Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Clin Oral Investig ; 27(3): 1193-1206, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36585527

RESUMEN

OBJECTIVES: To investigate the effects of blood and platelet-rich fibrin (PRF), commonly used scaffolds in regenerative endodontic treatment (RET), on the hydration, microstructure, and color stability of three hydraulic calcium silicate cements (HCSCs), OrthoMTA, RetroMTA, and TotalFill-BC-RRM. MATERIALS AND METHODS: The HCSCs were prepared and placed into polyethylene molds and transferred to Eppendorf tubes containing PRF, blood, or PBS and then incubated for 1 week or 1 month. The microstructure and hydration of the cements were studied by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray diffraction (XRD). The chromatic alteration of materials was also measured using a spectrophotometer. The data for color stability were analyzed using 2-way analysis of variance and Tukey post hoc tests. RESULTS: There was no significant difference between the color stability of cements exposed to PBS (p > 0.05). The chromatic alteration of cements exposed to blood was significantly greater than those exposed to PRF and PBS (p < 0.001). In the presence of blood and PRF, the color change of OrthoMTA was significantly greater than that of RetroMTA and TotalFill (p < 0.05), with no significant difference between RetroMTA and TotalFill (p > 0.05). XRD analysis of all cements revealed a calcium hydroxide peak after 1-week and 1-month exposure to the media; however, OrthoMTA and TotalFill exposed to blood and PRF for 1 month showed weaker calcium hydroxide peaks. SEM images revealed cements exposed to PBS had a different surface microstructure compared to those exposed to blood and PRF. Furthermore, the surface microstructure of HCSCs was influenced by the type of cement radiopacifier (bismuth oxide or zirconium oxide). EDS analysis of the elemental composition in all groups displayed peaks of Ca, O, C, Si, P, and Al. CONCLUSIONS: Color stability, hydration behavior, and microstructure of HCSCs were affected by exposure to PRF and blood and the type of cement radiopacifier. CLINICAL RELEVANCE: As some important physicochemical properties of HCSCs could be influenced by the environmental conditions and the type of radiopacifier, alternatives to blood clot and HCSCs containing substitutes for bismuth oxide might be more suitable in RETs.


Asunto(s)
Hidróxido de Calcio , Fibrina Rica en Plaquetas , Hidróxido de Calcio/química , Propiedades de Superficie , Ensayo de Materiales , Compuestos de Calcio/química , Óxidos/química , Silicatos/química , Cementos Dentales/química , Combinación de Medicamentos , Compuestos de Aluminio/química
2.
J Indian Prosthodont Soc ; 21(2): 186-191, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33938869

RESUMEN

Aim: The aim is to study the effect of freshly placed composite build-ups on setting of additional silicone impression materials. Settings and Design: In vitro - experimental study. Materials and Methods: Three composite materials; Build-It™ F. R™, Filtek™ Bulk Fill flow and Filtek™ Z350 and three light-bodied additional silicone impression materials; Elite HD+, Aquasil LV Ultra and Express™ were used. Cylindrical-shaped specimens were made of each material (diameter 15 mm and height 10 mm). The silicone specimens were brought into contact with the composite specimens, which were either freshly cured (9 groups, n = 90) or cured and then stored in normal saline for 1 week (9 groups, n = 90). Shore A hardness (SAH) scores of silicone surfaces were recorded following the ASTM D2240-5 standards for shore A Durometer testing. Six measurements were made per each silicone surface and medians were calculated. Kruskal-Wallis and Mann-Whitney tests (SPSS v20) were used to check statistical significant differences between all groups and paired comparisons, respectively (P < 0.05). Statistical Analysis Used: Kruskal-Wallis and Mann-Whitney tests. Results: The SAH scores of additional silicones in direct contact with freshly placed composites were significantly less than SAH scores of additional silicones in direct contact with composites specimens aged for 1 week in 7 out of 9 combinations (P < 0.05). Only when Express™ and Elite HD+ were applied over freshly placed Filtek™ Bulk Fill flow, the SAH scores difference was not statistically significant to SAH scores of matching combinations applied after 1 week of composite storage. Conclusions: Freshly placed composite might affect setting of additional silicone impression materials. Dentists should carefully assess final impression on areas of prepared teeth that have received composite fillings recently.


Asunto(s)
Silicio , Siliconas , Anciano , Dureza , Humanos , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA