Photon irradiation facilities are often shielded using lead despite its toxicity and high cost. In this study, three Monte Carlo codes, EGS5, MCNPX, and Geant4, were utilized to investigate the efficiency of a relatively new polymeric base compound (CnH2n), as a radiation shielding material for photons with energies below 150 keV. The proposed compound with the densities of 6 and 8 g cm-3 were doped with the weight percentages of 8.0 and 15.0% gadolinium. The probabilities of photoelectric effect and Compton scattering were relatively equal at low photon energies, thus the shielding design was optimized using three Monte Carlo codes for the conformity of calculation results. Consequently, 8% Gd-doped polymer with thickness less than 2 cm and density of 6 g cm-3 was adequate for X-ray room shielding to attenuate more than 95% of the 150-keV incident photons. An average dose rate reduction of 88% can be achieved to ensure safety of the radiation area.