUMEN

BACKGROUND: Bio cellulose is a byproduct of sweet tea fermentation known as kombusha. During the biosynthesis by bacteria cellulose chains are polymerized by enzyme from activated glucose. The single chains are then extruded through the bacterial cell wall. Interestingly, a potential of the Kombucha's byproduct bio cellulose (BC) as biomaterial had come into focus only in the past few decades. The unique physical and mechanical properties such as high purity, an ultrafine and highly crystalline network structure, a superior mechanical strength, flexibility, pronounced permeability to gases and liquids, and an excellent compatibility with living tissue that reinforced by biodegradability, biocompatibility, large swelling ratios. MATERIAL AND METHODS: The bio-cellulose film specimens were provided by the R.P Dressel dental materials laboratory, Department of Comprehensive Care, School of Dental Medicine, Case Western Reserve University, Cleveland, US. The films were harvested, washed with water and dried at room temperature overnight. 1wt% of PEG-2000 and 10wt% of NaOH were added into ultrapure water to prepare PEG/NaOH solution. Then bio-cellulose film was added to the mixture and swell for 3 h at room temperature. All bio-cellulose film specimens were all used in the TA Instruments Q500 Thermogravmetric Analyzer to investigate weight percent lost and degradation. The TGA was under ambient air conditions at a heating rate of 10ºC/min. RESULTS AND CONCLUSIONS: PEG control exhibited one transition with the peak at 380ºC. Cellulose and cellulose/ PEG films showed 3 major transitions. Interestingly, the cellulose/PEG film showed slightly elevated temperatures when compared to the corresponding transitions for cellulose control. The thermal gravimetric analysis (TGA) degradation curves were analyzed. Cellulose control film exhibited two zero order transitions, that indicate the independence of the rate of degradation from the amount on the initial substance. The activation energies for three transitions for cellulose and cellulose/PEG showed increasingly higher values for the transitions at higher temperatures. Key words:TGA, Bio-cellulose, PEG.

18.
Compend Contin Educ Dent ; 38(3): e13-e17, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28257220

RESUMEN

OBJECTIVE: The purpose of this study was to evaluate if the marginal fit of computer-aided design and computer-aided manufacturing (CAD/CAM) restorations manufactured with CAD/CAM systems can be affected by different tooth preparation designs. METHODS: Twenty-six typodont (plastic) teeth were divided into two groups (n = 13) according to the occlusal curvature of the tooth preparation. These were the group 1 (control group) (flat occlusal design) and group 2 (curved occlusal design). Scanning of the preparations was performed, and crowns were milled using ceramic blocks. Blocks were cemented using epoxy glue on the pulpal floor only, and finger pressure was applied for 1 minute. On completion of the cementation step, poor fits between the restoration and abutment were measured by microphotography and the silicone replica technique using light-body silicon material on mesial, distal, buccal, and lingual surfaces. RESULTS: Two-way ANOVA analysis did not reveal a statistical difference between flat (83.61 ± 50.72) and curved (79.04 ± 30.97) preparation designs. Buccal, mesial, lingual, and distal sites on the curved design preparation showed less of a gap when compared with flat design. No difference was found on flat preparations among mesial, buccal, and distal sites (P < .05). The lingual aspect had no difference from the distal side but showed a statistically significant difference from mesial and buccal (P < .05). CONCLUSIONS: Difference in occlusal design did not significantly impact the marginal fit. Marginal fit was significantly affected by the location of the margin; lingual and distal locations exhibited greater margin gap values compared with buccal and mesial sites regardless of the preparation design.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Adaptación Marginal Dental , Diseño de Prótesis Dental , Preparación Protodóncica del Diente/métodos , Cementación/métodos , Cerámica , Humanos
20.
J Dent Educ ; 80(6): 662-9, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27251347

RESUMEN

A Comprehensive Care Experience Level (CCEL) system that is aligned with Commission on Dental Accreditation (CODA) standards, promotes comprehensive care and prevention, and addresses flaws observed in previous Relative Value Units (RVU)-based programs has been implemented at the School of Dental Medicine, Case Western Reserve University since 2011. The purpose of this article is to report on the design, implementation, and preliminary outcomes of this novel clinical evaluation system. With the development of the CCEL concept, it was decided not to award points for procedures performed on competency exams. The reason behind this decision was that exams are not learning opportunities and are evaluated with summative tools. To determine reasonable alternative requirements, production data from previous classes were gathered and translated into CCEL points. These RVU points had been granted selectively only for restorative procedures completed after the initial preparation stage of the treatment plan, and achievement of the required levels was checked at multiple points during the clinical curriculum. Results of the CCEL system showed that low performing students increased their productivity, overall production at graduation increased significantly, and fluoride utilization to prevent caries rose by an order of magnitude over the RVU system. The CCEL program also allowed early identification and remediation of students having difficulty in the clinic. This successful implementation suggests that the CCEL concept has the potential for widespread adoption by dental schools. This method also can be used as a behavior modification tool to achieve specific patient care or clinical educational goals as illustrated by the way caries prevention was promoted through the program.


Asunto(s)
Competencia Clínica , Atención Odontológica Integral/métodos , Educación en Odontología/métodos , Humanos , Evaluación de Programas y Proyectos de Salud
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA