Catheter Cardiovasc Interv ; 101(1): 33-43, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36480798

RESUMEN

BACKGROUND: Whether the drug-coated balloons (DCBs)-alone strategy was superior to plain old balloon angioplasty (POBA) in treating SVD remains unknown. AIMS: We aimed to evaluate the efficacy and safety of DCBs for the treatment of coronary de novo small vessel disease (SVD) and provide further evidence for extending the clinical indications of DCBs. (ChiCTR1800014966). METHODS: Eligible patients were randomized at a 2:1 ratio to receive DCB treatment or POBA in this prospective, multicenter clinical trial. The reference vessel diameter of lesions was visually assessed to be 2.0 to 2.75 mm. The primary endpoint of the study was angiographic in-segment late luminal loss (LLL) at the 9-month follow-up to demonstrate the superiority of DCB treatment to POBA in SVD. The composite clinical endpoints included clinically driven target lesion revascularization (CD-TLR), target lesion failure (TLF), major adverse cardiac events (MACEs), and thrombosis at the 12-month follow-up. RESULTS: A total of 270 patients were enrolled (181 for DCB, 89 for POBA) at 18 centers in China. The primary endpoint of 9-month in-segment LLL in the intention-to-treat population was 0.10 ± 0.33 mm with DCB and 0.25 ± 0.38 mm with POBA (p = 0.0027). This difference indicated significant superiority of DCB treatment (95% CI: -0.22, -0.04, psuperiority = 0.0068). The rates of the clinical endpoints-CD-TLR, TLF, and MACEs-were comparable between groups. No thrombosis events were reported. CONCLUSIONS: DCB treatment of de novo SVD was superior to POBA with lower 9-month in-segment LLL. The rates of clinical events were comparable between the two devices.


Asunto(s)
Angioplastia Coronaria con Balón , Angioplastia de Balón , Enfermedad de la Arteria Coronaria , Enfermedades Vasculares , Humanos , Estudios Prospectivos , Resultado del Tratamiento , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Enfermedades Vasculares/etiología , Materiales Biocompatibles Revestidos , Paclitaxel/efectos adversos
2.
Catheter Cardiovasc Interv ; 97 Suppl 2: 988-995, 2021 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-33734575

RESUMEN

OBJECTIVES: This study sought to compare the efficacy and clinical safety of the LONGTY drug-coated balloon (DCB) with those of SeQuent Please DCB in patients with in-stent restenosis (ISR). BACKGROUND: Although DCB technologies have evolved, little is known about the clinical efficacy of the new-generation LONGTY DCB. METHODS: This was a prospective, multicenter, randomized, noninferiority trial comparing LONGTY DCB with SeQuent Please DCB in patients with ISR. The primary endpoint was target lesion late lumen loss at 9 months' follow-up. RESULTS: A total of 211 patients with ISR from 13 Chinese sites were included (LONGTY DCB, n = 105; SeQuent Please DCB, n = 106). Device success was achieved in all patients. At the 9 month angiographic follow-up, target lesion late lumen loss was 0.35 ± 0.42 mm with LONGTY and 0.38 ± 0.45 mm with SeQuent Please (p for noninferiority <.001). The target lesion revascularization rates at 1 year were similar in both DCB groups (15.24 vs. 13.21%; p = .673). Over an extended follow-up of 2 years, the clinical endpoints, including cardiac death, myocardial infarction, and thrombus rate, were extremely low and similar in both groups. CONCLUSIONS: In this multicenter, head-to-head, randomized trial, the new-generation LONGTY DCB was noninferior to the SeQuent Please DCB for the primary endpoint of target lesion late lumen loss at 9 months.


Asunto(s)
Angioplastia Coronaria con Balón , Fármacos Cardiovasculares , Reestenosis Coronaria , Stents Liberadores de Fármacos , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , China , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia , Humanos , Paclitaxel/efectos adversos , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 87 Suppl 1: 624-9, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26775079

RESUMEN

BACKGROUND: The PEPCAD China ISR trial investigated the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in an Asian patient population with coronary drug-eluting stent in-stent restenosis (DES-ISR). METHODS: A total of 220 patients with coronary DES-ISR were treated with PCB angioplasty or with paclitaxel-eluting stents (PES). This randomized (1:1), single-blind prospective multicenter trial in a Chinese population used 9-month in-segment late lumen loss (LLL) as the primary endpoint. Secondary endpoints included the 24-month clinical event rates. RESULTS: Both treatment groups were similar in terms of patient, lesion, or procedural characteristics. After the 12-month follow-up evaluation, additional clinical events only occurred in the PES study group. The combined rate of all-cause mortality and myocardial infarction (MI) in the PCB group was significantly lower than that in the PES group (3.7% vs. 11.8%, P = 0.03). Additional subgroup analyses of 9-month in-segment LLL and 2-year target lesion failure in patients with diabetes, small vessels, diffuse ISR, and stent margin restenosis did not show more favorable results for one specific treatment group. CONCLUSIONS: The 2-year follow-up demonstrated sustained long-term clinical efficacy for both devices. PCB angioplasty was associated with significantly lower overall and cardiovascular mortality/MI rates in patients with DES-ISR lesions while avoiding the use of additional metal layers for drug release (ClinicalTrials.gov identifier: NCT 01622075).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , China , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/mortalidad , Humanos , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
4.
Biomater Sci ; 12(10): 2717-2729, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38619816

RESUMEN

Polymeric heart valves (PHVs) present a promising alternative for treating valvular heart diseases with satisfactory hydrodynamics and durability against structural degeneration. However, the cascaded coagulation, inflammatory responses, and calcification in the dynamic blood environment pose significant challenges to the surface design of current PHVs. In this study, we employed a surface-initiated polymerization method to modify polystyrene-block-isobutylene-block-styrene (SIBS) by creating three hydrogel coatings: poly(2-methacryloyloxy ethyl phosphorylcholine) (pMPC), poly(2-acrylamido-2-methylpropanesulfonic acid) (pAMPS), and poly(2-hydroxyethyl methacrylate) (pHEMA). These hydrogel coatings dramatically promoted SIBS's hydrophilicity and blood compatibility at the initial state. Notably, the pMPC and pAMPS coatings maintained a considerable platelet resistance performance after 12 h of sonication and 10 000 cycles of stretching and bending. However, the sonication process induced visible damage to the pHEMA coating and attenuated the anti-coagulation property. Furthermore, the in vivo subcutaneous implantation studies demonstrated that the amphiphilic pMPC coating showed superior anti-inflammatory and anti-calcification properties. Considering the remarkable stability and optimal biocompatibility, the amphiphilic pMPC coating constructed by surface-initiated polymerization holds promising potential for modifying PHVs.


Asunto(s)
Materiales Biocompatibles Revestidos , Hidrogeles , Fosforilcolina , Propiedades de Superficie , Fosforilcolina/química , Fosforilcolina/análogos & derivados , Fosforilcolina/farmacología , Animales , Hidrogeles/química , Hidrogeles/farmacología , Materiales Biocompatibles Revestidos/química , Materiales Biocompatibles Revestidos/farmacología , Ensayo de Materiales , Polihidroxietil Metacrilato/química , Ácidos Polimetacrílicos/química , Ácidos Polimetacrílicos/farmacología , Metacrilatos/química , Polímeros/química , Polímeros/farmacología , Prótesis Valvulares Cardíacas , Válvulas Cardíacas/efectos de los fármacos , Humanos , Ratones , Interacciones Hidrofóbicas e Hidrofílicas
6.
J Am Coll Cardiol ; 67(19): 2249-2258, 2016 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-27173037

RESUMEN

BACKGROUND: Whether the rate of drug elution and polymer absorption affects clinical outcomes of biodegradable polymer-based drug-eluting stents (DES) is unknown. The widely used polylactide polymer-based Excel stent (JW Medical, Weihai, China) elutes sirolimus within 180 days, and the polylactide polymer is completely absorbed within 6 to 9 months. In contrast, the poly-lactide-co-glycolide polymer-based BuMA stent (Sino Medical, Tianjin, China) elutes sirolimus within 30 days, and the poly-lactide-co-glycolide polymer is completely absorbed within 3 months. Thus, both metallic DES elute sirolimus, isolating major differences to the polymer and elution kinetics. OBJECTIVES: The goal of this study was to compare the safety and effectiveness between the BuMA sirolimus-eluting stent (SES) and Excel SES in an "all-comers" population. METHODS: PANDA III was a multicenter trial with few exclusion criteria, powered for sequential noninferiority and superiority testing. The primary endpoint was 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: Between December 2013 and August 2014, 2,348 patients were randomly assigned to treatment with BuMA (n = 1,174) or Excel SES (n = 1,174). The 1-year primary endpoint of TLF occurred in 6.4% of patients in each group (difference: 0.06%; 95% confidence interval: 1.93% to 2.04%; pnoninferiority = 0.0003; psuperiority = 0.95). There were no significant between-group differences in any of the secondary endpoints other than the incidence of definite/probable stent thrombosis, which occurred less frequently with the BuMA stent (0.5% vs. 1.3%; log-rank p = 0.048). CONCLUSIONS: The BuMA SES was demonstrated to be noninferior to the Excel SES for 1-year TLF, with a lower incidence of stent thrombosis. (Comparison of BuMA eG Based BioDegradable Polymer Stent With EXCEL Biodegradable Polymer Sirolimus-eluting Stent in "Real-World" Practice [PANDA-III]; NCT02017275).


Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Poliésteres/química , Polímeros/química , Enfermedad de la Arteria Coronaria/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Revascularización Miocárdica/estadística & datos numéricos , Intervención Coronaria Percutánea , Estudios Prospectivos , Diseño de Prótesis , Sirolimus , Trombosis/etiología
7.
JACC Cardiovasc Interv ; 7(2): 204-211, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24556098

RESUMEN

OBJECTIVES: The intention of the PEPCAD China ISR (A Prospective, Multicenter, Randomized Trial of Paclitaxel-Coated versus Paclitaxel-Eluting Stent for the Treatment of Drug-Eluting Stent In-Stent Restenosis) was to demonstrate the efficacy of paclitaxel-coated balloon (PCB) angioplasty in a non-European patient population with coronary drug-eluting stent in-stent restenosis (DES-ISR). BACKGROUND: The treatment of DES-ISR is still challenging with no established best strategy. Moreover, there is no study on the effect of PCB in the treatment of ISR in the Chinese population. METHODS: PEPCAD China ISR was a 220-patient randomized (1:1), single-blind prospective multicenter trial conducted in China. Patients with coronary DES-ISR received either PCB (SeQuent Please, B. Braun Melsungen AG, Melsungen, Germany) or paclitaxel-eluting stent (Taxus Liberté, Boston Scientific, Natick, Massachusetts) treatment. The primary endpoint was in-segment late lumen loss at 9 months. RESULTS: There were no significant baseline differences between both treatment groups in terms of patient, lesion, or procedural characteristics. At 9 months, in-segment late lumen loss in the PCB group was noninferior to that of the paclitaxel-eluting stent group (0.46 ± 0.51 mm vs. 0.55 ± 0.61 mm; difference: -0.06 mm with 95% confidence interval: -0.23 to 0.10; p for noninferiority = 0.0005). The 9-month rate of binary restenosis and 12-month composite clinical event rates were not significantly different between groups. CONCLUSIONS: In a randomized trial of 220 patients, angioplasty with a PCB was noninferior to paclitaxel-eluting stent implantation when used to treat DES-ISR. On the basis of these, as well as previous randomized trial data, PCB angioplasty offers an effective treatment for DES-ISR without the necessity of implanting additional metal layers for drug release. (A Safety and Efficacy Study of Paclitaxel-Eluting Balloon to Paclitaxel-Eluting Stent [PEPCAD]; NCT01622075).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Dispositivos de Acceso Vascular , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , China , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Recurrencia , Factores de Riesgo , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS