Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Sensors (Basel) ; 24(1)2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38203135

RESUMEN

Fiber-based flexible sensors have promising application potential in human motion and healthcare monitoring, owing to their merits of being lightweight, flexible, and easy to process. Now, high-performance elastic fiber-based strain sensors with high sensitivity, a large working range, and excellent durability are in great demand. Herein, we have easily and quickly prepared a highly sensitive and durable fiber-based strain sensor by dip coating a highly stretchable polyurethane (PU) elastic fiber in an MXene/waterborne polyurethane (WPU) dispersion solution. Benefiting from the electrostatic repulsion force between the negatively charged WPU and MXene sheets in the mixed solution, very homogeneous and stable MXene/WPU dispersion was successfully obtained, and the interconnected conducting networks were correspondingly formed in a coated MXene/WPU shell layer, which makes the as-prepared strain sensor exhibit a gauge factor of over 960, a large sensing range of over 90%, and a detection limit as low as 0.5% strain. As elastic fiber and mixed solution have the same polymer constitute, and tight bonding of the MXene/WPU conductive composite on PU fibers was achieved, enabling the as-prepared strain sensor to endure over 2500 stretching-releasing cycles and thus show good durability. Full-scale human motion detection was also performed by the strain sensor, and a body posture monitoring, analysis, and correction prototype system were developed via embedding the fiber-based strain sensors into sweaters, strongly indicating great application prospects in exercise, sports, and healthcare.


Asunto(s)
Asco , Nitritos , Elementos de Transición , Dispositivos Electrónicos Vestibles , Humanos , Poliuretanos , Atención a la Salud
2.
BMC Oral Health ; 21(1): 423, 2021 08 30.
Artículo en Inglés | MEDLINE | ID: mdl-34461866

RESUMEN

BACKGROUND: The objective of this report was to highlight the importance of using a dental operating microscope (DOM) to locate supernumerary canals and diagnose variations in root canals using cone-beam computed tomographic (CBCT) images. CASE PRESENTATION: A 35-year-old Chinese female had repeated swelling in the upper right posterior maxilla for 3 months and was referred to evaluate symptomatic apical periodontitis and mesotaurodonts for upper right first permanent molar and upper right second permanent molar. Root canal therapy was proposed and conducted with the use of DOM and CBCT. CONCLUSIONS: Proper diagnosis and careful clinicoradiological examination are necessary, and it is essential to reinforce the knowledge of the rare morphology of root canals for clinicians.


Asunto(s)
Cavidad Pulpar , Raíz del Diente , Adulto , Tomografía Computarizada de Haz Cónico , Cavidad Pulpar/diagnóstico por imagen , Femenino , Humanos , Maxilar/diagnóstico por imagen , Diente Molar/diagnóstico por imagen
3.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 37(2): 155-161, 2019 Apr 01.
Artículo en Zh | MEDLINE | ID: mdl-31168981

RESUMEN

OBJECTIVE: To assess the feasibility and efficacy of simvastatin-collagen composite sponge as a novel, direct pulp capping material. METHODS: A total of 120 Sprague-Dawley rats were randomly divided into three groups: the simvastatin-collagen composite sponge group (SIM group), the collagen sponge group (CS group), and the Ca(OH)2 group (CH group). An endodontic entry cavity was prepared on the occlusion of the first molar on the left maxillary of each rat. The contralateral teeth were utilized as the normal control group. The rats were experimented after 1, 3, 7, 14, and 28 days. X-ray observations were conducted and the specimens underwent hematoxylin-eosin (HE) and Masson's Thichrome staining. Dentin bridge formations and pulpal biology reactions were evaluated histopathologically. RESULTS: X-ray results: high-density images could be observed on the pulp exposure sites in the CH group on the 28th day. In the SIM group, high-density images could be observed after 14 and 28 days, whereas in the CS group, high-density images were not observable in the exposed area. HE and Masson's Thichrome staining results: different degrees of inflammation under the cavity were detected in the three groups at different time points. The inflammatory reaction of the CS group was the most serious. The degree of the inflammatory reaction varied significantly between the SIM and the CS groups on the 14th and 28th days (P<0.01). The inflammatory reaction in the SIM group was lighter than in the CH group. There was a statistical difference between the SIM and the CH groups on the 14th day (P<0.05). During the observation period, the SIM group induced the best and fastest formation of reparative dentin. As for dentin bridge formation, a significantly higher complete bridge rate was observed in the SIM group than in the CH and in the CS groups on the 14th day (P<0.05) and for the SIM and the CH groups compared with the CS group on the 28th day (P<0.05). CONCLUSIONS: The simvastatin-collagen composite sponge exhibited satisfactory biocompatibility with the pulp tissue and promoted the formation of reparative dentin. The application of simvastatin-collagen composite sponge as a pulp-capping material has satisfactory potential.


Asunto(s)
Recubrimiento de la Pulpa Dental , Dentina Secundaria , Animales , Hidróxido de Calcio , Colágeno , Pulpa Dental , Exposición de la Pulpa Dental , Diente Molar , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , Simvastatina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA