Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Más filtros

País/Región como asunto
Intervalo de año de publicación
1.
Nature ; 609(7929): 964-968, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36171375

RESUMEN

Mandibular teeth and dentitions are features of jawed vertebrates that were first acquired by the Palaeozoic ancestors1-3 of living chondrichthyans and osteichthyans. The fossil record currently points to the latter part of the Silurian period4-7 (around 425 million years ago) as a minimum date for the appearance of gnathostome teeth and to the evolution of growth and replacement mechanisms of mandibular dentitions in the subsequent Devonian period2,8-10. Here we provide, to our knowledge, the earliest direct evidence for jawed vertebrates by describing Qianodus duplicis, a new genus and species of an early Silurian gnathostome based on isolated tooth whorls from Guizhou province, China. The whorls possess non-shedding teeth arranged in a pair of rows that demonstrate a number of features found in modern gnathostome groups. These include lingual addition of teeth in offset rows and maintenance of this patterning throughout whorl development. Our data extend the record of toothed gnathostomes by 14 million years from the late Silurian into the early Silurian (around 439 million years ago) and are important for documenting the initial diversification of vertebrates. Our analyses add to mounting fossil evidence that supports an earlier emergence of jawed vertebrates as part of the Great Ordovician Biodiversification Event (approximately 485-445 million years ago).


Asunto(s)
Fósiles , Diente , Vertebrados , Animales , China , Peces/anatomía & histología , Historia Antigua , Filogenia , Diente/anatomía & histología , Vertebrados/anatomía & histología , Vertebrados/clasificación
2.
Nature ; 609(7929): 969-974, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36171377

RESUMEN

Modern representatives of chondrichthyans (cartilaginous fishes) and osteichthyans (bony fishes and tetrapods) have contrasting skeletal anatomies and developmental trajectories1-4 that underscore the distant evolutionary split5-7 of the two clades. Recent work on upper Silurian and Devonian jawed vertebrates7-10 has revealed similar skeletal conditions that blur the conventional distinctions between osteichthyans, chondrichthyans and their jawed gnathostome ancestors. Here we describe the remains (dermal plates, scales and fin spines) of a chondrichthyan, Fanjingshania renovata gen. et sp. nov., from the lower Silurian of China that pre-date the earliest articulated fossils of jawed vertebrates10-12. Fanjingshania possesses dermal shoulder girdle plates and a complement of fin spines that have a striking anatomical similarity to those recorded in a subset of stem chondrichthyans5,7,13 (climatiid 'acanthodians'14). Uniquely among chondrichthyans, however, it demonstrates osteichthyan-like resorptive shedding of scale odontodes (dermal teeth) and an absence of odontogenic tissues in its spines. Our results identify independent acquisition of these conditions in the chondrichthyan stem group, adding Fanjingshania to an increasing number of taxa7,15 nested within conventionally defined acanthodians16. The discovery of Fanjingshania provides the strongest support yet for a proposed7 early Silurian radiation of jawed vertebrates before their widespread appearance5 in the fossil record in the Lower Devonian series.


Asunto(s)
Peces , Fósiles , Filogenia , Animales , China , Peces/anatomía & histología , Peces/clasificación , Maxilares/anatomía & histología , Diente
3.
Nature ; 609(7929): 954-958, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-36171378

RESUMEN

Molecular studies suggest that the origin of jawed vertebrates was no later than the Late Ordovician period (around 450 million years ago (Ma))1,2. Together with disarticulated micro-remains of putative chondrichthyans from the Ordovician and early Silurian period3-8, these analyses suggest an evolutionary proliferation of jawed vertebrates before, and immediately after, the end-Ordovician mass extinction. However, until now, the earliest complete fossils of jawed fishes for which a detailed reconstruction of their morphology was possible came from late Silurian assemblages (about 425 Ma)9-13. The dearth of articulated, whole-body fossils from before the late Silurian has long rendered the earliest history of jawed vertebrates obscure. Here we report a newly discovered Konservat-Lagerstätte, which is marked by the presence of diverse, well-preserved jawed fishes with complete bodies, from the early Silurian (Telychian age, around 436 Ma) of Chongqing, South China. The dominant species, a 'placoderm' or jawed stem gnathostome, which we name Xiushanosteus mirabilis gen. et sp. nov., combines characters from major placoderm subgroups14-17 and foreshadows the transformation of the skull roof pattern from the placoderm to the osteichthyan condition10. The chondrichthyan Shenacanthus vermiformis gen. et sp. nov. exhibits extensive thoracic armour plates that were previously unknown in this lineage, and include a large median dorsal plate as in placoderms14-16, combined with a conventional chondrichthyan bauplan18,19. Together, these species reveal a previously unseen diversification of jawed vertebrates in the early Silurian, and provide detailed insights into the whole-body morphology of the jawed vertebrates of this period.


Asunto(s)
Fósiles , Maxilares , Vertebrados , Animales , China , Peces/anatomía & histología , Peces/clasificación , Maxilares/anatomía & histología , Filogenia , Cráneo/anatomía & histología , Vertebrados/anatomía & histología , Vertebrados/clasificación
4.
Anal Chem ; 96(28): 11595-11602, 2024 07 16.
Artículo en Inglés | MEDLINE | ID: mdl-38950152

RESUMEN

Timely diagnosis, monitoring, and management of chronic wounds play crucial roles in improving patients' quality of life, but clinical evaluation of chronic wounds is still ambiguous and relies heavily on the experience of clinician, resulting in increased social and financial burden and delay of optimal treatment. During the different stages of the healing process, specific and dynamic changes of pH values in the wound exudate can be used as biomarkers to reflect the wound status. Herein, a pH-responsive agent with well-behaved photoacoustic (PA) properties, nitrazine yellow (NY), was incorporated in poly(vinyl alcohol)/sucrose (PVA/Suc) hydrogel to construct a wearable pH-sensing patch (PVA/Suc/NY hydrogel) for monitoring of pH values during chronic wound healing. According to Rosencwaig-Gersho theory and the combination of 3D printing technology, the PA chamber volume and chopping frequency were systematically optimized to improve the sensitivity of the PA analytical system. The prepared PVA/Suc/NY hydrogel patch had excellent mechanical properties and flexibility and could maintain conformal contact with skin. Moreover, combined with the miniaturized PA analytical device, it had the potential to detect pH values (5.0-9.0) free from the color interference of blood and therapeutic drugs, which provides a valuable strategy for wound pH value monitoring by PA quantitation. This strategy of combining the wearable hydrogel patch with portable PA analysis offers broad new prospects for the treatment and management of chronic wounds due to its features of simple operation, time savings, and anti-interference.


Asunto(s)
Hidrogeles , Técnicas Fotoacústicas , Dispositivos Electrónicos Vestibles , Concentración de Iones de Hidrógeno , Hidrogeles/química , Animales , Cicatrización de Heridas/efectos de los fármacos , Alcohol Polivinílico/química , Humanos
5.
Anal Chem ; 96(29): 12084-12092, 2024 07 23.
Artículo en Inglés | MEDLINE | ID: mdl-39001802

RESUMEN

Near-infrared (NIR) luminescent lanthanide materials hold great promise for bioanalysis, as they have anti-interference properties. The approach of efficient luminescence is sensitization through a reasonable chromophore to overcome the obstacle of the aqueous phase. The involvement of the surfactant motif is an innovative strategy to arrange the amphiphilic groups to be regularly distributed near the polymer to form a closed sensitized space. Herein, a lanthanide polymer (TCPP-PEI70K-FITC@Yb/SDBS) is designed in which the meso-tetra(4-carboxyphenyl)porphine (TCPP) ligand serves as both a sensitizer and photocatalytic switch. The surfactant sodium dodecyl benzenesulfonate (SDBS) wraps the photosensitive polymers to form a hydrophobic layer, which augments the light-harvesting ability and expedites its photocatalysis. TCPP-PEI70K-FITC@Yb/SDBS is subsequently applied as an amplified photocatalysis toolbox for universally regulating the generation of reactive oxygen species (ROS). Boosting 3,3',5,5'-tetramethylbenzidine (TMB) oxidation to produce blue products, a dual-mode biosensor is fabricated for improving the diagnosis of programmed death ligand-1-positive (PDL1) cancer exosomes. Exosomes were captured by Fe3O4 modified by the PDL1 aptamer, enabling replacement of alkaline phosphatase (ALP)-labeled multiple hybridized chains; then, the isolated ALP triggered a hydrolysis reaction to block the generation of oxTMB. Detection sensitivity improves by 1 order of magnitude through SDBS modulation, down to 104 particles/mL. The sensor performed well clinically in distinguishing cancer patients from healthy individuals, expanding physiological applications of near-infrared lanthanide luminescence.


Asunto(s)
Elementos de la Serie de los Lantanoides , Luz , Polímeros , Humanos , Elementos de la Serie de los Lantanoides/química , Polímeros/química , Catálisis , Exosomas/química , Exosomas/metabolismo , Rayos Infrarrojos , Neoplasias/diagnóstico , Procesos Fotoquímicos , Técnicas Biosensibles , Especies Reactivas de Oxígeno/análisis , Especies Reactivas de Oxígeno/metabolismo
6.
Anal Chem ; 96(18): 7155-7162, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38652710

RESUMEN

Microplastics (MPs) can act as carriers of environmental arsenic species into the stomach with food and release arsenic species during digestion, which threatens human health. Herein, an integrated dynamic stomach model (DSM)-capillary electrophoresis-inductively coupled plasma mass spectrometry (CE-ICPMS) is developed for online monitoring of the release and transformation behaviors of arsenic species loaded on MPs (As-MPs) in the simulated human stomach. The 3D-printed DSM with a soft stomach chamber enables the behaviors of gastric peristalsis, gastric and salivary fluid addition, pH adjustment, and gastric emptying (GE) to be controlled by a self-written program after oral ingestion of food with As-MPs. The gastric extract during digestion is introduced into the spiral channel to remove the large particulate impurity and online filtered to obtain the clarified arsenic-containing solution for subsequent speciation analysis of arsenic by CE-ICPMS. The digestion conditions and pretreatment processes of DSM are tracked and validated, and the release rates of As-MPs digested by DSM are compared with those digested by the static stomach model and DSM without GE. The release rate of inorganic arsenic on MPs is higher than that of organic arsenic throughout the gastric digestion process, and 8% of As(V) is reduced to As(III). The detection limits for As(III), DMA, MMA, and As(V) are 0.5-0.9 µg L-1 using DSM-CE-ICPMS, along with precisions of ≤8%. This present method provides an integrated and convenient tool for evaluating the release and transformation of As-MPs during human gastric digestion and provides a reference for exploring the interactions between MPs and metals/metalloids in the human body.


Asunto(s)
Arsénico , Electroforesis Capilar , Espectrometría de Masas , Microplásticos , Estómago , Arsénico/análisis , Humanos , Espectrometría de Masas/métodos , Electroforesis Capilar/métodos , Microplásticos/análisis , Estómago/química , Digestión , Modelos Biológicos
7.
Luminescence ; 39(2): e4689, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38361140

RESUMEN

A new type of polyethyleneimine-protected copper nanoclusters (PEI-CuNCs) is favorably developed by a one-pot method under mild conditions. The obtained PEI-CuNCs is characterized by X-ray diffraction, X-ray photoelectron spectroscopy, transmission electron microscopy, Fourier-transform infrared (FTIR) spectroscopy and other techniques. It is worth noting that the proposed PEI-CuNCs demonstrate a selective response to chromium(VI) over other competitive species. Fluorescence quenching of PEI-CuNCs is determined to be chromium(VI) concentrations dependence with a low limit of detection of 8.9 nM. What is more, the as-developed PEI-CuNCs is further employed in building a detection platform for portable recognition of chromium(VI) in real samples with good accuracy. These findings may offer a distinctive strategy for the development of methods for analyzing and monitoring chromium(VI) and expand their application in real sample monitoring.


Asunto(s)
Cromo , Nanopartículas del Metal , Polietileneimina , Polietileneimina/química , Cobre/química , Espectrometría de Fluorescencia/métodos , Colorantes , Colorantes Fluorescentes/química , Límite de Detección , Nanopartículas del Metal/química
8.
PLoS Pathog ; 17(7): e1009730, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-34252162

RESUMEN

The ancestor of cetaceans underwent a macroevolutionary transition from land to water early in the Eocene Period >50 million years ago. However, little is known about how diverse retroviruses evolved during this shift from terrestrial to aquatic environments. Did retroviruses transition into water accompanying their hosts? Did retroviruses infect cetaceans through cross-species transmission after cetaceans invaded the aquatic environments? Endogenous retroviruses (ERVs) provide important molecular fossils for tracing the evolution of retroviruses during this macroevolutionary transition. Here, we use a phylogenomic approach to study the origin and evolution of ERVs in cetaceans. We identify a total of 8,724 ERVs within the genomes of 25 cetaceans, and phylogenetic analyses suggest these ERVs cluster into 315 independent lineages, each of which represents one or more independent endogenization events. We find that cetacean ERVs originated through two possible routes. 298 ERV lineages may derive from retrovirus endogenization that occurred before or during the transition from land to water of cetaceans, and most of these cetacean ERVs were reaching evolutionary dead-ends. 17 ERV lineages are likely to arise from independent retrovirus endogenization events that occurred after the split of mysticetes and odontocetes, indicating that diverse retroviruses infected cetaceans through cross-species transmission from non-cetacean mammals after the transition to aquatic life of cetaceans. Both integration time and synteny analyses support the recent or ongoing activity of multiple retroviral lineages in cetaceans, some of which proliferated into hundreds of copies within the host genomes. Although ERVs only recorded a proportion of past retroviral infections, our findings illuminate the complex evolution of retroviruses during one of the most marked macroevolutionary transitions in vertebrate history.


Asunto(s)
Evolución Biológica , Cetáceos/virología , Retrovirus Endógenos , Fósiles/virología , Animales , Filogenia , Infecciones por Retroviridae/virología
9.
Macromol Rapid Commun ; 44(5): e2200755, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36433758

RESUMEN

The facile and rapid fabrication of oriented porous polymers is crucial for flexible pressure sensors. Herein, a pressure sensor is developed based on oriented porous polydimethylsiloxane (PDMS) composites for detecting human motion and identifying joint motion patterns. The oriented porous PDMS composite is first constructed through thiol-ene click chemistry and directional freezing within only 30 min, then fabricated by interfacial in situ polymerization of dopamine and pyrrole to generate robust interfaces. As a result, the as-prepared oriented porous PDMS composite is assembled into a pressure sensor that shows potential applications in pressure and human motion detection. Interestingly, a sensor assembled by orthogonally stacking the PDMS composites can be used for joint motion pattern recognition with potential monitoring of football motion due to their directional structures. This facile strategy coupled with the oriented porous structure is expected to help design advanced wearable electronic devices.


Asunto(s)
Dispositivos Electrónicos Vestibles , Humanos , Porosidad , Movimiento (Física) , Polímeros , Dimetilpolisiloxanos/química
10.
Neuroradiology ; 65(1): 215-223, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36394613

RESUMEN

PURPOSE: To describe vertebral artery (VA) variation in patients with or without osseous anomalies at congenital craniovertebral junction (CVJ). METHODS: In the present study, we retrospectively analyzed 258 patients with VA variation who underwent three-dimensional computed tomography angiography (3D CTA) in our hospital from March 2017 to October 2019. RESULTS: Among 258 patients, 180 were accompanied by skeleton structural malformation, including 105 cases of occipital ossification of the atlas, 8 cases of the bipartite atlas, 7 cases of hypoplasia of the posterior arch of the atlas, 45 cases of C2/3 congenital fusion, 2 cases of C2/3/4 congenital fusion, and 13 cases of congenital os odontoid. VA variation was divided into type A (VA variation in the CVJ area without osseous anomalies) and type B (VA variation in the CVJ area with osseous anomalies). There are totally 10 subtypes, including type A1 (atlas occipitalization with VA entrance approach close to middle line, 20.2%); type A2 (atlas occipitalization with VA entrance approach far from middle line, 30.2%); type A3 (first intersegmental VA in C1-C2, 1.9%); type A4 (fenestration of the VA, 2.3%); type A5 (VA bulging type, 6.6%); type A6 (VA exposures with the absence of the posterior atlas arch, 2.3%); type A7 (C2 inner wall type, 0.4%); type A8 (single vertebral artery, 2.3%); type B1 (posterior ponticuli, 2.7%); and type B2 (high-riding VA, 31.4%). CONCLUSION: This study is expected to take the lead in the most comprehensive classification of VA variation.


Asunto(s)
Angiografía por Tomografía Computarizada , Arteria Vertebral , Humanos , Arteria Vertebral/diagnóstico por imagen , Arteria Vertebral/anomalías , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Angiografía
11.
BMC Surg ; 23(1): 354, 2023 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-37980464

RESUMEN

BACKGROUNDS: This study aimed to compare whether Calcium phosphate cement (CPC) promotes the stability of osteoporotic lumbar pedicle screw by enhancer-injecters with different number of holes. METHODS: Through a self-designed bone cement injection device, the pedicle screw canal was strengthened with calcium phosphate bone cement, and divided into 4-hole group, 6-hole group, 8-hole group, straight pore group and the control group. The screw was inserted into the mechanical test module, the Maximum insertion torque and Maximum axial pull-out strength were recorded, and the distribution of calcium phosphate bone cement was analyzed by CT and X-ray. The data results were analyzed using SPSS19.0 statistical software package. RESULTS: The distribution of bone cement in different reinforcement groups was different and showed regularity. The bone cement in the 4-hole group was roughly located in the head 1/3 of the screw, the 6-hole group was located in the middle 1/3 of the screw, and the 8-hole group was located in the caudal 1/3 of the screw. Compared with the control group, the maximum axial pull-out force of screws in the lateral hole and full screw tunnel reinforcement group was significantly increased. There was no significant difference between the 4-hole, 6-hole and straight pore groups. There was no difference in the screw-in torque between the reinforcement groups, and they all increased significantly compared with the control group, and the difference was statistically significant. After the screw was pulled out, the interface between the bone cement and the polyurethane material was fractured, and a tight package was formed with the screw. CONCLUSIONS: Enhancer syringes with different hole numbers combined with CPC bone cement injection can significantly increase the maximum screw pull-out force. The 8-hole group has a smaller pull-out force and is relatively prone to leakage of reinforcing material, which lacks safety in use. The local reinforcement of 4-hole and 6-hole sheath can play a similar role to that of total nail tunnel reinforcement.


Asunto(s)
Cementos para Huesos , Tornillos Pediculares , Humanos , Fenómenos Biomecánicos , Fosfatos de Calcio , Vértebras Lumbares/cirugía
12.
Int Orthop ; 47(1): 209-224, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36331596

RESUMEN

OBJECTIVE: Investigate a novel method for treating irreducible atlantoaxial dislocation (IAAD) or with basilar invagination (BI) by bony deformity osteotomy, remodeling, releasing, and plate fixating through transoral approach. METHOD: From March 2015 to December 2019, 213 consecutive patients diagnosed as IAAD/BI were treated with transoral bony deformity remodeling and releasing combined with plate fixation. The main clinical symptoms include neck pain, headache, numbness of the limbs, weakness, unstable walking, inflexible hand-held objects, and sphincter dysfunction. The bony factors that impact reduction were divided into as follows: type A1 (sloping of upper facet joint in C2), type A2 (osteophyte in lateral mass joints between C1 and C2), type A3 (ball-and-socket deformity of lateral mass joint), type A4 (vertical interlocking between lateral mass joints of C1-C2), type A5 (regional bone fusion in lateral mass joints), type B1 (bony factor hindering reduction between the atlas-dens gap), type B2 (uncinate odontoid deformity), and type B3 (hypertrophic odontoid deformity). All of them were treated with bony deformity osteotomy, remodeling, and releasing techs. RESULT: The operation time was 144 [Formula: see text] 25 min with blood loss of 102 [Formula: see text] 35 ml. The average pre-operative ADI improved from 7.5 [Formula: see text] 3.2 mm pre-surgery to 2.5 [Formula: see text] 1.5 mm post-surgery (p < 0.05). The average VDI improved from 12.3 [Formula: see text] 4.8 mm pre-surgery to 3.3 [Formula: see text] 2.1 mm post-surgery (p < 0.05). The average pre-operative CMA improved from 115 [Formula: see text] 25° pre-surgery to 158 [Formula: see text] 21° post-surgery (p < 0.05); the pre-operative CAA changed from 101 [Formula: see text] 28° pre-surgery to 141 [Formula: see text] 10° post-surgery. After the operation, the clinic symptoms improved, and the JOA score improved from 9.3 [Formula: see text] 2.8 pre-operatively to 13.8 [Formula: see text] 2.5 in the sixth months of follow-up. CONCLUSION: In addition to soft tissue factors, bony obstruction was another important factor impeding atlantoaxial reduction. Transoral bony deformity osteotomy, remodeling, releasing combined with plate fixating was effective in treating IAAD/BI with bony obstruction factors.


Asunto(s)
Articulación Atlantoaxoidea , Luxaciones Articulares , Fusión Vertebral , Humanos , Articulación Atlantoaxoidea/diagnóstico por imagen , Articulación Atlantoaxoidea/cirugía , Placas Óseas , Osteotomía , Luxaciones Articulares/cirugía , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos , Resultado del Tratamiento
13.
Anal Chem ; 94(35): 12111-12119, 2022 09 06.
Artículo en Inglés | MEDLINE | ID: mdl-36000825

RESUMEN

Temperature dynamics reflect the physiological state of cells, and accurate measurement of intracellular temperature helps to understand the biological processes. Herein, we report a novel nanothermometer by conjugating a fluorescent probe 3-ethyl-2-[4-(1,2,2-triphenylvinyl)styryl]benzothiazol-3-ium iodide (TPEBT) with a thermoresponsive polymer poly(N-isopropylacrylamide-co-tetrabutylphosphonium styrenesulfonate) [P(NIPAM-co-TPSS)]. The derived nanoprobe TPEBT-P(NIPAM-co-TPSS) self-assembles into micelles with TPEBT as hydrophobic core and PNIPAM as hydrophilic shell. It exhibits aggregation-induced emission (AIE) at λex/λem = 420/640 nm in aqueous medium with a quantum yield of ΦF 11.9%. The rise in temperature transforms PNIPAM chains from linear to compact spheres to serve as the core of micelles, and meanwhile converts TPEBT from the state of aggregation to dispersion and redistributes in the micellar shell. Temperature-driven phase transition of P(NIPAM-co-TPSS) mediates the reversible aggregation and disaggregation of TPEBT and endows the nanothermometer with temperature-dependent AIE features and favorable sensitivity for temperature sensing in 32-40 °C. TPEBT-P(NIPAM-co-TPSS) is taken up by HeLa cells to distribute mainly in lysosomes. It enables quantitative visualization of in situ thermal dynamics in response to stimuli from carbonyl cyanide 4-(trifluoromethoxy)phenylhydrazone, oligomycin, genipin, and lipopolysaccharide. The real-time monitoring of photothermal-induced intracellular temperature variation is further conducted.


Asunto(s)
Micelas , Polímeros , Células HeLa , Humanos , Transición de Fase , Polímeros/química , Temperatura
14.
BMC Microbiol ; 22(1): 128, 2022 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-35549900

RESUMEN

BACKGROUND: Enteropathogenic Escherichia coli and Salmonella pullorum are two important groups of zoonotic pathogens. At present, the treatment of intestinal pathogenic bacteria infection mainly relies on antibiotics, which directly inhibit or kill the pathogenic bacteria. However, due to long-term irrational, excessive use or abuse, bacteria have developed different degrees of drug resistance. N6, an arenicin-3 derivative isolated from the lugworm, has potent antibacterial activity and is poorly resistant to enzymatic hydrolysis and distribution in vivo. Polyethylene glycol (PEG) is an extensively studied polymer and commonly used in protein or peptide drugs to improve their therapeutic potential. Here, we modified the N-/C-terminal or Cys residue of N6 with liner PEGn of different lengths (n = 2, 6,12, and 24), and the effects of PEGylation of N6 on the stability, toxicity, bactericidal mechanism, distribution and efficacy were investigated in vitro and in vivo. RESULTS: The antimicrobial activity of the peptide showed that PEGylated N6 at the C-terminus (n = 2, N6-COOH-miniPEG) had potent activity against Gram-negative bacteria; PEGylated N6 at the N-terminus and Cys residues showed low or no activity with increasing lengths of PEG. N6-COOH-miniPEG has higher stability in trypsin than the parent peptide-N6. N6-COOH-miniPEG significantly regulated cytokine expression in lipopolysaccharides (LPS)-induced RAW 264.7 cells, and the levels of tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6) and IL-1ß were reduced by 31.21%, 65.62% and 44.12%, respectively, lower than those of N6 (-0.06%, -12.36% and -12.73%); N6-COOH-miniPEG increased the level of IL-10 (37.83%), higher than N6 (-10.21%). The data indicated that N6-COOH-miniPEG has more potent anti-inflammatory and immune-regulatory effect than N6 in LPS-stimulated RAW 264.7 cells. N6-COOH-miniPEG exhibited a much wider biodistribution in mice and prolonged in vivo half-time. FITC-labeled N6-COOH-miniPEG was distributed throughout the body of mice in the range of 0.75 - 2 h after injection, while FITC-labeled N6 only concentrated in the abdominal cavity of mice after injection, and the distribution range was narrow. N6-COOH-miniPEG improved the survival rates of mice challenged with E. coli or S. pullorum, downregulated the levels of TNF-α, IL-6, IL-1ß and IL-10 in the serum of LPS-infected mice, and alleviated multiple-organ injuries (the liver, spleen, kidney, and lung), superior to antibiotics, but slightly inferior to N6. CONCLUSIONS: The antibacterial activity, bactericidal mechanism and cytotoxicity of N6-COOH-miniPEG and N6 were similar. N6-COOH-miniPEG has a higher resistance to trysin than N6. The distribution of N6-COOH-miniPEG in mice was superior to that of N6. In exploring the modulatory effects of antimicrobial peptides on cytokines, N6-COOH-miniPEG had stronger anti-inflammatory and immunomodulatory effects than N6. The results suggested that C-terminal PEGylated N6 may provide an opportunity for the development of effective anti-inflammatory and antibacterial peptides.


Asunto(s)
Infecciones por Escherichia coli , Escherichia coli , Animales , Antibacterianos/química , Antibacterianos/farmacología , Antiinflamatorios/farmacología , Bacterias/metabolismo , Citocinas/metabolismo , Fluoresceína-5-Isotiocianato/farmacología , Interleucina-10/metabolismo , Interleucina-6/metabolismo , Lipopolisacáridos/metabolismo , Ratones , Polietilenglicoles/metabolismo , Polietilenglicoles/farmacología , Salmonella/metabolismo , Distribución Tisular , Factor de Necrosis Tumoral alfa/metabolismo
15.
BMC Musculoskelet Disord ; 23(1): 353, 2022 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-35413830

RESUMEN

BACKGROUND: The study aimed to (1) create a series of pedicle injectors with different number of holes on the sheath especially for the Chinese elderly patients and (2) further investigate the effects of the injectors on the augmentation of pedicle screw among osteoporotic lumbar pedicle channel. METHODS: This study used the biomechanical test module of polyurethane (Pacific Research Laboratory Corp, USA) to simulate the mechanical properties of human osteoporotic cancellous bone. The bone cement injectors were invented based on anatomical parameters of lumbar pedicle in Chinese elderly patients. Mechanical test experiments were performed on the bone cement injectors according to the three groups, namely, a local augmentation group, a full-length augmentation group, and a control group. The local augmentation group included three subgroups including 4-hole group, 6-hole group, and 8-hole group. All holes were laterally placed. The full-length augmentation group was a straight-hole injector. The control group was defined that pedicle screws were inserted without any cement augmentation. Six screws were inserted in each group and the maximum insertion torque was recorded. After 24 h of injecting acrylic bone cement, routine X-ray and CT examinations were performed to evaluate the distribution of bone cement. The axial pull-out force of screws was tested with the help of the material testing system 858 (MTS-858) mechanical tester. RESULTS: The bone cement injectors were consisted of the sheaths and the steel rods and the sheaths had different number of lateral holes. The control group had the lowest maximum insertion torque as compared with the 4-hole, 6-hole, 8-hole, and straight pore groups (P < 0.01), but the differences between the 4-hole, 6-hole, 8-hole, and straight pore groups were no statistical significance. The control group had the lowest maximum axial pull-out force as compared with the other four groups (P < 0.01). Subgroup analysis showed the 8-hole group (161.35 ± 27.17 N) had the lower maximum axial pull-out force as compared with the 4-hole group (217.29 ± 49.68 N), 6-hole group (228.39 ± 57.83 N), and straight pore group (237.55 ± 35.96 N) (P < 0.01). Bone cement was mainly distributed in 1/3 of the distal end of the screw among the 4-hole group, in the middle 1/3 and distal end of the screw among the 6-hole group, in the proximal 1/3 of the screw among the 8-hole group, and along the long axis of the whole screw body in the straight pore group. It might indicate that the 8-hole and straight-hole groups were more vulnerable to spinal canal cement leakage. After pullout, bone cement was also closely connected with the screw without any looseness or fragmentation. CONCLUSIONS: The bone cement injectors with different number of holes can be used to augment the pedicle screw channel. The pedicle screw augmented by the 4-hole or 6-hole sheath may have similar effects to the straight pore injector. However, the 8-hole injector may result in relatively lower pull-out strength and the straight pore injector has the risks of cement leakage as well as cement solidarization near the screw head.


Asunto(s)
Tornillos Pediculares , Anciano , Fenómenos Biomecánicos , Cementos para Huesos/efectos adversos , China , Humanos , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/cirugía , Polimetil Metacrilato
16.
Acta Virol ; 66(1): 27-38, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35380863

RESUMEN

Enteroviruses had diverged into many types, some of which cause hand, foot and mouth disease (HFMD) in children. The predominant enterovirus types associated with HFMD are EVA71, CVA16, CVA6 and CVA10. Four enterovirus types were classified into subtypes based on VP1 sequences. However, the phylogenetics of these enteroviruses is rarely concerned at the genomic level. In this study, we performed the phylogenetic analyses of the EVA71, CVA16, CVA6 and CVA10 using available full-length genomic sequences. We found that the topologies of phylogenetic trees of full-length genomic sequences and VP1 sequences were almost consistent, except few subtypes of EVA71 and CVA10. The mean genetic divergence was 15.8-27% between subtypes and less than 12% within subtypes/sub-subtypes at genomic level. Comparison of phylogenetic topologies between genomic and VP1 sequences helped us to identify two new EVA71 inter-subtype recombinants RF01_CC4 and RF02_CC4. Furthermore, EVA71 subtypes C1 and C2 and CVA10 subtype D were found to originate through inter-subtype recombination. The genomic reference sequences of these enteroviruses are provided here for subtyping. The results provide important insights into the understanding of the evolution and epidemiology of the four enteroviruses. Keywords: enterovirus; hand; foot and mouth disease; classification; genetic distance; recombination.


Asunto(s)
Infecciones por Enterovirus , Enterovirus , Fiebre Aftosa , Enfermedad de Boca, Mano y Pie , Animales , Niño , China/epidemiología , Enterovirus/genética , Enfermedad de Boca, Mano y Pie/epidemiología , Humanos , Filogenia
17.
Int J Mol Sci ; 22(21)2021 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-34769395

RESUMEN

This article describes the successful synthesis of a novel nanocomposite of superparamagnetic multi-walled nanotubes with a four-arm polyethylene glycol amine polymer (mMWCNTs@4-arm-PEG-NH2). This composite was then employed as a support for the covalent co-immobilization of Rhizopus oryzae and Candida rugosa lipases under appropriate conditions. The co-immobilized lipases (CIL-mMWCNTs@4-arm-PEG-NH2) exhibited maximum specific activity of 99.626U/mg protein, which was 34.5-fold superior to that of free ROL, and its thermal stability was greatly improved. Most significantly, CIL-mMWCNTs@4-arm-PEG-NH2 was used to prepare biodiesel from waste cooking oil under ultrasound conditions, and within 120 min, the biodiesel conversion rate reached 97.64%. This was due to the synergy effect between ROL and CRL and the ultrasound-assisted enzymatic process, resulting in an increased biodiesel yield in a short reaction time. Moreover, after ten reuse cycles, the co-immobilized lipases still retained a biodiesel yield of over 78.55%, exhibiting excellent operational stability that is attractive for practical applications. Consequently, the combined use of a novel designed carrier, the co-immobilized lipases with synergy effect, and the ultrasound-assisted enzymatic reaction exhibited potential prospects for future applications in biodiesel production and various industrial applications.


Asunto(s)
Aminas/química , Biocombustibles/análisis , Enzimas Inmovilizadas/metabolismo , Lipasa/metabolismo , Nanopartículas de Magnetita/química , Nanocompuestos/química , Polietilenglicoles/química , Candida/enzimología , Enzimas Inmovilizadas/química , Esterificación , Lipasa/química , Rhizopus oryzae/enzimología
18.
Bull Environ Contam Toxicol ; 107(4): 597-601, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32417953

RESUMEN

Being immersed in seawater for a few days, microorganisms will adhere to the surface of different materials and form biofilms. After being immersed in seawater for 1 week, high-throughput sequencing method was used to analyze the bacterial community structure of the biofilms on the surface of microbeads with different materials including steel, SiO2, and polyvinyl chloride (PVC). Operational taxonomic unit clustering results showed that some differences existed in the bacterial communities attached to the surface of different microbeads. Each microbead made by different material had its unique bacterial community. The heatmap indicated that the dominant genera on the surface of different microbeads were different from each other. Quantitative analysis showed that the relative abundance of dominant genera were different among different types of microbeads. Beta diversity analysis and principal component analysis showed that difference in the bacterial community on surface of steel-bead and PVC-bead was the most significant.


Asunto(s)
Microplásticos , Plásticos , Biopelículas , Dióxido de Silicio , Agua
19.
Ecotoxicol Environ Saf ; 187: 109852, 2020 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-31670243

RESUMEN

Microplastics have become emerging pollutants and served as potential vectors for harmful bacteria, while rare information on the emergency and propagation of antibiotic resistant bacteria (ARB) and antibiotic resistance genes (ARGs) on the surface of microplastics is available. This study investigated the enrichment of ARB, especially multi-antibiotic resistant bacteria (MARB), on the surface of microplastics in mariculture system. Polyethylene terephthalate accounted for the highest proportion (75%) in the collected microplastics. The counts of cultivable ARB in microplastic samples were 6.40 × 106-2.48 × 108 cfu/g, which were 100-5000 times higher than those in water samples. The ratios of cultivable ARB to total cultivable bacteria from microplastic samples were higher than those from water samples. High-throughput sequencing showed that the diversity and abundance of cultivable ARB in the microplastic samples was high with the predominant bacterial genera of Vibrio, Muricauda and Ruegeria. Total 160 MARB isolates were obtained and most of isolates were obtained from the microplastic samples. MARB isolates resisting or intermediating to four and three antibiotics accounted for much higher proportions in the microplastic samples, and the higher percentage of antibiotic resistance was to penicillin, sulfafurazole, erythromycin and tetracycline. The dominant multiple antibiotic resistance profile was TET-SFX-ERY-PEN, which accounted for 25.4% in microplastic samples and 23.9% in water samples. In typical MARB isolates, the positive detection rate of ARGs was up to 80.0% in microplastic samples while that was 65.3% in water samples. Five types of class 1 integrons (intI1) associated gene cassette arrays and seven types of gene cassettes were detected in microplastic samples, which were more than those in water samples. These results revealed that microplastics were hazardous pollutants for the enrichment of ARB, especially superbugs, and the spread of antibiotic resistance.


Asunto(s)
Farmacorresistencia Microbiana/genética , Genes Bacterianos , Bacterias Gramnegativas/crecimiento & desarrollo , Microplásticos/toxicidad , Rhodobacteraceae/crecimiento & desarrollo , Contaminantes Químicos del Agua/toxicidad , Antibacterianos/farmacología , Bacterias Gramnegativas/genética , Integrones/genética , Microplásticos/química , Rhodobacteraceae/genética , Propiedades de Superficie , Contaminantes Químicos del Agua/química
20.
Anal Chem ; 90(3): 2186-2192, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29283250

RESUMEN

Western-blot (WB) is a powerful analytical technique for protein identification in complex biological samples and has been widely used in biological studies for decades. Detection specificity and sensitivity of WB largely relies on quality of the antibodies and performance of the conjugated HRP. However, the application of WB analysis for the detection of protein post-translational modifications (PTMs) is hampered by the low abundance of protein PTMs and by the limited availability of antibodies that specifically differentiate various kinds of PTMs from their protein substrates. Therefore, new recognition mechanisms and signal amplification strategies for WB analysis of protein PTMs is in high demand. In this work, we prepared a soluble polymer that detects various azide-tagged PTM proteins in WB analysis using triarylphosphine and HRP modified thermoresponsive polymer. Specific and efficient detection of azide-tagged PTM protein is achieved via the bioorthogonal reaction between azide and triarylphosphine. More importantly, the chemiluminiscent signal in the WB analysis is largely amplified by the temperature induced self-assembly of numerous thermoresponsive polymer chains carrying multiple HRPs. As a result, approximately 100 times more sensitive detection than commercial antibodies is achieved by this method using standard PTM proteins. Though, this new reagent does not directly detect native PTMs in cell, tissue or blood samples, it still has important application potential in protein PTM studies, considering the wide availability of azide-tagging techniques to a variety of PTMs.


Asunto(s)
Acrilamidas/química , Azidas/química , Western Blotting/métodos , Polímeros/química , Procesamiento Proteico-Postraduccional , Proteínas/análisis , Acrilamidas/síntesis química , Acilación , Glucosamina/metabolismo , Glicosilación , Células HeLa , Peroxidasa de Rábano Silvestre/química , Humanos , Fosfinas/química , Polímeros/síntesis química , Proteínas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA