Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.341
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Periodontal Res ; 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38644743

RESUMEN

AIMS: GBR membranes have various surface properties designed to elicit positive responses in regenerative clinical procedures; dental clinicians attempt to employ techniques to prevent the direct interaction of contaminated oral fluids with these biomaterials. However, saliva is uninterruptedly exhibited in oral surgical procedures applying GBR membranes, suggesting a persistent interaction with biomaterials and the surrounding oral tissues. This fundamental study aimed to investigate potential alterations in the physical, chemical, and key biological properties of membranes for guided bone regeneration (GBR) caused by isolated early interaction with human saliva. METHODS: A reproducible step-by-step protocol for collecting and interacting human saliva with membranes was developed. Subsequently, membranes were evaluated for their physicochemical properties, protein quantification, DNA, and 16S rRNA levels viability of two different cell lines at 1 and 7 days, and ALP activity. Non-interacted membranes and pure saliva of donors were applied as controls. RESULTS: Qualitative morphological alterations were noticed; DNA extraction and 16S quantification revealed significantly higher values. Furthermore, the viability of HGF-1 and MC3T3-E1 cells was significantly (p < .05) reduced following saliva interaction with biodegradable membranes. Saliva contamination did not prejudice PTFE membranes significantly in any biological assay. CONCLUSIONS: These outcomes demonstrated a susceptible response of biodegradable membranes to isolated early human saliva interaction, suggesting impairment of structural morphology, reduced viability to HGF-1 and MC3T3-E1, and higher absorption/adherence of DNA/16S rRNA. As a result, clinical oral procedures may need corresponding refinements.

2.
Macromol Rapid Commun ; : e2400196, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38830612

RESUMEN

The utilization of two-component systems comprising camphorquinone (CQ) and aromatic amines has become prevalent in the photopolymerization. However, there are still concerns about the safety of this CQ/amine system, mainly because of the toxicity associated with the leaching of aromatic amines. In light of these concerns, this study aims to develop novel coinitiator combinations featuring CQ and amines which cannot be leached out of materials, enabling free radical polymerization of representative dentalmethacrylate resins under blue light irradiation. This approach involves the initial design and analysis of hydrogen donors with low C─H bond dissociation energy through molecular modeling. Subsequently, copolymerizable methacrylate functional groups are incorporated via chemical modification, allowing it to act as both coinitiator and copolymerization monomer to achieve low migrationand leachability properties. This work presents, for the first time, the synthesis of the innovative coinitiator and compares its performance with the benchmark CQ/ethyl-4-dimethylaminobenzoate (EDB)-based photoinitiation system (PIS). The results demonstrate the effectiveness of the newly proposed PIS. Finally, an in-depth investigation is conducted into the reaction mechanism associated with this PIS through molecular orbital calculations and electron spin resonance studies.

3.
Eur J Oral Sci ; : e12993, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778467

RESUMEN

This study aimed to investigate the bisphenol A (BPA) release from four CAD/CAM splint materials: three polycarbonate-based (DD BioSplint C, Splint Plus Biostar, Temp Premium Flexible) and one polymethylmethacrylate-based (Temp Basic) material. From each material, ten cylindrical samples (n = 40) were immersed in high-performance liquid chromatography (HPLC) grade water following ISO 10993-12 and incubated for 24 h in an incubation shaker at 37°C and 112 rpm. Following BPA derivatization, analysis was performed by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). After 24 h of incubation, all investigated materials released significant amounts of BPA compared to water blanks. The material-dependent elution increased in the following order: DD BioSplint C < Splint Plus Biostar < Temp Basic < Temp Premium Flexible. Subtracting extraneous BPA, the concentrations ranged between 2.27 ng/mL and 12.65 ng/mL. After extrapolating the concentrations in relation to the average surface area of occlusal splints, the amount of BPA per mL exceeded the Tolerable Daily Intake (TDI) set by the European Union for a person weighing 70 kg by 1.32-6.16 times. Contrary to the release from previously investigated materials, BPA elution from CAD/CAM splint materials was highly elevated. Considering the increasing adaptation of CAD/CAM techniques, elution from them may represent a relevant BPA source in daily dental practice.

4.
Contact Dermatitis ; 90(5): 466-469, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38146793

RESUMEN

BACKGROUND: 2-Hydroxyethyl methacrylate (HEMA) was added to the European baseline series (EBS) in 2019. Few recent data are available on the frequency and relevance of positive reactions to this hapten. OBJECTIVES: To investigate the frequency and relevance of positive patch tests to HEMA in the EBS in a university hospital in Amsterdam, The Netherlands. PATIENTS AND METHODS: Retrospective study in patients with positive patch tests to HEMA investigated between June 2019 and August 2023. RESULTS: Of 2927 consecutive patients, 88 (79 women and 9 men; 3.0%) had a positive reaction to HEMA. The prevalence in women was 3.9%, in men 1.0%. Forty-three (49%) reactions were judged to be of current clinical relevance and 21 (24%) of past relevance. In this group of 64 patients with relevant reactions, 18 (28%) had occupational contact with (meth)acrylate-containing products, of who 11 (61%) were nail stylists. In 46 patients with non-occupational allergic contact dermatitis, 31 (67%) had allergic reactions to nail cosmetics. Glues and glue-containing products accounted for 22% of the materials causing allergic contact dermatitis and dental products for 8%. CONCLUSIONS: Allergic reactions to HEMA are very frequent in women investigated in Amsterdam. Nearly two thirds of cases were caused by nail cosmetics.


Asunto(s)
Cosméticos , Dermatitis Alérgica por Contacto , Dermatitis Profesional , Masculino , Humanos , Femenino , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Estudios Retrospectivos , Pruebas del Parche/métodos , Metacrilatos/efectos adversos , Acrilatos/efectos adversos , Dermatitis Profesional/diagnóstico , Dermatitis Profesional/epidemiología , Dermatitis Profesional/etiología
5.
Int Endod J ; 57(3): 315-327, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38108522

RESUMEN

AIM: This study evaluated the transdentinal cytotoxic effects of enzymatic agents (EA) for chemomechanical carious tissue removal on human dental pulp cells. METHODOLOGY: The groups were based on the performed dentine treatments (n = 8): G1: Positive Control (PC - no treatment); G2: Negative Control (NC - 35% H2 O2 for 2 min); G3: Brix 3000™ (BX) for 30 s; G4: BX for 2 min; G5: Papacarie Duo™ (PD) for 30 s; G6: PD for 2 min. The cells were evaluated for viability (VB; MTT assay) and production of reactive oxygen species (ROS; DCFH-DA assay) and nitric oxide (NO; Griess reagent). A scanning electron microscope provided morphological chemical analyses and energy-dispersive X-ray spectroscopy. The data were submitted to the one-way anova statistical test complemented by Tukey (p < .05). RESULTS: Cell viability decreased by 21.1% and 58.4% in G5 and G6, respectively. ROS production in G3 and G4 maintained basal levels but increased by 171.2% and 75.1% in G5 and G6, respectively. CONCLUSIONS: The Brix3000™ enzymatic agent did not cause indirect cytotoxic effects on pulp cells, regardless of the application time. Conversely, Papacarie Duo™ reduced viability and increased ROS production by pulp cells.


Asunto(s)
Pulpa Dental , Estrés Oxidativo , Humanos , Especies Reactivas de Oxígeno
6.
Luminescence ; 39(5): e4767, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38711417

RESUMEN

Zinc polycarboxylate cement is one of the few dental materials that demonstrate true adhesion to tooth structure. It is suitable for use in living organisms without causing harm. Its strong adhesion to teeth and low level of irritancy are two important parameters for the dental applications. In this study, the dosimetry properties of zinc polycarboxylate cement using thermoluminescence (TL) method were investigated and determined the effectiveness of its use as a good dosimeter. According to the results of this study, the sample shows a good TL properties with three main peaks found around 140°C, 220°C and 330°C. It has a wide linear dose response between 72 Gy and 2.3 kGy and good reusability of the TL peak found at 330°C. Unfortunately, the TL peak intensity values are rapidly faded within a short waiting time interval. Zinc polycarboxylate cement, which is frequently used in dental crowns, can be used as a retrospective dosimeter for measuring the amount of radiation in space studies and nuclear accidents due to its wide linear dose-response curve in the high dose region.


Asunto(s)
Cemento de Policarboxilato , Dosimetría Termoluminiscente , Zinc , Zinc/química , Cemento de Policarboxilato/química , Cementos Dentales/química , Estudios Retrospectivos
7.
Clin Oral Investig ; 28(7): 396, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916682

RESUMEN

OBJECTIVES: The aim of this review was to analyze mechanical and biological properties of resin materials used with subtractive or additive techniques for oral appliances fabrication and compare them to those conventionally manufactured. MATERIALS AND METHODS: The protocol was registered online at Open Science Framework (OSF) registries ( https://osf.io/h5es3 ) and the study was based on the preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P). An electronic search was conducted on MEDLINE (via PubMed), Scopus, and Web of Science from 1 February 2022 to 1 May 2022. INCLUSION CRITERIA: in vitro and in vivo studies published in the last 10 years, with CAD-CAM or 3D printed resins for occlusal splints. Data considered homogenous were subjected to meta-analysis (95% confidence interval [CI]; α = 0.05) with Stata17 statistical software. Since all variables were continuous, the Hedge g measure was calculated. A fixed-effects model was used for I2 = 0%, while statistical analysis was conducted using a random-effects model with I2 > 0%. RESULTS: 13 studies were included after full-text reading. The mechanical properties most studied were wear, flexural strength, surface hardness and surface roughness, while only 1 study investigated biological properties, performing the XTT viability assay. For the meta-analysis, only surface roughness, volume loss, and flexural strength were selected. Considering surface roughness, the subtractive specimen had a lower average value compared to traditional ones (Hedge's g with 95% CI = -1.25[ -1.84, - 0.66]). No significant difference was detected in terms of volume loss (P > 0.05) between the groups (Hedge's g with 95% CI = -0.01 [-2.71, - 2.68]). While flexural strength was higher in the control group (Hedge's g with 95% CI = 2.32 [0.10-4.53]). CONCLUSION: 3D printed materials showed properties comparable to conventional resins, while milled splint materials have not shown better mechanical performance compared with conventional heat-cured acrylic resin. Polyetheretherketone (PEEK) have great potential and needs to be further investigated. Biological tests on oral cell populations are needed to confirm the long-term biocompatibility of these materials. CLINICAL RELEVANCE: The use of "mixed splints" combining different materials needs to be improved and evaluated in future research to take full advantage of different characteristics and properties.


Asunto(s)
Diseño Asistido por Computadora , Impresión Tridimensional , Humanos , Ensayo de Materiales , Polímeros/química , Materiales Dentales/química , Propiedades de Superficie
8.
Odontology ; 2024 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-38502470

RESUMEN

The research exploiting the ability of dental materials to induce or prevent secondary caries (SC) development still seems inconclusive. Controlling bacterial adhesion by releasing bacteriostatic ions and improving the surface structure has been suggested to reduce the occurrence of SC. This paper analyses the impact of five distinctively composed dental materials on cariogenic biofilm formation. Forty-five specimens of three composites (CeramX Spectra ST, Admira Fusion, Beautifil II) and two glass-ionomers (Fuji II LC, Caredyne Restore), respectively, were incubated in bacterial suspension composed of Streptococcus mutans, Lactobacillus acidophilus, Streptococcus mitis, Streptococcus sanguinis, and Streptococcus salivarius at pH 7.0 and 5.5. Coverslips were used as a control. Adhered bacteria were collected after 2, 4, 6, 12, 24, and 48 h and analyzed using quantitative polymerase chain reaction (qPCR). Fluoride leakage was measured at each collection. The specimens' surface topography was assessed using interferometry. In the present study, surface roughness seemed to have a partial role in bacterial adhesion and biofilm formation, together with chemical composition of the materials tested. Despite differences in fluoride leakage, biofilm accumulation was similar across materials, but the number of adhered bacteria differed significantly. A release of other ions may also affect adhesion. These variations suggest that certain materials may be more prone to initiating secondary caries.

9.
Odontology ; 2024 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-38705962

RESUMEN

The aim of this research was to determine if there are differences in early bacterial adhesion among CAD/CAM dental materials after 24 h exposure in the oral environment. One hundred twenty specimens were prepared according to the manufacturer's recommendations and divided into six groups: RBC (resin-based composite), PMMA (polymethyl methacrylate), PEEK (polyether ether ketone), ZP (zirconia polished), ZG (zirconia glazed), and cobalt-chromium alloy (CoCr alloy). Twenty healthy participants were instructed to carry an intraoral device with six specimens, one per group, for 24 h. Thereafter, real-time polymerase chain reaction (qPCR) and scanning electron microscopy (SEM) analyses enabled quantification and 2D view of biofilm formed on the specimens' surfaces. Kruskal-Wallis test and Dunn's post hoc analysis were used for inter-group comparison and data were presented as median (minimum-maximum). RBC specimens accumulated less bacteria, in comparison with ZG (p = 0.017) and PEEK specimens (p = 0.030), that dominated with the highest amount of adhered bacterial biofilm. PMMA, CoCr, and ZP specimens adhered more bacteria than RBC (p > 0.05), and less than ZG (p > 0.05) and PEEK (p > 0.05). The bacterial number varied considerably among participants. The obtained results enable a closer view into the susceptibility of CAD/CAM materials to microorganisms during the presence in the oral environment, which can be beneficial for a proper selection of these materials for a variety of dental restorations.

10.
J Esthet Restor Dent ; 36(6): 951-961, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38497672

RESUMEN

OBJECTIVE: To measure degree of conversion (DC) of a flowable composite, microtensile bond strength (MTBS) to dentine in the snow-plow technique with/without preheating and temperature in the preheated composite. MATERIALS AND METHODS: For DC, snow-plow specimens of Filtek Ultimate Flowable (Flow) and Filtek Bulk Fill (Bulk) (3M) were prepared by light-curing composites simultaneously in standardized molds while in control groups light-curing was separate. DC of Flow was measured using micro-Raman spectroscopy. For MTBS, specimens were prepared on dentine of human extracted molars by simultaneous (snow-plow) or separate (control) light-curing. MTBS was measured using a universal testing machine after 24 h and 6 months. Data were analyzed using ANOVA with Tukey's post hoc (α = 0.05). RESULTS: Increased curing time significantly increased DC in snow-plow from 13.4% ± 11.6% (10 s) to 31.8% ± 4.4% (40 s) albeit significantly lower than controls (p < 0.05). Preheated Bulk improved conversion in snow-plow (44.3% ± 1.7%) and control (50.5% ± 2.6%) (p < 0.05). No significant differences occurred in MTBS between groups (p > 0.05). MTBS values ranged between 66.7 ± 8.4 MPa (snow-plow group_21°C_baseline) and 54.1 ± 15.8 MPa (control_21°C_long-term). Temperature in the preheated Bulk dropped to ~38°C after 30 s. CONCLUSIONS: Snow-plow technique, irrespective of preheating, resulted in lower DC of Flow than separate light-curing of composite increments. Snow-plow, irrespective of preheating, resulted in similar initial and long-term MTBS to dentine. CLINICAL SIGNIFICANCE: Clinicians with preference for flowable composite liners in Class II restorations should be aware that the snow-plow technique of simultaneous light-curing of flowable and bulk-fill composite increments affects monomer-to-polymer conversion, albeit no effect on immediate, and long-term bonding to dentine was detected. Preheating sculptable bulk-fill composite improves conversion of the flowable liner in the snow-plow technique but has no detectable effect on bond strength to dentine.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Dentina , Resistencia a la Tracción , Resinas Compuestas/química , Humanos , Recubrimiento Dental Adhesivo/métodos , Ensayo de Materiales , Calor , Espectrometría Raman , Análisis del Estrés Dental
11.
J Esthet Restor Dent ; 36(4): 680-689, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37941513

RESUMEN

BACKGROUND: Proper light curing is crucial for the success of restorative dentistry and to bond brackets to teeth, yet the responsibility is often delegated to dental assistants (DAs). This study assessed the proficiency and maintenance protocols of DAs when using light-curing units (LCUs) in Saudi Arabia. METHODS: Self-administered questionnaires were distributed to practicing DAs. The questionnaire contained sections on knowledge, adherence to best practices, and how to maintain the LCU. Demographic data were collected as well. Descriptive statistics and linear regressions at a significance level of (p = 0.05) were conducted to identify any relationships that influenced the DAs' LCU knowledge, practice, and maintenance protocols. RESULTS: Among the surveyed DAs, 66% were responsible for using the LCU during treatment, 16% used their fingers for support when light curing, 50% held the LCU tip 1-2 mm from the restoration during curing, and 51% did not have a specific maintenance protocol at their workplace. 70% did not know the output from the LCU, and their educational background correlated with knowledge (b = -14.42, p < 0.001). The type of institution type correlated with adherence to best practices (b = -13.65, p = 0.011), and level of knowledge and adherence to maintenance protocols showed a direct correlation (b = 0.002, p = 0.041). CONCLUSIONS: The findings revealed that a significant percentage of the DAs who replied had insufficient knowledge and did not follow the best practices and maintenance protocols for the LCUs they were using. Their educational background and workplace factors influenced this knowledge gap, while the absence of a maintenance protocol and suboptimal practices were associated with the type of institution. CLINICAL SIGNIFICANCE: To maintain the best practice, clinicians and institutions should improve the education and training of DAs. Otherwise, inadequate light curing by the DAs may jeopardize the long-term success of many dental procedures.


Asunto(s)
Resinas Compuestas , Luces de Curación Dental , Humanos , Resinas Compuestas/química , Curación por Luz de Adhesivos Dentales , Asistentes Dentales , Ensayo de Materiales
12.
J Esthet Restor Dent ; 36(1): 164-173, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38173277

RESUMEN

AIM: The aim of this randomized, prospective, and clinical multicenter study was to compare the overall clinical performance of two restorative options over a 5-year period: individualized CAD/CAM abutments veneered with a hand-layered ceramic, and prefabricated zirconium dioxide abutments veneered with press ceramic and inserted into a single edentulous gap in the anterior maxilla. MATERIALS AND METHODS: Forty subjects were recruited from two universities: 20 from the University of XX and 20 from the University of XY. Each subject received an implant to restore a single edentulous gap in the maxillary anterior region (14-24 FDI). 20 patients were randomized into each Group. Group A received a one-piece single crown produced from a prefabricated zirconia abutment with pressed ceramic and Group B received an individualized CAD/CAM zirconia abutment with a hand-layered technique. After 5 years, the aesthetic and radiographic parameters were assessed. RESULTS: Group A had four dropouts and one failure, resulting in a 95% survival rate and 95% success rate. Group B had two dropouts and two failures which resulted in a 90% survival rate and 90% success rate. No crestal bone level changes were observed, with a mean DIB of 0.06 mm in Group A and 0.09 mm in Group B. No statistically significant differences were present at baseline, 6 months, 1 year, 3 years, or 5 years for DIB values between time points and groups. Pink aesthetic score/white aesthetic score, Peri-Implant and Crown Index, and Implant Crown Aesthetic Index values were stable over time at all five points for both groups. CONCLUSION: Both implant-supported restorative options represent a valuable treatment option for the restoration of implant crowns in the anterior maxilla. CLINICAL SIGNIFICANCE: In general, the use of ceramic abutments in the anterior zone represents a valuable treatment procedure with both standardized and CAD/CAM individualized abutments and following the recommendations from the respective manufacturer(s).


Asunto(s)
Cerámica , Circonio , Humanos , Estudios Prospectivos , Coronas , Diseño Asistido por Computadora , Pilares Dentales , Titanio
13.
J Esthet Restor Dent ; 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38923782

RESUMEN

INTRODUCTION: Erbium-doped yttrium-aluminum-garnet (Er:YAG) laser debonding of zirconia and lithium disilicate restorations is increasingly used for a range of clinical applications. Using rotary instruments to remove such restorations for any purpose has proven to be challenging. Erbium laser has been reported to be a conservative method for removing ceramic restorations. There is little data in the literature about the effect of adhesive resin cement type on the debonding time of the ceramic restoration using the Er:YAG laser. OBJECTIVES: To evaluate and compare the time required for the Er:YAG laser to debond zirconia and lithium disilicate crowns bonded with a 2- and 1-bottle adhesive resin cement systems. MATERIALS AND METHODS: Forty extracted premolar teeth were prepared and scanned for milled 40 CAD/CAM crowns. Teeth were randomly assigned into groups (n = 10 per group): 3 mol% yttria-partially stabilized zirconia crowns 3Y-PSZ (G1a) bonded with Panavia™ V5 (2-bottle adhesive resin cement), Zirconia 3Y-PSZ crowns (G1b) bonded with RelyX™ Ultimate (1-bottle adhesive resin cement), and for the lithium disilicate crowns bonded with the two types of cements (G2a, G2b). Each specimen was irradiated with an Er:YAG laser at 335 mJ, 15 Hz, 5.0 W, and 50-ms pulse duration (super short pulse mode). The irradiation time required for crowns to be successfully debonded was recorded for each specimen. Data were statistically analyzed using ANOVA and Tukey HSD post-hoc test (p < 0.05), at the 95 percent level of confidence. The intaglio surface of the debonded crown was analyzed using scanning electron microscopy (SEM). RESULTS: The mean ± standard deviation times needed for crown debonding were 5.75 ± 2.00 min for the G1a group, 4.79 ± 1.20 min for group G1b, 1.69 ± 0.49 min for group G2a, and 1.12 ± 0.17 for group G2b. There was no statistically significant difference in debonding time between the 2- and 1- bottle adhesive resin cement within the groups G1a and b (p = 0.2914), or between groups G2a b (p = 0.7116). A statistically significant difference (p < 0.05) was found between groups G1a and G2a and b and between groups G1b and G2a and b were SEM analysis showed no changes in the microstructure of the ceramic surface after Er:YAG laser irradiation. CONCLUSION: Zirconia and lithium disilicate restorations can be debonded using Er:YAG lasers in a safe and efficient manner. There is no significant difference in the debonding time between the 2- and 1- bottle adhesive resin cement systems used in this study. CLINICAL SIGNIFICANCE: Retrieving zirconia and lithium disilicate ceramics can be a challenging process when using diamond rotary instruments. ER:YAG lasers may efficiently debond these ceramics from the tooth structure, independent of the bonding process used for bonding them.

14.
Int J Paediatr Dent ; 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38590044

RESUMEN

BACKGROUND: The evidence underpinning caries management for children has progressed dramatically over the past 20 years. Anecdotally, this is not reflected in the teaching provided to undergraduate dental students, with the ongoing teaching of outdated methods within some dental schools. AIM: To capture the current undergraduate teaching provision and clinical treatment experience requirement relative to caries management in paediatric dentistry in UK dental schools. DESIGN: Cross-sectional analysis of current teaching methods on paediatric caries management was obtained using a piloted online data collection form. Question content included current caries teaching methods, assessment of student exposure and competence. The results were analysed descriptively. RESULTS: Of the 16 UK dental schools, 14 participated. Discrepancy in teaching content was apparent. Many schools (n = 9) taught biological caries management through therapeutic fissure sealants, yet this was not reflected in assessment and clinical requirements. Some schools (n = 4) taught amalgam placement in children, and most (n = 12) operatively taught treatments that would no longer be routinely provided in general dental practice in the UK, including primary tooth pulpotomy. CONCLUSION: There is substantial variation in the paediatric caries management techniques that are taught across UK dental schools, demonstrating a need for a national consensus to address these disparities.

15.
Int J Paediatr Dent ; 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38676286

RESUMEN

BACKGROUND: International data suggest that parents may have reservations about the use of silver diamine fluoride (SDF). AIM: The aims of this study were to: (1) examine the acceptance of parents/carers towards the use of SDF for the management of caries in children's primary teeth in secondary care dental settings in the UK and the United States and (2) determine which factors may affect the acceptance of the use of SDF. DESIGN: This was a cross-sectional questionnaire of SDF acceptability, completed by parents of young children. It was validated and adapted to local populations. Data were analysed with descriptive and inferential statistics. RESULTS: Of the 113 Sheffield parents, 73% reported that they would accept SDF treatment of children's posterior teeth, with 58% reporting this for anterior teeth. Parents having less concern about posterior aesthetics had a statistically significant effect on reported acceptance of SDF (p = .013). In the Colorado sample (n = 104), 72% reported that they would accept SDF on posterior teeth, and 58% reported that they would accept SDF on anterior teeth. Concerns about aesthetics had an effect on decreasing SDF acceptance overall (p = .0065) in anterior (p = .023) and posterior teeth (p = .108). CONCLUSION: The majority of parents in the two study populations accepted the treatment using SDF. However, concern about aesthetics had an influence on acceptability.

16.
BMC Oral Health ; 24(1): 337, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38491485

RESUMEN

BACKGROUND: The selection of post-core material holds significant importance in endodontically treated teeth, influencing stress distribution in the dental structure after restoration. The use of computer-aided design/computer-aided manufacturing (CAD/CAM) glass fiber post-core possesses a better adaptation for different root canal morphologies, but whether this results in a more favorable stress distribution has not been clearly established. MATERIALS AND METHODS: This study employed finite element analysis to establish three models of post-core crown restoration with normal, oversized, and dumbbell-shaped root canals. The three models were restored using three different materials: CAD/CAM glass fiber post-core (CGF), prefabricated glass fiber post and resin core (PGF), and cobalt-chromium integrated metal post-core (Co-Cr), followed by zirconia crown restoration. A static load was applied and the maximum equivalent von Mises stress, maximum principal stress, stress distribution plots, and the peak of maximum displacement were calculated for dentin, post-core, crown, and the cement acting as the interface between the post-core and the dentin. RESULTS: In dentin of three different root canal morphology, it was observed that PGF exhibited the lowest von Mises stresses, while Co-Cr exhibited the highest ones under a static load. CGF showed similar stress distribution to that of Co-Cr, but the stresses were more homogeneous and concentrated apically. In oversized and dumbbell-shaped root canal remnants, the equivalent von Mises stress in the cement layer using CGF was significantly lower than that of PGF. CONCLUSIONS: In oversized root canals and dumbbell-shaped root canals, CGF has shown good performance for restoration of endodontically treated teeth. CLINICAL RELEVANCE: This study provides a theoretical basis for clinicians to select post-core materials for residual roots with different root canal morphologies and should help to reduce the occurrence of complications such as root fracture and post-core debonding.


Asunto(s)
Vidrio , Técnica de Perno Muñón , Diente no Vital , Humanos , Coronas , Cementos Dentales , Cementos de Ionómero Vítreo , Diseño Asistido por Computadora , Análisis del Estrés Dental/métodos , Análisis de Elementos Finitos , Resinas Compuestas/química , Ensayo de Materiales , Estrés Mecánico
17.
BMC Oral Health ; 24(1): 66, 2024 01 10.
Artículo en Inglés | MEDLINE | ID: mdl-38200473

RESUMEN

BACKGROUND: Three-dimensional (3D) printing technology has revolutionized dentistry, particularly in fabricating provisional restorations. This systematic review and meta-analysis aimed to thoroughly evaluate the flexural strength of provisional restorations produced using 3D printing while considering the impact of different resin materials. METHODS: A systematic search was conducted across major databases (ScienceDirect, PubMed, Web of Sciences, Google Scholar, and Scopus) to identify relevant studies published to date. The inclusion criteria included studies evaluating the flexural strength of 3D-printed provisional restorations using different resins. Data extraction and quality assessment were performed using the CONSORT scale, and a meta-analysis was conducted using RevMan 5.4 to pool results. RESULTS: Of the 1914 initially identified research articles, only 13, published between January 2016 and November 2023, were included after screening. Notably, Digital Light Processing (DLP) has emerged as the predominant 3D printing technique, while stereolithography (SLA), Fused Deposition Modeling (FDM), and mono-liquid crystal displays (LCD) have also been recognized. Various printed resins have been utilized in different techniques, including acrylic, composite resins, and methacrylate oligomer-based materials. Regarding flexural strength, polymerization played a pivotal role for resins used in 3D or conventional/milled resins, revealing significant variations in the study. For instance, SLA-3D and DLP Acrylate photopolymers displayed distinct strengths, along with DLP bisacrylic, milled PMMA, and conventional PMMA. The subsequent meta-analysis indicated a significant difference in flexure strength, with a pooled Mean Difference (MD) of - 1.25 (95% CI - 16.98 - 14.47; P < 0.00001) and a high I2 value of 99%, highlighting substantial heterogeneity among the studies. CONCLUSIONS: This study provides a comprehensive overview of the flexural strength of 3D-printed provisional restorations fabricated using different resins. However, further research is recommended to explore additional factors influencing flexural strength and refine the recommendations for enhancing the performance of 3D-printed provisional restorations in clinical applications.


Asunto(s)
Resistencia Flexional , Polimetil Metacrilato , Humanos , Resinas Compuestas , Resinas Acrílicas , Impresión Tridimensional
18.
BMC Oral Health ; 24(1): 732, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38926776

RESUMEN

OBJECTIVE: This study aimed to compare the remineralization effects of a calcium silicate-based cement (Biodentine) and of a glass ionomer cement (GIC: Fuji IX) on artificially demineralized dentin. METHODS: Four standard cavities were prepared in dentin discs prepared from 34 extracted sound human third molars. In each disc, one cavity was covered with an acid-resistant varnish before demineralization (Group 1). The specimens were soaked in a chemical demineralization solution for 96 h to induce artificial carious lesions. Thereafter, one cavity each was filled with Biodentine (Group 2) and GIC (Group 3), respectively, and one carious lesion was left unrestored as a negative control (Group 4). Next, specimens were immersed in simulated body fluid (SBF) for 21 days. After cross-sectioning the specimens, the Ca/P ratio was calculated in each specimen by using scanning electron microscopy-energy-dispersive X-ray spectroscopy (SEM-EDX). Finally, data were analyzed using repeated-measures ANOVA with post-hoc Bonferroni correction. RESULTS: Both cement types induced dentin remineralization as compared to Group 4. The Ca/P ratio was significantly higher in Group 2 than in Group 3 (p < 0.05). CONCLUSION: The dentin lesion remineralization capability of Biodentine is higher than that of GIC, suggesting the usefulness of the former as a bioactive dentin replacement material. CLINICAL RELEVANCE: Biodentine has a higher remineralization ability than that of GIC for carious dentin, and its interfacial properties make it a promising bioactive dentin restorative material.


Asunto(s)
Compuestos de Calcio , Dentina , Cementos de Ionómero Vítreo , Microscopía Electrónica de Rastreo , Silicatos , Remineralización Dental , Compuestos de Calcio/uso terapéutico , Compuestos de Calcio/farmacología , Cementos de Ionómero Vítreo/uso terapéutico , Cementos de Ionómero Vítreo/farmacología , Humanos , Silicatos/uso terapéutico , Silicatos/farmacología , Dentina/efectos de los fármacos , Remineralización Dental/métodos , Técnicas In Vitro , Espectrometría por Rayos X , Calcio , Ensayo de Materiales , Caries Dental , Fósforo
19.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762747

RESUMEN

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Asunto(s)
Materiales de Impresión Dental , Glutaral , Ensayo de Materiales , Polivinilos , Siloxanos , Materiales de Impresión Dental/química , Polivinilos/química , Siloxanos/química , Factores de Tiempo , Glutaral/química , Desinfectantes Dentales/química , Hipoclorito de Sodio/química , Desinfectantes/química , Clorhexidina/química , Propiedades de Superficie , Humanos
20.
BMC Oral Health ; 24(1): 660, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38840111

RESUMEN

BACKGROUND: Effects of ceramic translucency, layer thickness, and substrate colour on the shade of lithium disilicate glass-ceramic restorations proved to be significant in several studies, however, quantitative, numerical results on the relationship between the colour difference and these parameters are still lacking. The purpose of this in vitro study was to quantitatively determine how the colour reproduction ability of a lithium disilicate glass-ceramic is affected by its translucency, layer thickness, and substrate colour. METHODS: Ceramic samples were prepared from A2 shade IPS e.max CAD blocks with high and low translucencies (HT and LT) in a thickness range of 0.5-2.5 mm (+/- 0.05 mm). Layered samples were acquired utilizing composite substrates in 9 shades; transparent try-in paste was used. The spectral reflectance of the specimens was assessed under D65 standard illumination with a Konica Minolta CM-3720d spectrophotometer. The CIEDE2000 colour difference (ΔE00) between two samples was analysed using perceptibility and acceptability thresholds set at 50:50%. Statistical analysis involved linear regression analysis and the Kruskal-Wallis test. RESULTS: An increase in the thickness of 0.5 mm reduced the ΔE00 of the HT samples to 72.8%, and that of the T samples to 71.1% (p < 0.0001). 7 substrates with HT and LT specimens had significantly different results from the mean (p < 0.05). A thickness of 0.5 mm is not sufficient to achieve an acceptable result at any level of translucency, while the low translucency ceramic at a thickness of 1.5 mm gave acceptable results, except for severely discoloured substrates (ND8 and ND9). CONCLUSIONS: The colour reproduction ability of lithium disilicate glass-ceramics is significantly affected by their translucency, layer thickness, and 7 substrates out of 9 substrates examined.


Asunto(s)
Cerámica , Color , Porcelana Dental , Porcelana Dental/química , Cerámica/química , Coloración de Prótesis , Espectrofotometría , Ensayo de Materiales , Humanos , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA