Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Environ Pollut ; 252(Pt B): 1142-1153, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31252112

RESUMEN

Proper management of waste crop residues has been an environmental concern for years. Yellow mealworms (larvae of Tenebrio molitor Linnaeus, 1758) are major insect protein source. In comparison with normal feed wheat bran (WB), we tested five common lignocellulose-rich crop residues as feedstock to rear mealworms, including wheat straw (WS), rice straw (RS), rice bran (RB), rice husk (RH), and corn straw (CS). We then used egested frass for the production of biochar in order to achieve clean production. Except for WS and RH, the crop residues supported mealworms' life activity and growth with consumption of the residues by 90% or higher and degraded lignin, hemicellulose and cellulose over 32 day period. The sequence of degradability of the feedstocks is RS > RB > CS > WS > RH. Egested frass was converted to biochar which was tested for metal removal including Pb(II), Cd(II), Cu(II), Zn(II), and Cr(VI). Biochar via pyrolysis at 600 °C from RS fed frass (FRSBC) showed the best adsorption performance. The adsorption isotherm fits the Langmuir model, and kinetic analysis fits the Pseudo-Second Order Reaction. The heavy metal adsorption process was well-described using the Intra-Particle Diffusion model. Complexation, cation exchange, precipitation, reduction, deposition, and chelation dominated the adsorption of the metals onto FRSBC. The results indicated that crop residues (WS, RS, RB, and CS) can be utilized as supplementary feedstock along with biochar generated from egested frass to rear mealworms and achieve clean production while generating high-quality bioadsorbent for environment remediation and soil conditioning.


Asunto(s)
Carbón Orgánico/química , Restauración y Remediación Ambiental/métodos , Metales Pesados/química , Tenebrio/fisiología , Adsorción , Animales , Biomasa , Dieta , Cinética , Lignina , Metales Pesados/análisis , Oryza/metabolismo , Suelo/química , Contaminantes del Suelo/análisis , Triticum/metabolismo , Zea mays/metabolismo
2.
J Endod ; 41(1): 56-61, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25442721

RESUMEN

INTRODUCTION: The cytotoxicity of 2 novel calcium silicate-containing endodontic sealers to human gingival fibroblasts was studied. METHODS: EndoSequence BC (Brasseler, Savannah, GA), MTA Fillapex (Angelus Indústria de Produtos Odontológicos S/A, Londrina, PR, Brazil) and a control sealer (AH Plus; Dentsply DeTrey GmbH, Konstanz, Germany) were evaluated. Human gingival fibroblasts were incubated for 3 days both with the extracts from fresh and set materials in culture medium and cultured on the surface of the set materials in Dulbecco-modified Eagle medium. Fibroblasts cultured in Dulbecco-modified Eagle medium were used as a control group. Cytotoxicity was evaluated by flow cytometry, and the adhesion of the fibroblasts to the surface of the set materials was assessed using scanning electron microscopy. The data of cell cytotoxicity were analyzed statistically using a 1-way analysis of variance test at a significance level of P < .05. RESULTS: Cells incubated with extracts from BC Sealer showed higher viabilities at all extract concentrations than cells incubated with extracts from freshly mixed AH Plus and fresh and set MTA Fillapex, esspecially for the high extract concentrations (1:2 and 1:8 dilutions). Extracts from set MTA Fillapex of 2 weeks and older were more cytotoxic than extracts from freshly mixed and 1-week-old cement. With extract concentrations of 1:32 and lower, MTA Fillapex was no longer cytotoxic. After setting, AH Plus was no longer cytotoxic, and the fibroblast cells grew on set AH Plus equally as well as on BC Sealer. CONCLUSIONS: BC Sealer and MTA Fillapex, the 2 calcium silicate-containing endodontic sealers, exhibited different cytotoxicity to human gingival fibroblasts.


Asunto(s)
Compuestos de Calcio/toxicidad , Materiales de Obturación del Conducto Radicular/toxicidad , Silicatos/toxicidad , Compuestos de Aluminio/química , Compuestos de Aluminio/toxicidad , Compuestos de Calcio/química , Fosfatos de Calcio/química , Fosfatos de Calcio/toxicidad , Adhesión Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Medios de Cultivo , Cementos Dentales/química , Cementos Dentales/toxicidad , Combinación de Medicamentos , Resinas Epoxi/química , Resinas Epoxi/toxicidad , Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Encía/citología , Encía/efectos de los fármacos , Encía/crecimiento & desarrollo , Cementos de Ionómero Vítreo/química , Cementos de Ionómero Vítreo/toxicidad , Humanos , Óxidos/química , Óxidos/toxicidad , Materiales de Obturación del Conducto Radicular/química , Silicatos/química
3.
J Endod ; 40(4): 562-5, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24666912

RESUMEN

INTRODUCTION: The purpose of this study was to understand how fatigue affects the torsional properties of both traditional nickel-titanium (NiTi) and NiTi controlled memory (CM) files. METHODS: Typhoon (TYP; Clinician's Choice Dental Products, New Milford, CT) 25/.04 and 40/.04 rotary files in both NiTi and CM were tested to obtain the mean number of cycles of failure (Nf) using a 3-point bending apparatus. New files were then precycled to 4 conditions (0%, 25%, 50%, and 75% of the Nf), and torsional resistance tests were performed. Each file was exposed to torsional stress until failure, and at that point the torque and distortion angles were measured. The fracture surface of each fragment was examined with a scanning electron microscope. RESULTS: TYP CM files had an Nf 7 times higher than that of TYP files (P < .05). No difference in torque between the CM files and the conventional NiTi files of either file size was detected (P > .05). The torque of the size 40/.04 files was significantly higher than the torque of the size 25/.04 files (P < .05). In the 40/.04 files group, TYP files in the 75% precycling group had a significantly lower torque than files in the group with no precycling (P < .05), whereas slight precycling (25%) significantly reduced the distortion angle on TYP CM files (P < .05). The CM files of both sizes had a significantly higher distortion angle than the corresponding NiTi files (P < .05). The fractured files in the precycling groups showed the typical pattern of torsional failure. CONCLUSIONS: Within the same amount of precycling (25%, 50%, and 75%), the cyclic fatigue life of TYP CM instruments was significantly higher than that of the TYP instruments. However, the torque value of TYP CM was similar to TYP files. The larger instruments were not only less resistant to cyclic fatigue but were affected most by prestressing of both TYP and TYP CM files.


Asunto(s)
Aleaciones Dentales/química , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Diseño de Equipo , Falla de Equipo , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Docilidad , Estrés Mecánico , Propiedades de Superficie , Temperatura , Torque , Torsión Mecánica , Agua/química
4.
J Endod ; 39(2): 163-72, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23321225

RESUMEN

INTRODUCTION: The performance and mechanical properties of nickel-titanium (NiTi) instruments are influenced by factors such as cross-section, flute design, raw material, and manufacturing processes. Many improvements have been proposed by manufacturers during the past decade to provide clinicians with safer and more efficient instruments. METHODS: The mechanical performance of NiTi alloys is sensitive to their microstructure and associated thermomechanical treatment history. Heat treatment or thermal processing is one of the most fundamental approaches toward adjusting the transition temperature in NiTi alloy, which affects the fatigue resistance of NiTi endodontic files. The newly developed NiTi instruments made from controlled memory wire, M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK), or R-phase wire represent the next generation of NiTi alloys with improved flexibility and fatigue resistance. The advantages of NiTi files for canal cleaning and shaping are decreased canal transportation and ledging, a reduced risk of file fracture, and faster and more efficient instrumentation. The clinician must understand the nature of different NiTi raw materials and their impact on instrument performance because many new instruments are introduced on a regular basis. RESULTS: This review summarizes the metallurgical properties of next-generation NiTi instruments, the impact of thermomechanical treatment on instrument flexibility, and the resistance to cyclic fatigue and torsion. CONCLUSIONS: The aim of this review was to provide clinicians with the knowledge necessary for evidence-based practices, maximizing the benefits from the selection and application of NiTi rotary instruments for root canal treatment.


Asunto(s)
Aleaciones Dentales/química , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Diseño de Equipo , Humanos , Fenómenos Mecánicos , Docilidad , Estrés Mecánico , Propiedades de Superficie , Termodinámica , Temperatura de Transición
5.
J Endod ; 39(7): 919-23, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23791264

RESUMEN

INTRODUCTION: The bending and torsional properties of thermomechanically treated K3XF (SybronEndo, Orange, CA) nickel-titanium instruments in relation to their phase transformation behavior were evaluated. METHODS: NiTi instruments K3 (SybronEndo) and K3XF, both in sizes 25/.04 and 40/.04, were examined by differential scanning calorimetry and X-ray diffraction. The metal composition was determined by scanning electron microscopy with X-ray energy-dispersive spectrometric analyses. The bending property of K3 and K3XF instruments was measured in a cantilever-bending test with a maximum deflection of 4.00 mm. A torsional test of the instruments was evaluated according to the American National Standards Institute/American Dental Association Specification No. 28. RESULTS: K3 and K3XF instruments had approximately the same chemical composition with a nickel content of 48-49 atomic %. The differential scanning calorimetry analyses showed that each segment of the K3XF instruments (24.89°C ± 1.98°C) had a higher austenite finish temperature than the K3 instruments (17.63°C ± 1.76°C) (P < .05). The bending load values were significantly lower for K3XF than for K3 in the superelastic ranges (P < .05). There was no statistically significant difference between K3 and K3XF in the maximum torque or maximum angular deflection before failure. The torque at fracture values of K3 and K3XF increased significantly with the diameter (P < .05). CONCLUSIONS: K3XF exhibited different phase transformation behavior and flexibility when compared with K3, which may be attributed to the special heat treatment history of K3XF instruments.


Asunto(s)
Aleaciones Dentales/química , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Rastreo Diferencial de Calorimetría , Fenómenos Químicos , Elasticidad , Diseño de Equipo , Calor , Humanos , Ensayo de Materiales , Fenómenos Mecánicos , Microscopía Electrónica de Rastreo , Docilidad , Espectrometría por Rayos X , Temperatura , Torque , Torsión Mecánica , Difracción de Rayos X
6.
J Endod ; 39(10): 1281-6, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24041392

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the pH change, viscosity and other physical properties of 2 novel root canal sealers (MTA Fillapex and Endosequence BC) in comparison with 2 epoxy resin-based sealers (AH Plus and ThermaSeal), a silicone-based sealer (GuttaFlow), and a zinc oxide-eugenol-based sealer (Pulp Canal Sealer). METHODS: ISO 6876/2001 specifications were followed. The pH change of freshly mixed and set sealers was evaluated during periods of 1 day and 5 weeks, respectively. The viscosity was investigated at different injection rates (72, 10, and 5 mm/min) at room temperature by using a syringe-based system that was based on the Instron 3360 series universal testing system. RESULTS: The flow, dimensional change, solubility, and film thickness of all the tested sealers were in agreement with ISO 6876/2001 recommendations. The MTA Fillapex sealer exhibited a higher flow than the Endosequence BC sealer (P < .05). The MTA Fillapex and Endosequence BC sealers showed the highest film thicknesses among the tested samples. The Endosequence BC sealer exhibited the highest value of solubility, which was in accordance with 3% mass fraction recommended by the ISO 6876/2001, and showed an acceptable dimensional change. The MTA Fillapex and Endosequence BC sealers presented an alkaline pH at all times. The pH of fresh samples of the AH Plus and ThermaSeal sealers was alkaline at first but decreased significantly after 24 hours. The viscosity of the tested sealers increased with the decreased injection rates. CONCLUSIONS: The tested sealers were pseudoplastic according to their viscosities as determined in this study. The MTA Fillapex and Endosequence BC sealers each possessed comparable flow and dimensional stability but higher film thickness and solubility than the other sealers tested.


Asunto(s)
Materiales de Obturación del Conducto Radicular/química , Álcalis/química , Compuestos de Aluminio/química , Compuestos de Calcio/química , Fosfatos de Calcio/química , Fenómenos Químicos , Análisis del Estrés Dental/instrumentación , Dimetilpolisiloxanos/química , Combinación de Medicamentos , Resinas Epoxi/química , Gutapercha/química , Humanos , Concentración de Iones de Hidrógeno , Ensayo de Materiales , Óxidos/química , Silicatos/química , Solubilidad , Propiedades de Superficie , Jeringas , Temperatura , Factores de Tiempo , Viscosidad , Cemento de Óxido de Zinc-Eugenol/química
7.
J Endod ; 39(4): 478-83, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23522540

RESUMEN

INTRODUCTION: This study examined the effect of a new bioactive dentin substitute material (Biodentine) on the viability of human gingival fibroblasts. METHODS: Biodentine, White ProRoot mineral trioxide aggregate (MTA), and glass ionomer cement were evaluated. Human gingival fibroblasts were incubated for 1, 3, and 7 days both in the extracts from immersion of set materials in culture medium and directly on the surface of the set materials immersed in culture medium. Fibroblasts cultured in Dulbecco modified Eagle medium were used as a control group. Cytotoxicity was evaluated by flow cytometry, and the adhesion of human gingival fibroblasts to the surface of the set materials was assessed by using scanning electron microscopy. The data of cell cytotoxicity were analyzed statistically by using a one-way analysis of variance test at a significance level of P< .05. RESULTS: Cells exposed to extracts from Biodentine and MTA showed the highest viabilities at all extract concentrations, whereas cells exposed to glass ionomer cement extracts displayed the lowest viabilities (P< .05). There was no significant difference in cell viabilities between Biodentine and MTA during the entire experimental period (P> .05). Human gingival fibroblasts in contact with Biodentine and MTA attached to and spread over the material surface after an overnight culture and increased in numbers after 3 and 7 days of culture. CONCLUSIONS: Biodentine caused gingival fibroblast reaction similar to that by MTA. Both materials were less cytotoxic than glass ionomer cement.


Asunto(s)
Compuestos de Calcio/toxicidad , Encía/efectos de los fármacos , Materiales de Recubrimiento Pulpar y Pulpectomía/toxicidad , Silicatos/toxicidad , Compuestos de Aluminio/toxicidad , Análisis de Varianza , Adhesión Celular/efectos de los fármacos , Proliferación Celular/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Células Cultivadas , Combinación de Medicamentos , Fibroblastos/efectos de los fármacos , Citometría de Flujo , Encía/citología , Cementos de Ionómero Vítreo/toxicidad , Humanos , Óxidos/toxicidad
8.
J Endod ; 38(11): 1535-40, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23063231

RESUMEN

INTRODUCTION: The aim of this study was to investigate the structure and mechanical properties of newly developed controlled memory (CM) nickel-titanium wires used in the manufacture of rotary endodontic instruments. METHODS: The composition and the phase transformation behavior of both types of wires were examined by x-ray energy dispersive spectroscopy and differential scanning calorimetry, respectively. Conventional superelastic (SE) nickel-titanium wire was used as a control. The mechanical properties of the wires at selected temperatures (room temperature, 37°C, and 60°C) were evaluated with tensile, cyclic tensile, and cantilever bending tests by using an Instron 3365 universal testing machine. The data of austenitic transformation finishing temperature (A(f)) were analyzed statistically by using 1-way analysis of variance test at a significance level of P < .05. RESULTS: The raw CM wires contained a nickel content of 50.7% ± 0.5% and possessed a relatively higher A(f) than SE wires (P < .05). The critical plateau stress and ultimate tensile strength of the CM wires were lower than they were for the SE wires, but the maximum strain before fracture of the CM wires (58.4% ± 7.5% to 84.7% ± 6.8%) was more than 3 times higher than it was for SE wires (16.7% ± 3.8% to 27.5% ± 5.4%). The maximum strain of the CM wires with a diameter of 1.22 mm tested at room temperature (23°C ± 2°C) was up to 84% ± 6.4%. CM wires were not SE at either room temperature or 37°C; however, they exhibited superelasticity when heated to 60°C. CONCLUSIONS: The raw CM wires exhibited different phase transformation behavior and mechanical properties when compared with SE wires, attributing to the special heat treatment history of CM wires. This study suggested greater flexibility of endodontic instruments manufactured with CM wires than similar instruments made of conventional SE wires.


Asunto(s)
Aleaciones Dentales/química , Instrumentos Dentales , Diseño de Equipo , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Elasticidad , Ensayo de Materiales , Fenómenos Mecánicos , Metalurgia
9.
J Endod ; 38(12): 1613-7, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23146647

RESUMEN

INTRODUCTION: The aim of the study was to analyze the incidence and mode of ProFile Vortex instrument (Dentsply Tulsa Dental Specialties, Tulsa, OK) defects during a predefined schedule of clinical use by the undergraduate students in a dental school setting and to examine the metallurgical characteristics of unused and clinically used Vortex instruments. METHODS: A total of 2,203 ProFile Vortex instruments discarded after single use from the undergraduate students program over 24 months were collected and examined for defects using a stereomicrosocpe at 10× magnification. The incidence and type of instrument defects or separation were analyzed. The lateral surfaces of part of the defected instruments and fracture surfaces of fractured files were examined using scanning electron microscopy. Unused and clinically used files were examined by differential scanning calorimetry and X-ray diffraction. Vickers hardness of the files was measured with a 200-g load. RESULTS: Only 1 of the 2,203 files fractured during clinical use. The cause of fracture was shear stress, and the file also showed unwinding of the helix structure. None of the remaining 2,202 files exhibited unwinding after clinical use. Blunt apicals were detected in 86 used files (3.9%). Austenite-finish temperatures were very similar for as-received, used files with defects and used files without defects, all exceeding 50°C. No difference in microhardness was detected among these 3 instrument groups. X-ray diffraction results showed that NiTi files had austenite structure at room temperature. CONCLUSIONS: The risk of ProFile Vortex fracture is very low when files are used 1 time by undergraduate students. Unwinding of the files was not detected except for the fractured file. Clinical single use had no detectable effect on austenite-martensite phase transformation of the files. Unused and clinical single-use files contain a similar phase structure at body temperature.


Asunto(s)
Aleaciones Dentales/química , Níquel/química , Preparación del Conducto Radicular/instrumentación , Titanio/química , Rastreo Diferencial de Calorimetría , Diseño de Equipo , Falla de Equipo , Dureza , Humanos , Ensayo de Materiales , Metalurgia , Microscopía Electrónica de Rastreo , Estrés Mecánico , Propiedades de Superficie , Temperatura , Torsión Mecánica , Difracción de Rayos X
10.
Zhonghua Shao Shang Za Zhi ; 28(4): 244-7, 2012 Aug.
Artículo en Zh | MEDLINE | ID: mdl-23248957

RESUMEN

OBJECTIVE: To observe the clinical effect of the concentrated suture fixation method on skin transplantation on deep burn wound or wound of cicatricial deformity after burn in the jaw and neck region. METHODS: One hundred and fourteen patients, hospitalized from April 2002 to December 2011, with deep burn or cicatricial deformity after burn in the jaw and neck region, were divided into packaging group and concentrated suture group according to the random number table. Each group had 57 patients including 48 cases with deep burn and 9 cases with cicatricial deformity. Traditional suture-package fixation method and concentrated suture fixation method were respectively used in packaging group and concentrated suture group to fix the autologous medium split-thickness skin in transplantation on wounds or scars. On post operation day (POD) 14, the skin microcirculatory perfusion flow of skin graft was measured, and the occurrence of ecchymoma, infection, and necrosis of skin in operative region were observed. The elasticity and contracture of grafted skin and scar hyperplasia on wound edge were observed 6 months after operation. Measurement data were processed with u test, while enumeration data with Fisher's exact test or Chi-square test. RESULTS: (1) On POD 14, the skin microcirculatory perfusion flow in concentrated suture group [(2.86 +/- 0.8) V] was significantly higher than that in packaging group [(2.33 +/- 0.15) V, u = 17.776, P < 0.05]. (2) Ecchymoma occurred in 4 patients of packaging group and 3 patients of concentrated suture group, but the difference between two groups was not statistically significant (chi 2 = 0.152, P > 0.05). (3) Infection in operative region was observed in 1 patient of packaging group, while no patient in concentrated suture group showed this symptom. The difference between two groups was not statistically significant (P > 0.05). (4) Grafted skin in 6 patients of packaging group showed foliated necrosis, which was not observed on those of patients in concentrated suture group. The difference between two groups was statistically significant (P < 0.05). (5) Centipede leg-like scar hyperplasia on wound edge occurred in 21 patients in packaging group and 6 patients in concentrated suture group, and the difference between two groups was statistically significant (chi 2 = 10.920, P < 0.05). (6) Poor elasticity of grafted skin was detected in 17 patients of packaging group and 4 patients of concentrated suture group, and the difference between two groups was statistically significant (chi 2 = 9.865, P < 0.05). (7) Obvious contracture of grafted skin was observed in 15 patients of packaging group and 4 patients of concentrated suture group, and the difference between two groups was statistically significant (chi 2 = 11.684, P < 0.05). CONCLUSIONS: Concentrated suture fixation method is suitable for application in transplantation of big sheet skin on wound in the jaw and neck region. It has high survival rate and is convenient for postoperative observation.


Asunto(s)
Quemaduras/cirugía , Trasplante de Piel/métodos , Suturas , Adulto , Cicatriz/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Cuello/cirugía , Procedimientos Quirúrgicos Ortognáticos , Trasplante Autólogo , Resultado del Tratamiento
11.
J Endod ; 37(11): 1566-71, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22000465

RESUMEN

INTRODUCTION: To improve the fracture resistance of nickel-titanium (NiTi) files, manufacturers have introduced new alloys and developed new manufacturing processes for the fabrication of NiTi files. This study aimed to examine the phase transformation behavior and microstructure of NiTi instruments from a novel controlled memory NiTi wire (CM wire). METHODS: Instruments of EndoSequence (ES), ProFile (PF), ProFile Vortex (Vortex), Twisted Files (TF), Typhoon (TYP), and Typhoon™ CM (TYP CM), all size 25/.04, were examined by differential scanning calorimetry (DSC) and x-ray diffraction (XRD). Microstructures of etched instruments were observed by optical microscopy and scanning electron microscopy with x-ray energy-dispersive spectrometric (EDS) analyses. RESULTS: The DSC analyses showed that each segment of the TYP CM and Vortex instruments had an austenite transformation completion or austenite-finish (A(f)) temperature exceeding 37°C, whereas the NiTi instruments made from conventional superelastic NiTi wire (ES, PF, and TYP) and TF had A(f) temperatures substantially below mouth temperature. The higher A(f) temperature of TYP CM instruments was consistent with a mixture of austenite and martensite structure, which was observed at room temperature with XRD. All NiTi instruments had room temperature martensite microstructures consisting of colonies of lenticular features with substantial twinning. EDS analysis indicated that the precipitates in all NiTi instruments were titanium-rich, with an approximate composition of Ti(2)Ni. CONCLUSIONS: The TYP CM and Vortex instruments with heat treatment contribute to increase austenite transformation temperature. The CM instrument has significant changes in the phase transformation behavior, compared with conventional superelastic NiTi instruments.


Asunto(s)
Aleaciones Dentales , Instrumentos Dentales , Níquel , Preparación del Conducto Radicular/instrumentación , Titanio , Rastreo Diferencial de Calorimetría , Elasticidad , Metalurgia , Microscopía Electrónica de Rastreo , Transición de Fase , Espectrometría por Rayos X , Difracción de Rayos X
12.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 28(2): 166-9, 2010 Apr.
Artículo en Zh | MEDLINE | ID: mdl-20480660

RESUMEN

OBJECTIVE: To assess the early variation of clinical periodontal indexes and Porphyronwnas gingivulis (Pgingivalis) in subgingival plaques of orthodontic adults. METHODS: 11 orthodontic adults were selected. Clinical periodontal indexes of observed teeth were examined at three different time points: Before orthodontic treatment, the first month after treatment and the third month after treatment, and subgingival plaques were collected simultaneously at each time point. Clinical periodontal indexes included four ones: Plaque index (PU), sulcus bleeding index (SBI), probing depth (PD), and attachment loss. We used real-time quantitative polymerase chain reaction to detect and quantitate the number of total bacteria and P.gingivalis in each sample to obtain positive rate of P.gingivalis and the percentage of P. gingiaalis in total bacteria. RESULTS: PLI and SBI of the first and third month were more than that of the baseline (P < 0.05). PD rose at the first month after treatment (P < 0.05), and then dropped at the third month. PD of all the 11 participants was lower than 2 mm. No attachment loss was found. The positive rate of P.gingivolis was stable (45.5%) and the proportion of Pgingivalis had no significant difference (p > 0.05) at each time point. CONCLUSION: Fixed orthodontic appliances caused plaque accumulation, accordingly slight gingiva inflammation and the increasement of P.gingivalis occurred in the early stage, hut none periodontitis was found.


Asunto(s)
Bolsa Periodontal , Porphyromonas gingivalis , Adulto , Bacterias , Placa Dental , Índice de Placa Dental , Encía , Humanos , Masculino , Índice Periodontal , Periodontitis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA