Clin Oral Investig ; 28(1): 18, 2023 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-38135801

RESUMEN

OBJECTIVE: This diagnostic accuracy study aims to present the first measurements of gingiva thickness around lower anterior teeth using dental magnetic resonance imaging (MRI) and to compare these measurements with two established methods: (1) gingival phenotype assessment via periodontal probing, and (2) the superimposition of cone-beam computed tomography (CBCT) scans with intraoral scans of teeth and gums. MATERIALS AND METHODS: Ten patients with substantial orthodontic treatment need and anterior mandibular crowding were consecutively included in this clinical case series. After periodontal probing, each patient underwent a CBCT scan, an intraoral scan of the mandible, and an MRI investigation using a novel mandibula 15-channel dental coil. RESULTS: The mean gingiva thickness was 0.72 mm measured on MRI and 0.97 mm measured on CBCT, with a mean difference between the measurement methods of 0.17 ± 0.27 mm (p < 0.001). Measurement agreement between the index tests (MRI and CBCT) and the clinical reference standard (probing) yielded an overall percent agreement of 64.94% and 47.02% for MRI and CBCT, respectively. Teeth with thin phenotypes were associated with lower soft tissue dimensions in both free (MRI: 0.56 mm vs. CBCT: 0.79 mm) and supracrestal gingiva (MRI: 0.75 mm vs. CBCT: 1.03 mm) when compared to those with thick phenotypes. However, only the measurements obtained from MRI scans showed statistically significant differences between the two phenotypes. CONCLUSION: Dental MRI successfully visualizes delicate structures like the gingiva in the anterior mandible and achieves a high correlation with superimposed CBCT scans, with clinically acceptable deviations. CLINICAL RELEVANCE: The present study helps to establish dental MRI as a radiation-free alternative to conventional radiographic methods.


Asunto(s)
Encía , Maloclusión , Humanos , Encía/diagnóstico por imagen , Mandíbula/diagnóstico por imagen , Incisivo , Examen Físico , Tomografía Computarizada de Haz Cónico/métodos
2.
Clin Oral Implants Res ; 32(2): 154-166, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33220104

RESUMEN

OBJECTIVES: The aim of this study was to evaluate thermal effects of ceramic and metal implant drills during implant site preparation using a standardised bovine model. MATERIAL AND METHODS: A total of 320 automated intermittent osteotomies of 10- and 16-mm drilling depths were performed using zirconium dioxide-based and stainless steel drills. Various drill diameters (2.0/ 2.2, 2.8, 3.5, 4.2 mm ∅) and different cooling methods (without/ with external saline irrigation) were investigated at room temperature (21 ± 1°C). Temperature changes were recorded in real time using two custom-built multichannel thermoprobes in 1- and 2-mm distance to the osteotomy site. For comparisons, a linear mixed model was estimated. RESULTS: Comparing thermal effects, significantly lower temperatures could be detected with steel-based drills in various drill diameters, regardless of drilling depth or irrigation method. Recorded temperatures for metal drills of all diameters and drilling depths using external irrigation were below the defined critical temperature threshold of 47°C, whereas ceramic drills of smaller diameters reached or exceeded the harmful temperature threshold at 16-mm drilling depths, regardless of whether irrigation was applied or not. The results of this study suggest that the highest temperature changes were not found at the deepest point of the osteotomy site but were observed at subcortical and deeper layers of bone, depending on drill material, drill diameter, drilling depth and irrigation method. CONCLUSIONS: This standardised investigation revealed drill material and geometry to have a substantial impact on heat generation, as well as external irrigation, drilling depth and drill diameter.


Asunto(s)
Osteotomía , Acero Inoxidable , Animales , Huesos , Bovinos , Cerámica , Implantación Dental Endoósea , Calor , Temperatura
3.
Clin Oral Investig ; 25(4): 1869-1877, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32951123

RESUMEN

OBJECTIVES: LAY-FOMM is a promising material for FDA-approved Fused Deposition Modeling (FDM) applications in drug delivery. Here we investigated the impact on oral cells. MATERIALS AND METHODS: We evaluated the impact of 3D-printed LAY-FOMM 40, LAY-FOMM 60, and biocompatible polylactic acid (PLA) on the activity of murine L929 cells, gingival fibroblasts (GF), and periodontal ligament fibroblasts (PDLF) using indirect (samples on cells), direct monolayer culture models (cells on samples), and direct spheroid cultures with resazurin-based toxicity assay, confirmed by MTT and Live-dead staining. The surface topography was evaluated with scanning electron microscopy. RESULTS: The materials LAY-FOMM 40 and LAY-FOMM 60 led to a reduction in resazurin conversion in L929 cells, GF, and PDLF, higher than the impact of PLA in indirect and direct culture models. Fewer vital cells were found in the presence of LAY-FOMM 40 and 60 than PLA, in the staining in both models. In the direct model, LAY-FOMM 40 and PLA showed less impact on viability in the resazurin-based toxicity assay than in the indirect model. Spheroid microtissues showed a reduction of cell activity of GF and PDLF with LAY-FOMM 40 and 60. CONCLUSION: Overall, we found that LAY-FOMM 40 and LAY-FOMM 60 can reduce the activity of L292 and oral cells. Based on the results from the PLA samples, the direct model seems more reliable than the indirect model. CLINICAL RELEVANCE: A material modification is desired in terms of biocompatibility as it can mask the effect of drugs and interfere with the function of the 3D-printed device.


Asunto(s)
Fibroblastos , Encía , Animales , Células Cultivadas , Humanos , Ratones , Ligamento Periodontal , Impresión Tridimensional
4.
Sensors (Basel) ; 21(18)2021 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-34577474

RESUMEN

BACKGROUND: The preparation of bone for the insertion of an osseointegrated transfemoral implant and the insertion process are performed at very low speeds in order to avoid thermal damages to bone tissue which may potentially jeopardize implant stability. The aim of this study was to quantify the temperature increase in the femur at different sites and insertion depths, relative to the final implant position during the stepwise implantation procedure. METHODS: The procedure for installation of the osseointegrated implant was performed on 24 femoral specimens. In one specimen of each pair, the surgery was performed at the clinically practiced speed, while the speed was doubled in the contralateral specimen. Six 0.075 mm K fine gauge thermocouples (RS Components, Sorby, UK) were inserted into the specimen at a distance of 0.5 mm from the final implant surface, and six were inserted at a distance of 1.0 mm. RESULTS: Drilling caused a temperature increase of <2.5 °C and was not statistically significantly different for most drill sizes (0.002 < p < 0.845). The mean increase in temperature during thread tapping and implant insertion was <5.0 °C, whereas the speed had an effect on the temperature increase during thread tapping. CONCLUSIONS: Drilling is the most time-consuming part of the surgery. Doubling the clinically practiced speed did not generate more heat during this step, suggesting the speed and thus the time- and cost-effectiveness of the procedure could be increased. The frequent withdrawal of the instruments and removal of the bone chips is beneficial to prevent temperature peaks, especially during thread tapping.


Asunto(s)
Prótesis Anclada al Hueso , Implantes Dentales , Temperatura Corporal , Huesos , Calor , Temperatura , Termómetros
5.
J Mater Sci Mater Med ; 31(11): 92, 2020 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-33089376

RESUMEN

Screw osteosynthesis using headless compression screws has become the accepted gold standard for the surgical treatment of scaphoid fractures. Optimal screw specifications remain controversially discussed. We aimed to investigate the influence of bone model composition on screw stability tests using headless compression screws in different scaphoid fracture models. We conducted pull-out tests using Acutrak2®mini, HCS®, HKS®, HBS®, Herbert/Whipple® and Twinfix® screws. To imitate cortical and cancellous bone, two-layer polyurethane (PU) models with two distinct densities were produced. The cylinders were cut at different positions to replicate fracture localisations at increasing distances. The maximum pull-out force required to achieve up to 1 mm of pull-out distance (Nto 1 mm) was measured. Acutrak2®mini and HCS® followed by Twinfix® showed the greatest average pull-out forces. Nto 1 mm was, on average, greater in the cortico-cancellous model than in the cancellous cylinder with the Acutrak2®mini and the Herbert/Whipple® screws, while it was the least with the HBS® and the Twinfix® screws; there were also differences between the HCS® and HKS®. There were no differences between the different fracture simulations in the synthesis strength using either the HKS® or HBS®. The pull-out forces of the HCS® and Twinfix® remained high also in simulations with the smaller screw base fragments. Varying imitations of cancellous and cortico-cancellous bone and fracture localisation reveal important information about the ex vivo strength of screw syntheses. The grip of the cortical structure should be used with the screws that fit more firmly in cortico-cancellous bone.


Asunto(s)
Tornillos Óseos , Huesos/fisiología , Fracturas Óseas/cirugía , Hueso Escafoides/cirugía , Fenómenos Biomecánicos , Fuerza Compresiva , Diseño de Equipo , Fijación Interna de Fracturas , Humanos , Análisis de los Mínimos Cuadrados , Ensayo de Materiales , Poliuretanos/química , Presión , Estrés Mecánico
6.
Clin Oral Implants Res ; 25(5): 622-31, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-23347297

RESUMEN

OBJECTIVES: Based on a novel standardized bovine specimen, the aim of this study was to investigate thermal effects of different irrigation methods during intermittent and graduated drilling. MATERIAL AND METHODS: Temperature changes during implant osteotomies (n = 320) of 10 and 16 mm drilling depths with various irrigation methods were investigated on manufactured uniform bone samples providing homogenous cortical and cancellous areas and analogous thermal conductivity comparable to human bone. Automated sequences were performed with surgical twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. Real-time recording of temperature increase was done using two custom-built multichannel thermoprobes with 14 temperature sensors at a predefined distance of 1 and 2 mm to the final osteotomy. The effects of drilling depth, drilling diameter and irrigation methods on temperature changes were investigated by a linear mixed model. RESULTS: Using this uniform bone specimen, the greatest temperature rise was observed without any coolant supply with 29.87°C, followed by external with 28.47°C and then internal with 25.86°C and combined irrigation with 25.68°C. Significant differences (P ≤ 0.0156) between drill depths of 10 vs. 16 mm could be observed with all irrigation methods evaluated. With each of the irrigation methods, significantly higher temperature changes (P < 0.0001) during osteotomies could be observed between twist drills of 2 mm ∅ and conical drills of 3.5, 4.3 and 5 mm ∅. During 10 and 16 mm drilling osteotomies, external irrigation showed significantly higher temperatures (P < 0.05) for all conical drills compared with internal or combined irrigation, respectively. Significantly lower temperatures (P < 0.05) could be detected with internal or combined irrigation for the use of conical drills with various diameters and drilling depths. CONCLUSIONS: This fully standardized bone model provides optimized comparability for the evaluation of bone osteotomies and resulting temperature changes. As regards the efficiency of the various irrigation methods, it could be demonstrated that internal and combined irrigation appears to be more beneficial than external irrigation.


Asunto(s)
Sustitutos de Huesos/química , Osteotomía , Irrigación Terapéutica , Conductividad Térmica , Animales , Bovinos , Técnicas In Vitro , Temperatura
7.
Clin Implant Dent Relat Res ; 25(1): 152-165, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36369670

RESUMEN

INTRODUCTION: Excessive surgical trauma is believed to be among the most important causes for early implant losses. As thermal injury to the bone is not only dependent on the amount of generated heat but also on the tissue exposure time, and the greatest temperature increase was found within the withdrawing period, the entire osteotomy procedure with the parameters contributing to thermal damage is of particular clinical relevance. The aim of this study was to investigate the thermal performance of metal-based and ceramic implant drills regarding the temperature exposure time during the whole osteotomy process. MATERIALS AND METHODS: This investigation consisted of 240 individual preparations in total, comprising two different drilling depths (10 and 16 mm), two irrigation methods (external and without irrigation), two implant drill materials (stainless steel and zirconia), and three consecutive drill diameters per material (2.0/2.2, 2.8, and 3.5 mm) with 10 identical repetitions. Real-time multichannel temperature measurement was conducted during automated drilling procedures in standardized bovine bone specimens. RESULTS: The maximum temperature changes were highly associated with the time period of passive drill withdrawing (p ≤ 0.05), irrespective of drill material, drilling depth, or drill diameter. Statistically significant differences in temperature generation between stainless steel and ceramic drills were observed in irrigated testing sites at both drilling depths with smaller drill diameters (2.0/2.2 and 2.8 mm, p ≤ 0.05). CONCLUSION: Results of this in vitro study could demonstrate a strong association between the highest temperature increase and the passive withdrawing time period in both investigated drill materials. Considering these findings and the resulting thermal bone damage due to the whole surgical procedure, high overall temperatures in combination with a prolonged heat exposure time may impact the future osseointegration process.


Asunto(s)
Implantes Dentales , Acero Inoxidable , Animales , Bovinos , Temperatura , Calor , Implantación Dental Endoósea/efectos adversos , Implantación Dental Endoósea/métodos , Cerámica
8.
Front Vet Sci ; 10: 1165689, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37065217

RESUMEN

Conventional plate osteosynthesis of critical-sized bone defects in canine mandibles can fail to restore former functionality and stability due to adaption limits. Three-dimensional (3D) printed patient-specific implants are becoming increasingly popular as these can be customized to avoid critical structures, achieve perfect alignment to individual bone contours, and may provide better stability. Using a 3D surface model for the mandible, four plate designs were created and evaluated for their properties to stabilize a defined 30 mm critical-size bone defect. Design-1 was manually designed, and further shape optimized using Autodesk ® Fusion 360 (ADF360) and finite element analysis (FE) to generate Design-2. Design-4 was created with the generative design (GD) function from ADF360 using preplaced screw terminals and loading conditions as boundaries. A 12-hole reconstruction titanium locking plate (LP) (2.4/3.0 mm) was also tested, which was scanned, converted to a STL file and 3D printed (Design-3). Each design was 3D printed from a photopolymer resin (VPW) and a photopolymer resin in combination with a thermoplastic elastomer (VPWT) and loaded in cantilever bending using a customized servo-hydraulic mechanical testing system; n = 5 repetitions each. No material defects pre- or post-failure testing were found in the printed mandibles and screws. Plate fractures were most often observed in similar locations, depending on the design. Design-4 has 2.8-3.6 times ultimate strength compared to other plates, even though only 40% more volume was used. Maximum load capacities did not differ significantly from those of the other three designs. All plate types, except D3, were 35% stronger when made of VPW, compared to VPWT. VPWT D3 plates were only 6% stronger. Generative design is faster and easier to handle than optimizing manually designed plates using FE to create customized implants with maximum load-bearing capacity and minimum material requirements. Although guidelines for selecting appropriate outcomes and subsequent refinements to the optimized design are still needed, this may represent a straightforward approach to implementing additive manufacturing in individualized surgical care. The aim of this work is to analyze different design techniques, which can later be used for the development of implants made of biocompatible materials.

9.
Int J Oral Maxillofac Implants ; 30(5): 1041-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26394339

RESUMEN

PURPOSE: To quantify the reliability of a new drilling system for implant osteotomy characterized by an eccentric sensor that automatically stops the drill upon contact with soft tissue. This safety mechanism aims to minimize surgical trauma to nerves, vessels, and the maxillary sinus mucosa. The benefits of the eccentric sensor position on planar and angulated surfaces were tested in vitro. MATERIALS AND METHODS: Predicted drill protrusion after auto-stop was validated against experiments on four human cadaver mandibles (30 osteotomies with varying angles). Measurement of the drill's exit holes allowed calculation of the amount of drill protrusion, and postoperative computed tomographic scans of the mandibles were acquired to determine the drill's exit angles. RESULTS: Mean drill protrusion into human jawbone was 0.46 ± 0.26 mm and differed significantly from expected drill protrusion, which was based on mathematical modeling, of 0.64 ± 0.3 mm. Detection of bone passage on angulated walls was seen up to 71 degrees. A central sensor position, by contrast, may result in significantly greater drill protrusion into soft tissue (mean difference: 0.55 ± 0.49 mm) that increases with the drill's exit angle (r = 0.93). CONCLUSION: Auto-stop drills may significantly enhance safety for the patient during osteotomy. The benefits of eccentric sensor positioning were particularly apparent when applied on angulated surfaces, whereas drill angulation was not found to influence this safety mechanism.


Asunto(s)
Implantación Dental Endoósea/instrumentación , Osteotomía/instrumentación , Algoritmos , Cadáver , Equipos y Suministros Eléctricos , Diseño de Equipo , Humanos , Mandíbula/diagnóstico por imagen , Mandíbula/cirugía , Ensayo de Materiales , Modelos Biológicos , Reproducibilidad de los Resultados , Rotación , Tomografía Computarizada por Rayos X/métodos