Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Oral Health ; 18(1): 39, 2018 03 12.
Artículo en Inglés | MEDLINE | ID: mdl-29530000

RESUMEN

BACKGROUND: The VicRK two-component signalling system regulates virulence and cariogenicity in Streptococcus mutans (S. mutans). The purpose of this study was to explore the genetic polymorphisms of the vicR and vicK genes, which are associated with dental caries in children with S. mutans. METHODS: In this study, 121 (from each group) clinical S. mutans strains were isolated from caries-free children and children with high-severity caries to sequence the vicR and vicK genes. Genomic DNA was extracted from S. mutans strains and amplified using PCR. The PCR products were purified and sequenced. A chi-squared test and ABI Variant Reporter software were used to analyse the sequencing results. RESULTS: The 242 clinically isolated S. mutans strains contained the full-length vicR and vicK genes. No nucleotide sequence insertions or deletions were observed in the two genes. Four silent point mutations were identified in the vicR genes, and no missense mutations could be detected. Forty-one mutations were identified in the vicK genes. In addition to 32 silent mutations, 9 missense mutations at the 173, 337, 470, 1051, 1132, 1258, 1260, 1277, and 1348 bp positions were found. The distribution frequencies of the missense mutations were not significantly different between the groups, except for the C470T mutation. The frequency of the C470T missense mutation was higher in the high-severity caries group than in the caries-free group. CONCLUSIONS: vicR sequences are highly conserved in S. mutans clinical isolates. The locus 470 missense mutation of the vicK gene may be related to caries in children with S. mutans.


Asunto(s)
Proteínas Bacterianas/genética , Caries Dental/microbiología , Genes Bacterianos/genética , Polimorfismo Genético/genética , Streptococcus mutans/genética , Preescolar , Caries Dental/etiología , Humanos , Mutación Missense/genética , Mutación Puntual/genética , Reacción en Cadena de la Polimerasa , Análisis de Secuencia de ADN , Mutación Silenciosa/genética , Streptococcus mutans/patogenicidad
2.
J Oral Maxillofac Surg ; 74(2): 401-5, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26452430

RESUMEN

PURPOSE: Although negative-pressure wound therapy (NPWT) for complicated wounds has been extensively studied, it is rarely used in cases involving a submandibular fistula due to radiation-induced osteoradionecrosis of the mandible. This study aimed to investigate the efficacy of NPWT for submandibular fistulas after reconstruction for osteoradionecrosis. PATIENTS AND METHODS: Nine patients with submandibular fistulas after reconstruction for osteoradionecrosis treated with NPWT between 2011 and 2014 were included in the study. The wound healing was documented. RESULTS: The NPWT device was removed postoperatively between days 7 and 12 (mean duration, 9.6 days). The wound bed was filled with healthy granulation tissue, and successful healing by second intention was observed in all patients within 2 weeks. No complications were observed. The follow-up ranged from 4 to 27 months (mean, 18 months); the fistulas exhibited excellent healing, and no recurrence or infection was observed. CONCLUSIONS: NPWT is a safe, effective technique for managing submandibular fistulas after reconstruction for osteoradionecrosis.


Asunto(s)
Enfermedades Mandibulares/cirugía , Reconstrucción Mandibular/métodos , Terapia de Presión Negativa para Heridas/métodos , Osteorradionecrosis/cirugía , Fístula de las Glándulas Salivales/terapia , Enfermedades de la Glándula Submandibular/terapia , Anciano , Placas Óseas , Trasplante Óseo/métodos , Remoción de Dispositivos , Femenino , Estudios de Seguimiento , Colgajos Tisulares Libres/trasplante , Supervivencia de Injerto , Humanos , Masculino , Reconstrucción Mandibular/instrumentación , Persona de Mediana Edad , Colgajo Miocutáneo/trasplante , Neoplasias Nasofaríngeas/radioterapia , Músculos Pectorales/trasplante , Dehiscencia de la Herida Operatoria/etiología , Cicatrización de Heridas/fisiología
3.
J Prosthet Dent ; 114(5): 715-24, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26213266

RESUMEN

STATEMENT OF PROBLEM: The effects of different heat treatments on the internal oxidation and metal-ceramic bond in Pd-Ag alloys with different trace elements require further documentation. PURPOSE: The purpose of this in vitro study was to determine whether heat treatment affects the metal-ceramic bond strength of 2 Pd-Ag alloys containing different trace elements. MATERIAL AND METHODS: Thirteen cast specimens (25×3×0.5 mm) from each of 2 Pd-Ag alloy groups (W-1 and Argelite 61+3) were allocated to heat treatments before porcelain application: heating under reduced atmospheric pressure of 0.0014 MPa and 0.0026 MPa and heating under normal atmospheric pressure. Bond strengths were evaluated using a 3-point bending test according to ISO9693. Results were analyzed using 2-way ANOVA and Tukey HSD test (α=.05). Visual observation was used to determine the failure types of the fractured specimens. Scanning electron microscopy and energy dispersive spectroscopy were used to study morphologies, elemental compositions, and distributions in the specimens. RESULTS: The W-1 group had a mean bond strength significantly higher than that of Argelite 61+3 (P<.001). Heating under reduced atmospheric pressures of 0.0014 MPa and 0.0026 MPa resulted in similar bond strengths (P=.331), and both pressures had significantly higher bond strengths than that of heating under normal atmospheric pressure (P=.002, P<.001). Heating under different air pressures resulted in Pd-Ag alloys that contained either Sn or In and Ga, with various degrees of internal oxidation and different quantities of metallic nodules. CONCLUSIONS: Heating under reduced atmospheric pressure effectively improved the bond strength of the ceramic-to-Pd-Ag alloys.


Asunto(s)
Materiales Dentales/efectos de la radiación , Calor , Aleaciones de Cerámica y Metal/efectos de la radiación , Paladio/efectos de la radiación , Resistencia al Corte/efectos de la radiación , Plata/efectos de la radiación , Materiales Dentales/química , Calefacción , Ensayo de Materiales , Aleaciones de Cerámica y Metal/química , Microscopía Electroquímica de Rastreo , Espectrometría por Rayos X , Estrés Mecánico
4.
Comput Methods Biomech Biomed Engin ; 23(13): 1034-1040, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32619356

RESUMEN

This study aimed to investigate the effect of miniscrews thread shape on the stress distribution receiving a torque load. Seven thread shapes (S,V1,V2,B1,B2,R1,R2) models were constructed and a 6 Nmm-torque load was applied. The order of maximum equivalent stress (EQV) value was V1 > V2 > B1 > R1 > R2 > B2 > S. The order of maximum displacement of miniscrew (Max DM) value was S > B2 > R1 = V1 > B1 > V2 > R2. Model R2 may be the most appropriate thread shape affording a torque force.


Asunto(s)
Tornillos Óseos , Análisis de Elementos Finitos , Diseño de Aparato Ortodóncico , Estrés Mecánico , Torque , Fenómenos Biomecánicos , Hueso Cortical/patología , Análisis del Estrés Dental , Humanos
5.
J Dent ; 42(3): 319-28, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24316343

RESUMEN

OBJECTIVES: The purpose of this study was to evaluate the efficacy of surface treatments on the bonding properties between a metal and ceramic. METHODS: Sixty metal specimens were divided equally into four groups of 15 samples each. These groups received different treatments (Gr1: 250µm Al2O3+preoxidation; Gr2: 250µm Al2O3+degassing; Gr3: 120µm Al2O3+preoxidation; Gr4: 120µm Al2O3+degassing). Bond strengths were evaluated using a three-point bending test. The results were analyzed using 2-way ANOVA and Tukey's test. Scanning electron microscopy and energy dispersive spectroscopy were used to observe the microscopic features, elemental compositions and distributions, and diffusion in the specimens. Mechanical profiler was used to measure the roughness of metal surface. RESULTS: The bond strengths of the four groups ranged from 45.00±3.63MPa to 51.61±5.91MPa, with significant differences (P<.05). The specimen that received the pretreatment of 250µm Al2O3 air-particle abrasion+degassing had the highest bond strength. Heating under different oxygen partial pressures caused the final Pd-Ag alloys to have varying degrees of internal oxidation and different quantities of metallic nodules. None of the elements in either the ceramic or the Pd-Ag alloy layer diffused into the other layer. CONCLUSIONS: The metal-ceramic specimen subjected to air-particle abrasion with 250µm Al2O3 and degassed before porcelain firing had significantly higher bond strength than specimens treated differently.


Asunto(s)
Recubrimiento Dental Adhesivo , Grabado Dental/métodos , Porcelana Dental/química , Aleaciones de Oro/química , Aleaciones de Cerámica y Metal/química , Paladio/química , Óxido de Aluminio/química , Materiales Dentales/química , Difusión , Calor , Humanos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Oxidación-Reducción , Oxígeno/química , Presión Parcial , Tamaño de la Partícula , Docilidad , Espectrometría por Rayos X , Estrés Mecánico , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA