Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Biomacromolecules ; 19(1): 53-61, 2018 01 08.
Artículo en Inglés | MEDLINE | ID: mdl-29172451

RESUMEN

A novel zwitterionic polymer ionic liquid functionalized magnetic nanospheres, shortly as Fe3O4@PCL-PILs, is synthesized by grafting ionic liquid VimCOOHBr onto polymer ε-caprolactone (PCL) modified magnetic nanospheres via esterification and surface-initiated free radical polymerization. This established synthesis strategy offers the obtained magnetic nanospheres with well-defined core-corona structure, compact grafting layer, favorable zwitterionic and negative-charged surface, and high magnetic susceptibility. The as-prepared Fe3O4@PCL-PILs nanospheres exhibit typical "zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC)" behaviors toward protein binding, and selectively adsorption of glycoprotein is achieved. The adsorption capacity of the magnetic nanospheres toward Immunoglobulin G is high up to 1136.4 mg g-1, and the captured Immunoglobulin G could be efficiently recovered by using 0.5% NH3 H2O (v/v) as stripping reagent, providing a recovery of 80.5%. Fe3O4@PCL-PILs nanospheres are then employed as sorbent for the selective isolation of Immunoglobulin G from human whole blood, obtaining high-purity Immunoglobulin G as demonstrated by polyacrylamide gel electrophoresis assays.


Asunto(s)
Óxido Ferrosoférrico/química , Glicoproteínas/aislamiento & purificación , Líquidos Iónicos/química , Nanopartículas de Magnetita/química , Nanosferas/química , Poliésteres/química , Adsorción , Cromatografía Liquida/métodos , Electroforesis en Gel de Poliacrilamida , Esterificación , Glicoproteínas/química , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina G/aislamiento & purificación , Inmunoglobulina G/metabolismo , Microscopía Electrónica de Transmisión , Espectrometría por Rayos X , Difracción de Rayos X
2.
Ying Yong Sheng Tai Xue Bao ; 34(4): 1083-1090, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37078328

RESUMEN

Green space is a kind of resource welfare. The evaluation of green space equity based on green view index (GVI) is important to ensure the equitable distribution of green resources. Taking the central urban area of Wuhan as the research object, based on multi-source data such as Baidu Street View Map, Baidu Thermal Map, and satellite remote sensing images, we evaluated the equity of spatial distribution of GVI in Wuhan by using the locational entropy, Gini coefficient and Lorenz curve. The results showed that 87.6% of the points in the central urban area of Wuhan were below the level of poor green vision, which mainly concentrated in Wuhan Iron and Steel Industrial Base of Qingshan District and south of Yandong Lake. The number of points reaching an excellent level was the least (0.4%), mainly concentrated around the East Lake. The overall Gini coefficient of GVI in the central urban area of Wuhan was 0.49, which indicated that the distribution of GVI was heterogeneous. The Gini coefficient of Hongshan District was the largest at 0.64, indicating a huge gap in the distribution of GVI, while the Gini coefficient of Jianghan District was the smallest at 0.47, with a large gap in the distribution. The central urban area of Wuhan had the most low-entropy areas for 29.7% and the least high-entropy areas for 15.4%. There were two-level differences in entropy distribution within Hongshan District, Qingshan District, and Wuchang District. The nature of land use and the role of linear greenery were the main factors affecting the equity of green space in the study area. Our results could provide theoretical basis and planning reference for optimizing urban green space layout.


Asunto(s)
Industrias , Parques Recreativos , Ciudades , Lagos , Acero
3.
Shanghai Kou Qiang Yi Xue ; 32(4): 405-409, 2023 Aug.
Artículo en Zh | MEDLINE | ID: mdl-38044736

RESUMEN

PURPOSE: To investigate the effect of 4 kinds of prosthodontic materials on masticatory and gingival function. METHODS: A total of 167 patients with dental defects who underwent prosthodontic treatment from October 2019 to January 2022 were collected. They were randomly divided into 4 groups with 41 cases in the pure titanium group, 40 cases in the cobalt-chromium alloy group, 43 cases in the nickel-chromium alloy group and 43 cases in the zirconium dioxide group. The curative effect and satisfaction degree after 6 months of treatment in 4 groups were recorded and compared. The masticatory function (chewing efficiency, bite force), gingival function[plaque index(PLI), gingival index(GI) and sulcus bleeding index(SBI)], gingival crevicular fluid inflammation-related indicators[tumor necrosis factor alpha(TNF-α), interleukin-6(IL-6), aspartate aminotransferase(AST) and alkaline phosphatase (alkaline phosphatase, ALP)] before and after treatment were measured and compared in 4 groups. Statistical analysis was performed with SPSS 20.0 software package. RESULTS: There was no significant difference in curative effect in 4 groups(P>0.05). Before and after treatment, there was no significant difference in mastication efficiency and bite force in 4 groups(P>0.05). Before treatment, there was no significant difference in PLI, GI, SBI, gingival crevicular fluid weight, TNF-α, IL-6, AST and ALP in gingival crevicular fluid in 4 groups(P>0.05). Compared with before treatment, PLI, GI and SBI in 4 groups were decreased after treatment (P<0.05), and the decrease was in the order of cobalt-chromium alloy group≈nickel-chromium alloy group<pure titanium group<zirconia dioxide group. Before treatment, there was no significant difference in the weight of gingival crevicular fluid, TNF-α, IL-6, AST and ALP in gingival crevicular fluid in 4 groups(P>0.05). The crevicular fluid weight, TNF-α, IL-6, AST and ALP in gingival crevicular fluid were significantly increased(P<0.05), and the increase was in the order of zirconia group<pure titanium group<cobalt-chromium alloy group≈nickel-chromium alloy group. There was no significant difference in restoration integrity and color satisfaction in 4 groups(P>0.05), but there was significant difference in marginal fitness and sensitivity satisfaction in 4 groups(P<0.05). CONCLUSIONS: Pure titanium, cobalt-chromium alloy, nickel-chromium alloy and zirconium dioxide can be used for the treatment of dentition defects, and they all can obtain satisfactory chewing function. In addition, zirconium dioxide restoration has the effect of improving gingival function and inflammation-related indicators of gingival crevicular fluid with a broader application prospect.


Asunto(s)
Interleucina-6 , Factor de Necrosis Tumoral alfa , Humanos , Fosfatasa Alcalina , Prostodoncia , Titanio , Líquido del Surco Gingival , Aleaciones de Cromo , Inflamación
4.
Zhonghua Fu Chan Ke Za Zhi ; 47(7): 487-91, 2012 Jul.
Artículo en Zh | MEDLINE | ID: mdl-23141156

RESUMEN

OBJECTIVE: To evaluate the therapeutic effect and influence factors of silicone pessary in treatment of pelvic organ prolapse (POP). METHODS: From October 2005 to October 2010, 132 with symptomatic POP managed by pessary were enrolled in this retrospective study. Validated prolapse quality of life questionnaire (pelvic floor distress inventory short form 20, PFDI-20), pelvic floor impact questionnaire short form 7 (PFIQ-7) and the patients' satisfaction degree were used to evaluate the therapeutic effect. Clinical characteristic of the patients with successful using for more than 6 months (successful fitting group), giving up within 6 months (giving up group), unsuccessful fitting (unsuccessful fitting group) were compared. Factors influencing satisfaction degree and causing discontinuation were investigated. RESULTS: One hundred and six among 132 (106/132, 80.3%) patients were in successful fitting group, 26 (26/132, 19.7%) patients were in the unsuccessful fitting group. In the successful fitting group, 86.8% (92/106) patients were followed up, the median follow-up time was 12.5 months. And 78.3% (72/92) patients continued to use pessary with the wearing time ranged 3 - 69 months; 21.7% (20/92) patients discontinued with the wearing time ranged 1 - 38 month, 14 patients (14/20) gave up in the initial 6 months. The median scores of PFDI-20 and PFIQ-7 questionnaires before pessary use were 50.0 and 47.6, which decreased to 8.9 and 0.0 after pessary use (P < 0.05). And 87.1% (61/70) patients were satisfied. There was no significantly difference among 3 groups on clinical characteristics, such as age, body mass index (BMI), pelvic surgery and so on (P > 0.05). The main factor influencing satisfaction degree and causing discontinuation was difficulties in placing and removing. CONCLUSIONS: Silicone pessary is effective for patients with POP. It could relieve discomfort symptoms and improve quality of life. The main factor influencing pessary use is difficulties in placing and removing. Thus, More suggestions are needed for patients in the initial 6 months.


Asunto(s)
Prolapso de Órgano Pélvico/terapia , Pesarios , Calidad de Vida , Anciano , Femenino , Humanos , Persona de Mediana Edad , Satisfacción del Paciente , Prolapso de Órgano Pélvico/patología , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Siliconas , Encuestas y Cuestionarios , Resultado del Tratamiento , Incontinencia Urinaria/etiología , Prolapso Uterino/terapia , Vagina/anatomía & histología , Vagina/patología , Excreción Vaginal/etiología
5.
Shanghai Kou Qiang Yi Xue ; 29(6): 591-595, 2020 Dec.
Artículo en Zh | MEDLINE | ID: mdl-33778824

RESUMEN

PURPOSE: To investigate the effects of different surface treatments and adhesive self-etch functional monomers on the immediate repair bond strength and integrity of the repaired resin composite interface. METHODS: Ninety-eight resin composite blocks made of a nanohybrid resin composite were randomly divided into seven groups, each with 14 blocks, including positive control group: non-conditioned surface, Group A1: Gluma Comfort Bond, Group A2: Gluma Comfort Bond and sandblasting, Group B1: Tokuyama Bond Force IITM adhesive system, Group B2: Tokuyama Bond Force IITM adhesive system and sandblasting, Group C: polishing, and Group D: sandblasting. Resin composite identical to the substrate was applied and the repaired specimens were subjected to shear bond strength (SBS) testing. Representative samples from all groups received scanning electron microscopy and surface profilometry to determine their mode of failure. The data were processed with SPSS 20.0 software package. RESULTS: SBS of Group D was significantly higher than that of positive control group (P<0.05). SBS of Group A1, A2, B1 and B2 was significantly higher than that of Group C and D (P<0.05). Comparison of SBS among Group B1, D and A1 showed no significant difference(P>0.05). SBS between Group B2 and positive control group had no significant difference(P>0.05). Except specimens with sandblasting and the use of TBF II system, SBS of positive control group was significantly higher than that of Group A1 and C(P<0.05). The polished specimens had significantly more adhesive failures than those with sandblasted surfaces (P<0.05). Specimens treated with polishing and Gluma Comfort Bond showed significantly more adhesive failures than those treated with polishing and TBF II system (P<0.05). The sandblasted surfaces conditioned with TBF II showed significantly more cohesive failures than those treated with polishing and TBF II (P<0.05). The sandblasted specimens provided significantly more irregular and rougher surface finish than the polishing technique (P<0.05). CONCLUSIONS: Sandblasting of the composite substrate and the use of TBF II adhesive system shows the highest repair bond strength, higher adhesive interfacial failures and fewer cohesive failures; however, it is noteworthy that the composite substrate types yield statistically higher food residue rate, which results in poor oral hygiene maintenance. Therefore, the application of this repair protocol should match up with correct oral health behaviors.


Asunto(s)
Recubrimiento Dental Adhesivo , Resinas Compuestas , Análisis del Estrés Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Cementos de Resina , Resistencia al Corte , Propiedades de Superficie
6.
RSC Adv ; 10(23): 13700-13707, 2020 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-35493011

RESUMEN

"Calcium hydroxide [Ca(OH)2]" is a medicament frequently used for antimicrobial purposes in endodontic procedures, or it is used as a toxic-waste adsorbent in industry. Ca(OH)2 particles produced through conventional methods are size untunable and have a wide size distribution and polygonal shape. In this paper, a novel and facile approach involving template-mediated synthesis and two-step ion exchange is proposed for uniform size Ca(OH)2 composite particles generation. "Sodium-alginate (Na-alginate)" was used as a precursor, and monodisperse Na-alginate emulsions were formed through needle droplet or droplet microfluidic technology. After the first ion exchange step with the Ca2+ ions, "calcium-alginate (Ca-alginate)" particles were obtained. The Ca-alginate particles were intermediate reaction products and were designed to be the templates for ensuring the spherical shape and size of products. The OH- ions were used for the second ion exchange step to fabricate Ca(OH)2 composite particles. The results revealed that the Ca(OH)2 composite particles were size tunable, had a spherical shape, and were monodisperse (with a relative standard deviation of less than 8%). The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay revealed that the Ca(OH)2 composite particles were potential biocompatible materials.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA