Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Catheter Cardiovasc Interv ; 95 Suppl 1: 587-597, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31943693

RESUMEN

OBJECTIVES: To report the clinical outcomes of the RESTORE drug-coated balloon (DCB; Cardionovum, Bonn, Germany) for treatment of de novo small vessel disease (SVD) beyond 1 year. BACKGROUND: Previous reports have demonstrated the noninferiority of the RESTORE DCB to the RESOLUTE Integrity drug-eluting stent (DES; Medtronic, Minneapolis, Minnesota) in terms of 9-month in-segment percent diameter stenosis. METHODS: In the prospective, multicenter, noninferiority RESTORE SVD China trial, 230 patients with visually-estimated reference vessel diameter (RVD) ≥2.25 and ≤2.75 mm were randomized to DCB or DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Furthermore, 32 patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel (VSV) registry. Clinical follow-up were performed at 2 years to evaluate target lesion failure (TLF) in both groups and the VSV cohort. RESULTS: Overall, 256 (97.7%) patients (115 and 109 in the DCB and DES groups, respectively, and 32 in the VSV cohort) completed 2 years of follow-up. There was no significant difference in TLF between the DCB and DES groups (5.2 vs. 3.7%, p = .75). Target lesion revascularization was acceptable at 1 month, 1 year, and 2 years, and did not differ significantly with DCB from that in the DES group (0.9 vs. 0%, p = 1.0, 4.4 vs. 2.6%, p = .72, 5.2 vs. 2.8%, p = .50, respectively). CONCLUSIONS: Compared to the second-generation DES, the RESTORE DCB did not increase the risk of clinical outcomes. Late catch-up phenomen requiring revascularization was not significant in this study.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Anciano , Angioplastia Coronaria con Balón/efectos adversos , China , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 93(S1): 832-838, 2019 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-30888736

RESUMEN

OBJECTIVES: This prospective, patient-level analysis assessed the safety and efficacy of NeoVas sirolimus-eluting bioresorbable scaffold (BRS) in patients with coronary lesions. Furthermore, to meet China Food and Drug Administration requirements, we conducted an objective performance criterion study by pooling all patients implanted with the NeoVas BRS in a previous randomized controlled trial (RCT) and registry trial. BACKGROUND: Drug-eluting stent-related permanent vessel caging by metallic struts may lead to several complications associated with percutaneous coronary intervention. BRSs reportedly result in more stent thromboses (ST) in comparison to everolimus-eluting stents. The NeoVas (Lepu Medical, Beijing, China) is a novel sirolimus-eluting poly-l-lactic acid (PLLA)-based BRS whose safety and efficacy remains to be fully elucidated. METHODS: Patient-level data derived from 1,103 patients with de novo native coronary lesions in the NeoVas RCT (n = 278) and NeoVas registry (n = 825) were prospectively collected, pooled, and analyzed. The primary outcome was 12-month target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven-target lesion revascularization. The patient-oriented composite endpoint (PoCE) of all-cause death, all MI, or any revascularization was also analyzed. RESULTS: The 12-month rate of TLF in 1,103 patients (follow-up rate, 99.8%) was 3.0%, significantly lower than the performance goal of 8.5% (P < 0.0001). Furthermore, 50 (5.4%) PoCEs and five definite/probable ST (0.5%) were recorded. CONCLUSIONS: This pooled, patient-level analysis indicates that the NeoVas BRS has promising 1-year efficacy and safety profiles.


Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Síndrome Coronario Agudo/diagnóstico por imagen , Síndrome Coronario Agudo/mortalidad , Adolescente , Adulto , Anciano , Fármacos Cardiovasculares/efectos adversos , China , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Sistema de Registros , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
3.
Macromol Rapid Commun ; 40(5): e1800252, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30027623

RESUMEN

Novel graphene-oxide-reinforced silicone composites (GOSC) are prepared by in situ polymerization of silanes and low concentrations (<0.15 wt%) of silylated GO (SGO). After modification, the distances of the SGO nanosheets are successfully increased from 0.72 to 0.87 nm. Compared with GO, the SGO shows better dispersibility in organic solvents as well as remarkably enhanced decomposition temperature (T d improved by 100 °C). After covalently grafting onto silicone resins via in situ polymerization, the obtained GOSC exhibits greatly enhanced thermal stability (T d up to 400 °C and T g improved by 3-5 °C), increased storage modulus, loss modulus, and complex viscosity. The morphology, microstructure, interfacial adhesion of the developed GOSC coatings were carefully investigated. The GOSC coatings on metal exhibit good transparency (up to 90%), hydrophobicity, and excellent anticorrosion capability. This work provides a new strategy for developing high performance graphene-based silicone composite materials.


Asunto(s)
Grafito/síntesis química , Polimerizacion , Siliconas/síntesis química , Rastreo Diferencial de Calorimetría , Corrosión , Grafito/química , Dispersión del Ángulo Pequeño , Siliconas/química , Termogravimetría , Difracción de Rayos X
4.
Coron Artery Dis ; 32(6): 526-533, 2021 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-33229940

RESUMEN

BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging in contemporary clinical applications. Drug-coated balloon (DCB) angioplasty offers an effective treatment for ISR. Shenqi is a novel iopromide-based paclitaxel-coated balloon and its clinical safety, effectiveness and angiographic efficacy in patients with ISR have not been investigated. METHODS: A total of 216 subjects with the first occurrence of ISR at 11 investigational sites in China were randomly allocated in a 1:1 fashion to treatment with DCB SeQuent Please or Shenqi. Clinical follow-up was planned at 1, 6, 9 and 12 months, and angiographic follow-up was planned at 9 months. The study was powered for the primary endpoint of 9-month in-segment late loss. RESULTS: At 9-month follow-up, the in-segment late loss was 0.29 ± 0.43 mm with Shenqi versus 0.30 ± 0.46 mm with SeQuent Please, and the one-sided 97.5% upper confidence limit of the difference was 0.14 mm, achieving noninferiority of Shenqi compared with SeQuent Please (P = 0.002). In total, 12 patients developed target lesion failure (TLF) in the Shenqi group compared with 16 patients in the SeQuent Please group (10.91% versus 15.09%; P = 0.42) within 1 year. TLF was mainly driven by target lesion revascularization (9.09%) followed by target vessel-related myocardial infarction (1.82%) and cardiovascular death (0.91%) in the Shenqi group. CONCLUSIONS: Shenqi DCB was noninferior to SeQuent Please DCB for the primary endpoint of 9-month in-segment late loss. Shenqi DCB may become an attractive alternative treatment for patients with coronary ISR, withholding the need for additional stent implantation.


Asunto(s)
Angioplastia Coronaria con Balón , Reestenosis Coronaria/tratamiento farmacológico , Stents Liberadores de Fármacos , Medicamentos Herbarios Chinos/uso terapéutico , Yohexol/análogos & derivados , Paclitaxel/uso terapéutico , China , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Femenino , Humanos , Yohexol/uso terapéutico , Masculino , Persona de Mediana Edad
5.
JACC Cardiovasc Interv ; 11(23): 2381-2392, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30522667

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the angiographic efficacy and clinical outcomes of the Restore paclitaxel-coated balloon in a randomized trial designed to enable its approval with an indication for small-vessel disease (SVD). BACKGROUND: Higher rates of restenosis and stent thrombosis limit the effectiveness of drug-eluting stent (DES) treatment of SVD. Whether a drug-coated balloon (DCB)-only strategy is effective in de novo SVD is not yet established. METHODS: In the noninferiority RESTORE SVD China trial, eligible patients with reference vessel diameter ≥2.25 and ≤2.75 mm were randomized to the Restore DCB or the RESOLUTE Integrity DES in a 1:1 ratio stratified by diabetes and number of lesions treated. Patients with RVD ≥2.00 and <2.25 mm were enrolled in a nested very small vessel registry. Angiographic and clinical follow-up were planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment percentage diameter stenosis. RESULTS: Between August 2016 and June 2017, a total of 230 subjects at 12 sites were randomized to the DCB group (n = 116) or DES group (n = 114); 32 patients were treated with the DCB in the very small vessel cohort. Nine-month in-segment percentage diameter stenosis was 29.6 ± 2.0% with the DCB versus 24.1 ± 2.0% with the DES; the 1-sided 97.5% upper confidence limit of the difference was 10.9%, achieving noninferiority of the DCB compared with the DES (p for noninferiority < 0.001). The DCB and DES had comparable 1-year rates of target lesion failure (4.4% vs. 2.6%, p = 0.72). CONCLUSIONS: In this multicenter randomized trial, the Restore DCB was noninferior to the RESOLUTE DES for 9-month in-segment percentage diameter stenosis. (Assess the Efficacy and Safety of RESTORE Paclitaxel Eluting Balloon Versus RESOLUTE Zotarolimus Eluting Stent for the Treatment of Small Coronary Vessel Disease; NCT02946307).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Estenosis Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , China , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Sirolimus/administración & dosificación , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
6.
JACC Cardiovasc Interv ; 11(3): 260-272, 2018 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-29413240

RESUMEN

OBJECTIVES: The authors sought to evaluate the safety and effectiveness of the NeoVas bioresorbable scaffold (BRS) compared with metallic drug-eluting stents. BACKGROUND: BRS have the potential to improve very late outcomes compared with metallic drug-eluting stents, but some BRS have been associated with increased rates of device thrombosis before complete bioresorption. NeoVas is a new poly-l-lactic acid BRS that elutes sirolimus from a poly-D, l-lactide coating. METHODS: Eligible patients with a single de novo native coronary artery lesion with a reference vessel diameter 2.5 to 3.75 mm and a lesion length ≤20 mm were randomized 1:1 to NeoVas BRS versus cobalt-chromium everolimus-eluting stents (CoCr-EES). Angiographic follow-up was performed in all patients at 1 year. The primary endpoint was angiographic in-segment late loss (LL), and the major secondary endpoint was the rate of angina. Baseline and follow-up optical coherence tomography and fractional flow reserve were performed in a pre-specified subgroup of patients. RESULTS: The authors randomized 560 patients at 32 centers to treatment with NeoVas (n = 278) versus CoCr-EES (n = 282). One-year in-segment LL with NeoVas and CoCr-EES were 0.14 ± 0.36 mm versus 0.11 ± 0.34 mm (difference 0.03 mm; upper 1-sided 97.5% confidence interval 0.09 mm; pnoninferiority < 0.0001; psuperiority = 0.36). Clinical outcomes at 1 year were similar in the 2 groups, as were the rates of recurrent angina (27.9% vs. 32.1%; p = 0.26). Optical coherence tomography at 1 year demonstrated a higher proportion of covered struts (98.7% vs. 96.2%; p < 0.001), less strut malapposition (0% vs. 0.6%; p <0.001), and a smaller minimal lumen area (4.71 ± 1.64 vs. 6.00 ± 2.15 mm2; p < 0.001) with NeoVas compared with CoCr-EES respectively, with nonsignificant differences in fractional flow reserve (0.89 ± 0.08 vs. 0.91 ± 0.06; p = 0.07). CONCLUSIONS: The NeoVas BRS was noninferior to CoCr-EES for the primary endpoint of 1-year angiographic in-segment LL, and resulted in comparable 1-year clinical outcomes, including recurrent angina. (NeoVas Bioresorbable Coronary Scaffold Randomized Controlled Trial; NCT02305485).


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Aleaciones de Cromo , Enfermedad de la Arteria Coronaria/cirugía , Estenosis Coronaria/cirugía , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Cateterismo Cardíaco , Fármacos Cardiovasculares/efectos adversos , China , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Enfermedad de la Arteria Coronaria/fisiopatología , Reestenosis Coronaria/etiología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/mortalidad , Estenosis Coronaria/fisiopatología , Trombosis Coronaria/etiología , Everolimus/efectos adversos , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Poliésteres , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Sirolimus/efectos adversos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento
7.
EuroIntervention ; 13(10): 1210-1217, 2017 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-28741576

RESUMEN

AIMS: The EVOLVE China randomised study sought to evaluate the clinical safety and effectiveness of the SYNERGY bioabsorbable polymer-coated everolimus-eluting stent (EES) for the treatment of patients with coronary heart disease in China. METHODS AND RESULTS: Eligible patients with de novo native coronary artery lesions were randomised (1:1) to receive the SYNERGY or PROMUS Element Plus stent. The primary endpoint was in-stent late loss at nine months. Secondary endpoints included death, MI, revascularisation, and stent thrombosis up to 12 months. A total of 412 subjects were randomised (205 SYNERGY; 207 PROMUS Element Plus) at 14 sites in China from October 2013 to July 2014. SYNERGY was non-inferior to PROMUS Element Plus for the primary endpoint of nine-month in-stent late loss: SYNERGY 0.20±0.33 mm vs. PROMUS Element Plus 0.17±0.38 mm with an upper one-sided 97.5% confidence interval of the difference (0.10 mm), significantly less than the non-inferiority margin (0.15 mm; p<0.0008). Clinical adverse event rates were low and not significantly different between groups at nine and 12 months (all p>0.05). CONCLUSIONS: In the EVOLVE China trial, the SYNERGY bioabsorbable polymer-coated EES was noninferior to the PROMUS Element Plus permanent polymer-coated EES for the primary endpoint of late loss at nine months.


Asunto(s)
Stents Liberadores de Fármacos , Everolimus/uso terapéutico , Intervención Coronaria Percutánea , Adolescente , Adulto , Anciano , China , Cromo , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Platino (Metal) , Polímeros/efectos adversos , Sirolimus/uso terapéutico , Resultado del Tratamiento , Adulto Joven
8.
Chem Pharm Bull (Tokyo) ; 55(7): 1011-3, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17603191

RESUMEN

Newly synthesized polymer-supported chiral amino alcohol catalysts 5a and 5b have been proved to be effective for the enantioselective addition of diethylzinc to aldehydes, affording the corresponding sec-alcohols in moderate enantiomeric excesses with good to excellent yields. The recycled catalyst could be reused in the same reaction without significant deterioration in performance.


Asunto(s)
Aldehídos/química , Compuestos Organometálicos/química , Polímeros/química , Catálisis , Estructura Molecular , Estereoisomerismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA