Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Interv Radiol ; 35(2): 251-258, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37866474

RESUMEN

PURPOSE: To report the outcomes of the IN-DEPT trial assessing the feasibility, preliminary safety data, and 12-month outcomes of a new drug-coated balloon (DCB) product for peripheral artery disease (PAD) in Chinese patients. MATERIALS AND METHODS: This is a prospective, multicenter, single-arm clinical trial. A total of 160 patients with superficial femoral artery (SFA) and/or proximal popliteal artery lesions were treated with a new paclitaxel-coated DCB. The preliminary effectiveness end point was 12-month primary patency. The primary safety end point was freedom from device- and procedure-related mortality over 30 days and freedom from major target limb amputation and clinically driven target lesion revascularization (CD-TLR) within 12 months after the index procedure. RESULTS: In total, 160 patients presented with 162 target lesions. A total of 139 lesions (85.8%) were treated with 1 DCB, whereas the other 23 lesions (14.2%) were treated with 2 devices. The device success rate was 100%. A total of 135 subjects reached the preliminary effectiveness end point, with a 12-month primary patency rate of 84.4%. There was no 30-day device- or procedure-related death or unplanned major target limb amputation at 12 months. Five CD-TLRs (3.1%) occurred during the 12-month follow-up period. CONCLUSIONS: Results from the IN-DEPT SFA trial showed satisfactory feasibility and safety of the new DCB over 12 months in Chinese patients with PAD and femoropopliteal de novo lesions, including both stenoses and total occlusions.


Asunto(s)
Angioplastia de Balón , Fármacos Cardiovasculares , Enfermedad Arterial Periférica , Humanos , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/patología , Estudios Prospectivos , Angioplastia de Balón/efectos adversos , Materiales Biocompatibles Revestidos , Factores de Tiempo , Fármacos Cardiovasculares/efectos adversos , Arteria Poplítea/diagnóstico por imagen , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Enfermedad Arterial Periférica/patología , Grado de Desobstrucción Vascular , Resultado del Tratamiento
2.
Ann Vasc Surg ; 93: 275-282, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36796585

RESUMEN

BACKGROUND: The purpose of this trial was to assess the safety and effectiveness of a paclitaxel-coated balloon catheter in Chinese patients with de novo or nonstented restenotic femoropopliteal atherosclerotic lesions. METHODS: BIOLUX P-IV China is a prospective, independently adjudicated, multicenter, single-arm trial conducted in China. Patients with Rutherford class 2-4 were eligible, excluded were patients in which predilation resulted in severe (≥ grade D) flow-limiting dissection or residual stenosis > 70%. Follow-up assessments were conducted at 1, 6, and 12 months. The primary safety end point was 30-day major adverse event rate and the primary effectiveness end point was primary patency at 12 months. RESULTS: We enrolled 158 patients with 158 lesions. Mean age was 67.6 ± 9.6 years, diabetes was present in 53.8% (n = 85), and previous peripheral intervention/surgeries in 17.1% (n = 27). Lesions were 4.1 ± 0.9 mm in diameter and 74 ± 50 mm long with a mean diameter stenosis of 91 ± 13%; 58.2% (n = 92) were occluded (core laboratory analysis). Device success was achieved in all patients. The rate of major adverse events was 0.6% (95% confidence interval: 0.0; 3.5) at 30 days, consisting of 1 target lesion revascularization. At 12 months, binary restenosis was present in 18.7% (n = 26) and target lesion revascularization was performed in 1.4% (n = 2, all clinically driven), resulting in a primary patency of 80.0% (95% confidence interval: 72.4, 85.8); no major target limb amputation occurred. Clinical improvement at 12 months, defined as improvement of at least 1 Rutherford class, was 95.3% (n = 130). The median walking distance per 6-minute walk test was 279 m at baseline and improved by 50 m at 30 days and by 60 m at 12 months; the visual analogue scale changed from 76.6 ± 15.6 at baseline to 80.0 ± 15.0 at 30 days and 78.6 ± 14.6 at 12 months. CONCLUSIONS: Our results confirmed the clinical effectiveness and safety of a paclitaxel-coated peripheral balloon dilatation catheter for the treatment of de novo and nonstented restenotic lesion of the superficial femoral and proximal popliteal artery in Chinese patients (NCT02912715).


Asunto(s)
Angioplastia de Balón , Aterosclerosis , Enfermedad Arterial Periférica , Humanos , Persona de Mediana Edad , Anciano , Estudios Prospectivos , Constricción Patológica/etiología , Resultado del Tratamiento , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Recuperación del Miembro , Arteria Femoral/diagnóstico por imagen , Aterosclerosis/etiología , Arteria Poplítea/diagnóstico por imagen , Paclitaxel/efectos adversos , China , Angioplastia de Balón/efectos adversos , Materiales Biocompatibles Revestidos , Catéteres , Grado de Desobstrucción Vascular
3.
Zhonghua Wai Ke Za Zhi ; 52(8): 597-601, 2014 Aug.
Artículo en Zh | MEDLINE | ID: mdl-25370760

RESUMEN

OBJECTIVE: To evaluate the value and clinical effect of peripheral aneurysms with polytetrafluoroethene (PTFE) stent graft after peripheral endovascular procedures. METHODS: From May 2012 to November 2013, 13 patients of peripheral aneurysms were treated with PTFE stent graft. There were 9 male and 4 female patients, aged from 24 to 74 years with a mean of 52 years. There were 7 aneurysms and 6 pseudoaneurysms. This stent graft was a self-expanding nitinol stent, internally covered by an ultra-thin polytetrafluoroethene (PTFE) graft. All peripheral aneurysms were repaired with the PTFE stent graft, using an entirely percutaneous approach. All patients were given clopidogrel and (or) aspirin postoperatively. Complications and reintervention rates were also examined. RESULTS: PTFE stent graft placement was successfully performed in all the 13 cases, and the instant isolation effect was quite satisfactory. During the follow-up period of 3 to 18 months, no stent graft related complications occurred in all patients except one patient with iliac arterial pseudoaneurysm, who developed pseudoaneurysms presented as a complication at puncture site. There were no other symptomatic complications with graft patience. CONCLUSION: Endovascular repair can be considered as an effective treatment strategy for peripheral aneurysms by PTFE stent graft.


Asunto(s)
Aneurisma/cirugía , Stents Liberadores de Fármacos , Procedimientos Endovasculares , Adulto , Anciano , Femenino , Fluorocarburos , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Polímeros , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA