Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Proc Natl Acad Sci U S A ; 119(33): e2203287119, 2022 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-35939711

RESUMEN

Electrical neuron stimulation holds promise for treating chronic neurological disorders, including spinal cord injury, epilepsy, and Parkinson's disease. The implementation of ultrathin, flexible electrodes that can offer noninvasive attachment to soft neural tissues is a breakthrough for timely, continuous, programable, and spatial stimulations. With strict flexibility requirements in neural implanted stimulations, the use of conventional thick and bulky packages is no longer applicable, posing major technical issues such as short device lifetime and long-term stability. We introduce herein a concept of long-lived flexible neural electrodes using silicon carbide (SiC) nanomembranes as a faradic interface and thermal oxide thin films as an electrical barrier layer. The SiC nanomembranes were developed using a chemical vapor deposition (CVD) process at the wafer level, and thermal oxide was grown using a high-quality wet oxidation technique. The proposed material developments are highly scalable and compatible with MEMS technologies, facilitating the mass production of long-lived implanted bioelectrodes. Our experimental results showed excellent stability of the SiC/silicon dioxide (SiO2) bioelectronic system that can potentially last for several decades with well-maintained electronic properties in biofluid environments. We demonstrated the capability of the proposed material system for peripheral nerve stimulation in an animal model, showing muscle contraction responses comparable to those of a standard non-implanted nerve stimulation device. The design concept, scalable fabrication approach, and multimodal functionalities of SiC/SiO2 flexible electronics offer an exciting possibility for fundamental neuroscience studies, as well as for neural stimulation-based therapies.


Asunto(s)
Terapia por Estimulación Eléctrica , Neuroestimuladores Implantables , Nanoestructuras , Semiconductores , Compuestos Inorgánicos de Carbono/química , Terapia por Estimulación Eléctrica/instrumentación , Membranas Artificiales , Compuestos de Silicona/química , Dióxido de Silicio/química
2.
Electrophoresis ; 42(21-22): 2230-2237, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34396540

RESUMEN

Microfluidic particle focusing has been a vital prerequisite step in sample preparation for downstream particle separation, counting, detection, or analysis, and has attracted broad applications in biomedical and chemical areas. Besides all the active and passive focusing methods in Newtonian fluids, particle focusing in viscoelastic fluids has been attracting increasing interest because of its advantages induced by intrinsic fluid property. However, to achieve a well-defined focusing position, there is a need to extend channel lengths when focusing micrometer-sized or sub-microsized particles, which would result in the size increase of the microfluidic devices. This work investigated the sheathless viscoelastic focusing of particles and cells in a zigzag microfluidic channel. Benefit from the zigzag structure of the channel, the channel length and the footprint of the device can be reduced without sacrificing the focusing performance. In this work, the viscoelastic focusing, including the focusing of 10 µm polystyrene particles, 5 µm polystyrene particles, 5 µm magnetic particles, white blood cells (WBCs), red blood cells (RBCs), and cancer cells, were all demonstrated. Moreover, magnetophoretic separation of magnetic and nonmagnetic particles after viscoelastic pre-focusing was shown. This focusing technique has the potential to be used in a range of biomedical applications.


Asunto(s)
Técnicas Analíticas Microfluídicas , Elasticidad , Eritrocitos , Dispositivos Laboratorio en un Chip , Microfluídica , Poliestirenos , Viscosidad
3.
Anal Chem ; 89(20): 11005-11013, 2017 10 17.
Artículo en Inglés | MEDLINE | ID: mdl-28892622

RESUMEN

The enzyme-mimicking activity of iron oxide based nanostructures has provided a significant advantage in developing advanced molecular sensors for biomedical and environmental applications. Herein, we introduce the horseradish peroxidase (HRP)-like activity of gold-loaded nanoporous ferric oxide nanocubes (Au-NPFe2O3NC) for the development of a molecular sensor with enhanced electrocatalytic and colorimetric (naked eye) detection of autoantibodies. The results showed that Au-NPFe2O3NC exhibits enhanced peroxidase-like activity toward the catalytic oxidation of 3,3',5,5'-tertamethylbenzidine (TMB) in the presence of H2O2 at room temperature (25 °C) and follows the typical Michaelis-Menten kinetics. The autoantibody sensor based on this intrinsic property of Au-NPFe2O3NC resulted in excellent detection sensitivity [limit of detection (LOD) = 0.08 U/mL] and reproducibility [percent relative standard deviation (% RSD) = <5% for n = 3] for analyzing p53-specific autoantibodies using electrochemical and colorimetric (naked eye) readouts. The clinical applicability of the sensor has been tested in detecting p53-specific autoantibody in plasma obtained from patients with epithelial ovarian cancer high-grade serous subtype (EOCHGS, number of samples = 2) and controls (benign, number of samples = 2). As Au-NPFe2O3NC possess high peroxidase-like activity for the oxidation of TMB in the presence of H2O2 [TMB is a common chromogenic substrate for HRP in enzyme-linked immunosorbent assays (ELISAs)], we envisage that our assay could find a wide range of application in developing ELISA-based sensing approaches in the fields of medicine (i.e., detection of other biomarkers the same as p53 autoantibody), biotechnology, and environmental sciences.


Asunto(s)
Autoanticuerpos/sangre , Materiales Biocompatibles/química , Colorimetría/métodos , Compuestos Férricos/química , Oro/química , Nanoestructuras/química , Autoanticuerpos/análisis , Materiales Biocompatibles/metabolismo , Catálisis , Técnicas Electroquímicas , Femenino , Humanos , Peróxido de Hidrógeno/química , Cinética , Límite de Detección , Nanoporos , Neoplasias Ováricas/metabolismo , Neoplasias Ováricas/patología , Oxidación-Reducción , Peroxidasas/metabolismo , Reproducibilidad de los Resultados , Proteína p53 Supresora de Tumor/inmunología
4.
ACS Appl Mater Interfaces ; 15(25): 29777-29788, 2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37318848

RESUMEN

Electrohydrodynamic atomization (EHDA) provides unparalleled control over the size and production rate of particles from solution. However, conventional methods produce highly charged particles that are not appropriate for inhalation drug delivery. We present a self-propelled EHDA system to address this challenge, a promising one-step platform for generating and delivering charge-reduced particles. Our approach uses a sharp electrode to produce ion wind, which reduces the cumulative charge in the particles and transports them to a target in front of the nozzle. We effectively controlled the morphologies of polymer products created from poly(vinylidene fluoride) (PVDF) at various concentrations. Our technique has also been proven safe for bioapplications, as evidenced by the delivery of PVDF particles onto breast cancer cells. The combination of simultaneous particle production and charge reduction, along with its direct delivery capability, makes the self-propelled EHDA a versatile technique for drug delivery applications.


Asunto(s)
Sistemas de Liberación de Medicamentos , Polivinilos , Tamaño de la Partícula
5.
Lab Chip ; 22(15): 2789-2800, 2022 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-35587546

RESUMEN

Inertial microfluidics functions solely based on the fluid dynamics at relatively high flow speed. Thus, channel geometry is the critical design parameter that contributes to the performance of the device. Four basic channel geometries (i.e., straight, expansion-contraction, spiral and serpentine) have been proposed and extensively studied. To further enhance the performance, innovative channel design through combining two or more geometries is promising. This work explores embedding periodic concave and convex obstacle microstructures in sinusoidal channels and investigates their influence on particle inertial focusing and separation. The concave obstacles could significantly enhance the Dean flow and tune the flow range for particle inertial focusing and separation. Based on this finding, we propose a cascaded device by connecting two sinusoidal channels consecutively for rare cell separation. The concave obstacles are embedded in the second channel to adapt its operational flow rates and enable the functional operation of both channels. Polystyrene beads and breast cancer cells (T47D) spiking in the blood were respectively processed by the proposed device. The results indicate an outstanding separation performance, with 3 to 4 orders of magnitude enhancement in purity for samples with a primary cancer cells ratio of 0.01% and 0.001%, respectively. Embedding microstructures as obstacles brings more flexibility to the design of inertial microfluidic devices, offering a feasible new way to combine two or more serial processing units for high-performance separation.


Asunto(s)
Técnicas Analíticas Microfluídicas , Separación Celular , Microfluídica , Poliestirenos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA