Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Comb Chem High Throughput Screen ; 12(7): 664-76, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19531020

RESUMEN

The development of stents has been a major advancement over balloon angioplasty, improving vessel revascularization in obstructive coronary artery disease. The development of drug-eluting stents (DES) was the next breakthrough, designed to prevent the development of neointimal hyperplasia (restenosis) following percutaneous coronary interventions (PCI). Several DES are currently in various stages of clinical development; these DES use different stent platforms, different antiproliferative drugs and different polymeric coatings that carry the drugs and control their delivery kinetics. Following DES implantation, when the entire drug is released, the polymeric coating is still retained on the stent and can influence subsequent tissue response and vascular healing. Therefore, the biocompatibility of the polymeric coatings is an important component of DES safety and needs to be thoroughly evaluated. Here we describe the development of a high-throughput screening platform for the evaluation of polymer biocompatibility, assaying whether a polymeric coating triggers inflammation in vascular cells. The data generated by these assays provides a structure-activity relationship (SAR) that can guide polymer chemists in polymer design. We have also applied this methodology to evaluate the components of a novel polymer system (BioLinx polymer system) designed in-house. In addition, we assayed other polymeric coatings similar to those currently used on various DES. The results of this evaluation reveal a remarkable correlation between polymer hydrophobicity and its ability to provoke inflammatory response.


Asunto(s)
Materiales Biocompatibles Revestidos , Trombosis Coronaria , Diseño de Fármacos , Stents Liberadores de Fármacos , Inflamación , Adhesión Celular , Células Cultivadas , Trombosis Coronaria/genética , Vasos Coronarios/citología , Humanos , Inflamación/genética , Estructura Molecular , Relación Estructura-Actividad , Propiedades de Superficie
2.
J Biomed Mater Res A ; 90(1): 133-41, 2009 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18491390

RESUMEN

Polymer coatings are essential for local delivery of drug from the stent platform. In designing a DES, it is critical to balance the hydrophilic and hydrophobic components of the polymer system to obtain optimal biocompatibility, while maintaining controlled drug elution. This study investigates the impact of polymer composition of the BioLinx polymer blend on in vitro biocompatibility, as measured by monocytic adhesion. Comparable evaluation was performed with polymers similar to those utilized in various DES that are currently being marketed. Relative hydrophilicities of polymer surfaces were determined through contact angle measurements and surface analyses. Polymer biocompatibility was evaluated in a novel in vitro assay system in which activated monocyte cells were exposed to polymer coated on 96-well plates. Enhanced monocyte adhesion was observed with polymers of a more hydrophobic nature, whereas those which were more hydrophilic did not induce activated monocyte adhesion. Our data supports the hypothesis that polymer composition is a feature that dictates in vitro biocompatibility as measured by monocyte driven inflammation. Monocyte adhesion has been shown to induce local inflammation as well as promote vascular cell proliferation factors contributing to in stent restenosis (Rogers et al., Arterioscler Thromb Vasc Biol 1996;16:1312-1318). Observed results suggest hydrophobic but not hydrophilic polymer surfaces support adhesion of activated monocytes to the polymer scaffold. The proprietary DES polymer blend BioLinx has a hydrophilic surface architecture and does not induce an inflammatory response as measured by these in vitro assays.


Asunto(s)
Materiales Biocompatibles Revestidos/química , Stents Liberadores de Fármacos , Polímeros/química , Adhesión Celular , Células Cultivadas , Sistemas de Liberación de Medicamentos , Interacciones Hidrofóbicas e Hidrofílicas , Ensayo de Materiales , Estructura Molecular , Monocitos/citología , Monocitos/metabolismo , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA