Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(6): 1040-1047, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855180

RESUMEN

BACKGROUND: Genoss drug-eluting stent (DES) (Genoss Company Limited) is a new ultrathin sirolimus-eluting stent with an abluminal biodegradable polymer and a cobalt-chromium platform. AIMS: The aim of this study was to evaluate vascular healing and neointimal coverage after implantation of the Genoss DES using optical coherence tomography (OCT) 6 months postimplantation. METHODS: From August 22, 2019 to June 17, 2020, this multicenter, observational, investigator-initiated study enrolled 20 patients who underwent OCT examination 6 months after Genoss DES implantation and provided informed consent. An analyst, blinded to the patients' and procedural information analyzed OCT images at an independent core laboratory. RESULTS: Of the 20 patients, 19 with 27 stents in 21 lesions from 21 vessels were included in the analysis, while one patient withdrew consent and was unwilling to undergo follow-up OCT. OCT analysis was performed 204.4 ± 31.9 days after Genoss DES implantation. A total of 4285 stent struts from 661 cross-sections were analyzed. Strut tissue coverage was observed in 98.7 ± 4.3% of struts, with 0.1 ± 1.2% malapposed struts per lesion. The mean thickness of neointimal hyperplasia (NIH) on the covered struts was 0.12 ± 0.04 mm. CONCLUSIONS: Six months after stent implantation, most Genoss DES struts were covered with a thin layer of NIH that was evenly distributed along the stent length. This pilot study evaluated the outcomes of 6 months dual antiplatelet therapy in the context of ultrathin strut stents, providing insight into developing ethical standards and a scientific foundation for conducting an adequately designed clinical trial.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Sirolimus , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Proyectos Piloto , Resultado del Tratamiento , Diseño de Prótesis , Factores de Tiempo , Stents , Neointima/patología , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Tomografía de Coherencia Óptica , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología
2.
Circ J ; 83(7): 1489-1497, 2019 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-31155604

RESUMEN

BACKGROUND: There are limited data on the long-term outcome of platinum chromium-based everolimus-eluting stents (PtCr-EES) vs. cobalt chromium-based zotarolimus-eluting stents (CoCr-ZES).Methods and Results:A total of 3,755 patients undergoing percutaneous coronary intervention (PCI) were randomized 2:1 to PtCr-EES or CoCr-ZES, and 96.0% of patients completed the 3-year clinical follow-up. The primary outcome was target lesion failure (TLF), defined as a composite of cardiac death, target vessel-related myocardial infarction (MI), and clinically-driven target lesion revascularization (TLR). At 3 years, TLF occurred in 5.3% and in 5.4% of the PtCr-EES and CoCr-ZES groups, respectively (hazard ratio 0.978; 95% confidence interval 0.730-1.310, P=0.919). There were no significant differences in the individual components of TLF. Routine angiographic follow-up was performed in 38.9% of the total patients. In a landmark analysis of the subgroup that had follow-up angiography, the clinically-driven TLR rate of CoCr-ZES was significantly higher than PtCr-EES group during the angiography follow-up period (P=0.009). Overall definite and probable stent thrombosis rates were very low in both groups (0.5% vs. 0.6%, P=0.677). CONCLUSIONS: PtCr-EES and CoCr-ZES had similar and excellent long-term outcomes in both efficacy and safety after PCI in an all-comer population.


Asunto(s)
Angiografía Coronaria , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea , Sirolimus/análogos & derivados , Anciano , Cromo , Aleaciones de Cromo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Platino (Metal) , Estudios Prospectivos , Falla de Prótesis , Sirolimus/administración & dosificación
3.
Catheter Cardiovasc Interv ; 88(2): 193-200, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26423017

RESUMEN

OBJECTIVES: To assess the safety and efficacy of fractional flow reserve (FFR) guided paclitaxel-coated balloon (PCB) treatment for de novo coronary artery lesions. BACKGROUND: There is limited data on PCB treatment for de novo lesions especially of major epicardial coronary arteries. METHODS: Sixty-six patients with 67 de novo lesions who underwent successful plain old balloon angioplasty (POBA) were included. If POBA-FFR was favorable (≥ 0.85), PCB was applied and if POBA-FFR was <0.85, stent implantation was preferred over PCB. RESULTS: Forty-five lesions were treated with PCB (67.2%) and 22 lesions with stents (32.8%). Dual antiplatelet therapy duration was 6 weeks. Late luminal loss with PCB was significantly less than stent (0.05 ± 0.27 mm vs. 0.40 ± 0.54 mm, P = 0.022). The baseline FFR of target lesions was 0.69 ± 0.16 in PCB and 0.60 ± 0.11 in stent group (P = 0.015), however, the FFR at 9 months was not different between groups (0.85 ± 0.08 in PCB vs. 0.85 ± 0.05 in stent group, P = 0.973). At 1 year, one myocardial infarction and one target lesion revascularization related to in-stent restenosis were detected, both in the stent group. CONCLUSION: POBA-FFR-guided PCB treatment is safe and effective for de novo coronary lesions with good anatomical and physiological patency at mid-term follow-up. © 2015 Wiley Periodicals, Inc.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/efectos de los fármacos , Stents Liberadores de Fármacos , Reserva del Flujo Fraccional Miocárdico/efectos de los fármacos , Paclitaxel/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/etiología , Vasos Coronarios/fisiopatología , Quimioterapia Combinada , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Paclitaxel/efectos adversos , Inhibidores de Agregación Plaquetaria/administración & dosificación , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , República de Corea , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular/efectos de los fármacos
4.
JACC Cardiovasc Interv ; 16(3): 292-299, 2023 02 13.
Artículo en Inglés | MEDLINE | ID: mdl-36609038

RESUMEN

BACKGROUND: Data on drug-coated balloon (DCB) treatment in the context of multivessel coronary artery disease (CAD) are limited. OBJECTIVES: The purpose of this study was to investigate the impact of DCB-based treatment on percutaneous coronary intervention for multivessel CAD. METHODS: A total of 254 patients with multivessel disease successfully treated with DCBs or in combination with drug-eluting stents (DES) were retrospectively enrolled (DCB-based group) and compared with 254 propensity-matched patients treated with second-generation DES from the PTRG-DES (Platelet Function and Genotype-Related Long-Term Prognosis in Drug-Eluting Stent-Treated Patients With Coronary Artery Disease) registry (n = 13,160) (DES-only group). Major adverse cardiovascular events (MACE) comprised cardiac death, myocardial infarction, stroke, stent thrombosis, target vessel revascularization, and major bleeding at 2 years. RESULTS: Baseline clinical characteristics were comparable between the groups. In the DCB-based group, 34.3% of patients were treated with DCBs only and 65.7% were treated with the DES hybrid approach. The number of stents and total stent length were significantly reduced by 65.4% and 63.7%, respectively, in the DCB-based group compared with the DES-only group. Moreover, the DCB-based group had a lower rate of MACE than the DES-only group (3.9% and 11.0%; P = 0.002) at 2-year follow-up. The DES-only group had a higher risk for cardiac death and major bleeding. CONCLUSIONS: The DCB-based treatment approach showed a significantly reduced stent burden for multivessel percutaneous coronary intervention and led to a lower rate of MACE than the DES-only treatment. This study shows that DCB-based treatment approach safely reduces stent burden in multivessel CAD, and improved long-term outcomes may be expected by reducing stent-related events. (Impact of Drug-Coated Balloon Treatment in De Novo Coronary Lesion; NCT04619277).


Asunto(s)
Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Estudios Retrospectivos , Resultado del Tratamiento , Intervención Coronaria Percutánea/efectos adversos , Reestenosis Coronaria/etiología , Materiales Biocompatibles Revestidos , Angiografía Coronaria
5.
Cardiol J ; 28(1): 136-149, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-31565793

RESUMEN

Coronary artery disease (CAD) is currently the leading cause of death globally, and the prevalence of this disease is growing more rapidly in the Asia-Pacific region than in Western countries. Although the use of metal coronary stents has rapidly increased thanks to the advancement of safety and efficacy of newer generation drug eluting stent (DES), patients are still negatively affected by some the inherent limitations of this type of treatment, such as stent thrombosis or restenosis, including neoatherosclerosis, and the obligatory use of dual antiplatelet therapy (DAPT) with unknown optimal duration. Drug-coated balloon (DCB) treatment is based on a leave-nothing-behind concept and therefore it is not limited by stent thrombosis and long-term DAPT; it directly delivers an anti-proliferative drug which is coated on a balloon after improving coronary blood flow. At present, DCB treatment is recommended as the first-line treatment option in metal stent-related restenosis linked to DES and bare metal stent. For de novo coronary lesions, the application of DCB treatment is extended further, for conditions such as small vessel disease, bifurcation lesions, and chronic total occlusion lesions, and others. Recently, several reports have suggested that fractional flow reserve guided DCB application was safe for larger coronary artery lesions and showed good long-term outcomes. Therefore, the aim of these recommendations of the consensus group was to provide adequate guidelines for patients with CAD based on objective evidence, and to extend the application of DCB to a wider variety of coronary diseases and guide their most effective and correct use in actual clinical practice.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Reserva del Flujo Fraccional Miocárdico , Preparaciones Farmacéuticas , Angioplastia Coronaria con Balón/instrumentación , Asia , Materiales Biocompatibles Revestidos , Consenso , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/fisiopatología , Humanos , Resultado del Tratamiento
6.
Angiology ; 72(10): 986-993, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33982603

RESUMEN

We evaluated the angiographic parameter and clinical outcomes of drug-coated balloon (DCB) to assess the optimal angiographic criteria in de novo small vessel disease (SVD). Patients (n = 424, mean age: 64.4 ± 11.2 years, men: 69.8%) at 20 sites in Korea were prospectively enrolled. The primary end point was late luminal loss (LLL) at 9-month follow-up angiography. Secondary end points included restenosis rates, target lesion failure (TLF), and DCB-related thrombosis during the 12-month follow-up period. We included 403 patients for analysis excluding 21 patients who required bailout stenting. Baseline mean reference vessel .diameter was 2.52 ± 0.39 mm and mean minimal luminal diameter (MLD) was 0.71 ± 0.40 mm. The mean MLD was 1.54 ± 0.37 mm after DCB. Late luminal loss was -0.01 ± 0.43 mm and restenosis was noted in 26 patients (12.2%). Minimal luminal diameter >1.6 mm and %diameter stenosis (DS) <45% after DCB was associated maintenance of MLD without LLL at 9-months. Multivariate analysis demonstrated that %DS at baseline and post-MLD was associated with the restenosis. During 12-month follow-up, TLF was 2.6% including 1 cardiac death, 1 myocardial infarction, and 10 ischemia-driven target lesion revascularizations. Drug-coated balloon showed a low restenosis and lower LLL despite high in-segment DS. Post-MLD and % DS may be helpful to get optimal results in de novo SVD after DCB.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Paclitaxel/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , República de Corea , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Int J Cardiovasc Imaging ; 36(2): 179-185, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31598811

RESUMEN

Paclitaxel-coated balloon (PCB) treatment guided by fractional flow reserve (FFR) is safe and effective for de novo coronary lesions. It is unknown whether the instantaneous wave-free ratio (iFR), an alternative measure that does not require the administration of adenosine, will offer benefits similar to those of FFR in de novo lesion treatment with PCB. Baseline, post-balloon and 9-month angiographical parameters were obtained from 116 lesions of 104 patients. The cutoff value of iFR after balloon angioplasty used to define functionally nonsignificant residual stenotic lesions was 0.86 and they were subdivided into PCB or Stent group according to the treated device. The primary endpoint was late lumen loss at 9 months and the secondary endpoint was target vessel failure (TVF) at 3 years. Fifty-eight lesions were treated with PCB only and 58 lesions were treated with metal stent implantation. There were no differences in iFR between PCB and Stent groups at baseline (0.76 ± 0.19 vs. 0.73 ± 0.23, p = 0.630) and after procedure (0.93 ± 0.04 vs. 0.94 ± 0.05, p = 0.574). At 9 months, late lumen loss was significantly lower in PCB group compared with Stent group (0.04 ± 0.32 mm vs. 0.59 ± 0.77 mm, p = 0.001). At 3-year follow-up, TVF were not different between the treatment groups (5.2% vs. 8.6%, p = 0.453). PCB treatment guided by iFR measured right after balloon angioplasty is safe and effective for de novo coronary lesions with good angiographic results at 9 months and similar clinical outcomes at 3 years compared to stent group.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Cateterismo Cardíaco , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Reserva del Flujo Fraccional Miocárdico , Paclitaxel/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico , Estenosis Coronaria/fisiopatología , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Valor Predictivo de las Pruebas , Sistema de Registros , Índice de Severidad de la Enfermedad , Stents , Factores de Tiempo , Resultado del Tratamiento
8.
Int J Cardiovasc Imaging ; 35(11): 1945-1954, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31214851

RESUMEN

Lesion characteristics determined by angiography after balloon angioplasty such as residual dimeter stenosis (DS) or dissection type has been used to determine the treatment method of drug-coated balloon (DCB) or metal stent for de novo coronary lesions. The aim of this study is to identify angiographic and functional mismatch using residual DS, dissection type and fractional flow reserve (FFR). Baseline and post-balloon parameters were obtained from 151 patients with 167 lesions. Angiographically significant parameters after balloon angioplasty are residual DS > 30% or dissection type C or more. Post-balloon FFR cutoff value of 0.75 was used to define functionally significant lesions. The weak correlation was found between residual DS and post-balloon FFR (r =  - 0.317, p < 0.001). There were 68.7% of mismatch population (residual DS > 30% and post-balloon FFR ≥ 0.75) and 7.1% of reverse mismatch population (residual DS ≤ 30% and post-balloon FFR < 0.75). All reverse mismatch lesions were found in left anterior descending artery. There was no correlation between dissection severity and post-balloon FFR (p = 0.654). In high post-balloon FFR group, long-term clinical outcomes showed no difference between DCB and stent groups with (p = 0.788) or without (p = 0.426) the adjustment of lesion characteristics. There were high frequencies of mismatch between angiographic lesion characteristics and FFR values after balloon angioplasty. Post-balloon FFR measurements may be safe and effective compared to angiography-guided treatment if DCB only treatment is considered.


Asunto(s)
Angioplastia Coronaria con Balón , Cateterismo Cardíaco , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Sistema de Registros , Stents , Resultado del Tratamiento
9.
Coron Artery Dis ; 30(6): 425-431, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31009399

RESUMEN

BACKGROUND: In patients with high bleeding risk, percutaneous coronary intervention is still debated. This study compared 9-month angiographic and physiologic results in patients with high bleeding risk and de novo coronary lesions treated with either paclitaxel-coated balloon (PCB) or bare-metal stent (BMS). PATIENTS AND METHODS: A total of 40 patients (40 lesions) with high bleeding risk who underwent successful balloon angioplasty with fractional flow reserve (FFR) after balloon angioplasty more than 0.80 were randomized 1: 1 to treatment with PCB versus BMS. Dual antiplatelet therapy was limited to 1 month after the procedure. RESULTS: Baseline clinical and lesional characteristics were well balanced between the two groups. There was no significant difference in the postprocedural FFR (0.87 ± 0.06 in PCB vs. 0.89 ± 0.06 in BMS, P = 0.254). At 9 months, late luminal loss was significantly lower in the PCB group (0.2 ± 0.3 vs. 1.2 ± 0.8 mm, P < 0.001). Restenosis only occurred in the BMS group (0 vs. 25.0%, P = 0.049). CONCLUSION: In patients with high bleeding risk, FFR-guided PCB treatment showed superior efficacy in terms of angiographic and physiologic patency compared with BMS at mid-term follow-up with only 1 month of dual antiplatelet therapy (Clinicaltrials.gov identifier, NCT02456402).


Asunto(s)
Angioplastia de Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Hemorragia/etiología , Metales , Paclitaxel/administración & dosificación , Stents , Anciano , Angioplastia de Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Terapia Antiplaquetaria Doble/efectos adversos , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , República de Corea , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
10.
Coron Artery Dis ; 29(5): 403-408, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29620557

RESUMEN

OBJECTIVES: Periprocedural myocardial infarction (PMI) is reported to be associated with adverse long-term clinical outcomes. This study compared the rates of PMI following treatment of de novo coronary lesions using either a paclitaxel-coated balloon (PCB) or a newer-generation drug-eluting stent (DES). PATIENTS AND METHODS: We compared the incidence of PMI in propensity-matched patients with stable angina pectoris and single-vessel de novo coronary lesions who underwent treatment with a PCB or newer-generation DES. Propensity score matching was performed to adjust for differences in baseline clinical and angiographic characteristics. RESULTS: After propensity matching, the study cohort included 108 patients (PCB: n=54 and DES: n=54). The peak mean values of creatine kinase-myocardial band (13.3±26.3 vs. 2.2±2.8 ng/ml, P=0.003) and high-sensitive troponin T (0.62±1.38 vs. 0.09±0.19 ng/ml, P=0.007) were significantly higher in the DES group compared with the PCB group. The incidence of PMI was significantly higher in the DES group [DES: 11 (20.4%) vs. PCB: one (1.9%); P=0.002]. Total occlusion of the side-branch occurred in two patients treated with DES, but no patients treated with PCB. Treatment with a newer-generation DES was found to be an independent predictor of PMI on multivariable analyses. CONCLUSION: In patients with stable angina using a PCB, compared with deployment of a newer-generation DES, is associated with a significant reduction in the risk of PMI.


Asunto(s)
Angina Estable/terapia , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Stents Liberadores de Fármacos , Infarto del Miocardio/prevención & control , Paclitaxel/administración & dosificación , Anciano , Angina Estable/diagnóstico por imagen , Angina Estable/epidemiología , Biomarcadores/sangre , Fármacos Cardiovasculares/efectos adversos , Angiografía Coronaria , Forma MB de la Creatina-Quinasa/sangre , Bases de Datos Factuales , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Infarto del Miocardio/sangre , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/epidemiología , Paclitaxel/efectos adversos , Puntaje de Propensión , Diseño de Prótesis , República de Corea/epidemiología , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Troponina T/sangre
11.
JACC Cardiovasc Interv ; 11(10): 969-978, 2018 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-29798774

RESUMEN

OBJECTIVES: The aim of this study was to investigate the impact of optimizing procedure-related factors during drug-eluting balloon (DEB) angioplasty on clinical outcomes of drug-eluting stent in-stent restenosis (ISR). BACKGROUND: Although DEB angioplasty is recommended as a reasonable option for ISR, recurrent target lesion failure (TLF) still occurs in many patients after DEB angioplasty. METHODS: Consecutive patients with drug-eluting stent ISR treated with DEB (SeQuent Please) were collected from 4 centers in Korea. The primary outcome was 2-year TLF. Procedure-related modifiable independent predictors for TLF and their best cutoff values were determined. RESULTS: In a total of 256 patients (309 lesions), TLF occurred in 52 patients (20.3%). Modifiable independent predictors of TLF among procedure-related factors were residual diameter stenosis after lesion preparation (residual percentage diameter stenosis [%DS]), DEB-to-stent ratio (BSR), and DEB inflation time (Tinflation), whose best cutoff values were 20%, 0.91, and 60 s, respectively. TLF rates were significantly higher in groups with residual %DS ≥20% (34.7% vs. 12.5%; adjusted hazard ratio: 2.15; 95% confidence interval: 1.86 to 2.48; p < 0.001), BSR ≤0.91 (46.4% vs. 21.9%; adjusted hazard ratio: 2.02; 95% confidence interval: 1.75 to 2.34; p < 0.001), and Tinflation ≤60 s (26.2% vs. 14.0%; adjusted hazard ratio: 1.82; 95% confidence interval: 1.36 to 2.45; p < 0.001). When classifying ISR lesions by combination of procedure-related factors, TLF occurred in 8.3% in the fully optimized procedure group (residual %DS <20%, BSR >0.91, and Tinflation >60 s) and 66.7% in the nonoptimized group (residual %DS ≥20%, BSR ≤0.91, and Tinflation ≤60 s) (p < 0.001). CONCLUSIONS: Residual %DS after lesion preparation, BSR, and Tinflation were the only modifiable procedure-related factors in DEB angioplasty. Fully optimized DEB angioplasty with optimal lesion preparation, prolonged inflation, and sufficient dilation may play an important role in reducing TLF after DEB angioplasty.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Sistema de Registros , República de Corea , Retratamiento , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
15.
Trials ; 16: 409, 2015 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-26374625

RESUMEN

BACKGROUND: Antiplatelet treatment is an important component in optimizing the clinical outcomes after percutaneous coronary intervention (PCI) especially in patients with acute coronary syndrome (ACS). Prasugrel, which is a new P2Y12 inhibitor, has been confirmed as efficacious in a large trial in Western countries, and a similar trial is also to be launched in Asian countries. Although a 60-mg loading dose of prasugrel followed by 10 mg per day should be acceptable, there have been no data regarding the optimal dose in Asian patients. Furthermore, serum levels of prasugrel and the rates of platelet inhibition are known to be higher in Asians than Caucasians with the same dose of the drug. Polymer, a key component of drug-eluting stents (DES), has been suggested as the cause of inflammation leading to late complications, and has driven many companies to develop biodegradable-polymer DES. Currently, there are limited data regarding the head-to-head comparison between BP-BES and the biostable polymer CoCr-EES or the newest platinum-chromium everolimus-eluting stent (PtCr-EES). Furthermore, the polymer issue may be more important in ACS where there is ruptured thrombotic plaque where polymer-induced inflammation may affect the local milieu of the stented artery. Therefore, the present study dedicated only to ACS patients, will offer important information on the optimal prasugrel dose in the Asian population by comparing a 10-mg versus a 5-mg maintenance dose beyond 1 month after PCI, as well as giving important insight into the polymer issue by comparing BP-BES versus biostable-polymer PtCr-EES. METHOD/DESIGN: Harmonizing Optimal Strategy for Treatment of coronary artery diseases--comparison of REDUCtion of prasugrEl dose or POLYmer TECHnology in ACS patients (HOST-REDUCE-POLYTECH-ACS) trial is a multicenter, randomized and open-label clinical study with a 2 × 2 factorial design, according to the type of stent (PtCr-EES versus BP-BES) and prasugrel maintenance dose (5 mg versus 10 mg), to demonstrate non-inferiority of PtCr-EES relative to BP-BES or the reduced prasugrel dose relative to conventional dose in an Asian all-comers PCI population presenting with ACS. Approximately 3400 patients will undergo prospective, random assignment separately to either stent or prasugrel arm (1:1 ratio, respectively). When the patients have contraindications to prasugrel, they are categorized into an antiplatelet observation group after stent-randomization. The primary endpoint is the patient-oriented composite outcome, which is a composite of all-cause mortality, any myocardial infarction (MI), any repeat revascularization in the stent arm at 12 months after index PCI. In the prasugrel arm, primary endpoint is any major adverse cardiovascular event, which is a composite of all-cause mortality, any MI, any stent thrombosis (Academic Research Consortium (ARC)-defined), any repeat revascularization, stroke, or bleeding (BARC class ≥ 2). DISCUSSION: The HOST-REDUCE-POLYTECH-ACS RCT is the first study exploring the optimal maintenance dose of prasugrel beyond 1 month after PCI for ACS in Asian all-comers. In addition, this is the largest study dedicated only to ACS patients to evaluate the polymer issue in the situation of ACS by directly comparing biostable-polymer PtCr-EES versus BP-BES. TRIAL REGISTRATION: ClinicalTrials.gov (ID: NCT02193971, 13 July 2014).


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Inhibidores de Agregación Plaquetaria/administración & dosificación , Polímeros , Clorhidrato de Prasugrel/administración & dosificación , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/etnología , Síndrome Coronario Agudo/mortalidad , Pueblo Asiatico , Causas de Muerte , Protocolos Clínicos , Stents Liberadores de Fármacos/efectos adversos , Everolimus/administración & dosificación , Hemorragia/inducido químicamente , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Inhibidores de Agregación Plaquetaria/efectos adversos , Polímeros/efectos adversos , Clorhidrato de Prasugrel/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , República de Corea/epidemiología , Proyectos de Investigación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
16.
J Am Coll Cardiol ; 63(25 Pt A): 2805-16, 2014 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-24814486

RESUMEN

OBJECTIVES: This study sought to test whether the newly developed platinum chromium (PtCr)-based everolimus-eluting stent (EES) is noninferior to the cobalt chromium (CoCr)-based zotarolimus-eluting stent (ZES) in all-comers receiving percutaneous coronary intervention (PCI). BACKGROUND: PtCr provides improved radial strength, conformability, and visibility compared with the CoCr alloy, but PtCr-based stents have not been tested in a wide range of patients receiving PCI. Also, recent case series have raised the issue of longitudinal stent deformation (LSD) with newer drug-eluting stents. METHODS: We randomly assigned 3,755 all-comers receiving PCI to PtCr-EES or CoCr-ZES. The primary outcome was target lesion failure (TLF) at 1-year post-PCI, defined as the composite of cardiac death, nonfatal target vessel-related myocardial infarction, and ischemia-driven target lesion revascularization. Post-hoc angiographic analysis was performed to qualitatively and quantitatively analyze LSD. RESULTS: At 1 year, TLF occurred in 2.9% and 2.9% of the population in the PtCr-EES and CoCr-ZES groups, respectively (superiority p = 0.98, noninferiority p = 0.0247). There were no significant differences in the individual components of TLF as well as the patient-oriented clinical outcome. Of 5,010 stents analyzed, LSD occurred in 0.2% and 0% in the PtCr-EES and CoCr-ZES groups, respectively (p = 0.104). There was no significant difference in post-deployment stent length ratio between the 2 stents (p = 0.352). CONCLUSIONS: At 1 year, PtCr-EES was noninferior to CoCr-ZES in all-comers receiving PCI. Although LSD was observed only in PtCr-EES, both the stent length ratio and the frequency of LSD were not significantly different between the 2 stent types, and PtCr-EES was not associated with adverse clinical outcomes. (Harmonizing Optimal Strategy for Treatment of Coronary Artery Stenosis-SAfety & EffectiveneSS of Drug-ElUting Stents & Anti-platelet REgimen [HOST-ASSURE]; NCT01267734).


Asunto(s)
Estenosis Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos , Inmunosupresores/uso terapéutico , Intervención Coronaria Percutánea/métodos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Sirolimus/análogos & derivados , Antineoplásicos , Aleaciones de Cromo , Compuestos de Cromo , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Compuestos de Platino , Estudios Prospectivos , Diseño de Prótesis , República de Corea , Método Simple Ciego , Sirolimus/uso terapéutico , Resultado del Tratamiento
17.
Trials ; 13: 29, 2012 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-22463698

RESUMEN

BACKGROUND: Second-generation drug-eluting stents (DES) have raised the bar of clinical performance. These stents are mostly made from cobalt chromium alloy. A newer generation DES has been developed from platinum chromium alloy, but clinical data regarding the efficacy and safety of the platinum chromium-based everolimus-eluting stent (PtCr-EES) is limited, with no comparison data against the cobalt chromium-based zotarolimus-eluting stent (CoCr-ZES). In addition, an antiplatelet regimen is an integral component of medical therapy after percutaneous coronary intervention (PCI). A 1-week duration of doubling the dose of clopidogrel (double-dose antiplatelet therapy (DDAT)) was shown to improve outcome at 1 month compared with conventional dose in acute coronary syndrome (ACS) patients undergoing PCI. However in Asia, including Korea, the addition of cilostazol (triplet antiplatelet therapy (TAT)) is used more commonly than doubling the dose of clopidogrel in high-risk patients. METHODS: In the 'Harmonizing Optimal Strategy for Treatment of coronary artery stenosis - sAfety & effectiveneSS of drug-elUting stents & antiplatelet REgimen' (HOST-ASSURE) trial, approximately 3,750 patients are being prospectively and randomly assigned in a 2 × 2 factorial design according to the type of stent (PtCr-EES vs CoCr-ZES) and antiplatelet regimen (TAT vs DDAT). The first primary endpoint is target lesion failure at 1 year for the stent comparison, and the second primary endpoint is net clinical outcome at 1 month for comparison of antiplatelet therapy regimen. DISCUSSION: The HOST-ASSURE trial is the largest study yet performed to directly compare the efficacy and safety of the PtCr-EES versus CoCr-ZES in an 'all-comers' population. In addition, this study will also compare the clinical outcome of TAT versus DDAT for 1-month post PCI. TRIAL REGISTRATION: ClincalTrials.gov number NCT01267734.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Inhibidores de Agregación Plaquetaria/uso terapéutico , Proyectos de Investigación , Angioplastia Coronaria con Balón/efectos adversos , Cromo , Aleaciones de Cromo , Estenosis Coronaria/tratamiento farmacológico , Quimioterapia Combinada , Everolimus , Humanos , Inhibidores de Agregación Plaquetaria/efectos adversos , Platino (Metal) , Estudios Prospectivos , Diseño de Prótesis , República de Corea , Método Simple Ciego , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Resultado del Tratamiento
18.
EuroIntervention ; 6(9): 1110-6, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21518685

RESUMEN

AIMS: To compare the intravascular ultrasound virtual histology (IVUS-VH) appearance of the polymeric struts of the first (Revision 1.0) and the second (Revision 1.1) generation bioresorbable vascular scaffold (BVS). METHODS AND RESULTS: IVUS-VH misrepresents polymeric struts as dense calcium (DC) and necrotic core (NC) so that their presence and disappearance could be used as potential artifactual surrogate of bioresorption. DC and NC were assessed in both revisions of the BVS by analysing IVUS-VH from all patients in the ABSORB cohort A (Revision 1.0) and cohort B (Revision 1.1) study who had an IVUS-VH post-treatment and at 6-month follow-up. Post-treatment and 6-month follow-up IVUS-VH results, available in 60 patients (BVS 1.0 n=28; BVS 1.1 n=32), indicated an insignificant rise in DC+NC area compared to baseline with Revision 1.1 (0.10 ± 0.46 mm2, p=0.2), whilst a significant reduction was seen with Revision 1.0 (-0.57 ± 1.3 mm2, p=0.02). A significant correlation has been found between the change in the DC+NC area and the change in external elastic membrane area (y=0.68x-0.1; r=0.58, p=0.03). CONCLUSIONS: Based on 6-months IVUS-VH analysis, the BVS 1.1 appears to have a different backscattering signal compared to the BVS 1.0, which may reflect differences in the speed of chemical and structural alteration.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Andamios del Tejido , Ultrasonografía Intervencional , Anciano , Australia , Calcinosis/diagnóstico por imagen , Fármacos Cardiovasculares/uso terapéutico , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Europa (Continente) , Everolimus , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Necrosis , Nueva Zelanda , Poliésteres , Diseño de Prótesis , Sirolimus/administración & dosificación , Sirolimus/análogos & derivados , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA