1.
Catheter Cardiovasc Interv ; 95 Suppl 1: 648-657, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31909884

RESUMEN

OBJECTIVES: The FUTURE-I study aimed to assess preliminary safety and effectiveness with the long-term clinical and imaging follow-up for the Firesorb (MicroPort, Shanghai, China), a thinner-strut sirolimus-eluting bioresorbable scaffold (BRS). BACKGROUND: First-generation BRS has been associated with unexpected device-related adverse outcomes at long-term follow-up. METHODS: In this prospective, open-label, first-in-man study, patients with single de novo lesions in native coronary arteries were randomized 2:1 into two cohorts after successful Firesorb implantation: cohort 1 (n = 30) underwent multimodality imaging assessment at 6 and 24 months; and cohort 2 (n = 15) at 12 and 36 months. All patients underwent clinical follow-up at 1, 6, and 12 months and annually up to 5 years. RESULTS: Between January and March 2016, 45 patients were enrolled. At 3-year follow-up, one patient had experienced target lesion failure and none scaffold thrombosis. In-scaffold minimal lumen diameter decreased significantly from 6-month to 2-year (2.53 ± 0.24 mm vs. 2.27 ± 0.37 mm, p = .0003), and only numerically from 1-year to 3-year follow-up (2.48 ± 0.28 mm vs. 2.22 ± 0.13 mm, p = .08). By optical coherence tomography, neointimal strut coverage at 3-year follow-up was 99.8%, and very low rate of late scaffold discontinuity was observed, only in one patient on two cross sections with three malapposed struts. CONCLUSIONS: At 3-year follow-up of the FUTURE-I study, implantation of the thinner-strut Firesorb BRS appeared preliminary feasible and effective in the treatment of patients with noncomplex coronary lesions.


Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Fármacos Cardiovasculares/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Sirolimus/administración & dosificación , Angioplastia Coronaria con Balón/efectos adversos , Fármacos Cardiovasculares/efectos adversos , China , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/efectos adversos , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del Tratamiento , Ultrasonografía Intervencional
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA