Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Medicina (Kaunas) ; 59(2)2023 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-36837479

RESUMEN

Background and Objectives: The aim of this in vitro study was to evaluate the combined effect of a 2% chlorhexidine aqueous solution and a universal adhesive system applied in self-etch and etch-and-rinse strategies on the composite resin-dentin interface. Materials and Methods: Class V cavities were prepared on the facial and lingual surfaces of forty caries-free molars extracted for orthodontic reasons. The samples were randomly divided into two groups corresponding to the used etching protocol: I-etch-and-rinse; II-self-etch. In each tooth, one cavity was assigned for the control subgroups -IA (n = 20) and IIA (n = 20)-adhesive only, and the opposite cavity was pretreated with a 2% chlorhexidine solution-Gluco CHeX Cerkamed-subgroups IB (n = 20) and IIB (n = 20). Both sets of groups were restored using a universal adhesive system (Single Bond Universal Adhesive, 3M-ESPE) and a bulk-fill composite resin (Filtek One Bulk Fill Restorative, 3M-ESPE). The roots and the pulp tissue were then removed, and a needle connected to a perfusor with 100 mL saline solution was used for pulp pressure simulation with a hydrostatic pressure of 20 cm H2O. Cariogenic attack was simulated using a demineralizing solution for 3 days at a constant temperature of 25 °C. The teeth were then sectioned in a facial-lingual direction and the microleakages at the occlusal and cervical margins were registered and scored using an optical Carl-Zeiss AXIO Imager A1m microscope (Carl-Zeiss). The composite resin-dentin interface was analyzed using a SEM Vega Tescan LMH II. Statistical analysis was performed using the Kruskal-Wallis test with a significance level of p < 0.05. Results: Microleakage evaluation showed no significant differences among the study groups (p > 0.05). In subgroup IA, significant differences were recorded between occlusal and cervical margins (p < 0.05). Conclusions: Application of chlorhexidine on tooth substrate before using a universal bonding system in total etch or self-etch mode has no influence on the adhesive interface in the condition of cariogenic attack. The thickness of the adhesive resin layer seems to be less uniform when using chlorhexidine, but the morphological differences at the adhesive interface have no influence on the sealing capacity of the universal bonding system, regardless of the etching strategy.


Asunto(s)
Clorhexidina , Cementos de Resina , Humanos , Recubrimientos Dentinarios/química , Resinas Compuestas/química , Dentina
2.
Medicina (Kaunas) ; 58(9)2022 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-36143826

RESUMEN

Background and Objectives: The aim of this in vitro study was to evaluate the effect of simulated gastric acid associated with toothbrushing on the surface condition of three resin-modified glass-ionomer cements (RMGIC). Materials and Methods: One hundred and sixty samples of each material were obtained and included in three study groups according to the tested material: Group I (Ionolux, VOCO GmbH, Cuxhaven, Germany); Group II (Vitremer, 3 M-ESPE, St. Paul, MN, USA); and Group III (Fuji II LC, GC Corporation, Tokyo, Japan). The samples were submersed in hydrochloric acid 0.01 M (pH 3.8) for 3 h and exposed to a toothbrushing procedure at a frequency of 10,000 cycles with medium and hard bristles immediately or 30 min after the acid attack. Profilometric measurements were performed by using a non-contact profilometer (Dektak XT, Bruker, Billerica, MA, USA) in order to assess the surface roughness. ANOVA and Bonferroni post hoc tests were used for the statistical analysis at a significance level of p < 0.05. Results: Exposure of RMGICs to the erosive effect of hydrochloric acid in association with toothbrushing 30 min after the chemical attack increased the surface roughness of all three RMGICs. Exposure of the three tested materials exclusively to the action of hydrochloric acid did not affect the surface roughness. Conclusions: One year of hydrochloric acid challenge associated with one year of toothbrushing with medium-hardness bristles performed 30 min after the acid attack increase the surface roughness of two of the three types of RMGIC tested (Ionolux and Fuji II LC).


Asunto(s)
Ácido Clorhídrico , Cepillado Dental , Ácido Gástrico , Cementos de Ionómero Vítreo , Humanos , Ensayo de Materiales , Propiedades de Superficie
3.
Medicina (Kaunas) ; 58(9)2022 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-36143960

RESUMEN

Background and Objectives: The aim of this in vitro study was to evaluate the effect of gastric acid associated with the effect of toothbrushing on the surface roughness of different types of composite resin used for direct restorations. Materials and Methods: The materials used in this study were two microhybrid (Filtek Z250, Herculite XRV) and two nanohybrid (Filtek Z550, Herculite XRV Ultra) composite resins. Two hundred and forty cylindrical samples with a height of 2 mm and a diameter of 6 mm were divided into four groups (groups A, B, C and D) corresponding to each tested material (n = 60). Each group was divided in two subgroups: subgroup I-the samples were submersed in hydrochloric acid and immediately submitted to toothbrushing; subgroup II-the samples were submitted only to toothbrushing. The simulation of the acid attack was performed by immersing the samples in a 0.01 M hydrochloric acid solution for 90 min. This procedure was followed immediately by toothbrushing simulation with 10,000 cycles. The acid attack and toothbrushing simulation were performed for two times. The surface roughness evaluation was performed with a Proscan 2100 profilometer. Repeated Measures ANOVA and Bonferroni post-hoc tests were used to perform the statistical analysis. Results: Simulation of one year of toothbrushing associated or not to hydrochloric acid exposure increases the surface roughness of microhybrid and nanohybrid composite resins. Six months of toothbrushing associated to six months of hydrochloric acid exposure increase the surface roughness of nanohybrid composite resins. Conclusions: Microhybrid composite resins surface becomes rougher after toothbrush and acid submersion when comparing to nanohybrid composite resins.


Asunto(s)
Ácido Clorhídrico , Cepillado Dental , Resinas Compuestas , Ácido Gástrico , Humanos , Propiedades de Superficie
4.
Dent J (Basel) ; 12(4)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38668004

RESUMEN

INTRODUCTION: The aim of this in vitro study was to compare the quality of marginal sealing at the cervical margins of indirect and direct composite resin restorations in mesio-occluso-distal (MOD) cavities. MATERIAL AND METHOD: MOD preparations were performed on 30 extracted teeth. The mesial cervical margin of each tooth was relocated using a flow composite resin (Enamel Plus HRi Flow, Micerium, Avegno, GE, Italy), then the samples were divided into three groups. In group A, the cavities were directly restored using a nanohybrid composite resin (Miris 2 Coltène Whaledent, Altstaetten, Switzerland) and a universal adhesive (ScotchBond Universal, 3M ESPE, St. Paul, MN, USA) by the etch-and-rinse strategy, for group B, the restoration procedure was similar but the self-etch strategy was used, and the samples in group C were filled using the inlay technique. Each sample was stored for 48 h in a 2% methylene blue solution, then it was cut in a mesio-distal direction using a Struers Secotom 50 device (Cleveland, OH, USA). The marginal sealing and adhesive interface were assessed for each sample at the cervical margin by optical microscopy (OM) and scanning electron microscopy (SEM). One-way ANOVA and Bonferroni post-hoc tests were used with a significance level of 0.05. RESULTS: Significant differences were recorded within groups A and C, between mesial and distal margins (p = 0.02 in group A and p = 0.043 in group C). CONCLUSIONS: The marginal sealing is more effective in MOD inlay restoration compared to direct restorations. Relocation of the cervical margin with flow composite resin and the use of different adhesive strategies do not improve the marginal sealing.

5.
Dent J (Basel) ; 12(6)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38920849

RESUMEN

The aim of this study was to evaluate the level of knowledge of resident dentists and new graduates regarding the etiology, clinical diagnosis, and treatment of the main medical emergency conditions. The study included a sample of 152 new graduates and residents in the first, second, and third year of training in Prosthodontics and General Dentistry from the Faculty of Dental Medicine in Iasi, Romania. Their level of knowledge and the attitudes were assessed using a questionnaire with 24 questions, divided into four sections. The differences among groups were identified using the chi-square test (p < 0.05). A high level of knowledge was found among the three groups of subjects for the questions regarding the recognition of clinical signs in hypoglycemic crisis (88-100%), in anaphylactic shock (83.3-94.5%), and the treatment of angina pectoris (76.2-84.2%). In contrast, a low level of knowledge was found for the questions regarding pulse evaluation in the case of an emergency (26.3-35.7%), the parameters of normal breathing (28.9-43%), and the treatment of hypoglycemic crisis (27.8-44.8%). The study indicated that the dentists had a moderate understanding of dental office medical emergencies and preferred practical training over theoretical courses.

6.
Biomedicines ; 11(9)2023 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-37760904

RESUMEN

There are two main methods used for dentin hypersensitivity (DH) treatment: dentinal tubule occlusion and blockage of nerve activity. Dentifrices are the most common vehicles for active ingredients used for DH treatment. The aim of this study was to evaluate the efficacy of three toothpastes on dentinal tubule occlusion, mineral acquisition, and dentin hardness. Forty human dentin disks were submerged in 40% citric acid for 30 s and then exposed to tooth brushing for 2 min twice a day for 14 days using three toothpastes: Dontodent Sensitive (group 1), Dr. Wolff's Biorepair (group 2), and Sensodyne Repair and Protect (group 3). In the control group (group 4), the samples were brushed with water. All of the samples were evaluated using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX), and Vickers dentin hardness determination. On SEM images, the degree of dentinal tubule occlusion was assessed using a five-grade scale. The mean score values in groups 1-4 were 3.60 ± 0.69, 2.20 ± 0.91, 2.30 ± 1.16, and 5.00 ± 0.00, significantly higher in study groups when compared to the control group (Kruskal Wallis test p < 0.05). EDX evaluation showed significantly higher calcium and phosphorus concentrations in groups 1 and 3 when compared to control group d. The mean values of Vickers dentin hardness numbers in groups 1-4 were 243.03 ± 10.014, 327.38 ± 56.65, 260.29 ± 37.69, and 225.83 ± 29.93, respectively. No statistically significant results were obtained when comparing the hardness mean values in groups (Kruskal-Wallis statistical test, p = 0.372 > 0.05). All three toothpastes tested demonstrated significant occlusion of dentinal tubules. Dontodent Sensitive and Sensodyne Repair and Protect toothpastes enhanced the calcium and phosphorus content of the dentin surface. None of the toothpastes increased dentin hardness as a result of mineral acquisition.

7.
Diagnostics (Basel) ; 13(3)2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36766635

RESUMEN

BACKGROUND: The aim of the study was to assess the protective effect of applying potassium iodide (KI) over silver diamine fluoride (SDF) on demineralized root dentin in the case of a sustained acidogenic attack. METHODS: Forty caries-free third molars were used in the study. A diamond disc was used to separate the roots and the tooth crowns from the roots. Each root fragment was randomly distributed in one of the four study groups: C-samples were not demineralized; DD-demineralized samples; RS1-demineralized samples covered with SDF+KI (RS-Riva Star product, SDI limited, Bayswater, Australia); RS2-demineralized samples covered with SDF+KI and submersed to another acidic challenge for 3 days. SEM and EDX were used for the morphological and elemental analysis. Vickers hardness assessment was performed using a tribometer CETR UMT-2 (Bruker Corporation, Berlin, Germany). One-way ANOVA and post hoc Bonferroni tests were used for the statistical analysis with a significance level of p < 0.05. RESULTS: Morphological and elemental changes were observed on the surface of the study samples. Significant differences were observed between the recorded hardness values of groups C and DD (p = 0.005), C and RS2 (p = 0.002), DD and RS1 (p = 0.011); RS1 and RS2 (p = 0.004). CONCLUSIONS: The application of SDF and KI (Riva Star product) on root dentin caries resulted in the formation of a heterogeneous outer layer that sealed the dentin and increased the microhardness of the treated surface. In the conditions of the present study, this layer did not provide enough protection for root dentin exposed to continuous attacks.

8.
Biomedicines ; 11(9)2023 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-37760795

RESUMEN

Graphene, as a promising material, holds the potential to significantly enhance the field of dental practices. Incorporating graphene into dental materials imparts enhanced strength and durability, while graphene-based nanocomposites offer the prospect of innovative solutions such as antimicrobial dental implants or scaffolds. Ongoing research into graphene-based dental adhesives and composites also suggests their capacity to improve the quality and reliability of dental restorations. This narrative review aims to provide an up-to-date overview of the application of graphene derivatives in the dental domain, with a particular focus on their application in prosthodontics and periodontics. It is important to acknowledge that further research and development are imperative to fully explore the potential of graphene and ensure its safe use in dental practices.

9.
Healthcare (Basel) ; 11(9)2023 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-37174891

RESUMEN

Dentists play an essential role in the treatment of dental and periodontal traumatic injuries by providing early and correct treatment. The purpose of the present study was to assess the level of knowledge of dental residents regarding dental trauma. The cross-sectional study was conducted at the Faculty of Dental Medicine within the "Grigore T. Popa" University of Medicine and Pharmacy in Iasi, Romania on a sample of 366 residents in General Dentistry, Pediatric Dentistry and Periodontology. To assess their knowledge, a questionnaire was created containing 18 questions about the clinical signs and therapy of dental trauma, with a focus on tooth avulsion. A very low level of knowledge (<25%) was found only for the type of splinting required to maintain an avulsed tooth on the arch. The highest number of correct answers was provided by the residents in Periodontology. Physiological serum as storage medium was recognized by a percentage of 75.9-80% of the subjects, and 60-77% of them recognized pulp necrosis as complication of dental avulsion. The study underlines the need to introduce in the curriculum of all categories of residents additional information, not only in the already existent theoretical form, but also as possible scenarios of various clinical situations.

10.
Biomedicines ; 10(5)2022 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-35625745

RESUMEN

This in vitro study aimed to assess the erosive effect of hydrochloric acid in association with toothbrushing procedure on the surface condition of three bulk-fill composite resins used for direct restoration. A total of 480 samples (160 from each composite resin): X-tra Fil (VOCO, Germany)­group A, Filtek Bulk-fill Posterior (3M-ESPE, St. Paul, MN, USA)­group B, G-aenial Posterior (GC Japan)­group C were prepared, submitted to chemical attack for 60 min with hydrochloric acid 30% and, subsequently, submitted to the abrasive effect of toothbrushing using 10,000 cycles with medium and hard bristles, at three different times (immediately and after 30 min after acid attack or without any chemical attack). The surface roughness of the samples was measured using a noncontact profilometer (Dektak XT, Bruker, Billerica, MA, USA). The values were analyzed using ANOVA and post hoc Bonferroni tests, with a p < 0.05. Chemical attack for 60 min associated with one year of toothbrushing with toothbrushes having medium or hard bristles increase the surface roughness of tested bulk-fill composite resins. No differences were recorded between toothbrushing with medium or firm bristles immediately or 30 min after acidic challenge for each of the three bulk-fill composite resins. Exposure to hydrochloric acid determines no effect on surface roughness of bulk-fill composite resins.

11.
Materials (Basel) ; 15(3)2022 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-35160942

RESUMEN

The aim of this in vitro study was to evaluate the effect of hydrochloric acid associated with the abrasive effect of toothbrushing on the surface condition of three flowable composite resins used for direct restoration. Seventy samples of each composite resin: Grandio Flow (VOCO, Germany)-group A, Filtek Ultimate Flow (3M-ESPE, MN, USA)-group B, G-aenial Flo X (GC Europe)-group C were prepared, submersed in hydrochloric acid 30% for 60 min and then submitted to simulated toothbrushing procedure using 5000 cycles with toothbrushes with medium and hard bristles, immediately after the chemical attack, after 30 min or without any chemical attack. The sample's surface roughness was analyzed using a noncontact profilometer (Dektak XT, Bruker, USA). ANOVA and post hoc Bonferroni tests, with a p < 0.05, were used to analyze the values. Hydrochloric acid action for 60 min and six months of toothbrushing using toothbrushes having medium hardness or firm bristles affects the surface roughness of tested flowable composite resins. Toothbrushing with firm bristles immediately after acidic challenge determines increased surface roughness for two of the three flowable composite resins (Grandio Flow and Filtek Ultimate Flow). Toothbrushing with medium or firm bristles thirty minutes after the acidic aggression determine no effect on surface condition of flowable composite resins.

12.
Rom J Morphol Embryol ; 51(2): 299-302, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20495747

RESUMEN

UNLABELLED: Aim of study is to compare the effect of etching with ortho-phosphoric acid on sound dentine, affected dentine and sclerotic dentine through AFM analysis. MATERIAL AND METHODS: The group study included 30 extracted third molars, 20 with acute and chronic carious lesions and 10 intact teeth. Teeth were sectioned in long axe to prepare sections with carious lesions surrounded by sound dentine. The sound teeth were sectioned to a depth of dentine comparable with carious lesions depth. The sections were etched with 37% ortho-phosphoric acid. The surface roughness was determined initially and after etching using AFM analysis. The results were expressed as relative variation of squared roughness. RESULTS: The values of relative roughness indices were between 2.78 and 3 for sclerotic dentine, 3.18 and 3.26 for sound dentine, 3.32 and 3.38 for affected dentine. The highest values of roughness index were recorded for the affected dentine samples. Significant statistically values were recorded when comparing relative roughness indices for sclerotic dentine with relative roughness indices for affected dentine and sound dentine. CONCLUSIONS: clerotic dentine has significant higher resistance to the action of ortho-phosphoric acid than affected dentine and sound dentine. The lowest resistance to the action of etching agent was recorded for the affected dentine.


Asunto(s)
Esmalte Dental/ultraestructura , Microscopía de Fuerza Atómica/métodos , Diente/ultraestructura , Grabado Ácido Dental/métodos , Dentina/efectos de los fármacos , Dentina/patología , Humanos , Propiedades de Superficie
13.
Rev Med Chir Soc Med Nat Iasi ; 110(2): 438-42, 2006.
Artículo en Ro | MEDLINE | ID: mdl-17802958

RESUMEN

UNLABELLED: The aim of the study was to asses the influence of the time, method and type of light curing on the compressive strength of dental composites. Dental composite resin (T-Econom, Ivoclar Vivadent) was cured for 10, 30 or 40 sec. with either a commercial conventional halogen light curing unit (LCU)--Hilux, (Benliodlu Dental Inc), or a light emitting diode (LED), LCU-Bluedent LED Smart. The compressive strengths were determined after 72 h on samples 3 mm in diameter and 7 mm high using FPZ 100/1 device. RESULTS: The samples cured with LED LCU for 40 seconds in pulse mode showed the smallest values of compressive strength (245 MPa), while those cured with LED LCU for 40 seconds in ramp mode reached the highest values (295 MPa). Similar values for compressive strength were found for the samples polymerized with conventional halogen LCU and the samples cured with LED LCU in constant mode (283 MPa and 285 MPa, respectively). CONCLUSIONS: Compressive strength depends on the light type and method. Tested LED curing light seems to induce similar compressive strengths as the halogen-based light. Using this conventional light curing unit requires at least 40 seconds of exposure in order to achieve adequate compressive strength. The LED light curing unit should be used in the ramp mode for at least 40 sec, followed by 10 sec in fast mode in order to achieve the best results.


Asunto(s)
Resinas Compuestas/química , Equipo Dental , Materiales Dentales/química , Luz , Ensayo de Materiales , Polímeros/química , Resinas Compuestas/efectos de la radiación , Fuerza Compresiva , Halógenos , Humanos
14.
Rev Med Chir Soc Med Nat Iasi ; 108(4): 894-8, 2004.
Artículo en Ro | MEDLINE | ID: mdl-16004238

RESUMEN

The recent improvement of adhesive materials should decrease the risk related to saliva contamination. The aim of this study was to evaluate the effect of saliva contamination on the microleakage within class V cavities restored with three different types of materials: conventional glass ionomer cement, composite resin and compomer. 30 human extracted teeth were randomly divided in 3 equal groups. In each group, class V cavities were prepared on both facial and lingual surfaces (but joint for glass ionomer cement and bevelled incisal margin for composite resin and compomer). The lingual cavities were contaminated with saliva prior to restoration, while the facial cavities were not contaminated, serving as control. After water storage for 24 hours, teeth were immersed in 1% methylene blue solution for 24 hours. The axial sections were viewed under an optical microscope and the extent of dye penetration along cervical, axial and incisal margins was measured in millimetres. Statistic analysis showed that under salivary contamination, microleakage increased along the cervical margin of restoration for all three tested materials. Saliva contamination resulted in microleakage within the axial wall of the cavity only for the conventional glass ionomer cement. These data indicate that composite resin and compomer used together with new adhesives seem to be less sensitive to saliva contamination compared to conventional materials. However, under saliva contamination, cervical microleakage cannot be completely prevented and proper isolation should still be mandatory.


Asunto(s)
Adhesivos/uso terapéutico , Filtración Dental , Restauración Dental Permanente , Saliva , Algoritmos , Colorantes , Compómeros/análisis , Resinas Compuestas/análisis , Recubrimiento Dental Adhesivo , Preparación de la Cavidad Dental , Cementos Dentales , Cementos de Ionómero Vítreo/análisis , Humanos , Ensayo de Materiales , Microscopía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA