Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Hazard Mater ; 470: 134165, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38574660

RESUMEN

It has been reported that N-(1,3-dimethylbutyl)-N'-phenyl-p-phenylenediamine-quinone (6PPD-Q), a derivative of the tire antioxidant, N-(1,3-dimethylbutyl)-N'-phenyl-p-phenylenediamine (6PPD), exhibits acute toxicity towards organisms. However, the possible reproductive toxicity of 6PPD-Q in mammals has rarely been reported. In this study, the effects of 6PPD-Q on the reproductive toxicity of C57Bl/6 male mice were assessed after exposure to 6PPD-Q for 40 days at 4 mg/kg body weight (bw). Exposure to 6PPD-Q not only led to a decrease in testosterone levels but also adversely affected semen quality and in vitro fertilization (IVF) outcomes, thereby indicating impaired male fertility resulting from 6PPD-Q exposure. Additionally, transcriptomic and metabolomic analyses revealed that 6PPD-Q elicited differential expression of genes and metabolites primarily enriched in spermatogenesis, apoptosis, arginine biosynthesis, and sphingolipid metabolism in the testes of mice. In conclusion, our study reveals the toxicity of 6PPD-Q on the reproductive capacity concerning baseline endocrine disorders, sperm quality, germ cell apoptosis, and the sphingolipid signaling pathway in mice. These findings contribute to an enhanced understanding of the health hazards posed by 6PPD-Q to mammals, thereby facilitating the development of more robust safety regulations governing the utilization and disposal of rubber products.


Asunto(s)
Ratones Endogámicos C57BL , Espermatozoides , Testosterona , Animales , Masculino , Espermatozoides/efectos de los fármacos , Testosterona/sangre , Testículo/efectos de los fármacos , Testículo/metabolismo , Testículo/patología , Fenilendiaminas/toxicidad , Goma/toxicidad , Apoptosis/efectos de los fármacos , Espermatogénesis/efectos de los fármacos , Ratones , Reproducción/efectos de los fármacos , Análisis de Semen
2.
Zhonghua Xin Xue Guan Bing Za Zhi ; 38(10): 886-90, 2010 Oct.
Artículo en Zh | MEDLINE | ID: mdl-21176630

RESUMEN

OBJECTIVE: This prospective random control study was performed to compare the efficacy and safety of primary percutaneous coronary intervention (PCI) with biodegradable polymer (Excel) and with durable polymer (Cypher Select) sirolimus-eluting stents in patients with acute ST-elevation myocardial infarction (STEMI). METHODS: Consecutive patients with STEMI underwent primary PCI were randomly divided into Cypher group (n = 113) and Excel group (n = 115). The primary endpoints were major adverse cardiac events (MACE, including death, reinfarction and target vessel revascularization) within 12 months. The second endpoints included late luminal loss and restenosis at 9 months. RESULTS: Angiographic follow-up data at 9 months were available in 43 (38%) patients in Cypher group and 48 (42%) in Excel group. The rates of in-stent restenosis and in-segment restenosis were 2.3% vs. 2.1% (P = 0.937) and 4.7% vs. 6.3% (P = 0.738), respectively. The late luminal loss of in-stent and in-segment were (0.17 ± 0.26) mm vs. (0.18 ± 0.33) mm (P = 0.483) and (0.19 ± 0.36) mm vs. (0.20 ± 0.42) mm (P = 0.419), respectively. There were no significant differences in death (3.5% vs. 2.6%, P = 0.692), reinfarction (1.8% vs. 2.6%, P = 0.658), target vessel revascularization (1.8% vs. 2.6%, P = 0.658), MACE (5.3% vs. 6.1%, P = 0.788) or stent thrombosis (4.4% vs. 3.5%, P = 0.692) at 12 months between Cyper group and Excel group. CONCLUSIONS: Excel and Cypher Select stents may have similar mid-term efficacy and safety in patients with STEMI treated with primary PCI.Further investigation is warranted to validate the long-term efficacy and safety.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Stents Liberadores de Fármacos , Infarto del Miocardio/terapia , Sirolimus/administración & dosificación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polímeros/química , Estudios Prospectivos , Sirolimus/uso terapéutico , Resultado del Tratamiento
3.
JACC Cardiovasc Interv ; 11(23): 2368-2377, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30522665

RESUMEN

OBJECTIVES: The aim of the present study was to evaluate the angiographic efficacy, clinical safety, and effectiveness of the Restore paclitaxel-coated balloon in a randomized trial designed to enable the approval of the new device in China. BACKGROUND: Drug-coated balloon (DCB) angioplasty offers an effective treatment for in-stent restenosis. Restore is a new DCB with a SAFEPAX shellac-ammonium salt excipient that can avoid drug washing off during catheter delivery to the target lesion site. METHODS: In the noninferiority RESTORE ISR China (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis) trial, eligible patients with first occurrence of drug-eluting stent ISR were randomized to the Restore DCB or SeQuent Please DCB in a 1:1 ratio stratified by diabetes. Angiographic and clinical follow-up was planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment late loss. RESULTS: Between May 2016 and July 2017, a total of 240 subjects at 12 sites were randomized to either the Restore group (n = 120) or the SeQuent Please group (n = 120). Nine-month in-segment late loss was 0.38 ± 0.50 mm with Restore versus 0.35 ± 0.47 mm with SeQuent Please; the 1-sided 97.5% upper confidence limit of the difference was 0.17 mm, achieving noninferiority of Restore compared with SeQuent Please (p for noninferiority = 0.02). Both DCBs had similar 1-year rates of target lesion failure (13.3% vs. 12.6%; p = 0.87). CONCLUSIONS: In this head-to-head randomized trial, the Restore DCB was noninferior to the SeQuent Please DCB for the primary endpoint of 9-month in-segment late loss. (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis; NCT02944890).


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Catéteres Cardíacos , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos , Paclitaxel/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , China , Constricción Patológica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Paclitaxel/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
Chin Med J (Engl) ; 127(14): 2561-6, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25043067

RESUMEN

BACKGROUND: Drug-eluting stents (DES) with durable polymer have significantly reduced restenosis and target vessel revascularization compared with bare metal stents. Durable polymer has been linked with persistent inflammation of vessel wall and delayed endothelial healing that may increase the risk of late and very late stent thrombosis. This study sought to evaluate the efficacy and safety of HELIOS completed biodegradable polymer sirolimus-eluting stent (SES) in de novo coronary lesions. METHODS: Totally, 287 patients with one or two de novo coronary lesions (lesion length ≤ 38 mm and reference vessel diameter 2.5-4.0 mm) were enrolled in the HOPE study, a prospective, multicenter, randomized, non-inferiority trial. Patients were randomized to treatment either with HELIOS completed biodegradable polymer SES (n = 142) or PARTNER durable polymer SES (n = 145). The primary endpoint was angiographic in-stent late lumen loss (LLL) at 9-month follow-up. The secondary endpoint included stent thrombosis and major adverse cardiac events including cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR). RESULTS: The 9-month in-stent LLL in the HELIOS group was similar to the PARTNER group, (0.16 ± 0.22) mm vs. (0.19 ± 0.30) mm (P = 0.28). The difference and 95% confidence interval were -0.03 (-0.09, 0.04), and the P value for non-inferiority <0.01. Major adverse cardiovascular event (MACE) occurred in 7.9% vs. 8.2%, MI in 2.4% vs. 3.0%, TLR in 5.5% vs. 3.0%, and stent thrombosis in 0 vs. 1.5%; and events were comparable between the HELIOS group and PARTNER group at three-year follow-up (all P > 0.05). The three-year cardiac death was lower in the HELIOS group, but with no significant difference, 0 vs. 3.0% (P = 0.12). CONCLUSIONS: In the HOPE trial, the novel completed biodegradable polymer SES HELIOS was non-inferior to the durable polymer SES PARTNER with respect to nine-month in-stent LLL in de novo coronary lesions. The incidence of other clinical endpoints was low for both of the stents in three-year follow-up.


Asunto(s)
Stents Liberadores de Fármacos , Polímeros/química , Polímeros/uso terapéutico , Sirolimus/uso terapéutico , Adulto , Anciano , Angiografía , Enfermedad de la Arteria Coronaria/cirugía , Reestenosis Coronaria/prevención & control , Humanos , Persona de Mediana Edad , Intervención Coronaria Percutánea , Titanio/química , Resultado del Tratamiento , Adulto Joven
5.
EuroIntervention ; 8(7): 796-802, 2012 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-23171800

RESUMEN

AIMS: This study sought to evaluate the safety and efficacy of the NOYA stent which is a cobalt chromium-based sirolimus-eluting stent (SES) with DL-polylactide biodegradable polymer (Medfavour Medical, Beijing, China) in treating de novo coronary artery lesions. METHODS AND RESULTS: The NOYA I trial was designed to compare the NOYA stent with the FIREBIRD2™ stent, a durable polymer SES widely used in China (MicroPort Medical, Shanghai, China); the trial was a non-inferiority trial with a primary angiographic endpoint of the in-stent late lumen loss (LLL) at nine-month follow-up. The secondary endpoints were binary restenosis rates within nine months, major adverse cardiac events (MACE) defined as the composite of cardiac death, myocardial infarction (MI) or target lesion revascularisation (TLR), and definite/probable stent thrombosis (ST) at 24-month follow-up. A total of 300 patients (n=150 in each group) were enrolled in the study from 16 Chinese centres. The LLL in the NOYA group at nine-month follow-up was similar to the FIREBIRD2 group (0.11±0.18 mm vs. 0.14±0.23 mm, p=0.16; non-inferiority p<0.001). The rates of MACE, death, MI and TLR at 24-month follow-up were comparable between these two devices (p>0.05, respectively). CONCLUSIONS: The biodegradable polymer NOYA stent was non-inferior to the FIREBIRD2 durable polymer stent with respect to the primary non-inferiority endpoint of in-stent LLL at nine-month follow-up. Clinical outcomes at 24-month follow-up were comparable between the two stents. (ClinicalTrials.gov number, NCT01226355).


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Poliésteres , Sirolimus/administración & dosificación , Anciano , Análisis de Varianza , Distribución de Chi-Cuadrado , China , Aleaciones de Cromo , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
6.
Chin Med J (Engl) ; 124(6): 811-6, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21518585

RESUMEN

BACKGROUND: Available drug-eluting stents (DES) have achieved great success in reducing restenosis rates. Recently, investigators have demonstrated that the durable polymer carrier plays a significant role in DES-related hypersensitive reaction and delays vessel healing. TIVOLI stent is a novel sirolimus-eluting coronary stent with biodegradable coating containing sirolimus and polylactic-co-glycolic acid (PLGA) polymer. The present study sought to evaluate the effectiveness and safety of the TIVOLI biodegradable-polymer-based sirolimus-eluting stent in treating patients with coronary artery disease. METHODS: A prospective, multicenter clinical trial comparing TIVOLI biodegradable coated sirolimus-eluting stent with ENDEAVOR zotarolimus-eluting stent was conducted in 324 patients (TIVOLI group: 168 patients; ENDEAVOR group: 156 patients) at 12 centers in China to demonstrate the non-inferiority of in-stent late loss with TIVOLI stent compared to ENDEAVOR stent in subjects with a maximum of two de novo native coronary artery lesions (lesion length ≤ 40 mm, reference vessel diameter 2.25-4.00 mm). The primary end point was angiographic in-stent late loss at 8-month. The secondary end points were clinical outcomes at 2 years, including major adverse cardiac events (cardiac death, myocardial infarction, or target-lesion revascularization) and stent thrombosis. RESULTS: Angiographic late lumen loss at 8 months in the TIVOLI group was superior to the ENDEAVOR group (in-stent (0.25 ± 0.33) mm vs. (0.57 ± 0.55) mm, diff (95%CI) -0.23 (-0.32, -0.14), P < 0.0001; in-segment (0.25 ± 0.33) mm vs. (0.42 ± 0.55) mm, diff (95%CI) -0.13 (-0.23, -0.02), P = 0.0083). The rate of in-stent binary restenosis at 8 months was reduced from 8.6% in the ENDEAVOR group to 2.9% in the TIVOLI group (P = 0.0229). Compared to ENDEAVOR stent, TIVOLI stent resulted in a significant reduction in target-lesion revascularization (4.2% vs. 9.6%, P = 0.0495) at 2 years. The two-year major adverse cardiac events (MACE) rate was lower for the TIVOLI group, but not significantly different (6.6% vs. 10.9%, P = 0.1630). CONCLUSIONS: TIVOLI was superior to ENDEAVOR stent with respect to late lumen loss at 8 months, and it yielded both lower rates of angiographic binary restenosis at 8 months and target lesion revascularization (TLR) at 2 years. The MACE rate at 2 years was comparable in both groups.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/tratamiento farmacológico , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Inmunosupresores/uso terapéutico , Sirolimus/análogos & derivados , Sirolimus/uso terapéutico , Anciano , Angiografía Coronaria , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polímeros/química , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA